Open-access Reliability of Schirmer and Phenol Red Thread test value on dry eye patients

Abstract

BACKGROUND: The repeatability of the Schirmer test (ST) and Phenol Red Thread test (PRT) has been investigated thoroughly on patients with normal tear function; however, it is limited to dry eye patients AIM: This study aimed to compare the reliability of the ST and PRT on young adults with dry eyes SETTING: University of KwaZulu-Natal Eye Clinic METHODS: Forty-eight young adults (mean age 20.65 ± 1.71 years) participated in the study. Preliminary tests excluded dry eye-related abnormalities. Novesin (0.4%) was instilled into the right eye of each participant, followed by the administration of the ST and PRT, 5 min apart, then re-administered after a 10-min interval. The retest was conducted 1 week later with the PRT being performed first to minimise bias RESULTS: The intra-session correlation of the ST and the PRT was poor (ICC < 0.5) and the difference was statistically significant (P < 0.05). The inter-session correlation for the PRT was poor (ICC = 0.432) while the ST was moderate (ICC = 0.567) with no statistical difference observed for all parameters (P < 0.05). The Bland-Altman plots for intra- and inter-session indicate that 96% of observations fell within the 95% limits of agreement CONCLUSION: The ST and PRT demonstrated good intra-session and inter-session reliability, with ST showing better inter-session agreement than the PRT CONTRIBUTION: The ST and the PRT provide consistent and reproducible results on dry eye patients when conducted on the same individuals at different time points

dry eye; Schirmer test; Phenol Red Thread test; reliability; intra-session; intersession


Introduction

Dry eye disease (DED), or Keratoconjunctivitis sicca (KCS), is a chronic condition caused by disruption in the ocular tear film layer associated with poor quality of tears (Evaporative Dry Eye [EDE]) and or insufficient quantity of tears (Aqueous Deficient Dry Eye [ADDE]).11213,4

While a range of tests are available for dry eye assessment, the use of appropriate clinical tests is essential for the accurate diagnosis and management of dry eyes. The reliability of these tests needs to be assessed before being used for clinical and research purposes. Reliability or precision refers to the close alignment between repeated measurements and is expressed as repeatability and reproducibility.5,666

The Schirmer test (ST) and Phenol Red Thread test (PRT) are two common diagnostic tests used to determine ADDE. The ST utilises a filter paper which has some drawbacks including extended testing period (5 min) and patient discomfort.78,94,10

Nichols et al. conducted a study on inter-session repeatability of the PRT and ST, without anaesthetic, on dry eye patients and reported poor repeatability of the ST.1112131414

Ethical considerations

Ethical approval to conduct the study was obtained from the Biomedical Research and Ethics Committee (BE144/19). The study followed the principles of the Declaration of Helsinki, with informed consent obtained from participants after an explanation of the study's purpose and potential implications.

Methods

This was a quantitative, observational and comparative study conducted among young adults with ADDE. The participants were selected using a nonprobability purposive sampling methodology. A sample-size estimate for this study was n = 48 based on the within-subject standard deviation (Sw) to achieve a 20% margin of error at a 95% confidence level using the precision experiment formula, , for repeated measurements (n′).6

The preliminary assessment included: (1) case history to identify any confounding variables, (2) completion of a range of questionnaires (Ocular Surface Disease Index [OSDI], Standard Patient Evaluation of Eye Dryness [SPEED] and McMonnies) to identify symptomatic patients, as relying on a single questionnaire may result in potentially missed patients,241,4

Data collection procedure

Following the preliminary screening, the recruited participants proceeded to the PRT and ST to assess the reliability of these tests. The ST was performed first followed by the PRT, and the timing of the tests was monitored with a digital stopwatch. Novesin (0.4%) was considered the anaesthetic of choice for this study because of its lower concentration; hence, reduced drug absorption rate and risk of epithelial damage or allergic responses, particularly in DE patients.15,1615,164,1510,12,17

A repeat evaluation was administered a week later, with the PRT conducted first, followed by ST as a measure to eliminate any bias in results. Test and retest were conducted in the same room and under a similar uniform environment. Furthermore, to eliminate intra-examiner variability, a single examiner performed all tests on both occasions. In addition, a predetermined protocol was followed to minimise systematic differences.

Data management and analysis

The Statistical Package for Social Sciences version 26.0 (SPSS, Inc., Chicago, IL, United States) was used to conduct statistical analysis. Normal distribution was tested using the Shapiro-Wilk test and descriptive statistics was used to express means ± standard deviations (s.d.), while intra-session and inter-session reproducibility were assessed using the Bland-Altman analysis, One-sample t-test (significant Level at P < 0.001) and intra-class correlation coefficient (ICC) at a 95% confidence interval (CI). The ICC levels were interpreted as poor (< 0.5), moderate (0.50 to 0.75), good (0.75 to 0.90) and excellent (> 0.90).18t-test established the comparative reliability of the PRT and ST with P < 0.001 considered as statistically significant.

