Open-access Diagnostic performance of dual-energy CT with electron-density reconstruction for lumbar disc herniation

Abstract

BACKGROUND: Magnetic resonance imaging (MRI) is used for the evaluation of degenerative spinal disease. However, its utility is restricted in routine practice because of contraindications and a lack of widespread availability. Dual-energy computed tomography (DECT) is a newer technique for the evaluation of degenerative spinal disease. OBJECTIVES: This study aimed to evaluate the diagnostic performance of DECT with electron-density (ED) image reconstruction compared to standard CT for the detection of lumbar disc herniation, with MRI as the gold standard. METHOD: The retrospective study included 84 patients between 01 July 2023 to 31 December 2023 who underwent DECT and 1.5-T MRI within 1 week. Four radiologists, blinded to the clinical and MRI information, independently evaluated the standard CT series and DECT series with ED reconstructions for lumbar disc herniation and spinal nerve root impingement. The gold standard for comparison was lumbar spine MRI, and diagnostic accuracy was measured with sensitivity and specificity. RESULTS: MRI revealed 417 lumbar disc herniations. Dual-energy computed tomography with ED reconstruction showed higher sensitivity (86.36% [532/616] vs. 57.79% [356/616]) and specificity (96.86% [1019/1052] vs. 95.82% [1008/1052]) for the detection of lumbar disc herniation compared to standard CT. CONCLUSION: Dual-energy computed tomography with ED reconstruction shows better diagnostic performance for the detection of lumbar disc herniation compared to standard CT and can be a useful alternative imaging modality when MRI is contraindicated or unavailable. CONTRIBUTION: This study shows the usefulness of DECT as an alternative imaging technique for screening of degenerative spinal disease whenever MRI is contraindicated or unavailable.

dual-energy computed tomography; electron-density reconstruction; magnetic resonance imaging; lumbar disc; intervertebral disc herniation; spinal nerve root impingement; standard computed tomography; retrospective study


Introduction

The intervertebral disc is a cartilaginous structure comprising the annulus fibrosus (AF) and nucleus pulposus (NP). At the core of the disc is the NP, a gel-like material made of water and proteoglycans, held together by randomly arranged collagen fibres. The NP is surrounded by the ring-shaped AF, which is made up of 15-25 stacked sheets of collagen. Intervertebral disc disease is characterised by a decrease in proteoglycan content, resulting in dehydration in the NP, leading to morphological abnormalities and variations in its biomechanical properties.1

Unenhanced lumbar spine CT is the principal modality to evaluate bone abnormalities such as fractures or any bone disorders because of its superiority over MRI for osseous detail.23,4

Recent studies have endeavoured to identify disc herniation through the use of advanced CT imaging techniques such as Dual-energy computed tomography (DECT).3,5,6,7,8 Notably, recent publications have highlighted the value of three-material decomposition-based virtual non-calcium (VNCa) imaging for determining the presence of bone marrow oedema and identifying collagenous structures such as ligaments and tendons.9,10,11 Colour-coded VNCa imaging, in particular, has been found to be useful for the detection of disc pathology as observed by Booz et al.3

The Hounsfield unit (HU) value of each pixel on CT images is converted to create electron-density (ED) images, and the applied radiation dose is determined using a calibration curve specific to the scanner. As a calibration-free technique, single-source dual-layer DECT currently provides a more accurate ED map without conversion to HU. It permits ED imaging by distinguishing between Compton scattering and photoelectric effect attenuation, and measuring attenuation at two separate energies. The material density mostly affects Compton scattering, but in the high-energy range - such as during radiation therapy - the ED depends on Compton scattering. Although ED maps are frequently used to calculate radiation doses in radiation oncology, diagnostic radiology has not made much use of this technology.3,12

Shim et al., in a cross-sectional study on 64 patients (336 intervertebral discs), showed DECT with ED reconstruction can improve cervical disc herniation detection and diagnostic confidence compared with standard CT and VNCa images.12

Research methods and design

A retrospective study was conducted at the Department of Radiodiagnosis, Krishna Rajendra Hospital, Mysore Medical College and Research Institute in Mysore, India. All patients with low backache who underwent MRI and DECT within a 1-week period from 01 July 2023 to 31 December 2023 were included. Patients with a history of previous surgery (with metallic implants or intervertebral disc surgeries), spinal tumours or infections, a history of trauma and vertebral anomalies were excluded. The study population selection is presented in Figure 1.

