Open-access Patient-perceived barriers and facilitators to full weight-bearing with a lower-extremity circular external fixator: a qualitative study

Abstract

BACKGROUND: Circular external fixators are commonly used in orthopaedics to immobilise fractured bones and correct deformities. Early weight-bearing with circular external fixators has been shown to enhance bone growth and improve patient outcomes. However, many patients do not fully weight-bear after surgery, indicating the presence of barriers to early weight-bearing that need to be addressed. The objective was to identify the barriers and facilitators to full weight-bearing with a circular external fixator. METHOD: Patients with lower-limb circular external fixators in Pretoria, South Africa, were invited to participate in a qualitative exploratory study, using semi-structured interviews. The interviews were audio-recorded, transcribed verbatim, and analysed using thematic content analysis. Data saturation was reached after nine interviews. RESULTS: Four themes were obtained. These included pain/pain management, participants' state of mind, physical factors, and medical/non-medical support systems. The interviews revealed that pain, swelling, and the history of the injury influenced the participants' ability to bear weight, and their state of mind. Physical factors related to the human body and external fixator equipment also played a role, as did the availability of medical and non-medical support systems. Complications and fear of refracturing or falling were additional factors affecting mobilisation and weight-bearing. CONCLUSION: The findings of this study emphasise the importance of addressing physical and psychological factors affecting rehabilitation. While identifying the barriers and facilitators is beneficial, the study's limitations may reduce the generalisability of the findings. Further research on the implementation of solutions to address these factors in physiotherapy practice are warranted in this context. Level of evidence: 3

external fixator; weight-bearing; bone growth; rehabilitation; physical therapy; Ilizarov


Introduction

This study aimed to address a critical gap in understanding the barriers and facilitators to full weight-bearing with lower-limb circular external fixators. Due to the dearth of available evidence on external fixator rehabilitation, this information may improve patient outcomes and treatment strategies. The research question was: What are the barriers and facilitators to full weight-bearing with a lower-limb circular external fixator?

Circular external fixators, pioneered by Ilizarov in the 1950s, consist of metal rings held in place with pins running through soft tissue and bone. These devices offer rigidity for healing without opening the fracture site.12-4 Hexapod-style fixators represent the latest iteration of circular fixators. They are designed to optimise mechanical performance in promoting callus formation under both low and high axial loads, although higher loads are preferred. Unfortunately, the orientation of the loading plane and the placement of half pins significantly influence the bending stiffness of unilateral fixators. When unilateral frames are loaded out of plane, torsional and varus-valgus forces can cause noticeable movement at the fracture site, compromising the stability of bony fragments.55

External fixators have become essential in orthopaedic practice, treating comminuted fractures, non-union of bones, deformities, and leg length discrepancies. They also aid in ankle arthrodesis, infection control, osteomyelitis, and cosmetic limb lengthening, serving as an alternative to amputation.1,6-10 They not only offer stability and early weight-bearing but shorter operating times and cost-effectiveness compared to alternative methods.11,12

Despite the benefits, complications from the external fixator may occur. These include pain, osteitis, soft tissue impalement, neurovascular injury, compartment syndrome, refracture around a pin site, contractures, mobility challenges and pin site infection. Physiotherapy, focusing on pain management, wound healing, joint mobility, muscle strength, and gait re-education, is pivotal.3,6,11,13,14 Despite being allowed to fully weight bear with circular external fixation, many patients do not. Gait re-education supports weight-bearing and is vital for bone density preservation and reducing the risk of refracture.1516

Psychological factors are also significant, as wearing an external fixator can impact self-esteem and patient compliance with rehabilitation protocols.10,17,18 This could result in longer bone healing times and an increased risk of complications,13,19,20 underscoring the need for a holistic patient care approach.

Method

Design and procedure

This qualitative, exploratory study used semi-structured, in-depth, one-on-one interviews. Written consent, both to participate and for audio recordings, was obtained day 1 post-surgery once patients were orientated to time and place and not under the influence of anaesthesia. Participants completed a demographic questionnaire prior to the interview. A pilot study (one participant) was done to refine the interview process. After obtaining written consent, an interview was scheduled for four weeks after the surgery. Interviews took place at the researcher's private practice. Family members were used as translators in the case of non-English-speaking participants. Interviews, lasting 14 to 30 minutes, were transcribed verbatim, and thematically analysed. Anonymity was maintained through unique participant codes.

