Abstract
INTRODUCTION: CD4 testing in South Africa is based on an integrated tiered service delivery model that matches testing demand with capacity. The National Health Laboratory Service has predominantly implemented laboratory-based CD4 testing. Coverage gaps, over-/under-capacitation and optimal placement of point-of-care (POC) testing sites need investigation. OBJECTIVES: We assessed the impact of relational algebraic capacitated location (RACL) algorithm outcomes on the allocation of laboratory and POC testing sites. METHODS: The RACL algorithm was developed to allocate laboratories and POC sites to ensure coverage using a set coverage approach for a defined travel time (T). The algorithm was repeated for three scenarios (A: T = 4; B: T = 3; C: T = 2 hours). Drive times for a representative sample of health facility clusters were used to approximate T. Outcomes included allocation of testing sites, Euclidian distances and test volumes. Additional analysis included platform distribution and space requirement assessment. Scenarios were reported as fusion table maps. RESULTS: Scenario A would offer a fully-centralised approach with 15 CD4 laboratories without any POC testing. A significant increase in volumes would result in a four-fold increase at busier laboratories. CD4 laboratories would increase to 41 in scenario B and 61 in scenario C. POC testing would be offered at two sites in scenario B and 20 sites in scenario C. CONCLUSION: The RACL algorithm provides an objective methodology to address coverage gaps through the allocation of CD4 laboratories and POC sites for a given T. The algorithm outcomes need to be assessed in the context of local conditions.
Introduction
The National Health Laboratory Service (NHLS) of South Africa provides national coordination for the laboratory service, staff training, quality control and quality assurance, as well as managing the overall quality management system. Within the national network of 266 laboratories, CD4 testing is currently offered at 59 laboratories to facilitate the staging and monitoring HIV-infected patients. These laboratories operate all levels of pathology service, including routine diagnostic chemical pathology, haematology and microbiology services. CD4 testing is offered using an integrated tiered service delivery model (ITSDM) that matches daily testing demand with appropriate testing capacity. This is required to manage laboratory workload, turn-around-time (TAT), instrument capacity utilisation and cost.1,23,4
The ITSDM model aims to ensure efficient, cost-effective provision of quality testing across all health districts.11
Five testing tiers, along with a sixth coordinating tier, are defined in the ITSDM model: (1) true point-of-care (POC) services (Tier 1), reserved for hard-to-reach areas, where nursing staff attending to patients operate the testing system (< 3 tests per system per day) and initiate patients onto antiretroviral therapy; (2) POC hubs (Tier 2), namely, 'mini-laboratories' using only POC equipment for all relevant HIV and tuberculosis tests at a rate of < 10 samples per day in rural health districts; (3) community laboratories (Tier 3) processing less than 100 samples per day; (4) district laboratories (Tier 4) processing between 100 and 299 samples per day; (5) high volume centralised laboratories (Tier 5) processing in excess of 300 samples per day; and (6) Tier 6, representing a national reference/'monitoring and evaluation' centre responsible for coordination, harmonisation and standardisation of testing, as well as coordination of training and quality control across a national network of laboratories and related testing sites.1
It would also be cost effective to consolidate Tier 4 and/or Tier 5 laboratories into larger centralised laboratories ('super-laboratory'/Tier 6 level) that could process in excess of 600 samples per day, depending on efficiency of local transport systems.11
An analysis of test volumes identified that the majority of CD4 samples were received from primary healthcare clinics (67%), with a further 8% from larger community healthcare centres; this tells us that hospitals only account for 25% of test volumes.111111
The World Health Organization guidelines for a successful health laboratory network state that it is vital to provide equitable access to quality laboratory services, with specific attention focused on rural, semi-urban and underserved areas.5
The flow diagram (Figure 1) describes this process, detailing all the steps required to deliver a CD4 result to a health facility. CD4 samples are collected by healthcare workers and delivered to the local laboratory by either courier and/or messenger. Where the local laboratory offers CD4 testing, results are delivered following sample analysis. If CD4 testing is not offered at the local laboratory the procedure is as follows: (1) sample registered as a referral on the Laboratory Information System; (2) sample packaged for delivery to the testing laboratory; (3) sample transported by inter-laboratory courier service; (4) samples registered at the CD4 laboratory's Laboratory Information System; (5) sample tested; (6) result printed at the local laboratory; and (vii) result delivered to the health facility. The NHLS strategic plan (2010-2015) aimed to deliver quality, timely, accessible and customer-focused services.6
The current CD4 service has predominantly implemented Tiers 4 and 5 of the ITSDM model. Tier 4 laboratories use the Epics XL MCLTM flow cytometers with the PrepPlus IITM workstation from Beckman Coulter. Tier 5 laboratories use higher throughput platforms with greater automation that could process up to 800 samples per day, depending on the number and configuration of the platforms implemented, for example, the 2 + 1 configuration that consists of two CellmekTM cell preparation systems and one MPLTM flow cytometer (also from Beckman Coulter). The NHLS is currently replacing the Epics XL MCLTM flow cytometers with the AQUOIS™ load and go system (Beckman Coulter). The different flow cytometer platforms offer daily throughput of up to 386 samples per day and per system, suitable for busy laboratories (CellmekTM and MPLTM). In contrast, the Epics XL MCLTM offers a daily capacity of up to 150 samples per day per system, which is appropriate for smaller laboratories at district hospitals. POC testing was based on the Alere PimaTM platform (Alere Technologies GmbH, Jena, Germany).