CT protocol

Non-contrast CT scans were acquired using a single-source, 128-slice dual-energy CT system (Somatom definition edge; Siemens Healthineers, Erlangen, Germany). By utilising a Sn (tin filter) and Au (gold filter), the X-ray tube was operated at 120 kV and 440 mAs. A dual-energy protocol (rotation time: 0.33 s; pitch factor: 0.35; collimation: 38 mm × 0.6 mm) was used to perform CT in the craniocaudal direction. Mean volume CT dose index was 11.683 mGy (range, 9.730 mGy - 14.060 mGy) and mean dose-length product was 478.099 mGy.cm (range, 350.770 mGy.cm - 691.900 mGy.cm).

Three separate sets of images were obtained in each dual-energy CT scan: Au120 kVp, Sn120 kVp, and weighted average (ratio, 0.5:0.5) to resemble the contrast provided by a single-energy 120-kVp image. This was followed by generation of axial and sagittal reconstructions (1 mm section thickness) with a specific dual-energy medium-soft convolution kernel. Post-processing was performed using commercially available universal imaging software (syngo.via, version VB60A_HF02; Siemens Healthineers, Erlangen, Germany). An ED reconstruction algorithm optimised for analysis of intervertebral discs was applied by using dedicated software settings (colour lookup tables low-energy value, spectrum; colour lookup tables high-energy value, grayscale; CT preset 1-liver). The DECT axial and sagittal ED reconstructions and standard CT series were used for image analysis. The readers were allowed to freely change the window width and level during the image assessment in order to improve the detection of disc herniation.

Magnetic resonance imaging protocol

All patients underwent non-contrast MRI with a 1.5-T system (uMR 570; 24 channel United Imaging, Jiading, Shanghai, China) using a dedicated spine surface coil. Standard T1-weighted fast spin-echo (repetition time msec/echo time msec, 615/8.3; matrix size, 256/0/0/192; slice thickness, 3 mm), T2-weighted fast spin-echo (2000/80.6; matrix size, 304/0/0/243; slice thickness, 3 mm) sagittal sequences of the lumbosacral spine were performed. The T2-weighted fast spin-echo (repetition time msec/echo time msec, 5095/111.8; matrix size, 288/0/0/184; slice thickness, 3mm) was performed in the axial plane.

Image analysis

Image evaluation was performed with syngo.via, version VB60A_HF02 (Siemens Healthineers, Erlangen, Germany). Initially, to establish the reference standard, two medical council-certified radiologists, blinded to the clinical and CT information, evaluated the MRI scans in consensus, to detect the type and presence of disc herniation (according to the lumbar disc pathologic classification of the North American Spine Society version 2.0),12,13 and the presence of lumbar disc herniation related spinal nerve root impingement. Lumbar disc herniation is defined as a focal displacement (< 25% of the disc circumference) of disc material beyond the limits of the intervertebral disc space. Lumbar disc herniation was classified as protrusion (distance between the edges of the disc herniation is less than the distance between the edges of the base), extrusion (distance between the edges of the herniated disc material is greater than the distance at the base in at least one plane), or sequestration (displaced disc material has lost continuity with the parent disc) by each reader.3,13 The base is defined as the width of disc material at the outer margin of the disc space of origin, where disc material displaced beyond the disc space is continuous with disc material within the disc space.3,13

Bulging lumbar disc is generalised extension (> 25% of the disc circumference) of disc tissue beyond the edges of the ring apophyses and considered as non-herniated discs according to the lumbar disc pathologic classification of the North American Spine Society.13

After establishing the reference standard, four radiologists experienced in musculoskeletal imaging and blinded to the MRI results and clinical information, were tasked to independently assess the DECT and standard CT images. Initially, grayscale standard CT series were presented to the readers in random order, to assess and record the presence and type of lumbar disc herniation and spinal nerve root impingement on a per-disc basis and on a per-patient basis. After a 6-8-week interval, to avoid potential recall bias, readers were presented with DECT images in a random order and tasked to independently evaluate the colour-coded ED reconstructions without having access to the standard CT data. Each reader was allowed to freely adjust the window settings and scroll through the entire CT series. The five-point Likert scales were used to assess image quality and diagnostic confidence across all CT series.5

