Open-access Factors influencing apical debris extrusion during endodontic treatment - A review of the literature

INTRODUCTION

The primary cause of a periapical inflammatory lesion is intra-radicular microbial infection.123,4

Technically, the goal of instrumentation and irrigation is to debride and entirely remove infected tissue debris from the root canal system and create a uniform conical shape that allows medicament delivery and adequate obturation.4,5 Microbiologically, the goal of instrumentation and irrigation is to eliminate micro-organisms, reduce their survival in the root canal system and neutralise any antigenic potential of the microbial components remaining in the canal.4,6,7

Clinical relevance of debris extrusion

During chemo-mechanical preparation, dentinal chips, pulpal fragments, necrotic debris, irrigants and microorganisms may be inadvertently disseminated from the root canal into periapical tissues,89-10

The amount of material extruded through the apical foramen is one of the main concerns when using an instrumentation technique,1112-14 The frequency of these complications is reported to range between 1.4% and 16%.1015

All instrumentation techniques and files are associated with apical extrusion of debris (Figure 1); however, the amount of extruded debris may differ according to the preparation technique used.8,16,17 The design of rotary files and the chosen kinematics contributes to accumulating dentinal debris into the flutes of the preparation instruments and directing it coronally toward the canal orifice, lessening apical compaction of debris.1819,20 Nair et al.21

Instrumentation techniques

Manual techniques

Ruiz-Hubard et al.222324

Manual vs. rotary techniques

A mutual finding in the aforementioned studies is that a push-pull canal enlargement action such as filing produces more apical debris than instrumentation techniques that incorporate a rotational force. This led to the hypothesis that engine-driven rotary instruments using the balanced force technique will produce less debris than hand-filing techniques, decreasing potential for periradicular tissue irritation and postoperative sequelae.2526

Similarly, numerous studies report that using K-files for root canal instrumentation results in more postoperative pain than does rotary system use.27-29 However, Cigek et al.302728

Continuous vs. reciprocating single-file systems

Previous studies on postoperative pain have reported inconsistent results from the use of continuous rotary systems and reciprocating systems.20,31-33 In analysing post-operative pain, three different studies opted for One Shape (Micro-Mega, Besancon, France) as the file of choice for the rotary single-file instrument group in comparison with different single-file reciprocating in-struments.29,32,34 Among the three relevant articles, Jain et al.342932

A meta-analysis conducted by Sun et al.35

A study by Robinson et al.36

Relationship between bacterial extrusion and amount of debris

A study using a multipurpose analytic approach compared the levels of apically extruded bacterial and hard-tissue debris and intracanal bacterial reduction after root canal preparation. Apical extrusion of bacteria occurred in 90% for XP-endo Shaper (FKG Dentaire, La Chaux-de-Fonds, Switzerland) and 81% for Reciproc (VDW).

Intracanal bacterial reduction was greater when using the XP-endo Shaper. Both reciprocating and continuous rotation techniques produced similar volumes of hard-tissue debris extrusion. Hard-tissue debris extrusion was less frequent than bacterial extrusion and no correlation was observed between the volume of extruded debris and counts of extruded bacteria.37

These contradictory findings justify the need for further investigation of widely used systems.111138-40 Since new instruments and techniques are saturating the market, evaluation of current practices is important.

Rotary kinematics

Three groups of instruments are available for root canal preparation: manually operated instruments, engine-driven rotary instruments and engine-driven reciprocating instru-ments.41Figure 2).42,43 Conventional continuous rotation has an increased risk of NiTi instrument fracture caused by torsional and flexural stresses.44,45

Torsional fatigue is the twisting of a metal shaft around its longitudinal axis at one terminus, while the other file terminus is static (Figure 3).4446

Cyclic fatigue ensues when a metal is subjected to recurrent cycles of tension and compression, causing its structure to deteriorate (Figure 4).4446,48

Cyclic fatigue is most likely to occur in a canal with a severe curve and a short radius of curvature,44,49 whereas torsional stress might develop in straight canals.5051

Increasing resistance to file separation has been the main goal of manufacturers in developing the latest NiTi rotary instruments, aimed at improving safety by means of pioneering design and manufacturing processes.52,53 To overcome the breakage of endodontic instruments caused by flexural fatigue, reciprocating movement was introduced.54 54-56

Reciprocation, defined as any repetitive back-and-forth (up and down or forward and reverse) movement, was originally introduced in endodontics in 19 5 8.42,43 Early reciprocating systems used an equal alternating motion of 90° angles and in more recent systems of 30° angles, none of which would complete a full rotation cycle.43 42

Most recent developments contributed to the introduction of systems based on a new mode of mechanical rotation, a multiple reciprocation motion completing a 360° cycle (Figure 5). In 2010, VDW launched Reciproc and in 2011 Dentsply Sirona launched WaveOne (Dentsply Sirona, Ballaigues, Switzerland), both of which are indicated for use as single-file techniques in automated reciprocation.43

The kinematics of reciprocating instrumentation is complex. Contrary to continuous rotary motion, the files rotate in a reverse balanced force turning back and forth.57,58