A pilot Tier 3 laboratory was implemented at the rural De Aar laboratory78
The current challenge the NHLS faces is over-capacitation in urban areas and under-capacitation in selected rural areas. Therefore, the objective of this study was to identify and address coverage gaps, identify over-subscribed areas and assess the impact the relational algebraic capacitated location (RACL) outcomes would have on placement of laboratory sites, test volumes, platform choice and space requirements.
Methods
Spatial representation of RACL algorithm output for each scenario
The RACL algorithm was developed to allocate CD4 laboratories and POC sites to ensure coverage for all health facilities to CD4 testing within a pre-determined travel time (T) using a set coverage approach.9,109,109,109,1099,109,10Figure 2.
For the purposes of this study, data included 3200 health facilities tested at 62 CD4 testing sites (part of the 266 NHLS laboratories) with a daily capacity of 3600 tests. Provincial and/or NHLS boundaries were not considered for modelling.
The RACL model was repeated for the following travel times:9,10
• Scenario A: T = 4 hours
• Scenario B: T = 3 hours
• Scenario C: T = 2 hours.
The algorithm outcomes for the scenarios above were visualised using Google® Fusion Tables as follows:9,10
• Red point marker icon (letter A): Existing CD4 laboratories.
• Red point marker icon (letter E): Introduction of CD4 testing at an existing NHLS laboratory (that does not currently offer CD4 testing).
• Small blue circle: POC sites.
• Lines represent the Euclidian distance (km) from the health facility cluster to the CD4 laboratory as follows: (1) green, where T = 2 hours; (2) purple, where T = 3 hours; and (3) orange, where T = 4 hours.
The algorithm outcomes for each scenario included:9,10
• Number and placement of CD4 laboratories and POC sites.
• Euclidian distances from the health facility cluster to the allocated CD4 laboratory.
• Daily test volumes for CD4 laboratories.
Distribution of laboratory test volumes
For each scenario, daily laboratory testing volumes were reported using a line chart. The dataset was sorted from the highest to lowest test volumes, and current daily volumes for 2015 were also reported.
Analysis of platform and space requirements for the 10 busiest laboratories for each scenario
The top 10 laboratories with the highest daily volumes for each scenario were used to assess the appropriate:
• platform to be deployed, i.e. XL MCL or Cellmek/MPL
• number of platforms required to provide sufficient instrument capacity
• bench space required to accommodate platform(s) based on the supplier width recommendations: for example, the Cellmek requires a bench depth of 1.2 m, which includes the computer, monitor, bottles, cables and tubing.
Additionally, the percentage increase in daily testing volumes from current annual volumes (2015) was assessed.
Results
Spatial representation of RACL algorithm output for each scenario
For scenario A, (T = 4), testing would be offered using a fully-centralised approach with only 15 CD4 laboratories (Figure 3 and Table 1). Additionally, CD4 testing would be introduced at the Springbok, Upington and Vredenburg laboratories to meet a T of four hours in the Northern Cape, Western Cape and North West provinces.9
In scenario B (T = 3), the majority of the testing would be performed by Tier 4 (n = 24) and Tier 5 (n = 6) laboratories with POC reserved for hard-to-reach areas.19
The decentralised scenario C (T = 2) would increase CD4 laboratories to 61, with 20 POC sites.
Distribution of CD4 laboratories
For scenario A (T = 4), only 15 CD4 testing laboratories are required to ensure equitable access with no POC sites required.99
Distribution of laboratory daily volumes
For scenario A, there would be a significant increase in daily test volumes, with one laboratory required to increase capacity four-fold (Figure 4).9
Daily laboratory test volumes peak at 1142 in scenarios B and 992 in scenario C. These would necessitate two Cellmek/MPL systems. An additional requirement for scenario C is lower-throughput CD4 platforms for laboratories performing between 11 and 50 tests per day (n = 8 Tier 3 laboratories).
