Servicios Personalizados
Revista
Articulo
Indicadores
Links relacionados
-
Citado por Google -
Similares en Google
Compartir
Southern African Journal of Critical Care (Online)
versión On-line ISSN 2078-676Xversión impresa ISSN 1562-8264
South. Afr. j. crit. care (Online) vol.42 no.1 Pretoria abr. 2026
https://doi.org/10.7196/sajcc.2026.v412i1.2816
RESEARCH
Fluid tolerance in septic shock: Femoral vein pulsatility versus VExUS score in a cross-sectional study
M A SahbalI; A A HemedaII; S FawzyI; S GaberI
IMB BCh, MMed (Crit Care); Department of Critical Care Medicine, Cairo University, Giza, Egypt
IIMB BCh, MMed (Int Med); Department of Internal Medicine, Cairo University, Giza, Egypt
ABSTRACT
BACKGROUND: Excessive fluid resuscitation in patients with septic shock is associated with acute organ injury and increased mortality. Accurate assessment of fluid tolerance is therefore essential. Right cardiac chamber fluid tolerance can be evaluated by estimating the right atrial pressure using central venous catheters, inferior vena cava (IVC) measurements, Venous Excess Ultrasound (VExUS) scores and femoral vein pulsatility (FVP).
OBJECTIVES: To assess the correlation between FVP and VExUS score in evaluating fluid intolerance and venous congestion in patients with septic shock; the correlation of FVP and VExUS score with central venous pressure (CVP); and to evaluate the effect of positive pressure ventilation on the relationship between FVP and VExUS score.
METHODS: In this observational cross-sectional study, 80 participants were assessed for fluid tolerance using VExUS scores and FVP. CVP, maximum and minimum IVC diameters and IVC dynamicity were regarded as the gold standard and used as reference.
RESULTS: FVP showed moderate agreement with VExUS score (Kappa=0.55; p<0.001). Both FVP and VExUS score demonstrated the ability to predict CVP values ≥17 cmH2O with overall accuracies of 70% and 77.5%, respectively (p<0.001). A CVP ≥17.5 cmH2O predicted severely congested femoral veins with a sensitivity of 70% and specificity of 90%, whereas a CVP ≥18.5 cmH2O predicted VExUS grade 3 with a sensitivity of 66.7% and specificity of 83.3%. Maximum IVC diameter accurately predicted abnormal femoral vein Doppler findings, with an overall accuracy of 82.5%.
CONCLUSION: A pulsatile femoral vein pattern indicates fluid intolerance in patients with septic shock, providing an additional marker for assessing fluid status. Doppler assessment of the femoral vein offers advantages of easier anatomical accessibility and a shorter learning curve compared with other methods.
Keywords: venous congestion, VExUS score, femoral vein pulsatility, central venous pressure, inferior vena cava, fluid management, monitoring, septic shock
In patients with septic shock, fluid therapy remains a cornerstone of management to restore and maintain tissue perfusion, as recommended by the 2024 Surviving Sepsis Campaign guidelines.[1] However, many studies have correlated excessive fluid resuscitation with increased rates of acute organ injury, prolonged duration of positive pressure ventilation (PPV) and increased mortality.[2] Consequently, finding accurate methods of assessing fluid status in critically ill patients is essential.
Fluid administration in critically ill patients is guided by the concepts of fluid responsiveness and fluid tolerance. Fluid responsiveness is defined as the ability of the left ventricle to increase stroke volume in response to preload augmentation, whereas fluid tolerance represents the body's capacity to tolerate intravenous fluids without developing venous congestion or organ dysfunction.[3] Fluid tolerance is assessed by evaluating cardiac chamber filling pressures.[4] Right atrial pressure (RAP) may be measured invasively through the insertion of a Swan-Ganz catheter or central venous catheter (CVC).[5] Echocardiographic assessment of the inferior vena cava (IVC) respiratory dynamicity is another simple, reproducible tool to estimate RAP.[6] The Venous Excess Ultrasound (VExUS) score is a recently validated protocol comprising assessment of the IVC, hepatic, portal and renal veins to reflect RAP.[7] However, the requirement for experienced operators, time-consuming methodology and difficult anatomical accessibility pose limitations to the acceptance of the VExUS score in critical care settings.[8]
Femoral vein pulsatility (FVP) is an emerging tool for predicting volume overload and has been shown to correlate with RAP.[9-11] This study aimed to compared FVP with VExUS score in assessing fluid tolerance in patients with septic shock.