Reciprocating file systems use the alternating movement of unequal CW and CCW cutting angles (different to full sequence continuous rotation files) to prevent torsional fracture. Reciprocating movement aims to reduce this risk by engaging the file in a cutting motion, and then immediately disengaging it in a non-cutting motion.59

Reciprocating files currently available on the market are single-file systems designed to have a greater engaging CCW angle (left-cutting) than the disengaging CW angle (non-cutting).6058

A number of studies have compared apical debris extrusion of continuous rotation systems with reciprocating systems. Multiple authors report that reciprocating files extruded more apical debris than rotary files.61-64 In contrast, numerous authors found that reciprocating instruments produced less apical debris extrusion than rotary instrumentation.65-68 Various studies also showed no significant difference between the two systems.69-72

A recent study investigated the amount of apically extruded debris created by the reciprocating file Reciproc blue (VDW) versus continuous rotation files HyFlex EDM (Coltene, Altstätten, Switzerland) and XP-endo Shaper (FKG Dentaire) during root canal preparation at body temperature. The XP-endo Shaper group extruded a significantly smaller amount of debris than Reciproc blue, whereas no significant difference was registered between the HyFlex EDM files and the other NiTi files tested.73 74

Apical patency

Throughout canal instrumentation, both pulpal and dentinal debris can block the apical portion of the root canal and lead to procedural errors.2475

Establishing apical patency is the initial step in root canal treatment. The patency file ought to be used prior to irrigation to loosen compacted tissue remnants.7677,78 Apical patency is maintained by repetitive recapitulation through the apical constriction with a small K-file with the aim of keeping the root canal free of debris.79

Lambrianidis et al.803980

A patency file should be used with care, because it may force accumulated debris apically with the risk of inoculating microbes into the periapical region.8182

Glide path

Glide path preparation is an adjunctive preliminary procedure prior to canal instrumentation.7883 842,85 Initial glide path creation assists in minimising preparation times and preserves the original anatomy with little modifications and aberrations to the root canal curvature,8378

Manual and rotary glide path instruments are the first files to negotiate narrow and calcified root canal systems, hence they encounter high levels of torsional stress.44 86

The creation of a glide path has been recognised as crucially important in reducing the incidence of instrument fracture due to reduced torsional and flexural stress on the root canal instrument.8783,87-89

One of the risks of any instrumentation technique is apical debris extrusion, which increases the possibility of postoperative inflammatory reaction.9025

Topguoglu et al.9192

The study compared the amount of apically extruded debris after using multiple glide path files, before preparing curved root canals with the reciprocating Primary Wave-One Gold single file. They found that K-files showed a significantly higher amount of debris extrusion than One G glide path files (Micro-Mega), which could be explained by the fact that the tip diameter of One G files (0.14mm) is smaller than the other glide path files used in the study.

However, there was no significant difference between the K-files and the other rotary glide path files in terms of apical debris extrusion.9239

More debris is generally extruded during the main shaping procedure, than during the glide path preparation procedure. However in the latter, although the amount of debris may be small, this initially extruded debris may contain higher toxicity than debris extruded later by the shaping instrument.11

Instrument design

The objective of biomechanical preparation is to remove vital and necrotic pulp tissue, infected radicular dentine, micro-organisms and microbial toxins from the root canal system.93945,95

It is important to note that the design of rotary files and the selected motion contribute to collecting dentinal debris in the flutes of the instruments and directing it coronally toward the canal orifice, lessening the compaction of debris in the root canal.184096

In search of superior NiTi alloy properties, manufacturers have used new manufacturing methods, postproduction material heat treatments and different cross-sectional designs. NiTi alloys used for endodontic files can be grouped into instruments that primarily comprise the austenite structural phase (conventional NiTi, M-Wire, R-Phase) and those predominantly comprising the martensite structural phase (CM Wire, Gold and Blue heat-treated NiTi).97

Heat-treated NiTi alloys include M-Wire, R-Phase and CM-Wire. M-wire has three crystalline phases: deformed and micro-twinned martensite, R-Phase, and austenite. M-Wire and R-Phase instruments show greater resistance to cyclic fatigue and superior flexibility than conventional NiTi files. CM-Wire uses the stable martensite phase because the austenite finishing temperature is above working temperature. CM-Wire reverts to its original shape after heat application or autoclaving.98

Currently available rotary NiTi file endodontic systems cater for both continuous rotation and reciprocating motion. The most widely used continuous rotation systems are Pro-Taper Universal (Dentsply Sirona), ProTaper Next (Dentsply Sirona), Revo-S (Micro-Mega), One Shape (Micro-Mega), One Curve (Micro-Mega), HyFlex CM (Coltene), HyFlex EDM (Coltene) and TruNatomy (Dentsply Sirona). WaveOne (Dentsply Sirona), WaveOne Gold (Dentsply Sirona), Reciproc (VDW) and Reciproc blue (VDW) are the main endodontic file brands that are used in reciprocation.99

