vol.50 número3Nutritional yield and nutritional water productivity of cowpea (Vigna unguiculata L. Walp) under varying irrigation water regimesInvestigating stable isotope effects and moisture trajectories for rainfall events in Johannesburg, South Africa índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

    Links relacionados

    • En proceso de indezaciónCitado por Google
    • En proceso de indezaciónSimilares en Google

    Compartir


    Water SA

    versión On-line ISSN 1816-7950versión impresa ISSN 0378-4738

    Resumen

    NAICKER, K; MAHLAMBI, PN; MAHLAMBI, MM  y  NOCANDA, X. Assessment of metals and anions in tap, river, wastewater, and sludge: comparison of hotplate- and microwave-assisted digestion. Water SA [online]. 2024, vol.50, n.3, pp.293-306. ISSN 1816-7950.  https://doi.org/10.17159/wsa/2024.v50.i3.4044.

    In this study, the analysis of metals in tap, river, wastewater, and sludge samples was conducted using ICP-OES after hotplate- or microwave-assisted digestion. Both digestion methods produced a good degree of accuracy, indicating their suitability for the analysis of the studied metals in water samples. From method development studies, 100 mL of HNO3 was found to be the optimum sample volume and acid type for digestion. The average concentrations obtained ranged from 4.9-410.8 μg/L, 5.9-465.0 μg/L, 3.6-425.4 μg/L, 16.1-647 μg/L and 9.7-784 μg/L in tap water, river, influent, effluent, and sludge samples, respectively. All metals were below their maximum permissible limits, with the exception of Mn in all sludge samples and Pb in all tap water, Umhlathuzana River, and Northern Works influent samples. Comparable recoveries and metal concentrations were obtained by microwave and hotplate methods, suggesting that the cheaper hotplate method can be used as an effective digestion method for daily analysis. Common anion concentrations obtained ranged from 0.03-23.5 mg/L, 0.02-3 064.67 mg/L, and 0.32-175.67 mg/L for tap, river, and wastewater samples, respectively. The anion concentrations were found to be below the maximum acceptable limits indicating no negative health effect on human and aquatic life, with the exception of Cl- and SO42- in Amanzimtoti and Northern River water, respectively.

    Palabras clave : water; heavy metals; anions; ICP-OES; microwave; hotplate.