Abstract
BACKGROUND: The contrast-enhanced T2-FLAIR (CE-T2-FLAIR) sequence on MRI, through the suppression of CSF and vascular signals, can detect subtle meningeal enhancement in meningitis that may not be appreciable on the routinely used contrast-enhanced T1W (CE-T1W) sequence. OBJECTIVES: To assess CE-T2-FLAIR compared to CE-T1W in the diagnosis of meningitis, using CSF analysis as the gold standard, using both qualitative and quantitative approaches for assessment. METHOD: A retrospective study was conducted on 53 patients with clinically suspected meningitis referred for brain MRI. Twenty-seven patients, positive for meningitis on CSF analysis, were classified as the case group; the remaining patients were designated as controls. The pre-contrast, CE-T1W and CE-T2-FLAIR images were assessed and analysed, qualitatively for the detection of abnormal meningeal enhancement, and quantitatively by measuring single pixel signal intensities (SPSI) over the meninges and vessels. RESULTS: Contrast-enhanced T2-FLAIR demonstrated significantly higher sensitivity (92.59% vs. 57.69%), negative predictive value (92.59% vs. 70.27%) and diagnostic accuracy (94.34% vs. 78.85%) compared to CE-T1W. Additionally, CE-T2-FLAIR showed significantly greater meningeal SPSI and enhancement than CE-T1W. CONCLUSION: Contrast-enhanced T2-FLAIR is better at detecting abnormal meningeal enhancement in meningitis than CE-T1W, because of significantly greater signal intensity and enhancement of the meninges compared to vessels. CONTRIBUTION: This study reiterates the usefulness of CE-T2-FLAIR as an additional sequence for the detection of abnormal meningeal enhancement in cases of meningitis as confirmed both qualitatively and quantitatively.
meningitis; meninges; abnormal meningeal enhancement; contrast-enhanced T2-FLAIR; contrast-enhanced T1W; magnetic resonance imaging; single pixel signal intensity; central nervous system; retrospective study
Introduction
Meningitis is a disease characterised by inflammation of the meninges.12,3,45
Meningitis is a major global health issue with 2.51 million cases reported in 2019; the age-standardised incidence ranges from 29.6 to 42.5 per 100 000 cases (mean ~35.4 per 100 000 cases) and the mortality rate ranges from 2.8 to 3.9 (mean~ 3.3) per 100 000 cases globally. The incidence and mortality rate are much higher in the under-5 age group. Apart from the high mortality rates, it can also be associated with high morbidity, because of cognitive impairment, neurological deficits, epilepsy and other complications.1
Clinical features of meningitis include fever, headache, altered sensorium and neck rigidity. Meningitis is characterised by elevated CSF opening pressure and leukocyte count.267
Meningeal thickening that occurs in meningitis can be detected in only a few cases on pre-contrast MRI sequences. Abnormal meningeal enhancement (AME) is an important feature in detecting meningitis6,83,5,6,95,666,10
Many studies have documented the superiority of CE-T2-FLAIR over CE-T1W imaging in the detection of meningitis.6,8,10,11,12,136,10
Research methods and design
This retrospective study included all patients with clinically suspected meningitis who were referred for brain MRI to the Department of Radiodiagnosis at Mysore Medical College and Research Institute, over a 12-month period from 10 August 2023 to 09 August 2024. Patients who were positive for meningitis on CSF analysis were classified into the case group while those with negative results were placed in the control group. The CSF analysis results were obtained from hospital records.
Any patients for whom CE-T2-FLAIR and CE-T1W were not performed, or for whom CSF analysis results were unavailable, were excluded from the study. Additionally, patients with contraindications to MRI, allergies to gadolinium contrast agents, impaired renal function, recent trauma, neurosurgery, brain and spine neoplasms, acute or subacute infarcts, congenital or birth abnormalities of the brain, or those who received supplemental oxygen, intravenous gadolinium or iodinated contrast in the previous week were also excluded. The study selection flow chart is presented in Figure 1.