Results

A total of 48 subjects including 40% males (n = 19) and 60% females (n = 29) participated in the study. Their ages ranged from 18 to 25 years (mean = 20.65 ± 1.71 years) with 23% being Indian (n = 11) and 77% African (n = 37).

Table 1 shows the intra-class correlation and one-sample t-test results for intra-session repeatability of PRT and ST. These tests were conducted using two measurements (1 and 2) taken 10 min apart on the first day (Day 1) and repeated 1 week later (Day 2). The intra-session means ± s.d. for PRT values and ST values for Day 1 were 2.21 mm ± 3.04 mm and 1.81 mm ± 2.66 mm, while for Day 2 were 1.58 mm ± 2.83 mm and 1.10 mm ± 2.44 mm, respectively. The ICCs for PRT and ST measurements were < 0.5 suggesting poor intra-session association on both days with the one-sample t-test revealing statistically significant differences (P < 0.001) for all parameters except for ST on Day 2 (P = 0.003). An intra-session repeatability comparison of PRT and ST for Days 1 and 2 displays a poor correlation (ICC < 0.50) that is statistically different (P < 0.001) (Table 1).

Table 1

The Bland-Altman plots were used to evaluate the agreement between the first and second readings of PRTs and STs for Days 1 and 2. The results are displayed in Figure 1a-d. The three horizontal lines depict the mean (solid line) and the upper and lower Limits of Agreements (LoA) (dashed lines) which are set at mean ± 1.96 s.d., representing a 95% CIFor PRT (Figure 1a and b), 96% (46/48) and 100% (48/48) of the measurements fall within the 95% LoA for both days. For ST (Figure 1c and d), on Days 1 and 2, 100% (48/48) and 93.75% (45/48) of the measurements are within the 95% LoA, respectively. The mean differences for PRT on Days 1 and 2 are 2.21 mm and 1.58 mm while ST is 1.81 mm and 1.10 mm.

Table 2 shows the inter-session reproducibility and comparison of the PRT and ST for the two sessions (Days 1 and 2). The difference in means for PRT and ST is 0.326 and 0.243, respectively with PRT having poor inter-session association (ICC = 0.432), while ST being moderate (ICC = 0.567). No statistical difference was observed for both PRT and ST (P > 0.001) measurements. Comparatively (Table 2), PRT and ST readings reflect a statistically significant difference (P < 0.05) with a poor association (ICC = 0.053) between the two tests.

Table 2

The Bland-Altman plots (Figure 2) were used to evaluate the inter-session reproducibility of the PRT and ST conducted on the same participants but on different days. The three horizontal lines depict the mean (solid line) and the upper and lower LoA (dashed lines), positioned at the mean ± 1.96 standard deviations, indicating a 95% CI. The plots display that 96% (46/48) of the PRT (Figure 2a) and 97.9% (47/48) of the ST (Figure 2b) values lie within the 95% LoA.

Figure 2

Discussion

Dry eye is a prevalent condition affecting millions globally. Among numerous dry eye diagnostic tests available, PRT and ST are commonly used to measure tear production and volume; however, their reliability appears inconsistent. Furthermore, the repeatability and reproducibility of these tests on dry eye patients, even with topical anaesthetics, are somewhat constrained, with this study providing evidence of good reliability of PRT and ST.

The greater participation of females in this study may be attributed to dry eye being more prevalent in females than males.99192220

Intra-session repeatability

The intra-session correlation of both the PRT and ST is poor (ICC < 0.5) with the difference between measurements for each test being statistically significant (P < 0.001). Furthermore, the intra-session comparison of PRTs and STs tests reveals the same. Previous studies reported similar findings10,121012

The use of Bland-Altman plots is a common and preferred method to assess the agreement and repeatability of tests, providing a graphical representation that is less sensitive to outliers as opposed to ICC and T-tests.2110141410

Inter-session reproducibility

The means ± s.d. for PRTs and STs for inter-session reproducibility is lower compared to intra-session with ST being even lower with moderate association (ICC = 0.567) between the two sessions while PRT displays a poor association (ICC = 0.432). This suggests a lesser variation is observed for inter-session than intra-session evaluations and for ST over PRT for ADDE patients; however, considering the differences observed are not statistically significant, the reproducibility of both the test measurements, 1 week apart, are similar. This is further supported by the Bland-Altman plots, which show that most measurements fall within the 95% LoA for both the PRT and ST when anaesthetic is used. This indicates that both tests are reliable for assessing ADDE over two sessions spaced 1 week apart, with the ST test exhibiting slightly better reproducibility. Similarly, Nichols722

