    Efficacy of GapSeal® in Preventing Microleakage at the Dental Implant Abutment Interface

     

     

    H BadiI; E MabozaII; A JefthaIII

    IDept Oral Medicine and Periodontology, Faculty of Dentistry. University of the Western Cape, South Africa. ORCID ID 0009-0001-9007-1501
    IIOral and Dental research laboratory. Faculty of Dentistry, University of the Western Cape, South Africa. ORCID ID 0000-0003-0910-5899
    IIIDept Oral Medicine and Periodontology, Faculty of Dentistry. University of the Western Cape, South Africa. ORCID ID 0000-0003-0572-6591

    Correspondence

     

     


    ABSTRACT

    INTRODUCTION: Dental implants have proven to be a success, however the microleakage at the implant-abutment interface is still a major concern. Suggested measures to decrease microleakage include the application of silicone sealing gels, such as GapSeal®.
    AIMS AND OBJECTIVES: To test the ability of GapSeal, in preventing microleakage at the implant-abutment interface of internal hexagon design dental implants, under dynamic loading.
    DESIGN: In-vitro experimental study.
    METHODS: 30 dental implants were equally divided into 2 groups: one group had GapSeal (GS) added and the other group had none (GN). The implants were connected to their adjacent abutments and microbiological analysis was done by immersing the implant assembly in Streptococcus sanguinis inoculated BHI suspension. The implants were subjected to dynamic forces of 80 N at 1 Hz for 200,000 cycles in a chewing simulator. They were then dismantled and samples from the implants' interiors were obtained and cultured on agar plates incubated for 24 hours. Finally, colony forming units were recorded.
    RESULTS: Significant difference (Levene's test of variances p=0.006) in the number of CFU/ml in GS group compared to GN group, with the mean CFU/ml of GS group (10.21) being less than the GN group (87.79).
    CONCLUSIONS: Application of GapSeal to the implants interiors was effective in reducing microleakage at the implant abutment interface, under dynamic loading. However, it did not completely prevent it.

    Keywords: GapSeal, Implant Abutment Interface, Microleakage, Dynamic Loading, Chewing Simulator


     

     

    Abbreviations

    IAI: Implant Abutment Interface

    BHI: Brain Heart Infusion

    CFU: Colony Forming Units

     

    INTRODUCTION

    With success rates higher than 90%, dental implants are one of the best rehabilitation methods in modern dentistry.1 Nevertheless, microleakage that occurs at the microgap in the implant abutment interface (IAI) is still a concerning factor for implants' success.2 Dental implant systems generally consist of two main components: a fixture inserted surgically into the alveolar bone and a transmucosal abutment,3 which inevitably creates a microgap between the implant fixture and abutment.4,5 Chewing causes a pumping action that allows the influx of fluids and bacteria into the microgap,6 even in clinically healthy conditions.7 The interior well of the implant becomes a reservoir for microorganisms and their metabolic products which affect the periodontal tissues directly and are capable of migrating in a bidirectional manner.5 Tissues adjacent to the IAI can subsequently present with a marked infiltration of inflammatory substances regardless of the accumulation of plaque present.8

    Microleakage can interfere with osseointegration in the healing phase of the surgical intervention, and it can result in an inflammatory reaction and a host response in the peri-implant soft tissues which can lead to bone loss and peri-implantitis.5,8,9 Microleakage can also cause abutment screw loosening as a consequence of the lubricous environment created by the microbial activities.10

    The type of implant abutment connection used plays a crucial part in microleakage.8 Internal hexagon connections showed less microleakage in comparison with external connections,8 however microleakage still occurred regardless of the implant abutment connection used.11 Numerous studies showed that microbial leakage cannot be completely prevented even in contemporary implant system designs.12,13

    Studies deduced that masticatory loads can cause an increase in microgap size due to micromovements in the prosthetic components,14 and cause a so-called pumping effect,6,14 which increases the susceptibility of the implant systems to microleakage.15,16 Dynamic loading also causes deterioration of the IAI over time.15 Therefore, it is proposed that testing microleakage under dynamic loading be a standard step in all future in-vitro studies conducted.16

    There has been an increased interest in testing the use of sealing materials at the IAI to reduce or perhaps even prevent microbial leakage at the IAI. Studies tested the use of different sealing materials including chlorhexidine gel,18,19 Atridox19 and GapSeal.19-23 GapSeal® (Hager & Werken, Duisburg, Germany) is a sealing gel added on a highly viscous silicone matrix with 5% weight of thymol,24 and showed promising results in reducing microleakage and decreasing microgap size.19-23 However, not enough studies were conducted testing the effectiveness of GapSeal under dynamic forces, in internal hexagon connections, thus this study was conducted.