MRI protocol
Imaging was performed using a 1.5 Tesla (United Imaging, Jiading, Shanghai, China) uMR570 machine. All patients or guardians provided consent for brain MRI with contrast. The T1W sequence protocol was: time to repeat (TR): 16.77, time to echo (TE): 7.7, Slice thickness: 1, Slice gap: 1, Echo train length: 130, Echo number: 1, FOV: 232 × 256, TI:1100, Flip angle: 10, Acquisition matrix: 256 × 232, Pixel bandwidth: 160, Number of signal averages: 1 and Acquisition time: 3 min 54 s. Water excitation method of fat suppression was used. The T2-FLAIR sequence protocol was: TR: 6000, TE: 372, Slice gap: 0.7, Slice thickness: 0.7, Echo train length: 200, FOV: 232 × 256, TI: 1797, Flip angle: 54, Acquisition Matrix: 240 × 218, Pixel bandwidth: 500, Number of signal averages: 1 and Acquisition time: 4 min 5 s. Pre-contrast T1W and T2-FLAIR sequences were obtained. Contrast-enhanced T1-weighted and CE-T2-FLAIR sequences were obtained after the intravenous administration of gadolinium contrast agent (0.1 mmol/kg body weight of Gadobutrol). Contrast-enhanced T2-FLAIR was acquired after the CE-T1W sequence with a delay of nearly 4 min - 5 min.
Image analysis
The MR images were retrieved from the picture archiving and communication system (PACS) and were evaluated randomly by two radiologists, who were blinded to the CSF analysis results. The pre-contrast and post-contrast T1W and T2-FLAIR sequences were evaluated to detect any meningeal abnormality. Readers were free to adjust window settings and scroll through the entire stack of MRI data.
Qualitative assessment
The exam was considered positive if the radiologist detected any AME. On CE-T1W, AME was considered definite if it was thick, long or noted on greater than three contiguous images. It was deemed equivocal if seen on less than three contiguous images or if it was not separately distinguishable from vascular enhancement. On CE-T2-FLAIR, any enhancement along the subarachnoid spaces or cranial nerves was considered AME. Leptomeningeal enhancement was graded as follows: grade 0 (no enhancement), grade 1 (thin meningeal enhancement, along < 3 sulcal spaces, but no enhancement along the basal cisterns), grade 2 (thick meningeal enhancement, along >3 sulcal spaces, but no enhancement along the basal cisterns), and grade 3 (enhancement along the basal cisterns ± cortical sulci).6,10
Quantitative assessment
In cases with AME, single pixel signal intensities (SPSI) were obtained from the regions of interest (ROI), of size 1 mm26,10
Data analysis
The data collected were recorded and entered into the Microsoft Excel (Microsoft, Redmond, Washington, United States) master sheet. Data were tabulated and analysed using the Statistical Package for Social Sciences (SPSS) version 24 software (IBM Corporation, Armonk, New York, United States). Categorical data were presented as numbers and percentages. Qualitative variables were analysed using Pearson's Chi-square test and Fisher exact tests. Quantitative variables were presented using means and standard deviations (s.d.) and analysed using the student t test. A p-value < 0.05 was considered statistically significant. Sensitivity, specificity, positive predictive values (PPV), negative predictive values (NPV) and accuracy were calculated. All values of overall sensitivity, specificity, PPV, NPV and accuracy were expressed as means with 95% confidence intervals. For qualitative assessment, an inter-reader agreement was evaluated by computing weighted Cohen's κ (kappa). Kappa results were qualitatively stratified by score κ = 0.81 to 1.00, almost perfect agreement; κ = 0.61 to 0.80, substantial agreement; κ = 0.41 to 0.60, moderate agreement; κ = 0.21 to 0.40, fair agreement; and κ < 0.20, slight agreement.1415
Ethical considerations
This retrospective study was approved by the Institutional Ethics Committee of Mysore Medical College and Research Institute and Associated Hospitals, Mysore. Ethical committee clearance was obtained on 17 August 2024. Patient consent for individual cases was waived, as all data were retrospectively collected from the institutional PACS and anonymised prior to review by individual readers.
