Open-access Potential pitfalls in the anorectal region during CT colonography: A discussion and pictorial overview of common pitfalls

Abstract

Common potential anorectal pitfalls are presented with accompanying CT colonography images. Although most lesions are benign, care must be taken in not missing an underlying cancer.


Introduction

It is highly likely that requests for computer tomographic colonography (CTC) will increase because it was very recently added to the colorectal cancer screening tests in the United States.123,4353

Based on the author's experience, having performed > 6000 CTC examinations, the most common technical-related potential pitfalls (placement of the rectal catheter, stool and artefacts) and pathology-related pitfalls (internal haemorrhoids, polyps, cancer, hypertrophied anal papilla, perforation because of OC complications, and extrinsic impressions) are described with CTC images.2,4,6,7,89

Rectum anatomy

The rectum is mostly a retroperitoneal organ commencing at the mid-sacral level and ending in the anal canal; its average length is 15 cm. It does not have haustral markings. The longitudinal taenia coli end at the rectosigmoid junction and continue only as a smooth muscle layer in the rectum.1011Figure 1). It indicates the level of the abdomino-peritoneal reflection anteriorly; it is typically 8 cm from the anal verge and demarcates the lower and middle third of the rectum.11Figure 2) represents the anatomic anorectal line, which is identified by an undulating demarcation in the rectal mucosa about 3 cm above the anal verge.10

Technical-related pitfalls

A rectal catheter can cause interpretation problems.1213Figure 3). The catheter may obscure pathology in some patients.66,9

Figure 3

Figures 4 to 6 illustrate several catheter-related pitfalls. The catheter may impinge on the valve of Houston causing an extrinsic impression. If CO2 flow is obstructed by any cause, deflate the balloon, pull back on the catheter until flow resumes and then re-inflate the balloon. An inflated balloon may cause a defect called the meniscus sign;14Figure 7. 2D and 3D views are complementary, and if available translucent display (TD) shows what lies beneath the surface. This software displays different colour attenuation values: red indicates soft tissue; white indicates high attenuation values, such as barium; green indicates negative values in the fat attenuation range; and blue indicates negative values, such as air.14

Figure 7

Occasionally, the rectal tube itself may obscure a sessile polyp in the rectum. The author's standard technique is to perform a 360° fly around the rectal catheter to ensure adequate visualisation of all surrounding features. Incomplete collapse of the balloon may cause artefacts that appear as polypoidal lesions.

Artefacts are an unwanted feature on a CTC image that may obscure or simulate pathology.156,16

Figure 8 illustrates some stool-related pitfalls. Stool may present as a polypoidal lesion on 3D endoluminal flythrough. It may move to the dependant bowel surface between the two-view study (supine and prone), which differentiates it from a sessile polyp.1616

Figure 8

It is important to be familiar with the appearance of artefacts; they can obscure lesions or be mistaken for pathology. Hip prosthesis-related artefacts are because of beam hardening and scatter, which cause dark streak artefacts. Software is available to reduce beam hardening effects.1715Figure 9 shows these types of artefacts. Artefact-related pitfalls are fairly common. Figure 10 illustrates that an air bubble artefact may appear to be a lesion. The 'dense waterfall' sign (Figure 11) is an artefact that is related to actively flowing opacified luminal fluid.18

Figure 9

Figure 10

Figure 11

Pathology-related pitfalls

Internal haemorrhoids are the most frequently seen and diagnosed condition affecting the anorectal region.144Figure 12). Rectal varices, in contrast to haemorrhoids, have a tubular, serpiginous appearance.2,43,6,1616 Figure 13 presents examples of the importance of deflating the balloon in the prone study for visualisation of internal haemorrhoids.

Figure 12

Figure 13

Internal haemorrhoids may be confused with a hypertrophied anal papilla, a benign condition occurring in response to chronic irritation or anal fissuring.333Figure 14). A polyp would be a short distance from the catheter.

Figure 14

Polyps may be sessile or pedunculated. On 3D, they present as polypoid lesions, and they are homogeneous on 2D. Sessile polyps do not move and usually have a thin covering of barium on their surface. The shape and form of flat lesions and carpet lesions are potential pitfalls.19Figure 15).33,2021

Figure 15

Flat lesions are usually < 30 mm in size and are elevated approximately 3 mm above the colonic mucosa. They are a subset of sessile polyps that do not have a polypoidal appearance22Figure 16) or laterally spreading tumours.2319,23

Figure 16

When evaluating anorectal CTC images, we need to consider the possibility of a malignant lesion. A cancer has an irregular polypoid appearance with thickening of the bowel wall. Figure 17 shows rectal cancer. Rectal tumours may be aggressive in immunocompromised patients, particularly those who have the acquired immunodeficiency syndrome.3

Figure 17

We need to be mindful of possible perforations caused by diagnostic and therapeutic procedures at OC.7,24,2524Figure 18). Before commencing a CTC following an incomplete or failed OC, it is essential to exclude perforation. A pre-procedure low-dose CT scan is performed to assess whether free air is present, and if visualised, the CTC study is not performed.1616,25,26

Figure 18

Any structure that lies adjacent to the colon may cause an extrinsic impression on the colon lumen. 14Figure 19).