     

    MATERIALS AND METHODS

    Closing Torque Procedure

    A total of 30 dental implants (SEVEN MIS design, internal hexagon, standard platform) (MIS Implants Technologies Ltd, Haifa, Israel) and their corresponding abutments were utilized in this study, after consultation with the statistician and considering the cost effectiveness. Each dental implant was stabilized and held upright with autopolymerizing resin, prepared according to the manufacturer's instructions, in custom-made, polytetrafluoroethylene (PTFE) test chambers. This was done to create a compartment for the bacterial solution and to standardize the volume used for each implant assembly. The resin also helped in mimicking the intraoral environment in which some forces transported to the IAI would be absorbed by the bone.25 The dental implants and their respective abutments were then put in sterilization pouches, assigned codes and sent for gas sterilization.

    The dental assemblies were divided into two groups of 15 Implants each: Group GS had GapSeal applied to the internal aspect of the implant fixture prior to abutment connection while group GN implants had none applied. The GapSeal was added to the maximum capacity of the internal aspect of the implant fixture according to the manufacturer's instructions to prevent air entrapment. GapSeal was applied using an applicator provided by the manufacturer and sterilized before every use. Subsequently, each implant was carefully connected to its corresponding abutment using a sterile torque wrench, at 30 Ncm according to the manufacturer's guidelines. All dental assemblies were handled by one operator, in sterile conditions in a laminar flow chamber.

    Bacterial Culture Preparation

    Streptococcus sanguinis, a gram positive, facultative anaerobic bacterium is amongst the primary colonizers in the oral cavity. It attaches directly to oral surfaces and even more to titanium than other bacteria.26 It has a relatively small size, 0.5-1.0μηι,27 and is capable of adhering to implant titanium surfaces, irreversibly,28 as well as facilitating the adherence of secondary microbial colonizers.29 S. sanguinis was cultured using the direct colony suspension method. The bacterial inoculum was then extracted from the incubated culture and diluted in 2 ml of PBS and adjusted to 0.5 McFarland standard (~1.5x 10Λ8 CFU/ml), using DensiCHEK. The 2 ml of inoculated PBS was then added to 2 ml of sterile BHI and mixed well using a vortex mixer for 5 seconds. This was the final inoculated BHI solution used for testing the microbial leakage.

    Dynamic Loading

    All implant assemblies from each group were then placed in the custom-made PTFE chambers and mounted in the chewing simulator. 2 ml of the inoculated BHI was transferred to the chamber of 28 of these assemblies, using a sterile pipette. This volume of solution was adequate to guarantee that the IAI was fully immersed, but not the screw opening. This was to ensure that if leakage occurred, it would be due to leakage through the IAI and not from the screw opening. 1 implant assembly from Group GS and 1 from Group GN had 2 ml of sterilized BHI solution added to their test chambers instead of the inoculated BHI. This served as a negative control that ensured any microleakage into the implant was from the inoculum and not a result of external contamination.

    The chewing simulator (CS-4, SD Mechatronik, Germany) housed two implants at the same time (Figure 4-5). A cyclic fatigue load of 80 N was applied for a total of 200,000 cycles at 1 Hz to each implant assembly with a sterile round stainless-steel stylus in the axial direction. 200,000 cycles were completed in around the 24 hour time frame which took into consideration the S. sanguinis livelihood. The chewing simulator operated via a computer program, therefore it calibrated automatically once the parameters mentioned above were input. The chewing simulator and its components were disinfected before and after every complete set of cycles.

    Measuring Bacterial Colonies

    After the completion of the chewing cycle, the assemblies were removed from the test chambers using sterile pliers, sprayed with 70% alcohol and positioned vertically for 10 minutes until the alcohol evaporated. The assemblies were carefully disconnected in a disinfected laminar flow chamber, using a sterile torque wrench. A sample for testing bacterial contamination from the inside of each implant was taken using sterile paper points. The paper points were then immersed in 1000 μ! of sterile BHI in sterilized eppendorf tubes, labelled with the implant code, and placed in an incubator at 37 °C for 20 minutes.