Results
A final total of 53 patients (29 females and 24 males), with clinically suspected meningitis, were included in the study. Twenty-seven patients who were CSF positive for meningitis were included in the case group; the rest of the patients were included in the control group. Table 1 includes the age and sex distribution in the sample.
Qualitative assessment
There was a significant difference in the qualitative assessment of meningeal abnormalities between CE-T1W and CE-T2-FLAIR (Figure 2, Figure 3 and Figure 4). In the case group, AME was found in a higher number of patients on CE-T2-FLAIR (25/27) than on CE-T1W (15/27). In the control group, there was one false positive AME on CE-T2-FLAIR, whereas no false positive AME was noted on CE-T1W. Reader 2 noted equivocal enhancement in two patients of the case group on CE-T1W (Figure 5).
Contrast-enhanced T2-FLAIR had a significantly higher sensitivity (92.59% vs. 57.69%) (p < 0.001), NPV (92.59% vs. 70.27%) (p < 0.001) and diagnostic accuracy (94.34% vs. 78.85%) compared to CE-T1W (p = 0.002) (combined reader 1 and reader 2). Contrast-enhanced T2-FLAIR and CE-T1W showed no significant difference in specificity (96.15% vs. 100%) (p = 0.298) and PPV (96.15% vs. 100%) (p = 0.374) (Table 2). The number of cases of AME as detected by each of the readers in CE-T1W and CE-T2-FLAIR have been represented in the bar graph (Figure 6).
The inter-reader agreement was almost perfect for both sequences. Cohen's kappa was higher for CE-T2-FLAIR (κ = 1.0) than CE-T1W (κ = 0.94). Image quality was nearly excellent for both pre-contrast and post-contrast T1W and T2-FLAIR sequences (mean score = 4.83). Diagnostic confidence for meningitis was higher for CE-T2-FLAIR (mean score = 4.83) than CE-T1W (mean score = 4.64).
Quantitative assessment
Quantitative assessment was performed on all patients with meningeal abnormalities by measuring the SPSI of the meninges and vessels. The meningeal and vascular SPSI and enhancement on CE-T1W and CE-T2-FLAIR have been represented in Table 3 (Figure 7 and Figure 8). On CE-T2-FLAIR, all patients displayed a meningeal SPSI and meningeal enhancement higher than vascular SPSI and vascular enhancement, respectively. On CE-T1W, all patients displayed a meningeal SPSI and meningeal enhancement lower than vascular SPSI and vascular enhancement, respectively.
The inter-reader agreement on CE-T2-FLAIR was excellent for meningeal SPSI (ICC = 0.98) and vascular SPSI (ICC = 0.97). The inter-reader agreement on CE-T1W was moderate for meningeal SPSI (ICC = 0.69) and good for vascular SPSI (ICC = 0.79).
