Open-access Solar chimney power plant performance characteristics

Abstract

The performance characteristics of a large solar chimney power plant are evaluated. The reference plant studied has a glass-covered collector and a chimney that is 1 500 m high with a diameter of 160 m. A turbo-generator is located at the base of the chimney. The draught and relevant energy equations applicable to the plant are solved for specified meteorological data at a particular site in South Africa. It is shown that the output of the plant changes measurably during the day and that power is also generated during the night, due to the thermal capacity of the ground under the solar collector. By optimising the shape and height of the solar collector, the annual power output can be increased.


Introduction

A solar chimney power plant consists of a central chimney, surrounded by a solar collector that consists of a transparent canopy or roof supported a few metres above ground level, as shown in Fig. 1.

A turbine driving a generator is located at the base of the chimney. Solar radiation passing through the canopy strikes the ground below it from where heat is transferred to the adjacent air by means of convection. Due to buoyancy, the heated air flows towards the centre of the collector and then up the chimney where it drives the turbine.

Tests conducted at an experimental solar chimney power plant located at Manzanares in Spain have shown that the concept is sound and that performance trends are in line with predicted values.1,2 Preliminary studies have indicated that large solar chimney power plants are potentially economically viable.3,4

In this study, the performance characteristics of a large solar chimney reference power plant, having dimensions as listed in Appendix A, were determined for meteorological conditions as given in Tables AÍ and A2. These latter conditions are applicable at a site located near Sishen (27.67° South, 23.00° East) in South Africa. It was shown that the performance of the reference plant can be improved by modifying the collector geometry.

Analysis

To find the power generated by a solar chimney power plant, as shown schematically in Fig. 1, the relevant draught and energy equations have to be solved simultaneously.

1. The power output of the plant can be expressed as

where Ntg is the efficiency of the turbo-generator.

The pressure difference due to a column of cold air outside the chimney and a column of hot air inside the chimney is the driving force or potential that causes the air to flow through the plant. Blaine & Kröger5 evaluate the effect of different ambient conditions on the 'potential and show that for the case where adiabatic lapse rates are assumed outside and inside the chimney

The pressure drop between the essentially stagnant ambient air at 1 and at the inlet 2 to the collector is given by

where Ki is the collector inlet loss coefficient.

Canopy supports are arranged radially with a radial pitch Pr and a tangential pitch Pt. Air flowing radially inwards in the solar collector experiences a pressure drop across a circle of supports at a particular radius. If the height of the canopy or roof is given by H = H2(r2/r)b this pressure drop is

where Csd is the drag coefficient of the particular support and m is the radial air mass flow rate.6

The pressure drop due to all supports is obtained by the following summation:

where nst is the total number of support circles. As the air flows radially inwards it accelerates (if b < 1) with the result that the pressure drops:6

The pressure drop Δpj due to frictional effects under the collector are given by Kröger & Buys7 and Beyers8 while the pressure drop across the turbine inlet Δpti can be expressed in terms of a specified turbine inlet loss coefficient Kti. Similarly, the pressure drop ΔpcD due to the drag of appurtenances such as spokes or other reinforcements inside the chimney can be expressed in terms of a loss coefficient KC£).

For a chimney of constant cross-sectional area, the change in pressure due to the change in momentum, between the inlet and the outlet of the chimney, can be expressed as

If it is assumed that the turbulent flow in the chimney is fully developed, the frictional loss can be expressed approximately as

where according to Haaland9

where ec is the surface roughness of the concrete.

2. The energy equation applicable to the elementary control volume about the air stream in the collecter as shown in Fig. 2 is

Since ρ = p/RT and changes in cp and ρ are negligible, this equation together with the continuity relation ∂/∂r (mΔΘ) Ar = -∂/∂t (ρ r Δ θ Δr H) can be simplified to give for fully developed flow

According to Gnielinski,10 the heat transfer coefficients under the roof and on the ground for fully developed flow can be expressed as

For developing flow near the inlet of the collector

Kröger & Buys7 give values for h for developing flow under the roof and on the ground.