Figure 19

Conclusion

Potential anorectal region pitfalls may be related to technique, interpretation or specific anatomical features.2,3,4

Competing interests

The author declares that he has no financial or personal relationships which may have inappropriately influenced him in writing this article.

Acknowledgements

Clinton Bopp is thanked for drawing the line diagrams of the anatomy of the rectum and internal haemorrhoids. Professor D Kim, Wisconsin University, is thanked for the carpet lesion images. Mrs. Leonie Munro for assisting with the editing and proofreading of this article.

References

  • 1. Bibbins-Domingo K, Grossman DC, Curry SJ, et al. Screening for colorectal cancer: US Preventive Services Task Force Recommendation Statement. JAMA. 2016;315:2564-2575. https://doi.org/10.1001/jama.2016.5989
    » https://doi.org/10.1001/jama.2016.5989
  • 2. Lefere P, Gryspeerdt S. CT colonography: Avoiding traps and pitfalls. Insights Imaging. 2011;2:57-68. https://doi.org/10.1007/s13244-010-0054-3
    » https://doi.org/10.1007/s13244-010-0054-3
  • 3. Pickhardt PJ. Screening CT colonography: How I do it. AJR. 2007;189(2):290-298. https://doi.org/10.2214/ajr.07.2136
    » https://doi.org/10.2214/ajr.07.2136
  • 4. Pickhardt PJ, Kim DH. CT colonography: Pitfalls in interpretation. Radiol Clin North Am. 2013;51:69-88. https://doi.org/10.1016/j.rcl.2012.09.005
    » https://doi.org/10.1016/j.rcl.2012.09.005
  • 5. Spada C, Stoker J, Alarcon O, et al. Clinical indications for computed tomographic colonoscopy: European Society of Gastrointestinal Endoscopy (ESGE) and European Society of Gastrointestinal and Abdominal Radiology (ESGAR) guideline. Eur Radiol. 2015;25:331-345. https://doi.org/10.1007/s00330-014-3435-z
    » https://doi.org/10.1007/s00330-014-3435-z
  • 6. Pickhardt PJ. Differential diagnosis of polypoidal lesions seen at CT colonography (virtual colonoscopy). RadioGraphics. 2004;24(6):1535-1556. https://doi.org/10.1148/rg.246045063
    » https://doi.org/10.1148/rg.246045063
  • 7. Kim DH, Pickhardt PJ, Taylor AJ, Menias CO. Imaging evaluation of complications at optical colonoscopy. Curr Probl Diagn Radiol. 2008;37:165-177. https://doi.org/10.1067/j.cpradiol.2007.10.004
    » https://doi.org/10.1067/j.cpradiol.2007.10.004
  • 8. Daly B, Lu M, Pickhardt PJ, Menias CO, Abbas MA, Katz DS. Complications of optical colonoscopy: CT findings. Radiol Clin North Am. 2014;52:1087-1099. https://doi.org/10.1016/j.rcl.2014.05.012
    » https://doi.org/10.1016/j.rcl.2014.05.012
  • 9 Bortz JH. CTC technique and methods of interpreting images. In: Bortz JH et al., editors. CT colonography for radiographers: A guide to performance and image interpretation. Basel: Springer; 2016; p. 103-123.
  • 10. Netter F. The Ciba collection of medical illustrations. Volume 3. Digestive system. Part 2. Lower digestive tract. New York: Colour Press; 1962; p. 58.
  • 11. Abramson DJ. The valves of Houston in adults. Am J Surg. 1978;c136:334-336.
  • 12. Pickhardt PJ, Choi JR. Adenomatous polyp obscured by small-caliber rectal catheter at low-dose CT colonography: A rare diagnostic pitfall. AJR. 2005;184:1581-1583. https://doi.org/10.2214/ajr.184.5.01841581
    » https://doi.org/10.2214/ajr.184.5.01841581
  • 13. Macari M, Bini EJ. CT colonography: Where have we been and where are we going? Radiology. 2005;237:818-833. https://doi.org/10.1148/radiol.2373041717
    » https://doi.org/10.1148/radiol.2373041717