Methods
This observational cross-sectional study was conducted over a 7-month period from October 2023 to May 2024. All patients with septic shock admitted to the Critical Care Department of Cairo University Hospitals during this period were consecutively enrolled, provided they met the inclusion criteria and none of the exclusion criteria.
Eligible patients were identified according to the definition of septic shock provided by the Third International Consensus for Sepsis and Septic Shock.[12] Both patients with a first episode of septic shock and those with recurrent episodes were included. Each participant was assessed once during their intensive care unit (ICU) stay.
The study was approved by the Ethical Research Committee of the Faculty of Medicine, Cairo University (ref. no. MS-458-2023), and written non-opposition consent was obtained.
Exclusion criteria included patients with an inadequate ultrasonographic window, raised intrathoracic or intra-abdominal pressure or those who were mechanically ventilated with positive end-expiratory pressure ≥8 cmH2O or tidal volume <6 mL/kg. Patients with portal hypertension, stage 4 or 5 chronic kidney disease or moderate to severe tricuspid regurgitation were also excluded. In addition, patients with septic shock who had IVC thrombosis or deep venous thrombosis of the lower limbs were not enrolled.
All enrolled participants were evaluated during their ICU stay in the same setting. Measurements included central venous pressures (CVP), VExUS scores and FVP. Sonographic recordings were performed using a GE Vivid iq portable ultrasound machine (GE Healthcare, Chalfont St Giles, UK).
Variables of interest
CVP. A water manometer was connected to internal jugular or subclavian CVCs. The manometer was aligned with the phlebostatic axis while patients were in the dorsal decubitus position. CVP was recorded at end-expiration. A CVP ≥17 cmH2O was regarded as volume overload, as supported in the literature.[8,13-15]
VExUS score. A 1.8 - 6.0 MHz curvilinear probe was used to assess VExUS score with the patient in the dorsal decubitus position. All pulsed-wave Doppler (PW Doppler) measurements were obtained at end-expiration with an angle of insonation <45° and optimised Doppler scale settings. The VExUS score was assessed according to the protocol described by Beaubien-Souligny et al.[7] (VExUS score prototype C). Scores ranged from grade 0 (absence of congestion) to grades 1 - 3, suggesting venous congestion.
FVP. With the patient in the dorsal decubitus position, a 2.4 - 10.0 MHz linear array probe was placed 2 - 3 cm below the midpoint of the inguinal ligament with an angle of insonation <45°. PW Doppler was used to record the waveforms over a single respiratory or ventilatory cycle. The following waveform patterns were defined:
(i) Normal pattern: Antegrade uninterrupted flow pattern with respiratory variation (Fig. 1).

(ii) Mild congestion: Triphasic pulsatile pattern representing the jugular venous pressure waveform (Fig. 2).

(iii) Severe congestion: Bidirectional pattern with flow reversal exceeding one-third of the antegrade flow (Fig. 3). [12]

Statistical methods
Data were coded and analysed using IBM SPSS Statistics version 28 (IBM Corp., USA). Quantitative data were summarised as mean and standard deviation (SD) or median with minimum and maximum values, as appropriate. Categorical data were summarised as frequencies and percentages. Categorical data were compared using either the χ2 or Fisher's exact test. Standard diagnostic indices included sensitivity, specificity, positive predictive value, negative predictive value and diagnostic efficacy. Receiver operating characteristic (ROC) curves were constructed, and the area under the curve (AUC) was calculated to detect the optimal cut-off values of CVP for detecting abnormal VExUS scores and femoral vein Doppler findings. A p-value <0.05 was regarded as statistically significant.
Objectives
The primary objective was to assess the correlation between FVP and VExUS score in evaluating fluid tolerance and venous congestion in patients with septic shock, including both spontaneously breathing patients and those receiving invasive or non-invasive PPV.
Secondary objectives included assessing the correlation of FVP and VExUS score with CVP, and evaluating the effect of PPV on the relationship between FVP and VExUS score.