Clockwise/forward/right-cutting reciprocation

Reciprocating motion is an evolution of the balanced force technique offering an alternative method to prevent procedural errors during root canal instrumenation.10055,101 Based on several studies, root canal shaping with reciprocating motion has been postulated to offer superior fracture resistance.54,101-104

Paqué105106

All continuous rotation systems are designed to cut in a CW direction (right-cutting). The rotary CW cutting instrument may neither cut nor infiltrate the canal walls if used in CCW reciprocating motion. Since the reciprocating file systems have been designed to cut in a CCW direction (left-cutting), the CCW angle of motion is greater that the CW angle.107106

In 2016, two studies evaluated the effects of kinematics on apical debris extrusion. These studies assessed the same instruments, used in the same sequence. Movement kinematics was the only variable between different groups, therefore excluding other variables such as the instrumentation sequence, instrument alloy and instrument design. The authors concluded that movement kinematics significantly affected the amount of apically extruded debris.108,109 Karatas et al.108

The decreased reciprocation range in the 90° CW-30° CCW group produced more debris extrusion. The increased reciprocation range in the 150° CW-30° CCW group could have generated less extrusion because more debris was transported coronally by the file acting as a screw conveyor due to the enlarged reciprocation range. Arslan et al.109

Solutions and debris extrusion

Irrigation is an essential part of the debridement sequence. Both dentine debris and the smear layer adhering to the canal walls are created by the engagement of en-dodontic instruments during preparation,110111110

Irrigant infiltration of the apical portion of the canal is essential in order to clean and keep it free of debris,829 112

In a recent study by Gupta et al.113

Elimination of dentine and pulpal debris is thought to be improved with frequent and abundant irrigation.11411511611739

Sodium hypochlorite (NaOCl) solution has the ability to dissolve organic material,11811912076121

In addition to dentinal debris collection within the root canal, endodontic instrumentation techniques produce a smear layer that accumulates on the root canal walls and blocks the openings of dentinal tubules. The smear layer consists of organic and inorganic substances including dentinal filings, fragments of odontoblastic processes and micro-organisms.122

Ethylenediaminetetraacetic acid (EDTA) is a chelating agent used as a final irrigant to remove the potentially infected smear layer and open calcified canals due to its decalcifying properties. Although NiTi instrument manufacturers recommend using EDTA preparations for lubrication during canal instrumentation, contact between EDTA and the periapical tissue cannot be excluded.123

A study by Cruz et al.124

De Deus et al.125

CONCLUSION

Apart from instrumentation techniques, instrument design and irrigation methods, kinematics plays an important role in apical extrusion of debris and should be viewed as a key factor in the complex aetiology of debris extrusion. Careful selection of endodontic instruments and the utilization of alternative rotary kinematics in a clinical setting might aid in the reduction of debris extrusion and subsequently limit irritation to peripapical tissue.