    Serial dilution was performed for each sample. 200 μl was pipetted from the eppendorf tube and transferred to the wells in row A of the first three columns in the 96-well plate. Afterwards, 100 μl of PBS was added to the wells from row B of the first column to row H of the third column, using a multichannel pipette. The solution was then diluted by two-folds by adding 100 μl from the wells in row A to the wells in row B and so forth up to the wells in row H.

    10 μl was then transferred from the wells E1, E2 and E3, using a single channel pipette, spread on 3 individual labelled agar plates using a sterile hockey stick and then incubated at 37°C for 24 hours. After the complete incubation period, the CFU in the plates were measured by means of a colony counter (Gerber, Switzerland) and recorded. Individual colonies on the agar plates were tested for gram positive cocci to ensure S. sanguinis growth. The usually accepted range of CFU per plate is 30 to 300, where any number of colonies above 300 is considered too numerous to count and any less than 30 too few to count. However, in this study any CFU less than 30 were recorded.

    Data Collection and Analysis

    Each sample was coded to permit blind analysis. The data was collected by the same investigator, recorded in Microsoft Excel© spreadsheets (Microsoft Corporation, USA) and processed using various statistical analysis techniques. IBM SPSS Statistics Version 20 for Windows (SPSS©, Inc. Chicago, IL, USA) and Microsoft Excel 2010 (Microsoft Corporation, USA) were used for all the statistical analysis. Descriptive analysis, Levene's test for equality of variances and an independent t test were performed for analysis and a value of P < 0.05 considered statistically significant.

     

    RESULTS

    Evidence of bacterial leakage was observed in most GS group samples, with the exception of 2 samples (Table I), and in all connections of group GN (Table II). No bacterial growth was observed in the negative control of the GS group (Table I) or in the negative control of the GN group (Table II).

     

     

     

     

    For the description of data, mean values and standard deviations were calculated, shown in Table III.

     

     

    The data for both groups was subjected to statistical analysis using the Levene's test for equality of variances for comparison where a value of 5% (P < 0.05) was considered significant. The test resulted in a significant value of 0.006. Results of the test are shown in Table IV.

     

     

    The data obtained from both groups was compared by using an independent t-test. The results are shown in Table V.

     

     

    A comparison of the mean counts of S. sanguinis detected in the internal well of the implants in both groups is shown in Figure 4.

     

     

    DISCUSSION

    The present in-vitro experimental study was conducted to investigate the efficacy of GapSeal® in preventing microleakage at the implant abutment interface of internal hexagonal connection dental implants after exposure to dynamic loading. According to the results, it was determined that GapSeal® was successful in reducing microleakage significantly. The results showed that the mean CFU detected in the case group (GS) was 10.21, which was significantly less (p=0.006), than in the control group (GN) with a mean CFU of 87.79.

    Microleakage is stated to be dependent on multiple factors, including the geometry of the implant abutment connection and the final closing torque.29 Studies showed that in comparison to the external hexagon design, the internal connection designs produced superior sealing abilities at the IAI, with the Morse taper connection showing the least CFU within the implants. Nevertheless, none of the implant abutment connection designs was able to fully prevent microleakage.8,11,13 Internal hexagon connection dental implants were used to test the microleakage in the current study. They were connected at a torque of 30 Ncm in accordance with the manufacturer's guidelines, since studies showed that to acquire the best seal in the IAI, the manufacturer's torque recommendations should be followed strictly.8,30

    Studies showed that another factor affecting microleakage is the micromovement caused by dynamic loading which leads to a pumping effect and increased flow of fluids and bacteria into the implant.6,14 Increased microleakage under dynamic loading is stated to also be due to deterioration in the IAI and deformations to the threaded portion which may aid in loosening of the screw.15 Sahin and Ayyildiz (2014) established a two-way relationship between microleakage at the IAI and screw loosening, in which microleakage can cause screw loosening which increases the microgap which in turn increases microbial leakage.10 Mao et al. (2023) upon conducting a systematic review and meta analysis on in-vitro studies testing microleakage, concluded that testing bacterial leakage under dynamic loading should be a set standard in future studies.16 Steinebrunner et al. (2005) showed an implant-abutment connection mechanically failed at 172,800 cycles (120 N) of dynamic loading.25 The present study provided dynamic loading in a chewing simulator for 200,000 cycles with a magnitude of 80 N, considered within the physiologic ranges and in line with previous studies that employed dynamic conditions with magnitudes ranging from 15 N to 160 N and cycles between 200,000 to 1,200,000.31