Analysis of platform and space impact for the 10 busiest laboratories for each scenario
In scenario A, four laboratories would be required to increase throughput between 87% and 305% (Table 2). At the busiest laboratory, this equates to allocating up to 27 metres of bench space to cope with a daily volume of 3541. To ensure adequate coverage, centralisation is paired with low-volume decentralised laboratories, leaving five laboratories to perform less than 40 samples per day (Tier 2).
For scenario B, the top 10 laboratories are required to make minor changes to their throughput ranging between 5% and 38%. Additionally, the required bench space varies from 5.27 to 13.56 metres. In scenario C, similar increases in throughput are reported at busier laboratories. However, decentralised POC testing reduces volume daily volumes for laboratories 9 and 10.
Discussion
The RACL algorithm outcomes reported an inverse relationship between T and the numbers of CD4 laboratories/POC sites required to provide coverage. This indicates that the number of CD4 laboratories required to ensure coverage would increase with a decreasing T. As T is increased, it would be possible to ensure coverage with fewer laboratories. The key would be to establish a T that could deliver a clinically-acceptable TAT in line with the standard of care. The current South African guidelines require a CD4 count within seven days to fast-track patients ≤ 200 cells/µL.11
The RACL algorithm was repeated for each of three travel times (4, 3 and 2 hours), based on a required TAT of 24 hours. Each scenario provides a solution to address coverage based on a clinically-accepted TAT.
Scenario A represents a highly-centralised model that requires efficient logistics to achieve a T of four hours. The benefits of centralised testing include improved cost efficiency as well as improved testing quality with fewer laboratories.8
Scenario B offers a mix of predominantly laboratory-based CD4 testing with limited POC testing in 'hard-to-reach' areas. Several new CD4 testing sites at existing NHLS laboratories identified have already been implemented by the NHLS. Many of these rural laboratories require limited testing capacity and were therefore identified as Tier 3 laboratories by the ITSDM. A good example is the De Aar laboratory that was implemented in 2012. This laboratory was able to cope with testing demand and reduce TAT substantially from 20.5 to 8.2 hours.7n = 20 samples).78
Additional analysis was performed for the National Health Insurance pilot districts (n = 11) to assess service gaps.1212
In scenario C, testing is extended to 61 laboratories with 20 POC sites. Many of the POC sites proposed would be within an acceptable T if a Tier 2 site (POC hub) were established in Calvinia. Furthermore, a Tier 2 site would serve multiple health facilities and offer access to multiple tests (CD4, Xpert MTB/RIFTM, creatinine, alanine transaminase and haemoglobin/full blood count).18
Across the three scenarios, laboratory-based CD4 testing varies between 15 and 61 sites. For scenario A and B, between 18 to 44 existing CD4 laboratories would have to be consolidated, resulting in significant changes to sample logistics, equipment and staff allocation. Reducing a platform of 62 laboratories to 15 would require a massive scale-up to cope with increased test volumes. This would include a scale-up in the pre-analytical section as well and could incur both renovation and verification costs. Consolidation would require staff to relocate to urban areas; this would need to be handled using a change management approach with additional costs. Additionally, samples would have to travel further, increasing per kilometre logistics costs.
In summary, the RACL algorithm identified the optimal placement of NHLS laboratories for a range of T to enable the delivery of a CD4 service that balances the need for equitable access and cost-effectiveness. However, evidence from the pilot tier 3 laboratory demonstrates that additional tier 3 laboratories or tier 2 POC hubs could increase coverage in a more cost-effective manner than POC sites.
Limitations
Travel times reported are based on a representative sample of Google® Maps Directions drive times. The drive time for all health facility clusters could not be obtained due to funding availability. Therefore, travel times could be underestimated in areas with poor road infrastructure resulting in additional coverage gaps requiring additional testing sites and/or POC. The RACL algorithm would have to be rerun should any of the assumptions change, namely, TAT, number of health facilities and test volumes. It would be difficult to provide a statistical analysis of the data presented by the RACL algorithm, such as a list of proposed laboratories/POC sites. Additionally, an assessment of local conditions must accompany the findings of the RACL algorithm to ensure optimal coverage.
Recommendations
Based on the results of this study, it is recommended that the RACL algorithm be implemented on the corporate data warehouse to enable real-time analysis of coverage gaps. The limitations of using Google's drive times should be addressed. Additionally, the algorithm should be extended to include other priority tests, such as Xpert MTB/RIF®, HIV viral load, HIV DNA PCR and pap smear.