References

  • 1. Möller AJR, Fabricius L, Dahlen G, Öhman AE, et al. Influence on periapical tissues of indigenous oral bacteria and necrotic pulp tissue in monkeys. Eur J Oral Sci. 1981; 89(6): 475-84.
  • 2. Berutti E, Negro AR, Lendini M, Pasqualini D. Influence of manual preflaring and torque on the failure rate of ProTaper rotary instruments. J Endod. 2004; 30(4): 228.
  • 3. Ng YL, Mann V, Rahbaran S, Lewsey J, et al. Outcome of primary root canal treatment: systematic review of the literature - Part 2. Influence of clinical factors. Int Endod J. 2008; 41(1): 6-31.
  • 4. Haapasalo M, Endal U, Zandi H, Coil JM. Eradication of en-dodontic infection by instrumentation and irrigation solutions. Endod Topics. 2005; 10(1): 77-102.
  • 5. Peters OA. Current challenges and concepts in the preparation of root canal systems: A review. J Endod. 2004; 30(8): 559-67.
  • 6. Riitano F. Anatomic Endodontic Technology (AET) - a crown-down root canal preparation technique: basic concepts, operative procedure and instruments. Int Endod J. 2005; 38(8): 575-87.
  • 7. Wang J, Jiang Y, Chen W, Zhu C, et al. Bacterial flora and extraradicular biofilm associated with the apical segment of teeth with post-treatment apical periodontitis. J Endod. 2012; 38(7): 954-9.
  • 8. Kustarci A, Akpinar KE, Er K. Apical extrusion of intracanal debris and irrigant following use of various instrumentation techniques. Oral Surg, Oral Med, Oral Pathol, Oral Radiol, Endodontol. 2008; 105(2): 257-62.
  • 9. Siqueira JF. Microbial causes of endodontic flare-ups. Int E ndod J. 2003; 36(7): 453-63.
  • 10. Siqueira JF, Jr., Rôças IN, Favieri A, Machado AG, et al. Incidence of postoperative pain after intracanal procedures based on an antimicrobial strategy. J Endod. 2002; 28(6): 457-60.
  • 11. Tanalp J, Güngör T. Apical extrusion of debris: a literature review of an inherent occurrence during root canal treatment. Int Endod J. 2014; 47(3): 211-21.
  • 12. Yusuf H. The significance of the presence of foreign material periapically as a cause of failure of root treatment. Oral Surg Oral Med Oral Pathol. 1982; 54(5): 566-74.
  • 13. Sjogren U, Hagglund B, Sundqvist G, Wing K. Factors affecting the long-term results of endodontic treatment. J Endod. 1990; 16(10): 498-504.
  • 14. Siqueira JF. Aetiology of root canal treatment failure: why well-treated teeth can fail. Int Endod J. 2001; 34(1): 1-10.
  • 15. Torabinejad M, Walton RE. Managing endodontic emergencies. J Am Dent Assoc (1939). 1991; 122(5): 99,101,3.
  • 16. Bürklein S, Schäfer E. Apically extruded debris with reciprocating single-file and full-sequence rotary instrumentation systems. J Endod. 2012; 38(6): 850-2.
  • 17. Kirchhoff AL, Fariniuk LF, Mello I. Apical extrusion of debris in flat-oval root canals after using different instrumentation systems. J Endod. 2015; 41(2): 237-41.
  • 18. Beeson TJ, Hartwell GR, Thornton JD, Gunsolley JC. Comparison of debris extruded apically in straight canals: Conventional filing versus profile .04 Taper series 29. J Endod. 1998; 24(1): 18-22.
  • 19. Buldur B, Hascizmeci C, Aksoy S, Nur Aydin M, et al. Apical extrusion of debris in primary molar root canals using mechanical and manual systems. Eur J Paediatr Dent. 2018; 19(1): 16 -20.
  • 20. Kherlakian D, Cunha RS, Ehrhardt IC, Zuolo ML, et al. Comparison of the incidence of postoperative pain after using 2 reciprocating systems and a continuous rotary system: A prospective randomized clinical trial. J Endod. 2016; 42(2): 171-6.
  • 21. Nair PNR, Henry SP, Cano V, Vera J. Microbial status of apical root canal system of human mandibular first molars with primary apical periodontitis after "one-visit" endodontic treatment. Oral Surg, Oral Med, Oral Pathol, Oral Radiol Endodontol. 2005; 99(2): 231-52.
  • 22. Ruiz-Hubard EE, Gutmann JL, Wagner MJ. A quantitative assessment of canal debris forced periapically during root canal instrumentation using two different techniques. J Endod. 1987; 13(12): 554-8.
  • 23. McKendry DJ. Comparison of balanced forces, endosonic, and step-back filing instrumentation techniques: quantification of extruded apical debris. J Endod. 1990; 16(1): 24-7.
  • 24. Al-Omari MAO, Dummer PMH. Canal blockage and debris extrusion with eight preparation techniques. J Endod. 1995; 21(3): 154.
  • 25. Reddy SA, Hicks ML. Apical extrusion of debris using two hand and two rotary instrumentation techniques. J Endod. 1998; 24(3): 180-3.
  • 26. Del Fabbro M, Afrashtehfar KI, Corbella S, El-Kabbaney A, et al. In vivo and in vitro effectiveness of rotary nickel-titanium vs manual stainless steel instruments for root canal therapy: Systematic review and meta-analysis. J Evid Based Dent Pract. 2018; 18(1): 59-69.