3. Assume that the temperature difference between the top and bottom surfaces of the glass roof is negligible and apply an energy balance to the elementary control volume shown in Fig. 2:

where qa is the heat absorbed by the glass, i.e.

where the total radiation per unit area of horizontal surface is

According to Duffie & Beekman11 the beam reflectance at the upper surface of the glass can be expressed as

where θ is the zenith angle of incidence. For diffuse radiation the approximate reflectance is determined at θ = 60° i.e. pd = 0.0934.

The beam transmittance through the glass roof due to absorption is given by

The transmittance of diffuse radiation considering only absorption, τ da is the same as that of τbα evaluated at θ = 60°.

The net longwave radiation heat transfer rate betwseen the ground and the roof is given by

The convective heat transfer rate from the glass roof to the air stream under the roof for fully developed flow is given by

and

for developing flow at the inlet of the collector.

The convective heat transfer rate from the roof to the ambient air is given by

Presently, no reliable equation exists for the convective heat transfer coefficient hra. The following relation will be employed:11

where vw is the wind speed at the roof elevation.

The net longwave radiation heat transfer rate between the glass roof and the clear sky is expressed as

where the sky temperature according to Swinbank12 is given by

4. The energy equation applicable to the elementary control volume in the ground (assuming thermophysical properties of ground are constant) as shown in Fig. 2 is given by

To solve this equation the following conditions are applicable: At z = 0

The net solar radiation per unit area absorbed by the ground is13

Numerical simulation

The performance of the solar chimney power plant is determined by maximizing the power output:

Equations (11), (14), (26), and (27) are semi-discretized by replacing spatial derivatives with finite difference approximations. The resulting equations together with equation (29) are a set of differential-algebraic equations which can be solved numerically using a standard computer code such as DASSL.14

Results

The maximum electrical power output of the reference plant on the 21st of each month is shown in Fig. 3.

There is a pronounced peak output shortly after midday and a significant difference in output during the summer and winter months. Due to the heat stored in the ground some power is also generated at night.

Examples of the temperature distributions in the ground under the collector at a radius of 200 m at different times of the day in December and in June are shown in Fig. 4 and Fig. 5. The former shows conditions near the surface of the ground more clearly.

The output of the reference plant, which is 341 GWh/a, can be increased by changing the shape of the collector roof and its inlet height H2. As shown in Fig. 6 a maximum power output is attained when b=1 and H2 = 3.3 m. For values of 6 > 1 output decreases and there is a danger of flow separation in the collector due to the fact that the flow area increases.

By enlarging the collector area the annual power output can be increased. This is shown graphically in Fig. 7 for b = 1. At every collector diameter there is a corresponding optimal inlet height.

Conclusion

The performance characteristics of a large solar chimney power plant are determined. It is shown that in such a plant there is a pronounced peak output shortly after solar noon, whilst power is also generated at night due to the energy storage capacity of the ground. The output of the reference plant considered can be increased by modifying the shape and inlet height of the solar collector. A further increase in power output can be attained by increasing the collector diameter. Due to greater heating of the air under the collector with increasing collector diameter, heat losses to the environment will also increase. For the particular plant under investigation the nett increase in annual power output is approximately linear over the range of collector diameters shown in Fig. 7.