Finally, the paired-sample t-test for inter-session comparison of PRT and ST displays a poor correlation between tests with measurements being statistically different (P < 0.001). As reflected in intra-session comparison, the discrepancy between tests may be attributed to each test assessing distinct components of the tears, and the consciousness of the test in the eye inducing some reflex tearing despite the use of anaesthetic.10,14

As this study showed good intra-session repeatability and inter-session reproducibility of both PRT and ST on ADDE patients, the poor correlation especially for intra-session measurements for ST and PRT could have been influenced by the severity of the ADDE which was not controlled for in this study. The instillation of topical anaesthetic on DE patients increases the risk of epithelial damage; however, the use of one drop of Novesin (0.4%) at a time, and patients being advised not to rub their eyes during and after the testing procedure, as well as the application of ocular lubricant ensured no epithelial complication. Furthermore, post-staining revealed no epithelial compromise.

Conclusion

The study shows that both PRT and ST are reliable measures for ADDE patients. These tests demonstrate consistency in repeatability and reproducibility when conducted on the same individuals at different time points. However, it's important to note that the final diagnosis of dry eye should not be based solely on one test.

This article is based on the author's thesis entitled, 'A comparative study of the repeatability and reproducibilty of Phenol Red Thread test and Schirmer test values on dry eye patients', towards the degree of Bachelor of Optometry in the Department of Optometry, University of KwaZulu-Natal, South Africa, December 2019, with supervisors Dr. U. Nirghin and Prof. K.P. Mashige. It is available here: https://library.ukzn.ac.za/.

Competing interests

The authors declare that they have no financial or personal relationships that may have inappropriately influenced them in writing this article.

Authors' contributions

U.N., T.G., Y.H., R.M., H.N., S.P., P.Z. and K.P.M. were responsible for the conception or design of the work, the drafting of the article as well as the data collection. U.N. and K.P.M. contributed to the critical revision of the article as well as the final approval of the study.

Funding information

This research received no specific grant from any funding agency in the public, commercial or not-for-profit sectors.

Data availability

The data that support the findings of this study are available from the corresponding author, U.N., upon reasonable request.

Disclaimer

The views and opinions expressed in this article are those of the authors and are the product of professional research. The article does not necessarily reflect the official policy or position of any affiliated institution, funder, agency or that of the publisher. The authors are responsible for this article's results, findings and content.

Acknowledgements

The authors would like to thank all participants who took part in the study.