  • 27. Arias A, de la Macorra JC, Azabal M, Hidalgo JJ, et al. Prospective case controlled clinical study of post-endodontic pain after rotary root canal preparation performed by a single operator. J Dent. 2015;43(3):389-95.
  • 28. Kashefinejad M, Harandi A, Eram S, Bijani A. Comparison of single visit post endodontic pain using Mtwo rotary and hand K-file instruments: A Randomized Clinical Trial. J Dent (Tehran). 2016; 13(1): 10-7.
  • 29. Mollashahi NF, Saberi EA, Havaei SR, Sabeti M. Comparison of postoperative pain after root canal preparation with two reciprocating and rotary single-file systems: A randomized clinical trial. Ir Endod J. 2017; 12(1): 15-9.
  • 30. Cigek E, Kogak MM, Kogak S, Sag-lam BC, et al. Postoperative pain intensity after using different instrumentation techniques: a randomized clinical study. J Appl Oral Sci: revista FOB. 2017; 25(1): 20-6.
  • 31. Gambarini G, Testarelli L, De Luca M, Milana V, et al. The influence of three different instrumentation techniques on the incidence of postoperative pain after endodontic treatment. Ann Stomatol (Roma). 2013; 4(1): 152-5.
  • 32. Neelakantan P, Sharma S. Pain after single-visit root canal treatment with two single-file systems based on different kinematics - a prospective randomized multicenter clinical study. Clin Oral Investig. 2015; 19(9): 2211-7.
  • 33. Relvas JBF, Bastos MMB, Marques AAF, Garrido ADB, et al. Assessment of postoperative pain after reciprocating or rotary NiTi instrumentation of root canals: A randomized, controlled clinical trial. Clin Oral Investig. 2016; 20(8): 1987-93.
  • 34. Jain N, Pawar A, Gupta A. Incidence and severity of post-operative pain after canal instrumentation with reciprocating system, continuous rotary single file system, versus SAF system. Endod practice. 2016; 10: 153-60.
  • 35. Sun C, Sun J, Tan M, Hu B, et al. Pain after root canal treatment with different instruments: A systematic review and meta-analysis. Oral Dis. 2018; 24(6): 908-19.
  • 36. Robinson JP, Lumley PJ, Cooper PR, Grover LM, et al. Reciprocating root canal technique induces greater debris accumulation than a continuous rotary technique as assessed by 3-dimensional micro-computed tomography. J Endod. 2013; 39(8): 1067-70.
  • 37. Alves FRF, Paiva PL, Marceliano-Alves MF, Cabreira LJ, et al. Bacteria and hard tissue debris extrusion and intracanal bacterial reduction promoted by XP-endo Shaper and Reciproc instruments. J Endod. 2018; 44(7): 1173-8.
  • 38. Caviedes-Bucheli J, Castellanos F, Vasquez N, Ulate E, et al. The influence of two reciprocating single-file and two rotary-file systems on the apical extrusion of debris and its biological relationship with symptomatic apical periodontitis. A systematic review and meta-analysis. Int Endod J. 2016; 49(3): 255-70.
  • 39. Tinaz AC, Alacam T, Uzun O, Maden M, et al. The effect of disruption of apical constriction on periapical extrusion. J Endod. 2005; 31(7): 533-5.
  • 40. Tanalp J, Kaptan F, Sert S, Kayahan B, et al. Quantitative evaluation of the amount of apically extruded debris using 3 different rotary instrumentation systems. Oral Surg, Oral Med, Oral Pathol, Oral Radiol, Endodontol. 2006; 101(2): 250-7.
  • 41. Hargreaves K, Berman L, Rotstein I. Cohen's pathways of the pulp. Eleventh edition. ed: Mosby: Elsevier Health Sciences; 2015.
  • 42. Jain P. Current therapy in endodontics. Ames, Iowa: Wiley Blackwell; 2016.
  • 43. Webber J. Shaping canals with confidence: WaveOne GOLD single-file reciprocating system. Roots. 2015(1): 34-40.
  • 44. Sattapan B, Nervo GJ, Palamara JEA, Messer HH. Defects in rotary nickel-titanium files after clinical use. J Endod. 2000; 26(3): 161-5.
  • 45. Sotokawa T. An analysis of clinical breakage of root canal instruments. J Endod. 1988; 14(2): 75-82.
  • 46. Sattapan B, Palamara JEA, Messer HH. Torque during canal instrumentation using rotary nickel-titanium files. J Endod. 2000; 26(3): 156-60.
  • 47. Martin B, Zelada G, Varela P, Bahillo JG, et al. Factors influencing the fracture of nickel-titanium rotary instruments. Int Endod J. 2003; 36(4): 262-6.
  • 48. Gabel WP, Hoen M, Steiman HR, Pink FE, et al. Effect of rotational speed on nickel-titanium file distortion. J Endod. 1999; 25(11): 752-4.
  • 49. Pruett JP, Clement DJ, Carnes DL. Cyclic fatigue testing of nickel-titanium endodontic instruments. J Endod. 1997; 23(2): 77-85.
  • 50. Plotino G, Grande NM, Melo MC, Bahia MG, et al. Cyclic fatigue of NiTi rotary instruments in a simulated apical abrupt curvature. Int Endod J. 2010; 43(3): 226-30.
  • 51. Parashos P, Messer HH. Rotary NiTi instrument fracture and its consequences. J Endod. 2006; 32(11): 1031-43.
  • 52. Tripi TR, Bonaccorso A, Condorelli GG. Cyclic fatigue of different nickel-titanium endodontic rotary instruments. Oral Surg, Oral Med, Oral Pathol, Oral Radiol, Endodont. 2006; 102(4): 106-14.