Participants

Participants in this study were patients who had undergone lower-limb circular external fixator procedures by one of three referring surgeons in Pretoria, South Africa, and who were referred for postoperative physiotherapy rehabilitation. The selection process began on the first day following their surgery, where eligible participants were identified based on inclusion and exclusion criteria. Participants were included if they were adults (18 years and older), and were cleared for full weight-bearing following the surgery with a unilateral, lower-limb circular external fixator for various purposes. Exclusion criteria included co-occurring conditions preventing full weight-bearing, being operated in another facility, for example in the government setting, concurrent intramedullary nail insertion in the ipsilateral femur, or polytrauma potentially affecting ambulation.

Data collection

Participants received an information document and consent form prior to hospital discharge. A semi-structured interview guide with possible probes was used (Table I). Demographics were gathered using a self-designed questionnaire (Table II). Field notes were recorded during and after the interviews, aiding in a better understanding of the participant and capturing non-verbal cues.

Data analysis and trustworthiness

The demographic questionnaires underwent descriptive analysis, while the feedback from the semi-structured interviews was analysed in terms of an inductive thematic analysis.21

For trustworthiness, steps were followed to ensure unbiased interviews.22

Data management and bias mitigation

Questionnaires and interviews were electronically stored with robust security measures. Bias was minimised through bracketing, acknowledging, and setting aside interviewer assumptions. Results were offered for participant review at the coding phase. Triangulation across data, investigator and theory phases ensured objectivity. Ethical considerations, including voluntary participation and confidentiality, were strictly adhered to. Informed consent was obtained from the participants, and their privacy rights were observed throughout.

Results

In this study of patients with lower-limb circular external fixators, nine interviews were conducted to explore postoperative barriers and facilitators to full weight-bearing. During the study period, a total of 15 circular external fixator procedures were performed by the referring surgeons; however, six patients were excluded for polytrauma. Participants, predominantly with chronic injuries, received the circular external fixator due to complications or deformities. Most had undergone multiple previous surgical interventions. None received dynamic struts with their current fixator. All participants experienced complications with previous procedures, leading to the current use of the circular external fixator. For detailed participant characteristics, refer to Table III.

Thematic analysis

Four themes emerged from the data collected from the interviews. They address the research question regarding the barriers and facilitators to weight-bearing with circular external fixators. Pain emerged prominently as a primary barrier, alongside various psychological factors that could either hinder or support weight-bearing. Similarly, specific physical factors related to the external fixator constructs played a crucial role. Additionally, external influences, including medical and non-medical support structures, significantly impacted participants, acting either as barriers or facilitators to weight-bearing efforts.

Theme 1: Weight-bearing is limited by pain

Pain was observed to be one of the main barriers to weight-bearing with a circular external fixator. This theme outlines the participants' experience of pain, as well as the measures to relieve pain, swelling and injury. The majority experienced pain negatively, particularly with weight-bearing while making adjustments to the external fixator. Pain affected sleep and daily functionality. Compensatory gait patterns also led to pain in unaffected joints. Swelling, pin-site pain, increased activity, and rainy weather also contributed to the pain felt. Most used assistive devices to alleviate their pain. One participant noted less pain with their current fixator, while three had desensitisation to pain due to previous experiences. Many struggled with pain medication efficacy, resorting to overdosing or experiencing side effects. Cycling, general exercises, elevation, and ice application provided relief, while precautionary measures, such as avoiding work, were taken to safeguard recovery.

Theme 2: Psychological factors influence weight-bearing

Participants' mindsets greatly influenced their ability to mobilise and bear weight. Pessimism was marked by depression, stress, anger, and a lack of confidence in the external fixator. The preoperative history of surgeries and complications played a significant role in their mental state. Fear of falling or re-injury was also an important factor. Conversely, some expressed optimism, finding hope and relief in their situation. Coping mechanisms included distraction, focusing on positive outcomes, accepting potential deformities, and finding humour in people's reactions to the fixator.