Results
A total of 113 patients with septic shock were screened for eligibility. After the exclusion of 33 patients, 80 were enrolled in the study, of whom 55% were male. The mean (SD) age was 60.18 (17.52) years. All patients were receiving vasopressor treatment, and 40% were receiving PPV.
Primary objective: FVP v. VExUS score
Among patients with a VExUS score of 0, 73.9% showed a normal FVP, whereas 82.4% of patients with VExUS scores suggestive of congestion (grades 1 - 3) showed abnormal FVP.
FVP demonstrated moderate agreement with the VExUS score in both spontaneously breathing patients and those receiving invasive or non-invasive PPV, with a Kappa value of 0.55 and an overall agreement of 77.5% (Table 1).
Secondary objectives
Both FVP and VExUS scores showed significant correlation with CVP values (p<0.001).
CVP v. FVP
Abnormal FVP (suggestive of mild or severe congestion) was associated with a mean (SD) CVP of 15.20 (5.01) cmH2O. FVP demonstrated the ability to predict whether CVP values were above or below 17 cmH2O with an overall accuracy of 70% (AUC 0.870; p<0.001) (Table 2). A normal FVP predicted a CVP of ≤9.5 cmH2O (AUC 0.775; p<0.001) with a sensitivity of 70% and specificity of 75%. A severely congested FVP predicted a CVP of ≥17.5 cmH2O (AUC 0.895; p<0.001) with a sensitivity of 70% and specificity of 90%.
CVP v. VExUS
VExUS scores suggestive of congestion (grades 1 - 3) were associated with a mean (SD) CVP of 16.06 (4.95) cmH2O. The VExUS score predicted whether the CVP values were above or below 17 cmH2O with an overall accuracy of 77.5% (AUC 0.891; p<0.001) (Table 3). Abnormal VExUS scores were detected in all patients with a CVP ≥17 cmH2O, whereas 71.9% of patients with a normal VExUS score (grade 0) had a CVP <17 cmH2O. A grade 2 VExUS score predicted a CVP ≥13.5 cmH2O with a sensitivity of 66.7% and specificity of 60%, and a grade 3 VExUS score predicted a CVP ≥18.5 cmH2O with a sensitivity of 66.7% and specificity of 83.3%.
IVC and VExUS score
VExUS score grades showed a strong association with various IVC measurements, as shown in Supplementary Table 1.
IVC and FVP
FVP was also significantly correlated with the ultrasonographic measurements of the IVC, as shown in Supplementary Table 2.
Discussion
The aim of this study was to assess the correlation between VExUS score and FVP in estimating venous congestion and fluid tolerance in patients with septic shock. Few studies have explored this association. Our findings revealed that the common femoral vein (CFV) pulsatility demonstrated moderate agreement with VExUS score (Kappa=0.55). This may be explained by the anatomical relationship between the CFV - particularly the right CFV - and the IVC and right atrium, whereby flow derangements may be noted along this axis.9
In agreement with our results, Bhardwaj et al.[13] similarly concluded that the accuracy of VExUS scores and FVP in estimating volume overload was 80.37% and 74.7%, respectively, in a cohort of post-cardiac surgical ICU patients. The level of agreement between FVP and VExUS score in that study was also moderate (Kappa=0.62).
Andrei et al.[16] conducted a study involving 108 ICU patients, of whom 14% had septic shock and approximately 60% were mechanically ventilated. Similar to our findings, they also demonstrated a statistically significant association between FVP and VExUS score in estimating volume overload (p=0.001), with an odds ratio of 2.1 (95% confidence interval (CI) 1.4 - 3.4).
Our results demonstrated that FVP can reliably predict elevated CVP ≥17cmH2O with a sensitivity of 100% and specificity of 62.5%. In addition, a normal FVP predicted a CVP ≤9.5 cmH2O with a sensitivity of 70% and specificity of 75%, while a severely congested FVP predicted a CVP ≥17.5 cmH2O with a sensitivity of 70% and specificity of 90%.
The stronger association between FVP and VExUS score compared with CVP values may be due to the anatomical and physiological continuity between the CFV and the IVC, the latter being a key component of the VExUS scoring system.
Cozcolluela et al.[17] also demonstrated a statistically significant correlation between FVP and CVP. In their study, FVP predicted a CVP >8 cmH2O with a specificity of 82.39%, accuracy of 75% and sensitivity of 59.7%.