Statistical analysis

Microsoft Excel (Redmond, Washington, United States), IBM SPSS (Armonk, New York, United States), MedCalc Software Ltd. (Ostend, Belgium). Data were entered in an Excel spreadsheet. Statistical analysis was performed using SPSS (Statistical Package for Social Sciences) version 20 (IBM SPASS statistics [IBM corp. released 2011]), MedCalc Software Ltd (Diagnostic test evaluation calculator, Version 22.023). Descriptive statistics of the variables was calculated through means and standard deviations for quantitative variables, frequency and proportions for qualitative variables. Chi-square test was applied to find the association of qualitative variables. The ROC curve was used to find the cut-off values, sensitivity and specificity of ED dual energy CT to predict lumbar disc herniation. A p < 0.05 was considered to indicate statistical significance. The standard t-test was applied to determine statistical significance of quantitative data. On a per-disc and per-patient basis, sensitivity, specificity, positive predictive values (PPVs), negative predictive values (NPVs) and accuracy values were computed. Clustering of intervertebral discs per patient following the method described by Genders et al.1433

Inter-reader agreement was evaluated by computing weighted Fleiss k. Kappa results were qualitatively stratified by score κ = 0.81-1.00, almost perfect agreement; κ = 0.61-0.80, substantial agreement; κ = 0.41-0.60, moderate agreement; κ = 0.21-0.40, fair agreement; and κ < 0.20, slight agreement.15

Ethical considerations

This retrospective study was approved by the Institutional Ethics Committee, Mysore medical college and Research Institute and associated hospitals. Ethical committee clearance was obtained on 18 January 2024. Patient consent for individual cases was waived as all studies were retrospectively collected from the institutional Picture Archiving and Communication System (PACS) and studies were anonymised prior to review by readers.16

Results

A total of 417 lumbar intervertebral discs (median per patient, six) in 72 patients (mean age, 49.7 years; range, 38-69 years) were included. A total of 39 males (54.2%; mean age, 49.8 years; range, 38-69 years) and 33 females (45.8%; mean age, 49.5 years; range, 39-66 years) were included. MRI revealed 154 lumbar herniated discs (36.9% of all intervertebral discs) and 96 instances of spinal nerve root impingement. There were 130 protrusions (31.1%), 19 extrusions (4.6%) and three sequestrations (1.2%). The mean examination interval between dual energy CT and MRI was 3 days (range, 0-5 days).

Diagnostic accuracy per intervertebral disc

Colour-coded ED reconstructions showed higher overall sensitivity, specificity, PPV, NPV and accuracy for the detection of lumbar disc herniation compared with standard CT, taking clustering into account.3Table 1). Inter reader agreement was almost perfect for ED images (k = 0.99) and standard CT (k = 0.90, p < 0.0001).

Table 1

Statistical analysis revealed higher overall sensitivity, specificity, PPV, NPV and accuracy for the detection of lumbar disc protrusion by using ED reconstructions compared with standard CT, taking clustering into account, with statistically significant correlations for sensitivity, NPV and accuracy (Table 2) (Figure 2). Inter reader agreement was almost perfect for ED images (k = 0.99) and for standard CT (k = 0.87, p < 0.0001).

Figure 2

Table 2

For the detection of spinal nerve root impingement, higher overall sensitivity, specificity, PPV, NPV and accuracy were noticed when comparing DECT ED reconstructions with standard CT, taking clustering into account (Table 3) (Figure 3 and Figure 4). The p-values were < 0.05 for sensitivity, NPV and accuracy for all readers. Inter reader agreement was almost perfect for ED images (k = 1) and substantial for standard CT (k = 0.79).

Table 3

Diagnostic accuracy per patient

The analysis per patient of colour-coded ED reconstructions for the detection of lumbar disc protrusion compared with standard grayscale CT images showed higher overall sensitivity, specificity, PPV, NPV and accuracy, with p < 0.05 for sensitivity, NPV and accuracy. For the detection of spinal nerve root impingement, higher overall sensitivity, specificity, PPV, NPV and accuracy were noted with colour-coded ED reconstructions compared to standard CT (Table 4). The data for sensitivity, NPV and accuracy were statistically significant. Inter reader agreement for ED reconstructions and for standard CT images was almost perfect and substantial for the detection of lumbar disc protrusion (k = 1 vs. 0.71), lumbar disc extrusion (k = 0.93 vs. 0.73), lumbar disc sequestration (k = 0.88 vs. 0.65), and spinal nerve root impingement (k = 1 vs. 0.79). The p-values for all comparisons were < 0.0001.