  • 14. Pickhardt PJ, Kim DH. CT colonography: Principles and practice of virtual colonoscopy. Philadelphia, PA: Saunders; 2009; p. 213-214, 312.
  • 15. Boas FE, Fleischmann D. CT artefacts: Causes and reduction techniques. Imaging Med. 2012;4(2):229-240. https://doi.org/10.2217/iim.12.13
    » https://doi.org/10.2217/iim.12.13
  • 16. Bortz JH. CT colonography: An approach for a successful examination. S Afr J Rad. 2014;18(1). http://dx.doi.org/10.4102/sajr.v18i1.607
    » http://dx.doi.org/10.4102/sajr.v18i1.607
  • 17. Bannas P, Li Y, Motosugi U, et al. Prior image constrained compressed sensing metal artifact reduction (PICCS-MAR): 2D and 3D image quality improvement with hip prostheses at CT colonography. Eur Radiol. 2016;26(7):2039-2049. https://doi.org/10.1007/s00330-015-4044-1
    » https://doi.org/10.1007/s00330-015-4044-1
  • 18. Boyce CJ, Vetter JR, Pickhardt PJ. MDCT artefact related to the intra-scan gravitational flow of opacified luminal fluid (the "Dense Waterfall" sign). Abdominal Imaging. 2012;37(2):292-296. https://doi.org/10.1007/s00261-011-9731-z
    » https://doi.org/10.1007/s00261-011-9731-z
  • 19. Galdino GM, Yee J. Carpet lesion on CT colonography: A potential pitfall. AJR 2003;180:1332-1334. https://doi.org/10.2214/ajr.180.5.1801332
    » https://doi.org/10.2214/ajr.180.5.1801332
  • 20. Pickhardt PJ, Kim DH. Colorectal cancer screening with CT colonography: Key concepts regarding polyp prevalence, size, histology, morphology, and natural history. AJR. 2009;193:40-46. https://doi.org/10.2214/AJR.08.1709
    » https://doi.org/10.2214/AJR.08.1709
  • 21. Kim DH, Pickhardt PJ, Taylor AJ, et al. CT colonography versus colonoscopy for detection of advanced neoplasia. N Eng J Med. 2007;357(14):1403-1412. https://doi.org/10.1056/NEJMoa070543
    » https://doi.org/10.1056/NEJMoa070543
  • 22. Yee J, Chang KJ, Dachman AH, et al. The added value of the CT colonography reporting and data system. JACR. 2016;13(8):931-935. https://doi.org/10.1016/j.jacr.2016.04.031
    » https://doi.org/10.1016/j.jacr.2016.04.031
  • 23. Pickhardt PJ, Lam VP, Weiss JM, et al. Carpet lesions detected at CT colonography: Clinical, imaging, and pathologic features. Radiology. 2014;270:435-443. https://doi.org/10.1148/radiol.13130812
    » https://doi.org/10.1148/radiol.13130812
  • 24. Bortz JH. Introduction. In: Bortz JH et al., editors. CT colonography for radiographers: A guide to performance and image interpretation. Basel: Springer; 2016; p. 1-8.
  • 25. Pickhardt PJ. Incidence of colonic perforation at CT colonography: Review of existing data and implication for screening of asymptomatic adults. Radiology. 2006;239(2):313-316. https://doi.org/10.1148/radiol.2392052002
    » https://doi.org/10.1148/radiol.2392052002
  • 26. Neri E, Halligan S, Hellström M, et al. The second ESGAR consensus statement of CT colonography. Eur Radiol. 2013;23:720-729. https://doi.org/10.1007/s00330-012-2632-x
    » https://doi.org/10.1007/s00330-012-2632-x

Correspondence:
Joel Bortz

Received: 05 Oct. 2016
Accepted: 09 Nov. 2016
Published: 28 Feb. 2017

Correspondence

joelbortzmd@gmail.com

Publication Dates

  • Publication in this collection
    16 Nov 2020
  • Date of issue

History

  • Received
    05 Oct 2016
  • Accepted
    09 Nov 2016
location_on
Radiological Society of South Africa AOSIS Publishing, Postnet Suite #110, Private Bag X19, Durbanville, Cape Town, Western Cape Province, ZA, 7551, Tel: +27 21 975 2602, Tel: 086 1000 381 - E-mail: publishing@aosis.co.za
rss_feed Acompañe los números de esta revista en su lector de RSS
Ir para arriba