Table of contents
Water SA, Volume: 50, Issue: 3, Published: 2024Water SA, Volume: 50, Issue: 3, Published: 2024
| Documents |
|---|
|
Research Papers Estimating the cost-effectiveness of several reservoir evaporation suppression strategies: a case study Chapman, RA Svendsen, D de Waal, J Abstract in English: Reservoirs often experience significant evaporation, causing a reduction in productive water use and prompting calls to curtail the loss. While efforts to reduce evaporation have predominantly focused on improving efficiencies, there has been a comparatively limited exploration of the associated costs per unit of additional water yield. To address this, a unit reference value (URV) calculation approach was employed in a case study to compare the unit costs of this additional yield through various evaporation suppression methods. The evaluated techniques included chemical monolayers, shade cloth, and both hard and soft floating covers. The URV calculation factored in capital, operating, and maintenance costs over a 20-year term, specified water-saving efficiencies for each technology, and various environmentally driven evaporation and social discount rates. The resulting URVs were compared with those for raising the Clanwilliam Dam, a large-scale groundwater scheme and the URVs for desalination. Notably, monolayers emerged with the lowest URV, but their yield efficiency is severely compromised by their short lifespan and high susceptibility to wind. The URVs of shade cloth proved competitive with those of desalination but are practical only for relatively small areas. In contrast, floating hard and soft covers demonstrated higher per-unit water delivery costs than desalination due to more frequent capital equipment replacements caused by their faster wear and weathering. The findings suggest that current evaporation suppression technologies may be economically unfeasible for agricultural and even domestic water supplies. The URV calculation serves as a valuable tool for comparing the cost-effectiveness of diverse yield-additive strategies. |
|
Research Papers Evaluating the potential for denitrification in permeable interlocking concrete pavements Brown, Luke P Armitage, Neil P Abstract in English: This research explored the denitrification potential of a submerged zone incorporated into the present permeable interlocking concrete pavement (PICP) design. The following three main factors controlling denitrification were investigated through a laboratory study: (i) detention time, (ii) inclusion of a carbon source (newspaper), and (iii) submerged zone depth. The study used 10 columns, each fully packed with 50-63 mm washed aggregate and including a 1.5 m deep submerged zone. Columns were paired according to detention time (1, 2, 5, 10 and 'varied' days) with one set including newspaper, the other set not. All columns were loaded with synthetic stormwater over a 4-month period. Samples were taken from different submerged depths (0, 300, 600, 900, 1200 and 1 500 mm) and analysed for concentrations of ammonia (NH3), nitrate (NO3-) and phosphate (PO43-) every 10 days. This study found that 10 - or more - days detention and the provision of a carbon source had the most significant impact on denitrification - providing an overall mean NO3- and nitrogen removal above 41% and 59%, respectively. Moreover, a submerged depth of 300 mm was sufficient to achieve a minimum NO3- removal of 41% in columns which included a carbon source and had 10 days detention. Generally, an increase in detention time resulted in an increase in NH3 and PO43- removal with overall mean values of 86% and 30%, respectively, achieved with 10-day detention periods. |
|
Research Papers Biomass response of chickpea (Cicer arietinum L.) to different textured soils and irrigation levels Masowa, Manare Maxson Dlamini, Phesheya Khetsha, Zenzile Peter Abstract in English: Irrigation is required to supplement rainfall to enhance the productivity of chickpea in South Africa (SA). However, the dependence on irrigation can be problematic for SA and other countries with limited natural water resources and variable rainfall. Even though access to irrigation water has been identified as one of the challenges faced when planting chickpea in the winter season in SA, irrigation management strategies for chickpea grown on soils differing in texture have not gained considerable research attention. Hence, this study aimed to assess the effects of irrigation levels on dry matter production of chickpea grown on two soils differing in soil texture under greenhouse conditions. The experiment was arranged as a 3 × 2 factorial in a completely randomized design, with 3 irrigation levels (25%, 50% and 75% of the water-holding capacity of soil (WHC)) and 2 soils differing in soil textural class (Loamy sand (LS) soil and sandy loam (SL) soil), replicated thrice. Irrigation level, soil texture and their interaction significantly affected shoot biomass (SBM) and total plant biomass (TBM). Generally, SBM, TBM and root biomass decreased correspondingly with the reduction in irrigation. The 25% WHC significantly reduced the SBM by up to 60% and TBM by up to 56% compared to the 50% and 75% WHC. The SBM and TBM were higher in SL soil than in LS soil. A significantly higher root/shoot ratio (0.45) in the LS soil than in the SL soil (0.16) indicated that the conditions of LS soil encouraged plants to allocate higher proportions of biomass into roots, possibly due to increased competition for soil resources. In conclusion, maintaining soil moisture at 50% WHC ensures better chickpea dry matter production in SL soil. |
|