    Different studies investigated microleakage with several methodologies.8,16 Studies investigated leakage either from the external environment to the internal part of the implant (inward method),21-23,31 or from the inner parts of the implants to the outside environment (outward method).32-34 The freehand inoculation of bacterial broth into the implant in the outward method, in addition to the lack of determination of the implant's internal volume could generate false-positive results.12,35 Moreover, higher precision from the operator is required to avoid possible contact with the borders of the implant, enabling the passage of bacteria into the external environment.35 When considering microleakage testing at the IAI with the inward testing procedure, the total immersion of implant assemblies in the testing liquid could lead to false-positive results owing to the potential penetration of the fluid through the abutment screw interface.35 In addition, assembling and disassembling the implant abutment complex in a sterile environment, and extracting a sample from inside the implant without cross contamination from the exterior aspect is considered a methodological challenge.12 This study tested microleakage using the inward method, and assembled and disassembled the implant systems in a laminar flow chamber for sterile conditions. Also, the exact volume of bacterial solution added was measured and was adequate to cover the IAI without submerging the abutment screw interface to avoid false positives. 1 implant from each group (GS and GN) was tested with sterile BHI to check for external contamination issues, and the results showed no bacterial growth in either implant after dynamic loading.

    Numerous qualitative and/or quantitative microleakage testing methods were tried, including turbidity analysis, checkerboard DNA-DNA hybridization, radiotracer technique, and microbial counting.8 This study used CFU counting since Do Nascimeto et al. (2012) concluded that the accuracy of conventional culture counting methods gave comparable results as that of DNA checkerboard hybridization testing methods.36

    Various methods of reducing microleakage were proposed, including the application of sealing materials,19,20 decontaminating the internal wall of the implant and using memory shape alloys.37 Gutta percha showed no success in prevention of microleakage,38 and silicone gel sheets were tested in-vivo and resulted in reduced microleakage after 90 days.39 Chlorhexidine gel was studied in-vitro18 and in-vivo40 and contradicting results were found. Ozdiler et al. (2018) performed a study on microleakage in internal conical connections under dynamic loading. 50 N force was applied for 500,000 cycles and the results deduced that the use of sealants such as chlorhexidine gel and silicone material decreased bacterial leakage at the IAI significantly, with no significant difference between the 2 materials.31 Yu et al. (2020) tested a silicone sealing gel in 3 different implant systems under dynamic loading of 20 N to 200 N, using the outward method with toluidine blue dye. They concluded that the gel enhanced the immediate fastening and anti-loosening performances of implant connections, and reduced the IAI microleakage and abutment screw thread abrasion.41

    Nayak et al. (2014) compared the effect of GapSeal® and O-Ring in microleakage using the inward method with Enterococcus bacteria, and concluded that GapSeal® application significantly reduced microbial leakage.20 However, their study was performed in static conditions which could lead to an underestimation of microleakage. Mohammadi et al. (2019) compared the use of Atridox, chlorhexidine and GapSeal® in preventing microleakage using the outward method with A. actinomycetemcomitans. They concluded that GapSeal® did not have an antimicrobial effect and was not successful in preventing microleakage, rather delaying it.19 Their study was performed under static conditions and only recorded turbidity but did not count colonies which gave more of a qualitative result. Smojver et al. (2022) compared GapSeal, Flow.sil, and Oxysafe gel in preventing microleakage in conical and straight internal abutment connections. They tested the implants in a suspension of Candida albicans and Staphylococcus aureus using the inward method and colony counting. They found that only GapSeal®was successful in significantly reducing microleakage, however their study was also conducted under static conditions.22

    Mostofi et al. (2019) studied the effect of GapSeal®on microleakage in internal hexagon connection implants,21 and Zarbakhsh et al. (2018) in external hexagon implants,31 with similar methodologies. They both tested microleakage under dynamic loading using the inward method with methylene blue dye, as well as measuring the microgap size using scanning electron microscopy. Both studies concluded that GapSeal® does not provide a complete seal but significantly decreases microleakage and number of gaps.21,23 However, studies that utilized bacteria to measure microleakage showed more consistent results with reality compared to methylene blue dyes.21 In addition, methylene blue dye leakage was reported qualitatively.21,23

