Open-access A retrospective comparison of the diagnostic accuracy of CT-guided percutaneous core needle and open biopsy for musculoskeletal tumours

Abstract

BACKGROUND: An accurate histological diagnosis is imperative for directed management of musculoskeletal tumours. Globally there has been a shift from open biopsies to less invasive computerised tomography (CT)-guided percutaneous core needle biopsies for diagnosis. Literature suggests comparable diagnostic accuracy with the two modalities. This investigation aimed to evaluate the diagnostic accuracy of CT-guided percutaneous core needle biopsy (CTNB) compared to open biopsy (OB) in musculoskeletal tumours at a South African training hospital. METHODS: A retrospective review of patients' histological records was conducted for patients who underwent either CTNB or OB for a primary musculoskeletal tumour, followed by definitive surgical resection. Patients of any age who had a biopsy between January 2017 and December 2021, whose biopsy was not excisional nor performed during a definitive procedure for a pathological or impending fracture, were eligible for inclusion. Biopsies of metastatic lesions were excluded. Biopsy results were compared to final histopathological diagnoses to determine diagnostic accuracy. Sensitivity, specificity and predictive values were calculated. Logistic regression was conducted to determine if significant differences in accuracy were present between the biopsy techniques. RESULTS: Forty-eight patients met inclusion criteria, of which 33 had a CTNB (69%) and 15 an OB (31%). Patients had a median age of 26 years, and 54% were female. There were 33 malignant lesions (69%) and 15 benign lesions (31%). Most were primary bone lesions (27, 56%) of the lower limb (40, 83%). Diagnostic accuracy was 73% for CTNB and 87% for OB. Statistical significance could not be determined due to the limited sample size. The ability to distinguish between benign and malignant lesions was 91% for CTNB and 100% for OB. The sensitivity and specificity for detecting malignancy utilising CTNB were 92% and 89%, respectively, whereas for OB, both sensitivity and specificity were 100%. CONCLUSION: CTNB and OB in this setting have acceptable sensitivity and specificity profiles for distinguishing benign from malignant lesions. Although this study could not confirm equivalence due to limited power, the results suggest CTNB is a viable alternative to incisional biopsy. Larger local prospective studies are needed to determine if both biopsy types are equivalent for future diagnostic practices. Level of evidence: 4

biopsy; musculoskeletal tumour; CT-guided percutaneous core needle biopsy; open biopsy; histopathological diagnostic accuracy


Introduction

An accurate histological diagnosis is imperative for directed management of musculoskeletal tumours.111122,3 Performing open biopsies in an operating theatre burdens the established South African theatre access limitations.435-7 Percutaneous core needle biopsy has gained popularity due to several advantages over the OB technique.8 5,8-11 Complication rates as low as 1% have been reported.71212

Internationally, results of investigation of the diagnostic accuracy of OB as compared to CT-guided percutaneous core needle biopsy (CTNB) in bone and soft tissue sarcomas have been mixed.6,13 A 2018 meta-analysis of Ave studies directly comparing CTNB and OB found that OB was 6.1 times more likely to yield an accurate result.6661314,15

Limited investigation has been conducted in the South African context to assess the accuracy of CTNB,161718

Methods

Patients

This retrospective comparative study investigated the CTNB and OB histological result accuracy for consecutive patients with bone and soft tissue tumours (that required biopsy for diagnostic purposes) who presented to the orthopaedic oncology unit at a training hospital in South Africa between January 2017 and December 2021. The report was compiled following the Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) guidelines.19

Patients of all ages who underwent either a CTNB or an OB (between 1 January 2017 and 31 December 2021) and had a subsequent definitive tumour resection histopathological diagnosis for a primary bone or soft tissue tumour were eligible for inclusion. This meant that biopsies performed at the time of definitive surgery (nail insertion or arthroplasty) for pathological fracture or impending fracture were not eligible for inclusion. Also ineligible were cases where the diagnosis was evident based on history, clinical examination and imaging, that had a biopsy as part of the definitive surgery, or an excisional biopsy to complete the management. Patient selection for CTNB or OB was case-based, dependent on radiologist availability, accessibility of lesion (intramedullary lesions and lesions deeper than 14-16 cm are not easily accessible with 14G coaxial needle), and patient preference. Theatre records and the procedural CT register were used to identify all biopsy cases within the inclusion period. Basic demographic details, including name, age, sex, date of birth, hospital number, biopsy site and date of biopsy were captured. The patients' histopathological records were traced using the sourced names, dates of birth, and hospital numbers. The demographic and histopathological details were captured on a Microsoft® Excel (version 16.94) spreadsheet to summarise and prepare for statistical analysis. Biopsies of all metastatic lesions were excluded.