References

  • [1] Haaf W, Friedrich KG & Schiaich J. Solar Chimneys. Part 1: Principle and Construction of the Pilot Plant in Manzanares. Int. J. Solar Energy, 1983, 2, pp.3-20.
  • [2] Haaf W. Solar Chimneys. Part 2: Preliminary Test Results from the Manzanares Plant. Int. J. Solar Energy, 1983, 2, pp. 141161.
  • [3] Schlaich J & Schiel W. Solar Chimneys, Encyclopedia of Physical Science and Technology, 3rd edn, 2000.
  • [4] Schlaich J. Tension Structures for Solar Electricity Generation. Engineering Structures, 1999, 21, pp.658-668.
  • [5] Blaine DC & Kröger DG. Analysis of the Driving Potential of a Solar Chimney Power Plant. R & D Journal, 1999, 15, pp.85-94.
  • [6] Hedderwick RA. Performance Evaluation of a Solar Chimney Power Plant. MSc(Eng) thesis, University of Stellenbosch, Stellenbosch, South Africa, 2001.
  • [9] Haaland SE. Simple Explicit Formulas for the Friction Factor in Turbulent Pipe Flow. Trans. ASME, J. Fluids Engineering, 1983, 105, pp.89-90.
  • [10] Gnielinski V. Forsch. Ing. Wesen, 1975, 41.
  • [11] Duffie JA & Beekman WA. Solar Engineering of Thermal Processes. Wiley Interscience, New York, 1974.
  • [12] Swinbank WC. Long-wave Radiation from Clear Skies. Quart. J.R. Meteorol. Soc, 1963, 89.

[13] Modest MF. Radiative Heat Transfer. McGraw Hill, New York, 1993.

[14] Brenan KE, Campbell SL & Petzold LR. Numerical Solution of Initial-value Problems in Differential-Algebraic Equations. SIAM, 1996.

First, received November 2001
Final version May 2002

Appendix A

For purposes of comparison a reference solar chimney plant and its operating environment is defined.

Power plant specifications:

a. Chimney

Chimney height Hc-1 500 m

Chimney inside diameter dc = 160 m

Chimney drag coefficient due to appurtances (based on chimney cross-sectional area) Kcd = 0.1

Chimney inside surface roughness ec = 2 χ 10~3 m

b. Collector

Collector outside diameter d2 = 2r2 = 4 000 m

Collector inside diameter d3 = 2r3 = 400 m

Collector inlet height H2 = 10 m

Collector roof shape H = H2 (r2/r)b

where b = 0.5

Collector inlet loss coefficient

(based on inlet area) Ki = 1

Collector roof roughness er = 0

Collector supports (diameter) ds = 0.15 m

Drag coefficient of supports Csd = 1

Tangential pitch of supports Pt = 10 m

Radial pitch of supports PT = 10 m

Collector roof material properties:

(5 mm thick green of edge glass)

Density pr = 2 700 kg/m3

Specific heat cpr = 840 J/kg K

Thermal conductivity kr = 0.78 W/mK

Thickness tr = 0.005 m

Extinction coefficient Ce = 32/m

Emissivity er = 0.87

Collector upper convective

heat transfer coefficient ha = 5.7 W/m2 K

c. Turbine

Turbo-generator efficiency Ntg - 0.8

Turbine inlet loss coefficient based

on turbine cross-sectional area) Kt% - 0.25

d. Ground

Type granite

Density pg = 2 640 kg/m3

Specific heat cpg = 820 J/kg K

Thermal conductivity kg = 1.73 W/mK Ground roughness = 0.05 m

Emissivity = 0.9

Absorbance ag = 0.9

e. Ambient conditions

Air pressure pa = 90 000 N/m2

Wind speed vw = 0 m/s

Air temperatures are presented in Table A.l, whilst details of the solar radiation are given in Table A.2.


Table A.1 - Click to enlarge


Table A.2 - Click to enlarge

Publication Dates

  • Publication in this collection
    11 Sept 2024
  • Date of issue

History

  • Received
  • Accepted
location_on
South African Institution of Mechanical Engineering Research and Development Journal, University of Stellenbosch, Private Bag X1, Matieland, Cape Town, Western Cape Province, ZA, 7602, Tel: +27 21 808 4091 - E-mail: gillianc@sun.ac.za
rss_feed Acompanhe os números deste periódico no seu leitor de RSS
Ir para o topo