    In the present study, GapSeal® was tested under dynamic loading to mimic the chewing action, and only two implants from the GS group showed no colony forming units (Table I). This means that GapSeal® did not provide a complete seal against microleakage. It did nonetheless significantly reduce microleakage through the IAI, which is in line with previous studies. One of the limitations of this study was not measuring the microgap size, so no correlation between the microgap size and microleakage could be deduced. Also, this study tested GapSeal® in a 24 hour period only, therefore additional studies for testing it in a longer time frame are needed since it is a silicone gel that breaks down with time. This will add clinical significance to the mentioned findings. The GapSeal manufacturer recommends the material be replaced every 5 years,24 so it is crucial to conduct in-vivo studies regarding its biological effects and longevity.

     

    CONCLUSION

    Considering the limitations found in the present study, the results showed that microbial leakage persistently occurred at the IAI in the internal hexagon implants after being exposed to dynamic loading, even with the application of GapSeal. However, the application of GapSeal was successful in significantly reducing the microleakage of S. sanguinis in-vitro through the IAI, under dynamic loading. Testing GapSeal's sealing longevity, in addition to whether the reduction in microleakage was due to GapSeal decreasing the size of the microgap or due to the antibacterial effect were not in the scope of this study and further research is required to investigate them.

     

    ACKNOWLEDGEMENT AND CONFLICT OF INTEREST

    The dental implants and their corresponding abutments were sponsored by MIS Implants Technologies Ltd. Authors declare no conflicts of interest related to this paper.

     

    REFERENCES

    1. Howe MS, Keys W, Richards D. Long-term (10-year) dental implant survival: A systematic review and sensitivity meta-analysis. Journal of dentistry. 2019 May 1;84:9-21.         [ Links ]

    2. Lopes de Chaves e Mello Dias EC, Sperandio M, Henrique Napimoga M. Association Between Implant-Abutment Microgap and Implant Circularity to Bacterial Leakage: An In Vitro Study Using Tapered Connection Implants. International Journal of Oral & Maxillofacial Implants. 2018 May 1;33(3).         [ Links ]

    3. McGlumphy EA, Mendel DA, Holloway JA. Implant screw mechanics. Dental Clinics of North America. 1998 Jan 1;42(1):71-89.         [ Links ]

    4. Jansen VK, Conrads G, Richter EJ. Microbial leakage and marginal fit of the implant-abutment interface. International Journal of Oral & Maxillofacial Implants. 1997 Jul 1;12(4).         [ Links ]

    5. Liu Y Wang J. Influences of microgap and micromotion of implant-abutment interface on marginal bone loss around implant neck. Archives of oral biology. 2017 Nov 1;83:153-60.         [ Links ]

    6. Koutouzis T, Mesia R, Calderon N, Wong F, Wallet S. The effect of dynamic loading on bacterial colonization of the dental implant fixture-abutment interface: an in vitro study Journal of oral implantology. 2014 Aug 1;40(4):432-7.         [ Links ]

    7. Tallarico M, Canullo L, Caneva M, Özcan M. Microbial colonization at the implant-abutment interface and its possible influence on periimplantitis: A systematic review and meta-analysis. Journal of Prosthodontic Research. 2017;61(3):233-41.         [ Links ]

    8. Mishra SK, Chowdhary R, Kumari S. Microleakage at the different implant abutment interface: a systematic review. Journal of clinical and diagnostic research: JCDR. 2017 Jun;11(6):ZE10.         [ Links ]

    9. Adell R, Lekholm U, Rockler BR, Bránemark PI. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. International journal of oral surgery. 1981 Jan 1;10(6):387-416.         [ Links ]

    10. Sahin C, Ayyildiz S. Correlation between microleakage and screw loosening at implant-abutment connection. The journal of advanced prosthodontics. 2014 Feb 1;6(1):35-8.         [ Links ]

    11. Bittencourt AB, Neto CL, Penitente PA, Pellizzer EP, Santos DM, Goiato MC. Comparison of the morse cone connection with the internal hexagon and external hexagon connections based on microleakage-review. Prague medical report. 2021 Oct 1;122(3):181-90.         [ Links ]

    12. Koutouzis T. Implant-abutment connection as contributing factor to peri-implant diseases. Periodontology 2000. 2019 Oct;81(1):152-66.         [ Links ]