Biopsy techniques

CTNBs were performed by an experienced consultant radiologist. They were performed following gadolinium-enhanced magnetic resonance imaging (MRI). MRI was used to delineate the peritumoral reactive zone and to identify a location for sourcing a representative sample, avoiding areas of necrosis (Figure 1a).20 21 Figure 1b). Typically, five samples were sent for histological analysis, one or two samples for tuberculosis (TB) polymerase chain reaction (PCR), and another one or two for microscopy, culture, and sensitivity (MC&S). The biopsy site was marked with a non-absorbable single skin suture to facilitate future biopsy-site excision at the time of definitive surgery. CT images with the biopsy needle in situ were saved on the picture-archiving system for future reference.

Open biopsies were similarly performed after MRI imaging was completed. Analysis of the MRI study formed part of the preoperative planning conducted by the operating orthopaedic oncology surgeon. Biopsy sites were selected after considering imaging and planning future tumour resection surgery. Open biopsies were conducted in an operating theatre under general or regional anaesthesia (dependent on tumour location). OB surgical principles outlined by Abeysekera & Punchihewa were followed during each procedure.22

Definitions and analysis

Following the methods of the systematic review and meta-analysis of Birgin et al., accuracy was determined with reference to the final surgical resection histopathological diagnosis.1313,23,24 For results where the biopsy histology was concordant with the resection histology regarding the nature of the lesion (benign or malignant), we preferentially used the term 'effectively accurate' (other previously utilised terms include: 'dignity of lesion' and 'accurate').13,23,25 Cases that did not fulfil either of these criteria were termed inaccurate. In practice, in cases where the biopsy result (CTNB or OB) was discordant with the patient's presentation, examination and imaging findings, a repeat biopsy (always OB) was performed; the results of these OBs were not included in this investigation.

Statistical analysis comprised descriptive and analytical components. The Microsoft® Excel (version 16.94) spreadsheet data was exported to jamovi (version 2.6.44.0) for analysis. Categorical variables were summarised with counts and percentages, and continuous variables (age) summarised with median, interquartile range (IQR) and range. A sensitivity analysis was conducted utilising the 'effective accuracy' to determine sensitivity, specificity, positive, and negative predictive values of CTNB and OB with reference to the nature of the final histological specimen as malignant (test positive) or benign (test negative). Both accuracy and effective accuracy were calculated for CTNB and OB. The area under the curve (AUC) was reported using effective accuracy results for CTNB and OB. Binomial logistic regression was conducted to assess for significant differences in demographic variables and effective accuracy between CTNB and OB for various variables (location of lesion, bony or soft tissue lesion and final histological finding of malignant or benign lesion). Where appropriate, these results are reported as odds ratios (OR) with 95% confidence intervals. Statistical significance was accepted for p values of < 0.05.

Results

A total of 48 patients were included in the study. Figure 2 depicts the case enrolment, detailing cases not meeting inclusion criteria (n = 77) and exclusions (n = 5). The study population consisted of 26 (54%) female and 22 (46%) male patients, with a median age of 26 years (IQR 31, range of 8-75). Thirty-three malignant lesions (69%) and 15 benign lesions (31%) were identified. Most were primary bone lesions (27, 56%) in the lower limb (40, 83%). Thirty-three (69%) biopsies were performed as CTNBs and 15 (31%) as OBs. For variables that were sufficiently powered, there were no significant demographic, biopsy location or biopsy tissue type differences between the biopsy modalities. Table I compares the patient and tumour characteristics in the CTNB and OB groups.

