Vuvuzela sound measurements
To the Editor: Our recent paper in the SAMJ1
One commercial vuvuzela was used in the recording of sound levels at 4 different positions: (i) at the ear of the person blowing the vuvuzela; (ii) at the bell end; (iii) 1 m from the bell end; and (iv) 2 m from the bell end. All measurements were made approximately 1.6 m from the ground, in an openair setting. Sound levels were measured twice at a single instance while the vuvuzela was being blown by one of the investigators. Measurements were made using a calibrated Type 1 Larson Davis SLM 824 sound level meter with a 2559 normal sensitivity microphone fitted with a manufacturersupplied windscreen (WS001). Measurements were made using the fast response time option, which corresponds to a time constant of 0.125 s that is intended to approximate the time constant of human hearing.2
The initial report12Table I. A characteristically flat frequency spectrum was evident between 250 and 8 000 Hz. The average intensity difference between the individual frequency measurements (Table I) of the 2 recordings at each of the 4 respective distances from the bell of the vuvuzela was 0.6 dB (±3.2 dB standard deviation).
These measures provide an indication of the sound levels and frequency spectrum of a typical vuvuzela. There are now numerous types of vuvuzela made by several manufacturers, which may all produce varying intensity and frequency outputs. In addition to these variables, individuals blowing a vuvuzela will produce varying intensities depending on their technique and the pressure exerted. Also, the sound level produced by multiple individuals simultaneously blowing vuvuzelas within a limited space cannot be predicted from these data.
De Wet Swanepoel
Department of Communication Pathology
University of Pretoria, and Callier Center for Communication Disorders
University of Texas
Dallas, USA
James W Hall III
Department of Communication Pathology
University of Pretoria, and Department of Communicative Disorders
University of Florida
Gainesville, Fla, USA
Dirk Koekemoer
Research and Development Department
GeoAxon
Pretoria