Theme 3: Physical factors affect weight-bearing

Physical factors, including walking endurance, wounds, muscle spasms, muscle atrophy and joint limitations due to stiffness, influenced weight-bearing. These factors also affected the participants' ability to sleep. Participants' preoperative strength, pain and function also played a role in postoperative outcomes. The external fixator equipment, such as pins, could cause pain and discomfort, as does pin-site bleeding and infection. The external fixator was cumbersome and difficult to manoeuvre, especially on uneven surfaces with the footplate. However, some participants felt the footplate improved their balance. Biomechanical alterations affected weight-bearing due to leg length discrepancies, weakness, and an inability to balance. The use of assistive devices also resulted in gait adjustments, affecting mobility both positively and negatively. Participants could mobilise further but placed less weight on their leg when using crutches or a walking frame. Some needed a wheelchair to continue with their activities of daily living. Other participants used a boot on their unaffected leg to correct the leg length discrepancy. Leg length discrepancies, weakness, and clothing restrictions also influenced participants' ability to mobilise. Complications with previous external fixators resulted in less weight-bearing with the current fixator.

Theme 4: Medical and non-medical support systems

Family support and community involvement played a significant role. Lack of family support led to an increased need for independence which resulted in the use of a wheelchair. The inability to drive, resulting in reliance on family members or public transport, affected participant mobility. Community safety concerns in those who lived in rural areas, also affected participants' mobility and ability to work, as did the unreliable nature of people. Participants often felt taken advantage of. Those who could work from home had no problem with working but used assistive devices to do so; others could not work as they could not drive. Trust, empathy, and the professionalism of the medical team were also crucial with honesty and trust in the surgeon being highlighted. The positivity and support from the multidisciplinary team made the participants feel positive. The immediacy of care, where necessary, also prevented complications. Furthermore, the hospital experience, as well as the nursing support, were deemed important as inadequate standards affected participants negatively. A delay in the administration of medication and a lack of care from the hospital staff resulted in increased pain and decreased weight-bearing. Adequate information and education on the circular external fixator mechanism were also valued, but some participants felt poorly instructed. Other participants understood what was required of them yet did not follow the doctor's instructions.

These results produced the barriers and facilitators to full weight-bearing with a circular external fixator, details of which can be found in Table IV.

Discussion

Clinical observations have shown that most patients with a circular external fixator do not weight-bear early enough. The study therefore aimed to explore the barriers and facilitators to full weight-bearing as early weight-bearing facilitates bone growth.23,24

Demographics

Patient demographics, including age, sex and comorbidities, significantly influenced weight-bearing ability and complication rates among those using circular external fixators for lower limb injuries. The literature suggests that younger patients tend to experience more complications, although the exact reasons remain unclear.202525,26 All participants in this study had chronic injuries, with circular external fixators used after other treatment modalities had failed. Traumatic injuries, primarily from motor vehicle or motorcycle accidents, as well as gunshot wounds, were predominant among participants. Literature points to a rising incidence of severe tibial fractures in developing countries due to poor road conditions and violent incidents.27-30 Pain significantly affected weight-bearing, particularly during external fixator adjustments. Postoperative adjustments were preferred over intraoperative adjustments to minimise intraoperative risks, according to literature.31

Fixator positioning impacted joint mobility; normal mobility during walking with a circular external fixator was feasible as long as the fixator did not cross over joints. Participants frequently faced challenges such as balance issues and leg length discrepancies due to the footplate intended to enhance stability and mobility.32,33 Many participants had undergone multiple prior procedures, which increased the likelihood of complications and impacted self-esteem.10,19 Financial pressures and the need to return to work were motivating factors noted in both the study and existing literature, influencing functional outcomes and weight-bearing ability.29,34

Barriers to full weight-bearing with circular external fixators

Some elements were a barrier and a facilitator to weight-bearing, depending on the participant, their experiences, or complications. The facilitators can, therefore, in some instances, be used as a guide to address the barriers. The barriers to full weight-bearing are described below.

Pain management

Pain stands out as the largest influencing factor to weight-bearing. Pain and pin-site infection are among the most common complications in a patient with a circular external fixator.3,11 Pain can result from various factors, including strut adjustments, tissue tension, neural tension and swelling at the pin sites. Pain management through oral analgesics is important but may lead to substance abuse or adverse effects.26,31 One of the reasons for loss of range of motion in the early postoperative phase is insufficient pain medication.35,36 In some instances, there was a better level of tolerance of pain because of having been desensitised to pain in previous experiences with their injury.