In comparison of the two biopsy modalities, the accuracy for CTNB was 73% and for OB 87%. The samples were inadequately powered to determine if this difference was significant. The effective accuracy, or ability to distinguish between benign and malignant lesions, was 91% for CTNB and 100% for OB. The sensitivity and specificity for detecting malignancy utilising CTNB were 92% and 89%, respectively, whereas for OB, both sensitivity and specificity were 100%. In CTNB cases, a result positive for malignancy was correct in 96% of cases, and a negative result was correct in 80% of cases. For OB, both positive and negative results were correct for the detection of or absence of malignancy in 100% of cases (Table II). The sample was underpowered to detect a difference in effective accuracy of CTNB and OB for tumour location, origin of tumour (bony or soft tissue), or nature of tumour (benign or malignant). CTNB and OB showed good discrimination, with AUC values of 0.878 and 1.000, respectively.

In the CTNB group, three of the biopsy (3 of 33, 9%) samples were inaccurate. Two of the three inaccurate results in the CTNB group were false negatives, samples initially assessed as benign lesions but later confirmed to be malignant. This was evident by the negative predictive value (80%), the CTNB group's lowest-scoring sensitivity parameter. The final inaccurate sample was initially assessed as malignant, but the final histological specimen confirmed a benign lesion (a false positive). Table III provides the specific histological findings of the inaccurate results.

Upon final histological analyses, 27 of the 48 lesions biopsied were of bony origin, most of which were malignant (18 of 27, 67%). Osteosarcoma was the most prevalent diagnosis of all histological diagnoses (17 of 48, 35%), followed by chondrosarcoma, both skeletal and extraskeletal variants (4 of 48, 8%). Giant cell tumour of bone was the most common benign bony lesion identified (3 of 48, 6%), and lipoma was the most common benign soft tissue lesion (3 of 48, 6%). Table IV summarises the final histological results comparing CTNB and OB samples.

Discussion

This investigation aimed to compare the diagnostic accuracy of CTNB and OB for musculoskeletal tumours at an oncology unit at a South African training hospital. While the sample was underpowered to detect significant differences in the accuracy rates, the sensitivity analyses determined good discrimination for both modalities to identify malignancy successfully. Similar findings have been documented in international investigations comparing percutaneous and open biopsies,1,3,6,13,24 which is the likely driver for the global increase in popularity of percutaneous biopsy methods.2632612,20 This is particularly pertinent when the lesions are small, deep-seated, have large areas of necrosis or are located in difficult to access areas like the pelvis, spine, sacrum or scapula.7,12,15,20 Literature has shown diagnostic accuracy rates of CTNB to be favourable, ranging from 80 to 100%.6,7,11,25,27 These accuracy rates evaluated critically, however, represent a mix of both accurate and effectively accurate results as defined in this investigation. So, while the accuracy of CTNBs undertaken at our institution (73%) at first appears to be on the lower end of the accuracy range, it is, in fact, similar, if effective accuracy is considered (91%). However, these findings are not necessarily generalisable to other contexts. The study was conducted in an experienced centre with a radiologist proficient in taking CTNBs and musculoskeletal oncology surgeons. Pohlig et al. suggested that the surgeon's experience and training in performing the biopsy affected their investigation's overall diagnostic yield and accuracy.1 116

Nevertheless, inaccurate results offer the opportunity to refine the biopsy technique and evaluate opportunities for improvement. A close review of the histological analyses shows that CTNB was effectively accurate for a broad spectrum of bony and soft tissue lesions. A substantial number of these were malignant cases, including 14 osteosarcomas. This is interesting in light of Taupin et al's. finding that CTNB inaccuracy is more likely with bone tumours than soft tissue tumours.18282930

The retrospective nature of the study, reliant on incomplete patient records, resulted in a small number of included cases. This limited the determination of significant differences in accuracy between the modalities. Furthermore, patient selection for CTNB or OB was based on the availability of the radiologist, patient preference and lesion location, all of which have the potential to introduce a selection bias. A larger randomised and prospective investigation would be better suited to compare the accuracy of the two modalities. However, for the purpose of assessing the accuracy of the individual modalities, both modalities show acceptable sensitivity profiles for use in practice.