Research Papers Comparative life cycle assessment (LCA) of pre-treatment technologies for desalination in South Africa Draper, W Goga, T Friedrich, E Abstract in English: In the context of South Africa's water scarcity, desalination has emerged as a possible solution for coastal areas. However, the quality of the intake water for desalination is often problematic, prompting the need for pre-treatment. The aim of this study was to conduct a comparative environmental life cycle assessment (LCA) on 4 seawater filtration systems intended for the pre-treatment of a reverse osmosis desalination project. These systems were implemented in a pilot trial and are based on modern water treatment technologies, namely, granular filtration (pressure driven and gravity driven), dissolved air flotation (DAF), and ultrafiltration (UF). For all 4 systems, data were collected for both the construction and operation phases, and LCAs were performed, resulting in environmental scores that allow for comparison based on the pre-treatment of 1 kL of seawater of the same quality. The SimaPro LCA tool and the ReCiPe midpoint method were used and environmental scores were calculated for 18 impact categories, including climate change, acidification, toxicity, eutrophication, resource depletion, etc. This methodology also allowed the identification of the highest environmental burdens/scores within each system. The most significant finding is that local electricity consumption is responsible for the greatest proportion of environmental impacts. Thus, the systems consuming more energy for operating equipment such as blowers, pumps, and mixers were found to have the highest environmental burdens. Hence, the DAF system has the highest environmental scores for most impacts, followed by the single-phase gravity filtration system, then the two-phase partial pressure filtration system and finally the UF system. Therefore, focus should shift towards energy optimisation of process units, especially the rotary ones, as well as energy mitigation and recovery strategies. The use of renewable energy for pre-treatment should also be considered locally. |
|
Research Papers Balancing pH for enhanced bacterial community performance in microbial fuel cells: implications for bio-electricity generation and pollutant reduction Khanaum, Mosammat Mustari Rahman, Shafiqur Borhan, Md. Saidul Bergholz, Peter Abstract in English: Microbial fuel cells (MFCs) represent a promising technology to generate bio-electricity and synchronously reduce wastewater pollutants. The presence of exoelectrogens in wastewater is critical for bio-electricity and pollutant reduction, but the performance of exoelectrogens at different pH levels remains unknown. This study aims to bridge this gap by offering an integrated approach to understanding the performance of exoelectrogens under varying substrate pH, particularly in bio-electricity generation and pollutant reduction in sugarbeet processing wastewater (SBWW). Three pH levels (ranging from acidic to alkaline) were studied and MFC's electricity output was measured. Later, current density, power density, and coulombic efficiency (CE) were calculated. Both pre- and post-experiment substrate samples were analysed with inductively coupled plasma (ICP). Furthermore, 16S rRNA gene analysis, DNA amplification, sequencing library preparation, and bioinformatics workflows on post-experiment samples of the substrate and anode samples were conducted. A diverse community of microorganisms was identified, especially Alphaproteobacteria, Gammaproteobacteria, and Deltaproteobacteria (Geobacter). Bacteroidetes and Desulfovibrio were the major exoelectrogens responsible for electricity generation. Among the three pH levels tested, the most alkaline pH level (9.5±0.1) outperformed the others, achieving a 54% higher power density, 21% greater current density, and a 40% higher CE compared to the acidic pH level (6.5±0.1). Around 50-99% of pollutants were removed from the SBWW. The study revealed that Gammaproteobacteria thrive and perform better in alkaline environment. |
|
Research Papers Assessment of metals and anions in tap, river, wastewater, and sludge: comparison of hotplate- and microwave-assisted digestion Naicker, K Mahlambi, PN Mahlambi, MM Nocanda, X Abstract in English: In this study, the analysis of metals in tap, river, wastewater, and sludge samples was conducted using ICP-OES after hotplate- or microwave-assisted digestion. Both digestion methods produced a good degree of accuracy, indicating their suitability for the analysis of the studied metals in water samples. From method development studies, 100 mL of HNO3 was found to be the optimum sample volume and acid type for digestion. The average concentrations obtained ranged from 4.9-410.8 μg/L, 5.9-465.0 μg/L, 3.6-425.4 μg/L, 16.1-647 μg/L and 9.7-784 μg/L in tap water, river, influent, effluent, and sludge samples, respectively. All metals were below their maximum permissible limits, with the exception of Mn in all sludge samples and Pb in all tap water, Umhlathuzana River, and Northern Works influent samples. Comparable recoveries and metal concentrations were obtained by microwave and hotplate methods, suggesting that the cheaper hotplate method can be used as an effective digestion method for daily analysis. Common anion concentrations obtained ranged from 0.03-23.5 mg/L, 0.02-3 064.67 mg/L, and 0.32-175.67 mg/L for tap, river, and wastewater samples, respectively. The anion concentrations were found to be below the maximum acceptable limits indicating no negative health effect on human and aquatic life, with the exception of Cl- and SO42- in Amanzimtoti and Northern River water, respectively. |
|
Research Papers Groot Aub groundwater quality and its suitability for domestic purposes, Namibia Mutilifa, Liina Kedir, Bushira Mapani, Benjamin Shikangalah, Rosemary Abstract in English: The Groot Aub (GA) settlement depends entirely on groundwater for domestic purposes and other development activities. Development activities are mainly agriculture, such as animal husbandry, chicken farming and crop farming using irrigation. However, these activities have the potential to contaminate the groundwater system. A total of 87 groundwater samples were collected from the boreholes in the study area during the dry and wet season. Water quality parameters (pH, salinity, total dissolved solids (TDS), electrical conductivity (EC) and hydrochemistry (Na+ > Ca2+ > Mg2+ > K+, and HCO3- > SO42- > Cl-) of 5 boreholes and 1 reservoir tank were analysed. The dominant cations were attributed to cation exchange processes as a coupled exchange of Na+ + K+ replacing Ca2+; and Na+ replacing Mg2+ ions in the rock-water interactions. The HCO3- anion is attributed to underlying rich carbonate rocks in the study area and chemical reactions between groundwater and silicate minerals. TDS ranged from 639.01 to 1 998.96 mg/L. The microbial levels as indicated by heterotrophic plate count (HPC) values exceed the limits imposed by the local Namibian and WHO drinking water regulations. The Piper diagrams showed a mixed water type of mainly HCO3- and SO42-anions and Na+ and Ca2+ > Mg2+ cations. The study shows that the elemental composition of the groundwater is impacted significantly by primarily anthropogenic activities and secondarily geogenic processes. Based on the results of this study it is recommended that a buffer zone be created between human activities and production boreholes to avoid further groundwater contamination. |
Read our Open Access Statement