Adequacy of education

Patient education on the external fixator mechanism of action and postoperative care is crucial.3735,38 In the late 1990s, 80% of physiotherapists identified the need for better defined protocols and more information on the care of external fixator patients.6163839

Functional outcomes

The main advantage of circular external fixators is that patients can use the limb functionally for the entire treatment time, allowing for an early return to function.27,36,40,41 Some patients are overly cautious, leading to reduced functionality and weight-bearing. Assistive devices, like crutches or wheelchairs, can either facilitate or hinder weight-bearing, depending on patient usage. The work and home environment can also influence weight-bearing, with some feeling unsafe or limited in rural settings. Early weight-bearing is beneficial because it can increase the patient's functionality, and patients might then be able to return to work earlier.23

Circular external fixator components

The circular external fixator can be seen as cumbersome, heavy and difficult to manoeuvre by some patients; this makes day-to-day activities difficult, and hinders the patient's ability to walk.28,42 The physical constraints and inconvenience of the circular external fixator have been frequently mentioned in literature.3,6,11,17,43 The footplate may provide stability but can be challenging on uneven surfaces.336,29,39,44,45

Effects of patient history

Previous complications and the patient's surgical history can negatively influence their mindset, as can the cause of the injury and previous negative outcomes. Negative past experiences with surgeons can lead to a lack of trust and apathy towards the current situation. Literature states that the number of previous operations plays a significant role in managing an external fixator but does not mention the effects of previous complications or mismanagement.10,19

Psychological impact

Psychological factors, such as depression and anxiety, can be significant barriers to weight-bearing. This is because certain psychological factors may affect compliance concerning mobilisation and weight-bearing.13,19,20 Psychological issues arising from pain, as well as the psychosocial limitations from having to wear an external fixator for an extended period, resulted in patients not accepting the external fixator.31,35,36,46 Fear of falling or refracturing the leg can hinder mobility and weight-bearing. Fear of moving could also result in a loss of range of motion.35,36 Self-esteem issues and concerns about others' perceptions also affect weight-bearing.10

Physical barriers

Physical constraints of the circular external fixator, including its weight and footplate, affect gait pattern and quality of life.3,6,11,17-19,43 Muscle weakness, joint stiffness, and decreased balance and proprioception due to immobilisation limit weight-bearing.474648

Insufficient support structures

Family involvement is also important in the rehabilitation of external fixator patients; a lack of a support structure at home forces patients to rely on wheelchairs for mobility. As family members start feeling more like caregivers, there is a need to assess the impact of external fixator treatment on both the caregivers and patients.252929

Facilitators to full weight-bearing with circular external fixators

While certain barriers mentioned previously had corresponding facilitators that could mitigate these issues, participants also highlighted additional factors that supported achieving full weight-bearing, as described below.

Methods to improve function and joint range of motion

Swelling and pain may result in stiffness and immobility.6,29,33,39,44,45,49 Non-pharmacological pain relief methods, such as elevating the leg and applying ice, help reduce pain and swelling. Joint range of motion exercises and general exercises, such as cycling, can alleviate pain and improve weight-bearing. Furthermore, closed chain and weight-bearing exercises are beneficial in improving function.46

Physical measures to improve gait

Adjustments to gait, such as wearing a boot on the unaffected leg to correct leg length discrepancies and taking longer strides, aid in better weight-bearing. Specialised footwear, including a hard shoe with an elastic band for the external fixator limb, helps maintain ankle range of motion and reduce contractures.26,50 Gait re-education by physiotherapists and surgeons encourages normal gait patterns and weight-bearing.6,13,15,16 Preoperative strength and ability to balance facilitate gait and ability to weight-bear postoperatively. Therefore, the patient's ability to mobilise preoperatively should be part of the plan for postoperative preparation.3748

Psychological variations that facilitate weight-bearing

A positive mindset, hope for a positive surgical outcome, and mental distraction from pain contribute to improved weight-bearing. Functional outcome assessment based on the psychological acceptance of the procedure and the degree of the disability improved the physical aspects of the patient over time.5146

Benefits of the multidisciplinary medical team

Expert care from a multidisciplinary team addresses patients' social, physical and psychological needs.4639 33,45

Although the surgeries were conducted in the private sector, the sample population was from both rural and urban areas, with different levels of familial support. The support of the medical team, as well as patient and family education, were of utmost importance, and further research in the government sector may provide important information as there is a stark difference in care between the two sectors. Despite this, understanding all the above-mentioned factors is crucial for promoting early weight-bearing with circular external fixators, which can facilitate bone growth and patient recovery.