Conclusion

CTNB and OB in this setting have acceptable sensitivity and specificity profiles for distinguishing benign from malignant lesions. While this study was underpowered to confirm equivalence, the findings support that CTNB is a viable alternative to incisional biopsy. Larger, local, prospective studies are needed to determine equivalence of the two biopsy modalities to guide future local diagnostic practices.

Acknowledgements

The authors of this study would like to acknowledge Dr Miranda du Rand of the Department of Radiology, Greys Hospital, for her valuable contribution to the study.

Ethics statement

The author/s declare that this submission is in accordance with the principles laid down by the Responsible Research Publication Position Statements as developed at the 2nd World Conference on Research Integrity in Singapore, 2010. The study complied with the South African Department of Health ethics guidelines (2015), and the University of KwaZulu-Natal policy on research ethics. Prior to commencement of this research the appropriate ethical approval was obtained from the Biomedical Research Ethics Committee of UKZN (BREC/00006829/2024). All procedures were in accordance with the ethical standards of the responsible committee on human experimentation (institutional and national) and with the Helsinki Declaration of 1975, as revised in 2008. Informed written consent was not obtained from patients included in the study as the work represents a retrospective review of patient charts.

Declaration

The authors declare authorship of this article and that they have followed sound scientific research practice. This research is original and does not transgress plagiarism policies.

Author contributions

ZJCS: conceptualisation; investigation; data curation; writing of original draft, review and editing; visualisation

LN: conceptualisation; investigation (data collection); writing of review and editing; supervision