In our study, the higher predictability and sensitivity of FVP for elevated CVP values may be attributed to the higher CVP cut-off threshold (≥17 cmH2O), which likely reduced the number of false-negative cases. Furthermore, assessing CVP and FVP within the same setting may have been a contributing factor.
Similarly, Alimoğlu et al.[18] reported that the sensitivity of FVP for estimating a RAP ≥10.88 cmH2O was 70%, with a specificity of 92%, positive predictive value of 92% and negative predictive value of 70%.
To our knowledge, our study was the first to demonstrate that a CVP ≥13.5 cmH2O predicted a grade 2 VExUS score with a sensitivity of 66.7% and specificity of 60%, while a CVP ≥18.5 cmH2O predicted a grade 3 VExUS score with a sensitivity of 66.7% and specificity of 83.3%.
The statistically significant association between VExUS score and CVP observed in our study is consistent with the findings of Beaubien-Souligny et al.,[7] in which the VExUS model demonstrated a statistical correlation with CVP (p=0.004).
In concordance with our findings, Muñoz et al.[19] reported a statistically significant association (p=0.047) between abnormal VExUS score (grades 1 - 3) and elevated CVP (≥16 cmH2O) in a cohort of critically ill mechanically ventilated patients receiving intravenous vasopressors.
Conclusion
Our findings conclude that FVP demonstrates moderate agreement with VExUS score. In addition, given its ease of use and anatomical accessibility, Doppler assessment of the femoral vein may represent a promising tool for the evaluation of fluid tolerance and status in critically ill patients with septic shock. However, the ability of FVP to predict lower CVP values - potentially important for preventing fluid accumulation syndrome - requires further investigation. Further studies are needed to refine methods for assessing fluid tolerance in critically ill patients.
Limitations
This study did not evaluate right ventricular function or its potential influence on the correlation between VExUS score and FVP.
In addition, CVP was used as one of the gold reference standards for assessing venous congestion. This approach has recognised limitations and potential confounding factors. Nevertheless, CVP remains one of the most commonly used informative clinical measures for assessing fluid tolerance and status in critically ill patients.
The use of CFV pulsatility as a method for assessing volume status also has several pitfalls and limitations.
Many critically ill patients encountered daily by intensivists in routine clinical practice may meet one or more of the exclusion criteria outlined in the methods section, which limits the applicability of femoral vein Doppler assessment in such settings and may render it inaccurate.
Declaration. None.
Acknowledgements. None.
Author contributions. Equal contributions.
Funding. None.
Conflicts of interest. None.
References
1. Evans L, Rhodes A, Alhazzani W, et al. Surviving sepsis campaign: International guidelines for management of sepsis and septic shock 2021. Intensive Care Med 2021;47(11):1181-1247. https://doi.org/10.1007/s00134-021-06506-y [ Links ]
2. Galindo P, Gasca C, Argaiz ER, Koratala A. Point of care venous Doppler ultrasound: Exploring the missing piece of bedside hemodynamic assessment. World J Crit Care Med 2021;10(6):310-322. https://doi.org/10.5492/wjccm.v10.i6.310 [ Links ]
3. Joseph A, Petit M, Vignon P, Vieillard-Baron A. Fluid responsiveness and venous congestion: Unraveling the nuances of fluid status. Crit Care 2024;28(1):140. https://doi.org/10.1186/s13054-024-04930-2 [ Links ]
4. Melo RH, dos Santos MHC, da Silva Ramos FJ. Beyond fluid responsiveness: The concept of fluid tolerance and its potential implication in hemodynamic management. Crit Care Sci 2023;35(2):226-229. https://doi.org/10.5935/2965-2774.20230012-en [ Links ]