Limitations of the study include the data saturation point that was reached after interviewing nine participants. A larger sample size over a longer period might have yielded more results. All the participants' injuries were chronic by nature and associated with previous failed interventions, as, owing to polytrauma, acute patients were excluded as potential participants for this study. This study was also limited to a South African private sector context; therefore, more social and cultural diversity could have assisted in being truly reflective.

Conclusion

The findings of this study emphasise the importance of addressing physical and psychological factors affecting rehabilitation. Further research and the implementation of solutions to address these factors in physiotherapy practice are warranted in this context. These findings are consistent with the limited existing literature on the rehabilitation of external fixators and provide valuable insights into the barriers and facilitators to full weight-bearing.

Declaration of generative AI and AI-assisted technologies

During the preparation of this work, the authors used Chat GPT in order to improve language and readability in the condensation of information. After using this service, the authors reviewed and edited the content as needed and take full responsibility for the content of the publication.

Ethics statement

The authors declare that this submission is in accordance with the principles laid down by the Responsible Research Publication Position Statements as developed at the 2nd World Conference on Research Integrity in Singapore, 2010. Prior to commencement of the study, ethical approval was obtained from the University of the Witwatersrand Human Research Ethics Committee (Medical), reference number M210723. All participants gave written informed consent before data collection began. All procedures were in accordance with the ethical standards of the responsible committee on human experimentation (institutional and national) and with the Helsinki Declaration of 1975, as revised in 2008.

Declaration

The authors declare authorship of this article and that they have followed sound scientific research practice. This research is original and does not transgress plagiarism policies.

Author contributions

MDC: conceptualisation, data curation, formal analysis, funding acquisition, investigation, methodology, project administration, visualisation, writing original draft, review and editing, final approval of the version to be submitted SL: conceptualisation, supervision, review and editing, final approval of the version to be submitted

MMK: conceptualisation, supervision, review and editing, final approval of the version to be submitted