Table 4

Diagnostic confidence

The diagnostic confidence for lumbar disc herniation was very high for MRI (mean ~ 4.9), very high for DECT colour-coded ED reconstructions (mean ~ 4.8), and low for standard CT images (mean ~ 2.9). Inter reader agreement was good for ED images (k = 0.88), and for standard CT (k = 0.64).

Discussion

The findings in this study indicated that colour-coded ED reconstructions were more accurate in diagnosing lumbar disc herniation, protrusion and spinal nerve root impingement than standard CT. Colour-coded ED reconstructions had substantially higher overall sensitivity than standard CT for demonstrating lumbar disc herniation, protrusion, extrusion, sequestration and nerve impingement. Colour-coded ED reconstructions showed high (≥ 90%) overall specificity, PPV, NPV and accuracy for the detection of lumbar disc herniation, protrusion, extrusion, sequestration and nerve root impingement. Higher values were observed for ED reconstruction in all categories in comparison with standard grayscale CT. In addition, colour-coded ED reconstructions had a higher inter-reader agreement for the detection of lumbar disc herniation and spinal nerve root impingement compared to standard CT.

When MRI is not available or may be contraindicated, dual-energy CT could be an excellent alternative imaging modality, as supported by the high diagnostic accuracy of ED reconstructions for the diagnosis of lumbar disc herniation and nerve root impingement in this study. This study results were consistent with a previous study by Shim et al. on cervical disc herniations, which showed a higher sensitivity (94% vs. 76%) and accuracy (93% vs. 80%), respectively, for colour-coded ED reconstructions compared to standard CT.12

Colour overlay in ED reconstructions created excellent contrast to differentiate intervertebral discs from bones and spinal canal contents. Consequently, readers were more accurate with the colour overlay ED maps than standard CT in detecting small herniations. A previous study by Shim et al. showed that colour-coded ED maps provided higher noise suppression and increased smoothness resulting in higher subjective image quality than VNCa images.12

This study had several limitations. Firstly, only 72 patients were included because of the retrospective single-centre study design and a 1-week examination delay between dual-energy CT and MRI. Secondly, this study used MRI as the reference standard for the diagnosis of lumbar disc herniation. Earlier studies considered surgery as the standard of reference while assessing the diagnostic accuracy of standard CT for lumbar spine diseases,517,18 Forristall et al. showed that MRI was 90.3% accurate in the evaluation of lumbar disc herniation, compared to surgical findings.192021

Implications and recommendations

This study demonstrates the value of DECT as a substitute imaging modality for the detection of degenerative spinal disease in situations where MRI is either not available or contraindicated. However, multicentre research studies with higher sample sizes are indicated for further validation.

Conclusion

This research demonstrated that compared to standard CT, the colour-coded DECT ED reconstruction technique produced significantly better diagnostic accuracy for the identification of lumbar disc herniation and spinal nerve root impingement when using MRI as the reference standard. Similar diagnostic confidence and image quality were noticed for ED and MR images. Therefore, colour-coded DECT ED reconstruction can offer an excellent alternative when MRI is unavailable or contraindicated.

Competing interests

The authors declare that they have no financial or personal relationships that may have inappropriately influenced them in writing this article.

Authors' contributions

U.K.B., V.M. and Y.N. contributed to the conceived idea and study design. All authors U.K.B., S.B., V.M. and Y.N. contributed to data collection, data analysis, data interpretation and creation of the article.

Funding information

This research received no specific grant from any funding agency in the public, commercial, or not-for-profit sectors.

Data availability

The data that support the findings of this study are available from the corresponding author, S.B., upon request.

Disclaimer

The views and opinions expressed in this article are those of the authors and are the product of professional research. They do not necessarily reflect the official policy or position of any affiliated institution, funder, agency or that of the publisher. The authors are responsible for this article's results, findings and content.