Conclusion
The RACL algorithm provides laboratory management with an objective methodology to identify and address coverage gaps. However, the algorithm outcomes must be assessed in conjunction with local knowledge to address coverage gaps using a sustainable approach.
Competing Interests
The authors declare that they have no financial or personal relationships which may have inappropriately influenced them in writing this article.
Sources of support
None.
Authors'
contributionsH.S. developed the mathematical model, conceived the RACL algorithm and developed the computer systems to display the model outcome spatially. D.K.G., N.C. and L.M.C. assisted with input parameters for the model and evaluation of model output. D.K.G., N.C. and L.M.C. conceived the analysis of the impact of implementing the algorithm outcomes on test volumes, platform distribution and space requirements. All authors contributed to the manuscript development.
Acknowledgements
The authors thank Wendy Stevens, Sergio Carmona, Jon Smith, Sherry Drury and Sithembile Mojalefa.
References
-
1. Glencross DK, Coetzee LM, Cassim N. An integrated tiered service delivery model (ITSDM) based on local CD4 testing demands can improve turn-around times and save costs whilst ensuring accessible and scalable CD4 services across a national programme. PLoS ONE 9(12): e114727. http://doi.org/10.1371/journal.pone.0114727
» http://doi.org/10.1371/journal.pone.0114727 - 2. Coetzee LM, Cassim N, Glencross DK. A cost analyses of mobile laboratory CD4 testing in a National Health Insurance (NHI) pilot site. Poster presented at the First International Conference of the African Society for Laboratory Medicine, Cape Town, South Africa; 2012.
- 3. Glencross DK, Janossy G, Coetzee LM, et al. Large-scale affordable PanLeucogated CD4+ testing with proactive internal and external quality assessment: in support of the South African national comprehensive care, treatment and management programme for HIV and AIDS. Cytometry B Clin Cytom. 2008;74(Suppl 1):S40-S51.
- 4. Glencross DK, Scott LE, Jani IV, et al. CD45-assisted PanLeucogating for accurate, cost-effective dual-platform CD4+ T-cell enumeration. Cytometry. 2002;50(2):69-77.
-
5. World Health Organization. Guide for national public health laboratory networking to strengthen integrated disease surveillance and response (IDSR) [document on the Internet]. c2008 [cited 2016 July]. Available from: http://www.cdc.gov/globalhealth/healthprotection/idsr/pdf/htl-afro-cdc-lab-guidelines-for-nln.pdf
» http://www.cdc.gov/globalhealth/healthprotection/idsr/pdf/htl-afro-cdc-lab-guidelines-for-nln.pdf -
6. National Health Laboratory Service. NHLS strategic plan 2010-2015 [document on the Internet]. c2010 [cited 2016 July]. Available from: http://www.nhls.ac.za/assets/files/NHLS_Strategic_Plan_2010-15%20for_DOH.pdf
» http://www.nhls.ac.za/assets/files/NHLS_Strategic_Plan_2010-15%20for_DOH.pdf -
7. Coetzee L, Cassim N, Glencross D. Implementation of a new 'community' laboratory CD4 service in a rural health district in South Africa extends laboratory services and substantially improves local reporting turnaround time. S Afr Med J. 2015;106(1):82-87. http://doi.org/10.7196/SAMJ.2016.v106i1.10081
» http://doi.org/10.7196/SAMJ.2016.v106i1.10081 -
8. Cassim N, Coetzee LM, Schnippel K, et al. Estimating implementation and operational costs of an integrated tiered CD4 service including laboratory and point of care testing in a remote health district in South Africa. PloS One. 2014;9(12):e115420. http://doi.org/10.1371/journal.pone.0115420
» http://doi.org/10.1371/journal.pone.0115420 - 9. Smith J, Smith H, Cassim N, et al. Geographic location and capacity optimisation modelling to plan effective and efficient diagnostics service placement. Paper presented at the First International Conference of the African Society for Laboratory Medicine, Cape Town, South Africa; 2012.
- 10. Smith HK, Smith JP, Glencross DK, et al. Siting of HIV/AIDS diagnostic equipment in South Africa: a case study in locational analysis. Int T Oper Res. 2017;1-35.
- 11. National Department of Health. National consolidated guidelines for the prevention of mother-to-child transmission of HIV (PMTCT) and the management of HIV in children, adolescents and adults. Pretoria, South Africa; 2015.
- 12. Coetzee LM, Cassim N, Glencross DK. Using the tiered service approach to assess gaps in laboratory service delivery in the eleven pilot districts of the National Health Insurance (NHI). Poster presented at the First International Conference of the African Society for Laboratory Medicine, Cape Town, South Africa; 2012.
Accepted: 16 Sept. 2016
Published: 28 Feb. 2017