Abstract
This article deals with the influence of lignite and other low-rank coals on the heat transfer and the conversions taking place in large coal-fired steam boilers. The lower heating value of the investigated coal ranged from 9 to 10 MJ/kg with 20 % ash and about 38 % moisture. Our analysis of the energy conversions is mainly concerned with the heat loss due to the exhaust flue gas. Changes in the composition of coal are reflected in the quality of the processes expressed as the efficiency of the boiler and the unit and in the quantity of power needed for the operation of the power plant. On the basis of measurements on power plant units our attention was focused on the influence of moisture, hydrogen, ash and sulphur changes in the coal. The heat loss and the other performances of the boiler due to the exhaust flue gas are determined in relation to the efficiency of the steam boiler and the power plant unit.