ORCID

Crouse MD https://orcid.org/0009-0007-9463-3608

Lord S https://orcid.org/0000-0002-5279-5875

Keller M https://orcid.org/0000-0002-1513-295X

References

  • 1. Hernigou P. History of external fixation for treatment of fractures. International Orthopaedics. Springer Verlag. 2016;41:845-53.
  • 2. Amaro AM, Paulino MF, Roseiro LM, Neto MA. The effect of external fixator configurations on the dynamic compression load: An experimental and numerical study. Appl Sci. 2020;10(1).
  • 3. Bhardwaj R, Singh J, Kapila R, Boparai RS. Comparison of Ilizarov ring fixator and rail fixator in infected nonunion of long bones: A retrospective follow-up study. Indian J Orthop. 2019;53(1):82-88.
  • 4. Prakash DS, Rao DV, Hardikar DS, Pagdal DS. External fixators in management of high energy distal third tibia fractures. Int J Orthop Sci. 2019;5(2).
  • 5. Fragomen AT, Rozbruch SR. The mechanics of external fixation. HSS J. 2007 Feb;3(1):13-29. https://doi.org/10.1007/s11420-006-9025-0
    » https://doi.org/10.1007/s11420-006-9025-0
  • 6. Barker K, Burns M, Littler S. Physiotherapy for patients with an Ilizarov external fixator: a survey of current practice. Physiotherapy. 1999;85(8):426-32.
  • 7. Ganadhiepan G, Miramini S, Patel M, et al. Bone fracture healing under Ilizarov fixator: Influence of fixator configuration, fracture geometry, and loading. Int J Numer Method Biomed Eng. 2019;35(6):3199-217.
  • 8. Morasiewicz P, Dejnek M, Kulej M, et al. Sport and physical activity after ankle arthrodesis with Ilizarov fixation and internal fixation. Adv Clin Exp Med. 2019;28(5):609-14.
  • 9. Reinke C, Lotzien S, Yilmaz E, et al. Tibiocalcaneal arthrodesis using the Ilizarov fixator in compromised hosts: an analysis of 19 patients. Arch Orthop Trauma Surg. 2022 Jul;142(7):1359-66. https://doi.org/10.1007/s00402-021-03751-0. Epub 2021 Jan 23
    » https://doi.org/10.1007/s00402-021-03751-0
  • 10. Siddiqui AA, Siddiqui F, Bashar M, et al. Impact of Ilizarov fixation technique on the limb functionality and self-esteem of patients with unilateral tibial fractures. Cureus. 2019;11(10):1-6.
  • 11. Abd Aziz AU, Abdul Wahab AH, et al. A finite element study: finding the best configuration between unilateral, hybrid, and Ilizarov in terms of biomechanical point of view. Injury. 2020;51(11):2474-78.
  • 12. Garg P, Sodha R, Bin Hamid F, Somashekarappa T. Clinical study of functional outcome of external fixator device as a primary definitive treatment of open tibia fracture. Medico-Legal Updat. 2021;21(1):768-71.
  • 13. Elbatrawy Y, Ragab IMA. Safe cosmetic leg lengthening for short stature: long-term outcomes. Orthopedics. 2015;38(7):552-60.
  • 14. Green S. Physiotherapy during Ilizarov fixation. Tech Orthop. 1990;5(4):61-65.
  • 15. Zhang L. Early rehabilitation and bone mineral density in patients with functional disorders of the knee joint caused by lower limb fracture. J Clin Rehabil Tissue Eng Res. 2010;14(33):6234-37.
  • 16. Barker K, Burns M. Using consensus techniques to produce clinical guidelines for patients treated with the Ilizarov fixator. Physiotherapy. 2001;87(6):289-300.
  • 17. Gubin AV, Borzunov DY, Malkova TA. The Ilizarov paradigm: thirty years with the Ilizarov method, current concerns and future research. Int Orthop. 2013;37:1533-39.
  • 18. Vitale K, Miller T, Jimenez AC. Rehabilitation after intramedullary skeletal kinetic distractor implantation: a report of two cases and a suggested therapy program. Am J Phys Med Rehabil. 2006;85(2):176-80. https://doi.org/10.1097/01.phm.0000193508.62984.7f
    » https://doi.org/10.1097/01.phm.0000193508.62984.7f
  • 19. Naqui SZH, Thiryayi W, Foster A, et al. Correction of simple and complex pediatric deformities using the Taylor-spatial frame. J Pediatr Orthop. 2008;28(6):640-47.
  • 20. Oh CW, Apivatthakakul T, Oh JK, et al. Bone transport with an external fixator and a locking plate for segmental tibial defects. Bone Joint J. 2013;95-B(12):1667-72. https://doi.org/10.1302/0301-620X.95B12.31507
    » https://doi.org/10.1302/0301-620X.95B12.31507
  • 21. Green J, Willis K, Hughes E, et al. Generating best evidence from qualitative research: The role of data analysis. Aust N Z J Public Health. 2007;1;31(6):545-50.
