Open-access Answer to quiz case: Temporal bone imaging

Abstract

Computed tomographic scanning of the petrous bone and magnetic resonance imaging sequences of the inner ear and cerebellopontine angle of a deaf patient were performed to find an explanation for his deafness, and to establish whether he would be a good candidate for cochlear implantation. The imaging features were considered pathognomonic for incomplete partition type III (IP type III). Further management and discussion of this deafness subtype are detailed.


Introduction

The best responses received for this temporal bone imaging quiz case were from Dr T.E. Buthelezi and Dr Herman van Vuuren. Congratulations to them.

Background

Computed tomographic (CT) scanning of the petrous bone and magnetic resonance imaging (MRI) sequences of the inner ear and cerebellopontine angle of a deaf patient were performed to find an explanation for his deafness, and to establish whether he would be a good candidate for cochlear implantation.

Diagnosis

The CT images of the temporal bone showed a normal aspect of the mastoid, tympanic membrane middle ear cavity and ossicular chain bilaterally (not shown in detail in Figure 1). The abnormalities can be seen in the inner ear structures (Figure 1). The images show bilateral bulbous dilatation of the internal auditory canal (IAC). The bone plates at the fundus of the IAC, which separate them from the cochlear basal turn, are absent. The modiolus is deficient, with a present interscalar septum, giving the dysplastic cochleas a corkscrew appearance. This corkscrew appearance is also apparent on 3D T2 MR-imaging (Figure 2). Also visible is the minor dilatation of the labyrinthine segment of the facial canal on the right, and of the tympanic segment of the facial canal on the left (Figure 1). These specific imaging features are considered pathognomonic for incomplete partition type III (IP type III).

Figure 1

The patient underwent cochlear implantation on the right side. Insertion of the electrode of the cochlear implant was troublesome but complete. Upon cochleostomy, expected perilymph gushing owing to a fistulous connection between the IAC and the cochlea occurred. The gushing was controlled and properly sealed. Perioperative impedance measurements of the electrodes and brainstem responses showed good measurements for apical and basal electrode contacts, but not for those in between. Postoperative imaging confirmed an unusual position of the electrode, with parts of it bulging into the IAC (Figure 3). Apparently, the tip of the electrode had been blocked in the upper basal turn during insertion, causing part of the middle portion of the array to bulge into the internal auditory meatus, when the surgeon tried to achieve full insertion. Despite this unfavourable electrode position, the patient recovered well from surgery and, with an adequate fitting, postoperative performance of this prelingually deaf adult was acceptable (up to 55% of phonemes correct on a monosyllabic word test on a CD in quiet), with the patient able to hear sufficiently to participate normally in conversation.

Discussion

The combination of clinical and imaging findings in this patient are characteristic of IP type-III, which is often also referred to as X-linked deafness type 2 (DFNX2).1,2,3,4,5,6,7,8,910

The simultaneous occurrence of bilateral bulbous dilatation of the IAC, absence of the lamina cribrosa separating the IAC from the cochlear basal turn, absent modioli and dilatation of the first two segments of the facial canal should make one aware of the diagnosis of IP type-III. Glasscock, using coronal section polytomography,1112,13145151041699

The absence of the bony partition between the IAC and cochlea allows a direct fistulous connection between the subarachnoid space and the perilymph in the labyrinth. Intracranial pressure is transmitted to the perilymphatic spaces (scala vestibuli and scala tympani), leading to an increased pressure impinging on the cochlear duct17181719

DFNX2 is caused by a mutation in or around the POU3F4 gene on chromosome Xq21.2021,22232123244,181,92498

With normal outer diameters, but disorganised internal architecture of the cochlea, IP type III can be treated successfully with cochlear implantation when sensorineural hearing loss is profound.9259,10

In summary: IP type III is a rare cause of mixed conductive and sensorineural hearing loss, but the radiologist may play a crucial role in both diagnosis and treatment of the disorder.

Competing interests

The authors declare that they have no financial or personal relationships which may have inappropriately influenced them in writing this article.