5. Chen Y, Shlofmitz E, Khalid N, et al. Right heart catheterization - Related complications: A review of the literature and best practices. Cardiol Rev 2020;28(1):36-41. https://doi.org/10.1097/crd.0000000000000270 [ Links ]
6. Rola P, Haycock K, Spiegel R. What every intensivist should know about the IVC. J Crit Care 2024;80:154455. https://doi.org/10.1016/j.jcrc.2023.154455 [ Links ]
7. Beaubien-Souligny W, Rola P, Haycock K, et al. Quantifying systemic congestion with point-of-care ultrasound: Development of the venous excess ultrasound grading system. Ultrasound J 2020;12:16. https://doi.org/10.1186/s13089-020-00163-w [ Links ]
8. Longino A, Martin K, Leyba K, et al. Correlation between the VExUS score and right atrial pressure: A pilot prospective observational study. Crit Care 2023;27(1):205. https://doi.org/10.1186/s13054-023-04471-0 [ Links ]
9. Denault AY, Aldred MP, Hammoud A, et al. Doppler interrogation of the femoral vein in the critically ill patient: The fastest potential acoustic window to diagnose right ventricular dysfunction? Crit Care Explor 2020;2(10):209. https://doi.org/10.1097/cce.0000000000000209 [ Links ]
10. Calderone A, Hammoud A, Jarry S, Denault A, Couture EJ. Femoral vein pulsatility: What does it mean? J Cardiothorac Vasc Anesth 2021;35(8):2521-2527. https://doi.org/10.1053/j.jvca.2021.03.021 [ Links ]
11. Dandu C, Dobesh K, Grewel A, Natour A, Kabbani L, Ahsan S. Lower extremity venous pulsatility is associated with elevated pulmonary artery pressures and tricuspid regurgitation. J Vasc Surg Venous Lymphat Disord 2023;11(2):460. https://doi.org/10.1016/j.jvsv.2022.12.041 [ Links ]
12. Singer M, Deutschman CS, Seymour CW, et al. The third international consensus definitions for sepsis and septic shock (Sepsis-3). JAMA 2016;315(8):801-810. https://doi.org/10.1001/jama.2016.0287 [ Links ]
13. Bhardwaj V, Rola P, Denault A, Vikneswaran G, Spiegel R. Femoral vein pulsatility: A simple tool for venous congestion assessment. Ultrasound J 2023;15:24. https://doi.org/10.1186/s13089-023-00321-w [ Links ]
14. Gupta B, Ahluwalia P, Gupta A, Ranjan N, Kakkar K, Aneja P. Utility of VExUS score in the peri operative care unit, intensive care unit, and emergency setting - A systematic review. Indian J Anaesth 2023;67(Suppl 4):S218-S226. https://doi.org/10.4103/ija.ija_475_23 [ Links ]
15. Menéndez-Suso JJ, Rodríguez-Álvarez D, Sánchez-Martín M. Feasibility and utility of the venous excess ultrasound score to detect and grade central venous pressure elevation in critically ill children. J Ultrasound Med 2023;42(1):211-220. https://doi.org/10.1002/jum.16057 [ Links ]
16. Andrei S, Bahr PA, Alissant M, et al. Pulsatile femoral vein Doppler pattern is a parameter of venous congestion in ICU patients. J Cardiothorac Vasc Anesth 2023;38(6):1361-1368. https://doi.org/10.1053/j.jvca.2023.04.028 [ Links ]
17. Cozcolluela MR, Sarría L, Sanz L, et al. Correlation of central venous pressure with Doppler waveform of the common femoral veins. J Ultrasound Med 2000;19(8):587-592. https://doi.org/10.7863/jum.2000.19.8.587 [ Links ]
18. Alimoğlu E, Erden A, Gürsel K, Olçer T. Correlation of right atrial pressure and blood flow velocities in the common femoral vein obtained by duplex Doppler sonography. J Clin Ultrasound 2001;29(2):87-91. https://doi.org/10.1002/1097-0096(200102)29:2%3C87::aid-jcu1003%3E3.0.co;2-1 [ Links ]
19. Muñoz O, Ferrusquía-Acosta J, Serna-Patiño LM, Cárdenas A. Diagnostic methods of portal hypertension. Revi Colomb Gastroenterol 2021;36(2):218-226. https://doi.org/10.22516/25007440.692 [ Links ]
Correspondence:
M Adel Sahbal
dr.maiadelsahbal@gmail.com
Received 11 November 2024
Accepted 29 September 2025
Contribution of study
This study evaluated a simple rapid tool (femoral vein pulsability) in assessing volume state and fluid tolerance in septic patients in comparison with VExsus.