  • 22. Elo S, Kääriäinen M, Kanste O, et al. Qualitative content analysis. SAGE Open. 2014 Jan 7;4(1):215824401452263.
  • 23. Augat P, Hollensteiner M, von Rüden C. The role of mechanical stimulation in the enhancement of bone healing. Injury [Internet]. 2020;52(2):S78-83. https://doi.org/10.1016/j.injury.2020.10.009
    » https://doi.org/10.1016/j.injury.2020.10.009
  • 24. Fenton C, Henderson D, Samchukov M, et al. Comparative stiffness characteristics of Ilizarov- and Hexapod-type external frame constructs. Strateg Trauma Limb Reconstr. [Internet]. 2021;16(3):138-43.
  • 25. Reid JS, Vanderkarr M, Ray B, et al. Two-year clinical and economic burden, risk and outcomes following application of software-assisted hexapod ring fixation systems. BMC Musculoskelet Disord [Internet]. 2022;23(1):25. https://doi.org/10.1186/s12891-021-04934-x
    » https://doi.org/10.1186/s12891-021-04934-x
  • 26. Liu Y, Liu K, Cai F, et al. Retrospective clinical outcomes in the definitive treatment of high-energy tibial diaphyseal fractures using hexapod external fixator versus monolateral external fixator. BMC Musculoskelet Disord. [Internet]. 2022;23(1):330. https://doi.org/10.1186/s12891-022-05257-1
    » https://doi.org/10.1186/s12891-022-05257-1
  • 27. Sheng H, Xu W, Xu B, et al. Application of intelligent computer-assisted Taylor 3-D external fixation in the treatment of tibiofibular fracture: retrospective case study. J MIR Med Inf. 2021;9(5).
  • 28. Alqahtani MS, Al-Tamimi AA, Hassan MH, et al. Optimization of a patient-specific external fixation device for lower limb injuries. Polym. [Internet]. 2021;13(16):2661. https://doi.org/10.3390/polym13162661
    » https://doi.org/10.3390/polym13162661
  • 29. Cinthuja P, Wijesinghe PCI, Silva P. Use of external fixators in developing countries: a short socioeconomic analysis. Cost Eff Resour Alloc. [Internet]. 2022;20(1):14. https://doi.org/10.1186/s12962-022-00353-4
    » https://doi.org/10.1186/s12962-022-00353-4
  • 30. Milenkovic SS, Mitkovic MM, Mitkovic MB, et al. Unilateral 3-D external fixation in Serbian traumatology and orthopaedics. Int J Clin Med [Internet]. 2021;75(9). https://doi.org/10.1111/ijcp.14411
    » https://doi.org/10.1111/ijcp.14411
  • 31. Liu Y, Cai F, Liu K, et al. Intra-operative acute correction versus post-operative gradual correction for tibial shaft fractures with multiplanar post-traumatic deformities using the hexapod external fixator. BMC Musculoskelet Disord. [Internet]. 2021;22(1):803. https://doi.org/10.1186/s12891-021-04505-0
    » https://doi.org/10.1186/s12891-021-04505-0
  • 32. Tripathy SK, Varghese P, Panigrahi S, et al. External fixation versus open reduction and internal fixation in the treatment of complex tibial plateau fractures: a systematic review and meta-analysis. Acta Orthop Traumatol Turc. 2021;55(5):444-56.
  • 33. Martin B, Chow J. The use of circular-frame external fixation in the treatment of ankle/ hindfoot Charcot neuroarthropathy. J Clin Orthop Trauma. [Internet]. 2021;16:269-76. https://doi.org/10.1016/j.jcot.2021.02.016
    » https://doi.org/10.1016/j.jcot.2021.02.016
  • 34. Sengodan VC, Sengodan MM. Early weight-bearing using percutaneous external fixator for calcaneal fracture. J Surg Tech Case Rep. 2012;4(2):98-102. https://doi.org/10.5005/jp-journals-10080-1539
    » https://doi.org/10.5005/jp-journals-10080-1539
  • 35. Barker KL, Simpson AH, Lamb SE. Loss of knee range of motion in leg lengthening. J Orthop Sport Phys Ther [Internet]. 2001;31(5):238-44. https://doi.org/10.2519/jospt.2001.31.5.238
    » https://doi.org/10.2519/jospt.2001.31.5.238
  • 36. Malkova TA, Borzunov DY. International recognition of the Ilizarov bone reconstruction techniques: Current practice and research (dedicated to the 100th birthday of G. A. Ilizarov). World J Orthop [Internet]. 2021;12(8):515-33. https://doi.org/10.5312/wjo.v12.i8.515
    » https://doi.org/10.5312/wjo.v12.i8.515
  • 37. Robbins CA. Deformity reconstruction surgery for Blount's Disease. Child [Internet]. 2021;8(7):566. https://doi.org/10.3390/children8070566
    » https://doi.org/10.3390/children8070566
  • 38. Lally P, Seligson D, Stanwyck TS. The new challenges of physical therapy for external fixation treatment of fractures. J Orthop Sport Phys Ther. [Internet]. 1981;2(4):171-76. https://doi.org/10.2519/jospt.1981.2.4.171