Authors' contributions

E.B.A. (Leiden University Medical Center; Medical Center Haaglanden) drafted the manuscript. J.F. (Leiden University Medical Center) and B.V. (Leiden University Medical Center; Radboud University Nijmegen Medical Center) critically revised it for important intellectual content.

References

  • 1.Altay H, Savas R, Ogut F, Kirazli T, Alper H. CT and MRI findings in X-linked progressive deafness. Diagn Interv Radiol. 2008;14:117-119. PMID: 18814129.
  • 2. Gong WX, Gong RZ, Zhao B. HRCT and MRI findings in X-linked non-syndromic deafness patients with a POU3F4 mutation. Int J Pediatr Otorhinolaryngol. 2014;78: 1756-1762. PMID: 25175280, http://dx.doi.org/10.1016/j.ijporl.2014.08.013
    » http://dx.doi.org/10.1016/j.ijporl.2014.08.013
  • 3. Kumar G, Castillo M, Buchman CA. X-linked stapes gusher: CT findings in one patient. AJNR Am J Neuroradiol. 2003;24:1130-1132. PMID: 12812938.
  • 4. Phelps PD, Reardon W, Pembrey M, Bellman S, Luxom L. X-linked deafness, stapes gushers and a distinctive defect of the inner ear. Neuroradiology. 1991;33:326-330. PMID: 1922747, http://dx.doi.org/10.1007/BF00587816
    » http://dx.doi.org/10.1007/BF00587816
  • 5. Talbot JM, Wilson DF. Computed tomographic diagnosis of X-linked congenital mixed deafness, fixation of the stapedial footplate, and perilymphatic gusher. Am J Otol. 1994;15:177-182. PMID: 8172298.
  • 6. Tang A, Parnes LS. X-linked progressive mixed hearing loss: Computed tomography findings. Ann Otol Rhinol Laryngol. 1994;103:655-657. PMID: 8060062, http://dx.doi.org/10.1177/000348949410300814
    » http://dx.doi.org/10.1177/000348949410300814
  • 7. Chee NW, Suhailee S, Goh J. Clinics in diagnostic imaging (111): X-linked congenital mixed deafness syndrome. Singapore Med J. 2006;47:822-824. PMID: 16924369.
  • 8. Alizadeh H, Nasri F, Mehdizadeh M, Jamsa S. Computed tomography findings of a patient with severe dysplasia of the inner ear and recurrent meningitis: A case report of gusher ear in a five-year old boy. Iran J Radiol. 2014;11:e4168. PMID: 25763081, http://dx.doi.org/10.5812/iranjradiol.4168
    » http://dx.doi.org/10.5812/iranjradiol.4168
  • 9. Incesulu A, Adapinar B, Kecik C. Cochlear implantation in cases with incomplete partition type III (X-linked anomaly). Eur Arch Otorhinolaryngol. 2008;265:1425-1430. PMID: 18305951, http://dx.doi.org/10.1007/s00405-008-0614-z
    » http://dx.doi.org/10.1007/s00405-008-0614-z
  • 10. Naito Y. Pediatric ear diseases. Basel: Karger; 2013.
  • 11. Glasscock ME, III. The stapes gusher. Arch Otolaryngol. 1973;98:82-91. PMID: 4723769, http://dx.doi.org/10.1001/archotol.1973.00780020088004
    » http://dx.doi.org/10.1001/archotol.1973.00780020088004
  • 12. Bento RF, Miniti A. X-linked mixed hearing loss: Four case studies. Laryngoscope. 1985;95:462-468. PMID: 4039021, http://dx.doi.org/10.1288/00005537-198504000-00017
    » http://dx.doi.org/10.1288/00005537-198504000-00017
  • 13. Jensen J, Terkildsen K, Thomsen KA. Inner ear malformations with oto-liquorrhea. Tomographic findings in three cases with a mixed hearing impairment. Arch Otorhinolaryngol. 1977;214:271-282. PMID: 576408, http://dx.doi.org/10.1007/BF00458322
    » http://dx.doi.org/10.1007/BF00458322