Acknowledgements

References

  • 1. Shinohara Y, Sasaki F, Ohmura T, Itoh T, Endo T, Kinoshita T. Evaluation of lumbar intervertebral disc degeneration using dual energy CT virtual non-calcium imaging. Eur J Radiol. 2020;124:108817. https://doi.org/10.1016/j.ejrad.2020.108817
    » https://doi.org/10.1016/j.ejrad.2020.108817
  • 2. Dydyk AM, Ngnitewe Massa R, Mesfin FB. Disc herniation [homepage on the Internet]. [updated 2023 Jan 16]. Treasure Island, FL: StatPearls Publishing; 2023 [cited 2024 Aug 02]. Available from: https://www.ncbi.nlm.nih.gov/books/NBK441822
    » https://www.ncbi.nlm.nih.gov/books/NBK441822
  • 3. Booz C, Nöske J, Martin SS, et al. Virtual noncalcium dual-energy CT: Detection of Lumbar Disc Herniation in comparison with standard gray-scale CT. Radiology. 2019;290(2):446-455. https://doi.org/10.1148/radiol.2018181286
    » https://doi.org/10.1148/radiol.2018181286
  • 4. Koch V, Yel I, Grünewald LD, et al. Assessment of Thoracic Disc Herniation by using virtual noncalcium dual-energy CT in comparison with standard grayscale CT. Eur Radiol. 2021;31(12):9221-9231. https://doi.org/10.1007/s00330-021-07989-5
    » https://doi.org/10.1007/s00330-021-07989-5
  • 5. Notohamiprodjo S, Stahl R, Braunagel M, et al. Diagnostic accuracy of contemporary multidetector computed tomography (MDCT) for the detection of lumbar disc herniation. Eur Radiol. 2017;27(8):3443-3451. https://doi.org/10.1007/s00330-016-4686-7
    » https://doi.org/10.1007/s00330-016-4686-7
  • 6. Lee SM, Choo HJ, Lee SJ et al. Cervical spine CT using spectral shaping: can it be a solution to overcome artifacts in the lower cervical spinal region? Korean J Radiol. 2019;20(3):469-478. https://doi.org/10.3348/kjr.2018.0517
    » https://doi.org/10.3348/kjr.2018.0517
  • 7. Yi JS, Cha JG, Han JK, Kim HJ. Imaging of herniated discs of the cervical spine: Inter-modality differences between 64-slice multidetector CT and 1.5-T MRI. Korean J Radiol. 2015;16(4):881-888. https://doi.org/10.3348/kjr.2015.16.4.881
    » https://doi.org/10.3348/kjr.2015.16.4.881
  • 8. Abdellatif W, Nugent JP, Alballa F, et al. Dual energy computed tomography collagen material decomposition for detection of lumbar spine disc extrusion and sequestration: A comparative study with Greyscale Computed Tomography. Can Assoc Radiol Jo. 2022;74(1):110-118. https://doi.org/10.1177/08465371221118886
    » https://doi.org/10.1177/08465371221118886
  • 9. Pache G, Krauss B, Strohm P, et al. Dual-energy CT virtual noncalcium technique: Detecting posttraumatic bone marrow lesions-Feasibility study. Radiology. 2010;256(2):617-624. https://doi.org/10.1148/radiol.10091230
    » https://doi.org/10.1148/radiol.10091230
  • 10. Glazebrook KN, Brewerton LJ, Leng S, et al. Case-control study to estimate the performance of dual-energy computed tomography for anterior cruciate ligament tears in patients with history of knee trauma. Skeletal Radiol. 2013;43(3):297-305. https://doi.org/10.1007/s00256-013-1784-3
    » https://doi.org/10.1007/s00256-013-1784-3
  • 11. Deng K, Sun C, Liu C, Ma R. Initial experience with visualizing hand and foot tendons by dual-energy computed tomography. Clin Imaging. 2009;33(5):384-389. https://doi.org/10.1016/j.clinimag.2008.12.007
    » https://doi.org/10.1016/j.clinimag.2008.12.007
  • 12. Shim E, Kim BH, Kang WY, et al. Diagnostic performance of electron-density dual-energy CT in detection of cervical disc herniation in comparison with standard gray-scale CT and virtual non-calcium images. Eur Radiol. 2022;32(4):2209-2220. https://doi.org/10.1007/s00330-021-08374-y