    » https://doi.org/10.2519/jospt.1981.2.4.171
  • 39. Hadeed A, Werntz RL, Varacallo M. External fixation principles and overview. Stat Pearls. 2022. https://www.ncbi.nlm.nih.gov/books/NBK547694/
    » https://www.ncbi.nlm.nih.gov/books/NBK547694/
  • 40. Reddy AK, Radhakrishna R. A study of outcome of open supracondylar fracture femur treated with Ilizarov fixator as primary management. J Evol Med Dent Sci. 2019;8(40):3024-27.
  • 41. Zein AB, Elhalawany AS, Ali M, et al. Acute correction of severe complex adolescent late-onset tibia vara by minimally invasive osteotomy and simple circular fixation: a case series with a two-year minimum follow-up. BMC Musculoskelet Disord. [Internet]. 2021;22(1):681. https://doi.org/10.1186/s12891-021-04496-y
    » https://doi.org/10.1186/s12891-021-04496-y
  • 42. Hidayat L, Triangga AFR, Cein CR, et al. Low profile external fixation using locking compression plate as treatment option for management of soft tissue problems in open tibia fracture grade IIIA: A case series. Int J Surg Case Reports. [Internet]. 2022;93. https://doi.org/10.1016/j.ijscr.2022.106882
    » https://doi.org/10.1016/j.ijscr.2022.106882
  • 43. Horas K, Schnettler R, Maier G, et al. The role of soft-tissue traction forces in bone segment transport for callus distraction: a force measurement cadaver study on eight human femora using a novel intramedullary callus distraction system. Strateg Trauma Limb Reconstr. 2015 Apr 1;10(1):21-26.
  • 44. Bayrak A, Polat Ö, Ursavaş HT, et al. Which external fixation method is better for the treatment of tibial shaft fractures due to gunshot injury? Orthop Traumatol Surg Res. [Internet]. 2021;108(5). https://doi.org/10.1016/j.otsr.2021.102948
    » https://doi.org/10.1016/j.otsr.2021.102948
  • 45. Biz C, Crimi A, Fantoni I, et al. Functional outcome and complications after treatment of comminuted tibial fractures or deformities using Ilizarov bone transport: a single-center study at 15- to 30-year follow-up. Arch Orthop Trauma Surg. [Internet]. 2020;11:1825-33. https://doi.org/10.1007/s00402-020-03562-9
    » https://doi.org/10.1007/s00402-020-03562-9
  • 46. Sims M, Bennett N, Broadley L, et al. External fixation: Part 2. J Orthop Nurs. [Internet]. 2000;4(1):26-32. https://doi.org/10.1054/joon.2000.0049
    » https://doi.org/10.1054/joon.2000.0049
  • 47. Pawik Ł, Pajchert-Kozlowska A, Szelerski Ł, et al. Assessment of lower-limb load distribution in patients treated with the Ilizarov method for tibial non-union. Med Sci Monit. 2021;27.
  • 48. Zak L, Wozasek GE. Impaired joint motion and contractures in callus distraction and segment transport: A retrospective data analysis. Wien Klin Wochenschr. 2013;125:21-22.
  • 49. Reis ND. A philosophy of limb salvage in war: use of the fixateur externe. Mil Med. 1991;156(10):505.
  • 50. Donnan LT, Gomes B, Donnan A, et al. Ilizarov tibial lengtheningin the skeletallyimmature patient. Bone Joint J. 2016;98-B(9):1276-82. https://doi.org/10.1302/0301-620X.98B10.37523
    » https://doi.org/10.1302/0301-620X.98B10.37523
  • 51. Jin L, Zhang S, Zhang Y, et al. Management algorithm of external fixation in lower leg arterial injury for limb salvages. Br Med Counc Surg. [Internet]. 2022;22(1):79. https://doi.org/10.1186/s12893-022-01486-2
    » https://doi.org/10.1186/s12893-022-01486-2

Received: April 2024
Accepted: August 2024
Published: November 2024

Editor: Prof. Nando Ferreira, Stellenbosch University, Cape Town, South Africa
Funding: Partial funding was received from the South African Society of Physiotherapy, with no conflict of interest as the funder had no role in the study.
Conflict of interest: Although partial funding was received from the South African Society of Physiotherapy, there was no conflict of interest as the funder had no role in the study.
* Corresponding author:

Correspondence

megan@myphysio.org.za

Publication Dates

  • Publication in this collection
    08 Jan 2025
  • Date of issue

History

  • Received
  • Accepted
location_on
Medpharm Publications South African Orthopaedic Association (SAOA), P.O. Box 12918, Brandhof, Bloemfontein, Free State, ZA, 9324, Tel: +27 51 430 3280 - E-mail: pat@saoj.co.za
rss_feed Acompanhe os números deste periódico no seu leitor de RSS
Ir para o topo