  • 14. Cremers CW, Hombergen GC, Wentges RT. Perilymphatic gusher and stapes surgery. A predictable complication? Clin Otolaryngol Allied Sci. 1983;8:235-240. PMID: 6652936, http://dx.doi.org/10.1111/j.1365-2273.1983.tb01434.x
    » http://dx.doi.org/10.1111/j.1365-2273.1983.tb01434.x
  • 15. Sennaroglu L. Cochlear implantation in inner ear malformations-A review article. Cochlear Implants Int. 2010;11:4-41. PMID: 19358145, http://dx.doi.org/10.1002/cii.416
    » http://dx.doi.org/10.1002/cii.416
  • 16.Sennaroglu L, Sarac S, Ergin T. Surgical results of cochlear implantation in malformed cochlea. Otol Neurotol. 2006;27:615-623. PMID: 16788416, http://dx.doi.org/10.1097/01.mao.0000224090.94882.b4
    » http://dx.doi.org/10.1097/01.mao.0000224090.94882.b4
  • 17. Swartz JD, Loevner LA. Imaging of the temporal bone. New York: Thieme; 2009.
  • 18. Van De Water T, Staecker H. Otolaryngology: Basic science and review. New York: Thieme; 2006.
  • 19. Nance WE, Setleff R, McLeod A, Sweeney A, Cooper C, McConnell F. X-linked mixed deafness with congenital fixation of the stapedial footplate and perilymphatic gusher. Birth Defects Orig Artic Ser. 1971;7:64-69. PMID: 5173351.
  • 20. de Kok YJ, van der Maarel SM, Bitner-Glindzicz M, et al. Association between X-linked mixed deafness and mutations in the POU domain gene POU3F4. Science. 1995;267:685-688. PMID: 7839145, http://dx.doi.org/10.1126/science.7839145
    » http://dx.doi.org/10.1126/science.7839145
  • 21. Rost S, Bach E, Neuner C, et al. Novel form of X-linked nonsyndromic hearing loss with cochlear malformation caused by a mutation in the type IV collagen gene COL4A6. Eur J Hum Genet. 2014;22:208-215. PMID: 23714752, http://dx.doi.org/10.1038/ejhg.2013.108
    » http://dx.doi.org/10.1038/ejhg.2013.108
  • 22. Song MH, Lee KY, Choi JY, Bok J, Kim UK. Nonsyndromic X-linked hearing loss. Front Biosci (Elite Ed). 2012;4:924-933. PMID: 22201925.
  • 23. Petersen MB, Wang Q, Willems PJ. Sex-linked deafness. Clin Genet. 2008;73: 14-23. PMID: 18005182.
  • 24. Papadaki E, Prassopoulos P, Bizakis J, Karampekios S, Papadakis H, Gourtsoyiannis N. X-linked deafness with stapes gusher in females. Eur J Radiol. 1998;29:71-75. PMID: 9934561, http://dx.doi.org/10.1016/S0720-048X(98)00027-8
    » http://dx.doi.org/10.1016/S0720-048X(98)00027-8
  • 25. Phelps PD. Cochlear implants for congenital deformities. J Laryngol Otol. 1992;106: 967-970. PMID: 1479272, http://dx.doi.org/10.1017/S0022215100121486
    » http://dx.doi.org/10.1017/S0022215100121486

Correspondence:
Enrico Arkink
PO Box 9600, 2300 RC Leiden
The Netherlands
Email: e.b.arkink@lumc.nl

Received: 26 Aug. 2015
Accepted: 28 Aug. 2015
Published: 21 Oct. 2015

Correspondence

Publication Dates

  • Publication in this collection
    18 Feb 2016
  • Date of issue

History

  • Received
    26 Aug 2015
  • Accepted
    28 Aug 2015
location_on
Radiological Society of South Africa AOSIS Publishing, Postnet Suite #110, Private Bag X19, Durbanville, Cape Town, Western Cape Province, ZA, 7551, Tel: +27 21 975 2602, Tel: 086 1000 381 - E-mail: publishing@aosis.co.za
rss_feed Stay informed of issues for this journal through your RSS reader
Go to top