  • 53. Gambarini G, Grande NM, Plotino G, Somma F, et al. Fatigue resistance of engine-driven rotary nickel-titanium instruments produced by new manufacturing methods. J Endod. 2008; 34(8): 1003-5.
  • 54. De-Deus G, Moreira EJL, Lopes HP, Elias CN. Extended cyclic fatigue life of F2 ProTaper instruments used in reciprocating movement. Int Endod J. 2010; 43(12): 1063-8.
  • 55. You S-Y, Bae K-S, Baek S-H, Kum K-Y, et al. Lifespan of one nickel-titanium rotary file with reciprocating motion in curved root canals. J Endod. 2010; 36(12): 1991-4.
  • 56. Gambarini G, Gergi R, Naaman A, Osta N, et al. Cyclic fatigue analysis of twisted file rotary NiTi instruments used in reciprocating motion. Int Endod J. 2012; 45(9): 802-6.
  • 57. Jonker C, van der Vyver PJ. Reciprocating instruments in en-dodontics: A review of the literature. S Afr Dent J. 2014; 69(9): 404-9.
  • 58. Webber J, Machtou P, Pertot W, Kuttler S, et al. The WaveOne single-file reciprocating system. Roots. 2011; 1: 28-33.
  • 59. Gupta R, Tomer A, Rohilla S. Single file endodontics: Boon or myth? Asian Pacific J Health Sci. 2016; 3(2): 102-5.
  • 60. Fidler A. Kinematics of 2 reciprocating endodontic motors: The difference between actual and set values. J Endod. 2014; 40(7): 990-4.
  • 61. Bürklein S, Benten S, Schäfer E. Quantitative evaluation of apically extruded debris with different single-file systems: Reci-proc, F360 and OneShape versus Mtwo. Int Endod J. 2014; 47(5): 405-9.
  • 62. Bürklein S, Schäfer E. Apically extruded debris with reciprocating single-file and full-sequence rotary instrumentation systems. J Endod. 2012; 38(6): 850-2.
  • 63. Toyoglu M, Altunbas D. Influence of different kinematics on apical extrusion of irrigant and debris during canal preparation using K3XF instruments. J Endod. 2017; 43(9): 1565-8.
  • 64. Surakanti J, Venkata RC, Vemisetty H, Dandolu R, et al. Comparative evaluation of apically extruded debris during root canal preparation using ProTaper, Hyflex and Waveone rotary systems. J Conserv Dent. 2014; 17(2): 129.
  • 65. Arslan H, Dog-anay E, Alsancak M, Capar ID, et al. Comparison of apically extruded debris after root canal instrumentation using Reciproc instruments with various kinematics. Int Endod J. 2016; 49(3): 307-10.
  • 66. Üstün Y, Canakgi BC, Dinger AN, Er O, et al. Evaluation of api-cally extruded debris associated with several Ni-Ti systems. Int Endod J. 2015; 48(7): 701-4.
  • 67. Dincer AN, Er O, Canakci BC. Evaluation of apically extruded debris during root canal retreatment with several NiTi systems. Int Endod J. 2015; 48(12): 1194-8.
  • 68. Silva EJ, Carapiá MF, Lopes RM, Belladonna FG, et al. Comparison of apically extruded debris after large apical preparations by full-sequence rotary and single-file reciprocating systems. Int Endod J. 2016; 49(7): 700-5.
  • 69. Ozsu D, Karatas E, Arslan H, Topcu M. Quantitative evaluation of apically extruded debris during root canal instrumentation with ProTaper Universal, ProTaper Next, WaveOne, and self-adjusting file systems. Eur J Dent. 2014; 8(4): 504-8.
  • 70. Kogak S, Kogak MM, Sag-lam BC, Türker SA, et al. Apical extrusion of debris using self-adjusting file, reciprocating single-file, and 2 rotary instrumentation systems. J Endod. 2013; 39(10): 1278-80.
  • 71. Vivekanandhan P, Subbiya A, Mitthra S, Karthick A. Comparison of apical debris extrusion of two rotary systems and one reciprocating system. J Conserv Dent. 2016; 19(3): 245-9.
  • 72. Kirchhoff AL, Fariniuk LF, Mello I. Apical extrusion of debris in flat-oval root canals after using different instrumentation systems. J Endod. 2015; 41(2): 237-41.
  • 73. Uslu Gla, Özyürek T, Yilmaz K, Gündog-ar M, et al. Apically extruded debris during root canal instrumentation with Reciproc Blue, HyFlex EDM, and XP-endo Shaper nickel-titanium files. J Endod. 2018; 44(5): 856-9.
  • 74. Salloum S, Torbey C, Bassam S, Dib C. Reciprocal and continuous rotation is two sides of the same coin. J Dent Health Oral Disord Ther. 2018; 9(3).
  • 75. Flanders D. Endodontic patency. How to get it. How to keep it. Why it is so important. N Y State Dent J. 2002; 68: 30-2.
  • 76. Hülsmann M, Schäfer E. Apical patency: Fact and fiction-a myth or a must? A contribution to the discussion. Endo. 2009; 3: 285-307.
  • 77. Mounce RE, Glassman G. Principle driven cleaning, shaping and obturation in orthograde first-time endodontic treatment. Oral Health. 2010; 100(5): 40-9.
  • 78. Paleker F, van der Vyver PJ. Glide path enlargement of mandibular molar canals by using K-files, the ProGlider File, and G-Files: A comparative study of the preparation times. J Endod. 2017; 43(4): 609-12.