    13. Lauritano D, Moreo G, Lucchese A, Viganoni C, Limongelli L, Carinci F. The impact of implant-abutment connection on clinical outcomes and microbial colonization: A narrative review. Materials. 2020 Mar 3;13(5):1131.         [ Links ]

    14. Scarano A, Perrotti V, Piattelli A, Iaculli F, Iezzi G. Sealing capability of implant-abutment junction under cyclic loading: A toluidine blue in vitro study. Journal of Applied Biomaterials & Functional Materials. 2015 Jul;13(3):293-5.         [ Links ]

    15. Al-Jadaa A, Attin T, Peltomäki T, Heumann C, Schmidlin PR. Impact of dynamic loading on the implant-abutment interface using a gas-enhanced permeation test in vitro. The open dentistry journal. 2015;9:112.         [ Links ]

    16. Mao Z, Beuer F, Wu D, Zhu Q, Yassine J, Schwitalla A, Schmidt F. Microleakage along the implant-abutment interface: a systematic review and meta-analysis of in vitro studies. International Journal of Implant Dentistry. 2023 Sep 21;9(1):34.         [ Links ]

    17. Canullo L, Penarrocha-Oltra D, Soldini C, Mazzocco F, Penarrocha M, Covani U. Microbiological assessment of the implant-abutment interface in different connections: cross-sectional study after 5 years of functional loading. Clinical oral implants research. 2015 Apr;26(4):426-34.         [ Links ]

    18. Koutouzis T, Gadalla H, Kettler Z, Elbarasi A, Nonhoff J. The role of chlorhexidine on endotoxin penetration to the implant-abutment interface (IAI). Clinical Implant Dentistry and Related Research. 2015 Jun;17(3):476-82.         [ Links ]

    19. Mohammadi F, Hajmousaei M, Vaziri N, Arshad M. Bacterial leakage at implant-abutment interface with different intermediate materials. Journal of Oral Implantology. 2019 Dec 27;45(6):451-5.         [ Links ]

    20. Nayak AG, Fernandes A, Kulkarni R, Ajantha GS, Lekha K, Nadiger R. Efficacy of antibacterial sealing gel and O-ring to prevent microleakage at the implant abutment interface: an in vitro study. Journal of Oral Implantology. 2014 Feb 1;40(1):11-4.         [ Links ]

    21. Nasser Mostofi S, Pahlevan R, Mohtasham Rad Z, Houshangi H, Keyhanlou F, Fazel S. Effectiveness of GapSeal on Microgap and Microleakage at Internal-Hexagon Implant Platform after Cyclic Loading. Res Dent Sci. 2019 Apr 10;16(1):34-41.         [ Links ]

    22. Smojver I, Bjelica R, Vuleti- M, Gerbl D, Budimir A, Gabri- D. Antimicrobial Efficacy and Permeability of Various Sealing Materials in Two Different Types of Implant-Abutment Connections. International journal of molecular sciences. 2022 Jul 21;23(14):8031.         [ Links ]

    23. Zarbakhsh A, Mazaheri Tehrani A, Shamshirgar F, Khosroshahi H. Effect of GapSeal® as a sealing material on microgap and microleakage at external hexagon implant connections following cyclic loading: an in vitro study. Journal of Research in Dental and Maxillofacial Sciences. 2018 Aug 10;3(3):42-8.         [ Links ]

    24. Fritzemeier CU. Periimplantitis prophylaxis by sealing internal implant spaces with GapSeal. Available at www.hagenA/erken.co.in. Accessed October. 2009;15.         [ Links ]

    25. Steinebrunner L, Wolfart S, Bößmann K, Kern M. In vitro evaluation of bacterial leakage along the implant-abutment interface of different implant systems. International Journal of Oral & Maxillofacial Implants. 2005 Nov 1;20(6).         [ Links ]

    26. Edgerton M, Lo SE, Scannapieco FA. Experimental salivary pellicles formed on titanium surfaces mediate adhesion of streptococci. International journal of oral and maxillofacial implants. 1996 Jul 1;11(4):443-9.         [ Links ]

    27. Bulleid A. A text-book of bacteriology for dental students. W. Heinemann; 1927.         [ Links ]

    28. Rimondini L, Marin C, Brunella F, Fini M. Internal contamination of a 2-component implant system after occlusal loading and provisionally luted reconstruction with or without a washer device. Journal of periodontology. 2001 Dec;72(12):1652-7.         [ Links ]