Discussion
The current study reiterates that CE-T2-FLAIR is better at detecting AME than CE-T1W. Contrast-enhanced T2-FLAIR had a significantly higher sensitivity, NPV and diagnostic accuracy compared to CE-T1W in the detection of AME in meningitis. Contrast-enhanced T2-FLAIR was able to appreciate more cases of AME than CE-T1W, particularly of subtle grade 1 leptomeningeal enhancement and basal cisternal enhancement around the brainstem. This is because of the suppression of the vascular signal on CE-T2-FLAIR. Subtle meningeal enhancement on CE-T1W may be missed against the higher signal intensity of the vessels in the subarachnoid space. Contrast-enhanced T2-FLAIR showed slightly higher diagnostic confidence and inter-reader agreement than CE-T1W for qualitative assessment. There was a greater SPSI for enhancing meninges compared to vessels on CE-T2-FLAIR, while the SPSI for meninges was significantly lower than vessels on CE-T1W. Inter-reader agreement for quantitative assessment of meningeal enhancement was moderate for CE-T1W and excellent for CE-T2-FLAIR. Thus, it was easier to detect AME on CE-T2-FLAIR on the background of vessel signal suppression, compared to CE-T1W. However, CE-T2-FLAIR may also be associated with false positive meningeal enhancement in the posterior fossa and base of the brain. In this study, the ROI was manually placed for the measurement of SPSI on areas of AME and adjacent vessels. If no patient movement occurs between sequences, software can be used to simultaneously place the ROI at the same site in these sequences. In the study by Azad et al.,10
The role of imaging in meningitis is to confirm suspected meningitis, rule out raised intracranial pressure, assess complications and evaluate for a possible aetiology or source of infection.582,5,94,564
Pia-arachnoid or leptomeningeal enhancement appears as enhancement along the surface of the brain, extending into the subarachnoid space of sulci and cisterns. It usually occurs because of infectious meningitis but can be seen in other conditions such as inflammatory diseases, vasculitis, meningeal carcinomatosis and stroke. Dura-arachnoid or pachymeningeal enhancement, which appears as curvilinear enhancement deep to the inner table of the skull, is rarely observed in infectious meningitis. Instead, it is more commonly associated with other conditions such as intracranial hypotension, granulomatous or inflammatory diseases (e.g., sarcoidosis, infection, IgG4-related pachymeningitis), autoimmune diseases, postoperative changes, meningioma, secondary lymphoma, metastases or it may be idiopathic. Additionally, combined leptomeningeal and pachymeningeal enhancement can also be observed. Other causes of meningeal enhancement include subarachnoid haemorrhage (SAH), drug-induced, vaccines, collagen vascular diseases and chemical meningitis.2,3,4,9,5,16
The possible aetiology of AME can be determined based on the type of AME (leptomeningeal or pachymeningeal), grade of AME (higher grade in tubercular, intermediate in bacterial and lower grade in viral aetiology),1055,172,9,175,18
The use of T1W sequences is associated with excessive vascular enhancement, inflow effects and flat images. The FLAIR sequence allows for the recovery of the brain magnetisation, suppresses CSF signal intensity, helps to reduce CSF artefacts and obtains very high T2 weighting with the use of long echo times. It suppresses the signal from slow-flowing vessels because of the lack of inflow enhancement phenomenon.6,106,8,10,11,12,1313,198,191913,20,21
Post-processing software can create subtraction images by subtracting the signal intensity of pre-contrast and post-contrast sequences. These subtraction images of pre-contrast and post-contrast FLAIR show higher sensitivity and NPV for detecting leptomeningeal enhancement compared to CE-T1W or CE-T2-FLAIR sequences.202120
A new imaging technique for post-contrast study is T1W with MT which uses an off-resonance saturation pulse before the 90° pulse. A study by Azad et al. found that it had lower sensitivity, specificity, PPV, NPV and accuracy than CE-T2-FLAIR.1010,18112223
The limitations of T2-FLAIR sequence include artefactual hyperintense sulci in children even on pre-contrast FLAIR because of longer effective TE and CSF flow artefacts, artefactual hyperintensity in the posterior fossa, FLAIR hyperintensity in the subarachnoid space in conditions other than meningitis such as SAH, stroke, carcinomatosis, melanosis, fat-containing tumours and in patients who have received supplemental oxygen, gadolinium or iodinated contrast in the previous week or some sedatives.5,6,9,1024112524
This study has a few limitations such as the lack of correlation with the clinical severity of meningitis (Glasgow Coma Scale scores) and aetiological agent of meningitis, because of the retrospective nature of the study. For acquiring SPSI, the ROI was manually placed in nearly the same position on pre-contrast and post-contrast sequences because there was a slight change in patient position between sequences in a few patients, which was unavoidable in a retrospective study. The subtraction technique could not be used because of minor patient movement between sequences. Patient movements between sequences could be avoided in a prospective study.