MOC: methodology; formal analysis; writing of review and editing; supervision

LCM: conceptualisation; writing of review and editing

ORCID

Slchone ZJC https://orcld.org/0009-0005-4000-9573

Nieuwoudt L https://orcld.org/0000-0002-1309-2210

O'Connor M https://orcld.org/0000-0001-8864-4916

Marals LC https://orcld.org/0000-0002-1120-8419

References

  • 1. Pohlig F, Kirchhoff C, Lenze U, et al. Percutaneous core needle biopsy versus open biopsy In diagnostics of bone and soft tissue sarcoma: a retrospective study. Eur J Med Res. 2012;17:29. 20121101. https://doi.org/10.1186/2047-783x-17-29
    » https://doi.org/10.1186/2047-783x-17-29
  • 2. Sabharwal T, Salter R, Adam A, et al. Image-guided therapies in orthopedic oncology. Orthop Clin North Am. 2006;37:105-12. https://doi.org/10.1016/j.ocl.2005.08.001
    » https://doi.org/10.1016/j.ocl.2005.08.001
  • 3. Alam Q, Ullah N, Salman M, et al. Open vs percutaneous core needle biopsy (CNB) for musculoskeletal malignancies. J Popul Ther Clin Pharmacol. 2024;33:893-901. https://doi.org/10.53555/jptcp.v31i1.4096
    » https://doi.org/10.53555/jptcp.v31i1.4096
  • 4. Dell AJ, Kahn D. Surgical resources in South Africa: a review of the number of functional operating theatres. S Afr J Surg. 2018; 56: 2-8.
  • 5. Errani C, Traina F, Perna F, et al. Current concepts in the biopsy of musculoskeletal tumors. Sci World J. 2013;2013:538152. 20130605. https://doi.org/10.1155/2013/538152
    » https://doi.org/10.1155/2013/538152
  • 6. Kubo T, Furuta T, Johan MP, et al. A meta-analysis supports core needle biopsy by radiologists for better histological diagnosis in soft tissue and bone sarcomas. Medicine (Baltimore). 2018;97:e11567. https://doi.org/10.1097/md.0000000000011567
    » https://doi.org/10.1097/md.0000000000011567
  • 7. Dupuy DE, Rosenberg AE, Punyaratabandhu T, et al. Accuracy of CT-guided needle biopsy of musculoskeletal neoplasms. AJR Am J Roentgenol. 1998;171:759-62. https://doi.org/10.2214/ajr.171.3.ajronline_171_3_001
    » https://doi.org/10.2214/ajr.171.3.ajronline_171_3_001
  • 8. Kiefer J, Mutschler M, Kurz P, et al. Accuracy of core needle biopsy for histologic diagnosis of soft tissue sarcoma. Sci Rep. 2022;12:1886. https://doi.org/10.1038/s41598-022-05752-4
    » https://doi.org/10.1038/s41598-022-05752-4
  • 9. Mankin HJ, Lange TA, Spanier SS. The hazards of biopsy in patients with malignant primary bone and soft-tissue tumors. J Bone Joint Surg Am. 1982;64:1121-27. 1982/10/01.
  • 10. Mankin HJ, Mankin CJ, Simon MA. The hazards of the biopsy, revisited. Members of the Musculoskeletal Tumor Society. J Bone Joint Surg Am. 1996;78:656-63. https://doi.org/10.2106/00004623-199605000-00004
    » https://doi.org/10.2106/00004623-199605000-00004
  • 11. Issakov J, Flusser G, Kollender Y, et al. Computed tomography-guided core needle biopsy for bone and soft tissue tumors. Isr Med Assoc J. 2003;5:28-30.
  • 12. Puri A, Shingade VU, Agarwal MG, et al. CT-guided percutaneous core needle biopsy in deep seated musculoskeletal lesions: a prospective study of 128 cases. Skeletal Radiol. 2006;35:138-43. https://doi.org/10.1007/s00256-005-0038-4
    » https://doi.org/10.1007/s00256-005-0038-4
  • 13. Birgin E, Yang C, Hetjens S, et al. Core needle biopsy versus incisional biopsy for differentiation of soft-tissue sarcomas: A systematic review and meta-analysis. Cancer. 2020;126:1917-28. https://doi.org/10.1002/cncr.32735
    » https://doi.org/10.1002/cncr.32735
  • 14. Adams SC, Potter BK, Pitcher DJ, et al. Office-based core needle biopsy of bone and soft tissue malignancies: an accurate alternative to open biopsy with infrequent complications. Clin Orthop Relat Res. 2010;468:2774-80. 20100626. https://doi.org/10.1007/s11999-010-1422-5
    » https://doi.org/10.1007/s11999-010-1422-5
  • 15. Ray-Coquard I, Ranchere-Vince D, Thiesse P, et al. Evaluation of core needle biopsy as a substitute to open biopsy in the diagnosis of soft-tissue masses. Eur J Cancer. 2003;39:2021-2025. https://doi.org/10.1016/s0959-8049(03)00430-1
    » https://doi.org/10.1016/s0959-8049(03)00430-1
  • 16. Chuene MA. Yield of percutaneous core needle biopsies in musculoskeletal tumours. University of Witwatersrand, Faculty of Health Sciences, 2022.
  • 17. Pillay Y, Ferreira N, Marais LC. Primary malignant bone tumours: Epidemiological data from an orthopaedic oncology unit in South Africa. SA Orthop J. 2016;15(4).