    » https://doi.org/10.1007/s00330-021-08374-y
  • 13. Fardon DF, Williams AL, Dohring EJ, Murtagh FR, Gabriel Rothman SL, Sze GK. Lumbar disc nomenclature: version 2.0: recommendations of the combined task forces of the North American Spine Society, the American Society of Spine Radiology, and the American Society of Neuroradiology. Spine J. 2014;14(11):25252545. https://doi.org/10.1016/j.spinee.2014.04.022
    » https://doi.org/10.1016/j.spinee.2014.04.022
  • 14. Genders TS, Spronk S, Stijnen T, Steyerberg EW, Lesaffre E, Hunink MG. Methods for calculating sensitivity and specificity of clustered data: A tutorial. Radiology. 2012;265(3):910-916. https://doi.org/10.1148/radiol.12120509
    » https://doi.org/10.1148/radiol.12120509
  • 15. Hazra A, Gogtay N. Biostatistics series module 7: The Statistics of Diagnostic tests. Indian J Dermatol. 2017;62(1):18-24. https://doi.org/10.4103/0019-5154.198047
    » https://doi.org/10.4103/0019-5154.198047
  • 16. Singh R, Wilson MP, Manolea F, et al. Diagnostic accuracy and inter-reader reliability of the MRI Liver Imaging Reporting and Data System (version 2018) risk stratification and management system. S Afr J Radiol. 2022;26(1):2386. https://doi.org/10.4102/sajr.v26i1.2386
    » https://doi.org/10.4102/sajr.v26i1.2386
  • 17. Wassenaar M, Van Rijn RM, Van Tulder MW, et al. Magnetic resonance imaging for diagnosing lumbar spinal pathology in adult patients with low back pain or sciatica: A diagnostic systematic review. Eur Spine J. 2012;21(2):220-227. https://doi.org/10.1007/s00586-011-2019-8
    » https://doi.org/10.1007/s00586-011-2019-8
  • 18. Alsaleh K, Ho D, Rosas-Arellano MP, Stewart TC, Gurr KR, Bailey CS. Radio graphic assessment of degenerative lumbar spinal stenosis: Is MRI superior to CT? Eur Spine J. 2017;26(2):362-367. https://doi.org/10.1007/s00586-016-4724-9
    » https://doi.org/10.1007/s00586-016-4724-9
  • 19. Forristall Ronald M, Marsh Henry O, Pay Norman T. Magnetic resonance imaging and contrast CT of the lumbar spine: Comparison of diagnostic methods and correlation with surgical findings. Spine. 1988;13(9):1049-1054. https://doi.org/10.1097/00007632-198809000-00013
    » https://doi.org/10.1097/00007632-198809000-00013
  • 20. Jackson Roger P, Cain James E. Jr., Jacobs Rae R, Cooper Barry R, McManus Gerald E. The neuroradiographic diagnosis of lumbar herniated nucleus pulposus: II: A comparison of computed tomography (CT), myelography, CT-myelography, and magnetic resonance imaging. Spine. 1989;14(12):1362-1367. https://doi.org/10.1097/00007632-198912000-00013
    » https://doi.org/10.1097/00007632-198912000-00013
  • 21. Kim J-H, Van Rijn RM, Van Tulder MW, et al. Diagnostic accuracy of diagnostic imaging for lumbar disc herniation in adults with low back pain or sciatica is unknown; A systematic review. Chiropractic Manual Ther. 2018;26(1):37. https://doi.org/10.1186/s12998-018-0207-x
    » https://doi.org/10.1186/s12998-018-0207-x

Correspondence:
Sushmita Balol

Received: 07 Aug. 2024
Accepted: 17 Sept. 2024
Published: 18 Nov. 2024

Correspondence

sushmitabalol@gmail.com

Publication Dates

  • Publication in this collection
    03 Feb 2025
  • Date of issue

History

  • Received
    07 Aug 2024
  • Accepted
    17 Sept 2024
location_on
Radiological Society of South Africa AOSIS Publishing, Postnet Suite #110, Private Bag X19, Durbanville, Cape Town, Western Cape Province, ZA, 7551, Tel: +27 21 975 2602, Tel: 086 1000 381 - E-mail: publishing@aosis.co.za
rss_feed Acompañe los números de esta revista en su lector de RSS
Ir para arriba