    29. Ranieri R, Ferreira A, Souza E, Arcoverde J, Dametto F, Gade-Neto C, Seabra F, Sarmento C. The bacterial sealing capacity of Morse Taper implant-abutment systems in vitro. Journal of periodontology. 2015 May;86(5):696-702.         [ Links ]

    30. Larrucea C, Conrado A, Olivares D, Padilla C, Barrera A, Lobos O. Bacterial microleakage at the abutment-implant interface, in vitro study. Clin Implant Dent Relat Res. 2018 Jun 1;20(3):360-7.         [ Links ]

    31. Ozdiler A, Bakir-Topcuoglu N, Kulekci G, Isik-Ozkol G. Effects of Taper Angle and Sealant Agents on Bacterial Leakage Along the Implant-Abutment Interface: An In Vitro Study Under Loaded Conditions. International Journal of Oral & Maxillofacial Implants. 2018 Sep 1;33(5).         [ Links ]

    32. Alves de Sousa C, Conforte JJ, Caiaffa KS, Duque C, Assunção WG. Sealing agent reduces formation of single and dual-species biofilms of Candida albicans and Enterococcus faecalis on screw joints at the abutment/implant interface. PloS one. 2019 Oct 22;14(10):e0223148.         [ Links ]

    33. Fernandes PF, Grenho L, Fernandes MH, Sampaio-Fernandes JC, Sousa Gomes P. Microgap and microleakage of a hybrid connection platform-switched implant system in the absence or presence of a silicone-based sealing agent. Odontology. 2022 Apr;110(2):231-9.         [ Links ]

    34. Khorshidi H, Raoofi S, Moattari A, Bagheri A, Kalantari MH. In vitro evaluation of bacterial leakage at implant-abutment connection: an 11-degree Morse taper compared to a butt joint connection. International journal of biomaterials. 2016;2016(1):8527849.         [ Links ]

    35. Paulo da Silva-Neto J, Antônio de Arruda Nóbilo M, Paulo Amante Penatti M, Simamoto Jr C, Domingues das Neves F. Influence of methodologic aspects on the results of implant-abutment interface microleakage tests: a critical review of in vitro studies. International Journal of Oral & Maxillofacial Implants. 2012 Aug 1;27(4).         [ Links ]

    36. do Nascimento C, Miani PK, Pedrazzi V, Muller K, de Albuquerque Junior RF. Bacterial leakage along the implant-abutment interface: culture and DNA checkerboard hybridization analyses. Clinical oral implants research. 2012 Oct;23(10):1168-72.         [ Links ]

    37. Yeo IS, Lee JH, Kang TJ, Kim SK, Heo SJ, Koak JY, Park JM, Lee SY. The effect of abutment screw length on screw loosening in dental implants with external abutment connections after thermocycling. International Journal of Oral & Maxillofacial Implants. 2014 Jan 1;29(1).         [ Links ]

    38. Proff P, Steinmetz I, Bayerlein T, Dietze S, Fanghänel J, Gedrange T. Bacterial colonisation of interior implant threads with and without sealing. Folia morphologica. 2006;65(1):75-7.         [ Links ]

    39. Castro Pimentel A, Manzi MR, Galileu Sartori S, da Graça Naclério-Homem M, Sendyk WR. In vivo effectiveness of silicone gel sheets as barriers at the inner microgap between a prosthetic abutment and an external-hexagon implant platform. International Journal of Oral & Maxillofacial Implants. 2014 Jan 1;29(1).         [ Links ]

    40. Ghannad F, Alkadi LT, Wiebe CB, Shen Y, Haapasalo M, Larjava HS. Intra-operative application of chlorhexidine gel reduces bacterial counts in internal implant cavity. European journal of oral sciences. 2015 Dec;123(6):425-31.         [ Links ]

    41. Yu P, Li Z, Tan X, Yu H. Effect of sealing gel on the microleakage resistance and mechanical behavior during dynamic loading of 3 implant systems. The Journal of Prosthetic Dentistry. 2022 Feb 1;127(2):308-17.         [ Links ]

     

     

    Correspondence:
    Name: Hadeel Badi
    Email: hadeelbadi9@gmail.com

     

     

    Authors contribution
    Hadeel Badi 60%
    Supervisor: Prof. Anthea Jeftha 30%
    Co-supervisor: Mr Ernest Maboza 10%