  • 18. Taupin T, Decouvelaere AV, Vaz G, et al. Accuracy of core needle biopsy for the diagnosis of osteosarcoma: A retrospective analysis of 73 patients. Diagn Interv Imaging. 2016;97:327-31. https://doi.org/10.1016/j.diii.2015.09.013
    » https://doi.org/10.1016/j.diii.2015.09.013
  • 19. von Elm E, Altman DG, Egger M, et al. The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statement: guidelines for reporting observational studies. J Clin Epidemiol. 2008;61:344-49. https://doi.org/10.1016/j.jclinepi.2007.11.008
    » https://doi.org/10.1016/j.jclinepi.2007.11.008
  • 20. Putta T, Gibikote S, Madhuri V, et al. Accuracy of Various MRI sequences in determining the tumour margin in musculoskeletal tumours. Pol J Radiol. 2016;81:540-48. 20161116. https://doi.org/10.12659/pjr.898108
    » https://doi.org/10.12659/pjr.898108
  • 21. Spinnato P, Colangeli M, Rinaldi R, et al. Percutaneous CT-guided bone biopsies: indications, feasibility and diagnostic yield in the different skeletal sites-from the skull to the toe. Diagnostics (Basel). 2023;13 20230712. https://doi.org/10.3390/diagnostics13142350
    » https://doi.org/10.3390/diagnostics13142350
  • 22. Abeysekera WYM, Punchihewa GL. Biopsy principles of musculoskeletal tumours - when, where, who and how? Sri Lanka J Surg. 2015;33(2). .https://doi.org/10.4038/sljs.v33i2.8147
    » https://doi.org/10.4038/sljs.v33i2.8147
  • 23. Omura MC, Motamedi K, UyBico S, et al. Revisiting CT-guided percutaneous core needle biopsy of musculoskeletal lesions: contributors to biopsy success. AJR Am J Roentgenol 2011; 197: 457-461. https://doi.org/10.2214/ajr.10.6145
    » https://doi.org/10.2214/ajr.10.6145
  • 24. Kasraeian S, Allison DC, Ahlmann ER, et al. A comparison of fine-needle aspiration, core biopsy, and surgical biopsy in the diagnosis of extremity soft tissue masses. Clin Orthop Relat Res. 2010;468:2992-3002. https://doi.org/10.1007/s11999-010-1401-x
    » https://doi.org/10.1007/s11999-010-1401-x
  • 25. Altuntas AO, Slavin J, Smith PJ, et al. Accuracy of computed tomography guided core needle biopsy of musculoskeletal tumours. ANZ J Surg. 2005;75:187-91. https://doi.org/10.1111/j.1445-2197.2005.03332.x
    » https://doi.org/10.1111/j.1445-2197.2005.03332.x
  • 26. Burke ZDC, Lazarides AL, Gundavda MK, et al. Open versus core needle biopsy in lower-extremity sarcoma: current practice patterns and patient outcomes. J Bone Joint Surg Am. 2023;105:57-64. 20230719. https://doi.org/10.2106/JBJS.22.01259
    » https://doi.org/10.2106/JBJS.22.01259
  • 27. Kiatisevi P, Thanakit V, Sukunthanak B, et al. Computed tomography-guided core needle biopsy versus incisional biopsy in diagnosing musculoskeletal lesions. J Orthop Surg (Hong Kong). 2013;21:204-208. https://doi.org/10.1177/230949901302100218
    » https://doi.org/10.1177/230949901302100218
  • 28. Gonzalez AL, Cates JMM. Osteosarcoma: differential diagnostic considerations. Surg Pathol Clin. 2012;5:117-46. https://doi.org/10.1016/j.path.2011.07.011
    » https://doi.org/10.1016/j.path.2011.07.011
  • 29. Arthi M, Joseph LD, Kumar Ka. Clinicopathological profile of nodular hidradenoma: a ten year study in a tertiary care center. J Cutan Aesthet Surg. 16(1):34-37. https://doi.org/10.4103/JCAS.JCAS_125_21
    » https://doi.org/10.4103/JCAS.JCAS_125_21
  • 30. Klein A, Fell T, Birkenmaier C, et al. Relative sensitivity of core-needle biopsy and incisional biopsy in the diagnosis of musculoskeletal sarcomas. Cancers (Basel). 2021;13 20210319. https://doi.org/10.3390/cancers13061393
    » https://doi.org/10.3390/cancers13061393

Received: July 2025
Accepted: October 2025
Published: August 2026

* Corresponding author:
Editor: Prof. Theo le Roux, University of Pretoria, Pretoria, South Africa
Funding: No funding was received for this study.
Conflict of interest: The authors declare they have no conflicts of interest that are directly or indirectly related to the research.

Correspondence

zjc.sichone@gmail.com

Publication Dates

  • Publication in this collection
    21 Sept 2026
  • Date of issue

History

  • Received
  • Accepted
location_on
Medpharm Publications South African Orthopaedic Association (SAOA), P.O. Box 12918, Brandhof, Bloemfontein, Free State, ZA, 9324, Tel: +27 51 430 3280 - E-mail: pat@saoj.co.za
rss_feed Stay informed of issues for this journal through your RSS reader
Go to top