References

  • 1. Craig JP, Nichols KK, Nichols JJ, et al. TFOS DEWS II. Definition and classification report. Ocul Surf. 2017;30:276e283. https://doi.org/10.1016/j.jtos.2017.05.008
    » https://doi.org/10.1016/j.jtos.2017.05.008
  • 2. Stapleton F, Alves M, Bunya VY, et al. TFOS DEWS II. Epidemiology report. Ocul Surf. 2017;15:334-365. https://doi.org/10.1016/j.jtos.2017.05.003
    » https://doi.org/10.1016/j.jtos.2017.05.003
  • 3. Sheppard J, Lee BS, Periman LM. Dry eye disease: Identification and therapeutic strategies for primary care clinicians and clinical specialists. Ann Med. 2023;55(1):241-252. https://doi.org/10.1080/07853890.2022.2157477
    » https://doi.org/10.1080/07853890.2022.2157477
  • 4. Wolffsohn JS, Arita R, Chalmers R, et al. TFOS DEWS II diagnostic methodology report. Ocul Surf. 2017;15(3):539-574. https://doi.org/10.1016/j.jtos.2017.05.001
    » https://doi.org/10.1016/j.jtos.2017.05.001
  • 5. Mashige KP. Repeatability and reproducibility of axial length, anterior chamber depth, and crystalline lens thickness measurements using the Nidek US-500 Echoscan. Afr Vis Eye Health. 2015;74(1):1-6. https://doi.org/10.4102/aveh.v74i1.16
    » https://doi.org/10.4102/aveh.v74i1.16
  • 6. McAlinden C, Khadka J, Pesudovs K. Precision (repeatability and reproducibility) studies and sample-size calculation. J Cataract Refract Surg. 2015;41(12):2598-2604. https://doi.org/10.1016/j.jcrs.2015.06.029
    » https://doi.org/10.1016/j.jcrs.2015.06.029
  • 7. Nichols KK, Mitchell GL, Zadnik K. The repeatability of clinical measurements of dry eye. Cornea. 2004;23(3):272-285. https://doi.org/10.1097/00003226-200404000-00010
    » https://doi.org/10.1097/00003226-200404000-00010
  • 8. Hamano H, Hori M, Mitsunaga S, Kojima S, Maeshima J. Tear test (preliminary report). J Jpn Contact Lens Soc. 1982;24:103-107.
  • 9. Hao Y, Jin T, Zhu L, et al. Validation of the phenol red thread test in a Chinese population. BMC Ophthalmol. 2023;23(1):498. https://doi.org/10.1186/s12886-023-03250-3
    » https://doi.org/10.1186/s12886-023-03250-3
  • 10. Masmali A, Alqahtani TA, Alharbi A, El-Hiti GA. Comparative study of the reliability of phenol red thread test versus Schirmer test in normal adults in Saudi Arabia. Eye Contact Lens. 2014;40(3):127-131. https://doi.org/10.1097/ICL.0000000000000025
    » https://doi.org/10.1097/ICL.0000000000000025
  • 11. Nichols KK, Nichols JJ, Mitchell GL. The lack of association between signs and symptoms in patients with dry eye disease. Cornea. 2004;23(8):762-770. https://doi.org/10.1097/01.ico.0000133997.07144.9e
    » https://doi.org/10.1097/01.ico.0000133997.07144.9e
  • 12. Saleh TA, McDermott B, Bates AK, Ewings P. Phenol red thread test vs Schirmer's test: A comparative study. Eye. 2006;20(8):913-915. https://doi.org/10.1038/sj.eye.6702052
    » https://doi.org/10.1038/sj.eye.6702052
  • 13. Senchyna M, Wax MB. Quantitative assessment of tear production: A review of methods and utility in dry eye drug discovery. J Ocul Biol Dis Inform. 2008;1(1):1-6. https://doi.org/10.1007/s12177-008-9006-2
    » https://doi.org/10.1007/s12177-008-9006-2
  • 14. Vashisht S, Singh S. Evaluation of phenol red thread test versus Schirmer test in dry eyes: A comparative study. Inter J Appl Basic Med Res. 2011;1(1):40-42. https://doi.org/10.4103/2229-516X.81979
    » https://doi.org/10.4103/2229-516X.81979
  • 15. Li N, Deng XG, He MF. Comparison of the Schirmer I test with and without topical anesthesia for diagnosing dry eye. Int J Ophthalmol. 2012;5(4):478-481.
  • 16. Booysen DJ, Booysen JL. The Southern African guide to topical ophthalmic drugs. Chennai: Notion Press; 2022.
  • 17. Ghislandi GM, Lima GC. Comparative study between phenol red thread test and the Schirmer's test in the diagnosis of dry eyes syndrome. Rev Bras Oftalmol. 2016;75:438-442. https://doi.org/10.5935/0034-7280.20160088
    » https://doi.org/10.5935/0034-7280.20160088
  • 18. Koo TK, Li MY. A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J Chiroprac Med. 2016;15(2):155-163. https://doi.org/10.1016/j.jcm.2016.02.012
    » https://doi.org/10.1016/j.jcm.2016.02.012
  • 19. Versura P, Fresina M, Campos EC. Ocular surface changes over the menstrual cycle in women with and without dry eye. Gynecol Endocrinol. 2007;23(7):385-390. https://doi.org/10.1080/09513590701350390
    » https://doi.org/10.1080/09513590701350390
  • 20. Castelyn B, Majola S, Motilal R, Naidu MT, Ndebele SA, Vally TA. Prevalence of dry eye amongst black and Indian university students aged 18-30 years. Afr Vis Eye Health. 2015;74(1):6. https://doi.org/10.4102/aveh.v74i1.14
    » https://doi.org/10.4102/aveh.v74i1.14
  • 21. Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1(8476):307-310. https://doi.org/10.1016/S0140-6736(86)90837-8
    » https://doi.org/10.1016/S0140-6736(86)90837-8
  • 22. Kecskemet G, Toth-Molnar E, Janaky T, Szabo1 Z. An extensive study of phenol red thread as a novel non-invasive tear sampling technique for proteomics studies: Comparison with two commonly used methods. Int J Mol Sci. 2022;23:8647. https://doi.org/10.3390/ijms23158647
    » https://doi.org/10.3390/ijms23158647

Correspondence:
Urvashni Nirghin

Received: 15 May 2024
Accepted: 25 Nov. 2024
Published: 29 Jan. 2025

Correspondence

nirghinu@ukzn.ac.za

Publication Dates

  • Publication in this collection
    11 Dec 2025
  • Date of issue

History

  • Received
    15 May 2024
  • Accepted
    25 Nov 2024
location_on
AOSIS Publishing AOSIS Publishing, 15 Oxford Street, Durbanville, Cape Town, Western Cape, ZA, 7550, Tel: +27 21 975 2602 - E-mail: publishing@aosis.co.za
rss_feed Acompanhe os números deste periódico no seu leitor de RSS
Ir para o topo