  • 79. American Association of Endodontists (AAE). Glossary of endodontic terms. 9th ed: American Association of Endodontists; 2015.
  • 80. Lambrianidis T, Tosounidou E, Tzoanopoulou M. The effect of maintaining apical patency on periapical extrusion. J Endod. 2001; 27(11): 696-8.
  • 81. Izu KH, Thomas SJ, Zhang P, Izu AE, et al. Effectiveness of sodium hypochlorite in preventing inoculation of periapical tissues with contaminated patency files. J Endod. 2004; 30(2): 92-4.
  • 82. Yaylali IE, Demirci GzK, Kurnaz S, Celik G, et al. Does maintaining apical patency during instrumentation increase post-operative pain or flare-up rate after nonsurgical root canal treatment? A systematic review of randomized controlled trials. J Endod. 2018; 44(8):1228-36.
  • 83. Hartmann RC, Peters OA, de Figueiredo JAP, Rossi-Fedele G. Association of manual or engine-driven glide path preparation with canal centring and apical transportation: a systematic review. Int Endod J. 2018; 51(11): 1239-52.
  • 84. West JD. The endodontic glidepath: "Secret to rotary safety". Dent Today. 2010; 29(9): 90-3.
  • 85. Elnaghy AM, Elsaka SE. Evaluation of root canal transportation, centering ratio, and remaining dentin thickness associated with ProTaper Next instruments with and without glide path. J Endod. 2014; 40(12): 2053-6.
  • 86. Rodrigues E, De-Deus G, Souza E, Silva EJ. Safe mechanical preparation with reciprocation movement without glide path creation: result from a pool of 673 root canals. Braz Dent J. 2016; 27(1): 22-7.
  • 87. Patino PV, Biedma BM, Liébana CR, Cantatore G, et al. The influence of a manual glide path on the separation rate of NiTi rotary instruments. J Endod. 2005; 31(2): 114-6.
  • 88. Cassim I, van der Vyver PJ. The importance of glide path preparation in endodontics: a consideration of instruments and literature. S Afr Dent J. 2013; 68(7): 324-7.
  • 89. Khatavkar R, SH. Importance of patency in endodontics. Endodontology. 2010; 22: 85-91.
  • 90. Seltzer S, Naidorf IJ. Flare-ups in endodontics: I. Etiological factors. J Endod. 1985; 11(11): 472-8.
  • 91. Topguog-lu HS, Düzgün S, Akpek F, Topguog-lu G, et al. Influence of a glide path on apical extrusion of debris during canal preparation using single-file systems in curved canals. Int Endod J. 2016; 49(6): 599-603.
  • 92. Gunes B, Yeter Y. Effects of different glide path files on apical debris extrusion in curved root canals. J Endod. 2018; 44(7): 1191-4.
  • 93. Basmadjian-Charles CL, Farge P, Bourgeois DM, Lebrun T. Factors influencing the long-term results of endodontic treatment: a review of the literature. Int Dent J. 2002; 52(2): 81-6.
  • 94. Plotino G, Özyürek T, Grande NM, Gündog-ar M. Influence of size and taper of basic root canal preparation on root canal cleanliness: A scanning electron microscopy study. Int Endod J. 2019; 52(3): 343-51.
  • 95. Grande NM, Ahmed HMA, Cohen S, Bukiet F, et al. Current assessment of reciprocation in endodontic preparation: A comprehensive review - Part I: Historic perspectives and current applications. J Endod. 2015; 41(11): 1778-83.
  • 96. Tinoco JM, De-Deus G, Tinoco EM, Saavedra F, et al. Apical extrusion of bacteria when using reciprocating single-file and rotary multifile instrumentation systems. Int Endod J. 2014; 47(6): 560-6.
  • 97. Zupanc J, Vahdat-Pajouh N, Schäfer E. New thermomecha-nically treated NiTi alloys - a review. Int Endod J. 2018; 51(10): 1088-103.
  • 98. Goo H-J, Kwak SW, Ha J-H, Pedullä E, et al. Mechanical properties of various heat-treated nickel-titanium rotary instruments. J Endod. 2017; 43(11): 1872-7.
  • 99. Ha JH, De-Deus G, Versluis A, Kwak SW, et al. Safe pseudo-elastic limit range under torsional loading with Reciproc Blue. Int Endod J. 2019; 52(2): 244-9.
  • 100. You S-Y, Kim H-C, Bae K-S, Baek S-H, et al. Shaping ability of reciprocating motion in curved root canals: A comparative study with micro-computed tomography. J Endod. 2011; 37(9): 1296-300.
  • 101. Varela-Patino P, Ibanez-Parraga A, Rivas-Mundina B, Cantatore G, et al. Alternating versus continuous rotation: A comparative study of the effect on instrument life. J Endod. 2010; 36(1): 157-9.
  • 102. Yared G. Canal preparation using only one Ni-Ti rotary instrument: preliminary observations. Int Endod J. 2008; 41(4): 339-44.
  • 103. Gavini G, Caldeira CL, Akisue E, Candeiro GTdM, et al. Resistance to flexural fatigue of reciproc R25 files under continuous rotation and reciprocating movement. J Endod. 2012; 38(5): 684-7.
  • 104. Perez-Higueras JJ, Arias A, de la Macorra JC, Peters OA. Differences in cyclic fatigue resistance between ProTaper Next and ProTaper Universal instruments at different levels. sJ Endod. 2014; 40(9): 1477-81.
  • 105. Paqué F, Zehnder M, De-Deus G. Microtomography-based comparison of reciprocating single-file F2 ProTaper technique versus rotary full sequence. J Endod. 2011; 37(10): 1394-7.
  • 106. Espir CG, Nascimento-Mendes CA, Guerreiro-Tanomaru JM, Freire LG, et al. Counterclockwise or clockwise reciprocating motion for oval root canal preparation: A micro-CT analysis. Int Endod J. 2018; 51(5): 541-8.
  • 107. Siddique R, Nivedhitha MS. Effectiveness of rotary and reciprocating systems on microbial reduction: A systematic review. J Conserv Dent. 2019; 22(2): 114-22.
  • 108. Karatas E, Arslan H, Kirici D, Alsancak M, Qapar ID. Quantitative evaluation of apically extruded debris with Twisted File Adaptive instruments in straight root canals: Reciprocation with different angles, adaptive motion and continuous rotation. Int Endod J. 2016; 49(4): 382-5.
  • 109. Arslan H, Doganay E, Alsancak M, Qapar ID, Karatas E, Gündüz HA. Comparison of apically extruded debris after root canal instrumentation using Reciproc instruments with various kinematics. Int Endod J. 2016; 49(3): 307-10.
  • 110. Paqué F, Boessler C, Zehnder M. Accumulated hard tissue debris levels in mesial roots of mandibular molars after sequential irrigation steps. Int Endod J. 2011; 44(2).
  • 111. Gizem Demiray K, Ahmet G, Bülent A, Güven K. Comparison of the smear layer- and debris-removal abilities and the effects on dentinal microhardness of 5% and 17% EDTA solutions used as final irrigants: In vitro study. Acta Odontol Turc. 2016; 33(2): 63-8.
  • 112. Kim H-J, Park S-J, Park S-H, Hwang Y-C, et al. Efficacy of flowable gel-type EDTA at removing the smear layer and inorganic debris under manual dynamic activation. J Endod. 2013; 39(7): 910-4.
  • 113. Gupta J, Nikhil V, Jha P. Corelation between machine-assisted endodontic irrigant agitation and apical extrusion of debris and irrigant: A laboratory study. Sci World J. 2014; 2014: 346184. DOI: 10.1155/2014/346184.
    » https://doi.org/10.1155/2014/346184
  • 114. Baker NA, Eleazer PD, Averbach RE, Seltzer SP. Scanning electron microscopic study of the efficacy of various irrigating solutions. J Endod. 1975; 1(4): 127-35.
  • 115. Hinrichs RE, Walker WA, 3rd, Schindler WG. A comparison of amounts of apically extruded debris using handpiece-driven nickel-titanium instrument systems. J Endod. 1998; 24(2): 102-6.
  • 116. Ferraz CCR, Gomes NV, Gomes BPFA, Zaia AA, et al. Apical extrusion of debris and irrigants using two hand and three engine-driven instrumentation techniques. Int Endod J. 2001; 34(5): 354-8.
  • 117. Myers GL, Montgomery S. A comparison of weights of debris extruded apically by conventional filing and canal master techniques. J Endod. 1991; 17(6): 275-9.
  • 118. Johnson BR, Remeikis NA. Effective shelf-life of prepared sodium hypochlorite solution. J Endod. 1993; 19(1): 40-3.
  • 119. Grossman LI, Meiman BW. Solution of pulp tissue by chemical agents. J Am Dent Assoc. 1941; 28(2): 223-5.
  • 120. Buck RA, Eleazer PD, Staat RH, Scheetz JP. Effectiveness of three endodontic irrigants at various tubular depths in human dentin. J Endod. 2001; 27(3): 206-8.
  • 121. Zehnder M. Root canal irrigants. J Endod. 2006; 32(5): 389-98.
  • 122. Violich D, Chandler N. The smear layer in endodontics - a review. Int Endod J. 2010; 43: 2-15.
  • 123. Putzer P, Hoy L, Günay H. Highly concentrated EDTA gel improves cleaning efficiency of root canal preparation in vitro. Clin Oral Investig. 2008; 12(4): 319-24.
  • 124. Cruz A, Vera J, Gascon G, Palafox-Sánchez CA, et al. Debris remaining in the apical third of root canals after chemomechanical preparation by using sodium hypochlorite and glyde: An in vivo study. J Endod. 2014; 40(9): 1419-23.
  • 125. De-Deus G, Marins J, de Almeida Neves A, Reis C, et al. Assessing accumulated hard-tissue debris using micro-computed tomography and free software for image processing and analysis. J Endod. 2014; 40(2): 271-6.

Correspondence:
Peet J van der Vyver
Department of Odontology, School of Dentistry, University of Pretoria
Gauteng, South Africa
Email:

Author contributions:


1. Natasa Predin Djuric: Scientific writing - 50%
2. Peet J van der Vyver: Scientific writing and proofreading of the manuscript - 20%
3. Martin Vorster: Scientific writing and proofreading of the manuscript - 20%
4. Zunaid I Vally: Final editing and proofreading of the manuscript - 10%

Correspondence

peetv@iafrica.com

Publication Dates

  • Publication in this collection
    08 Apr 2021
  • Date of issue
location_on
The South African Dental Association (SADA) The South African Dental Association (SADA), Private Bag 1, Houghton, Johannesburg, Gauteng, ZA, 2041, Tel: +27 11 530 6520 - E-mail: nmojela@sada.co.za
rss_feed Acompanhe os números deste periódico no seu leitor de RSS
Ir para o topo