This study shows that early meningitis which shows only subtle meningeal enhancement may be detected using CE-T2-FLAIR and missed if only CE-T1W sequence is used. The better diagnostic performance of CE-T2-FLAIR has been quantitatively confirmed in this study. Thus CE-T2-FLAIR should be routinely considered for use in all clinically suspected cases of meningitis. Contrast-enhanced T1-weighted images are routinely acquired immediately after the administration of contrast and can be followed by the CE-T2-FLAIR sequence, which is performed 4 min to 5 min after the start of the CE-T1W sequence, as was performed in this study. However, it must be interpreted in the appropriate clinical context, as non-infectious conditions may also result in AME.
Conclusion
Contrast-enhanced T2-FLAIR is more effective at detecting AME in meningitis compared to CE-T1W, particularly in cases with subtle enhancement. This is because of the significantly greater signal intensity and enhancement of the meninges relative to the vessels, as quantitatively assessed using SPSI in this study.
Competing interests
The authors declare that they have no financial or personal relationships that may have inappropriately influenced them in writing this article.
Authors' contributions
S.P. contributed to the study design, data collection and article creation. V.M. and S.B. were involved in the conceptualisation of the initial idea, as well as the study design, data collection, analysis, interpretation and article preparation. Y.N.M.B. assisted with the study design, data collection and article creation.
Funding information
This research received no specific grant from any funding agency in the public, commercial or not-for-profit sectors.
Data availability
The data that support the findings of this study are available from the corresponding author, V.M., upon request.
Disclaimer
The views and opinions expressed in this article are those of the authors and are the product of professional research. The article does not necessarily reflect the official policy or position of any affiliated institution, funder, agency or that of the publisher. The authors are responsible for this article's results, findings and content.
Acknowledgements
References
-
1.Wunrow HY, Bender RG, Vongpradith A, et al. Global, regional, and national burden of meningitis and its aetiologies, 1990-2019: A systematic analysis for the global burden of disease study 2019. Lancet Neurol. 2023;22(8):685-711. https://doi.org/10.1016/s1474-4422(23)00195-3
» https://doi.org/10.1016/s1474-4422(23)00195-3 -
2.Kurokawa R, Kurokawa M, Isshiki S, et al. Dural and leptomeningeal diseases: Anatomy, causes, and neuroimaging findings. RadioGraphics. 2023;43(9):1-7. https://doi.org/10.1148/rg.230039
» https://doi.org/10.1148/rg.230039 -
3.Quint DJ, Petter Eldevik O, Cohen JK. Magnetic resonance imaging of normal meningeal enhancement at 1.5T. Acad Radiol. 1996;3(6):463-468. https://doi.org/10.1016/s1076-6332(96)80002-x
» https://doi.org/10.1016/s1076-6332(96)80002-x -
4.Smirniotopoulos JG, Murphy FM, Rushing EJ, Rees JH, Schroeder JW. Patterns of contrast enhancement in the brain and Meninges. RadioGraphics. 2007;27(2):525-551. https://doi.org/10.1148/rg.272065155
» https://doi.org/10.1148/rg.272065155 -
5.Mohan S, Jain KK, Arabi M, Shah GV. Imaging of meningitis and ventriculitis. Neuroimaging Clin N Am. 2012;22(4):557-583. https://doi.org/10.1016/j.nic.2012.04.003
» https://doi.org/10.1016/j.nic.2012.04.003 -
6.Ahmad A. Differentiation of leptomeningeal and vascular enhancement on post-contrast flair MRI sequence: Role in early detection of infectious meningitis. J Clin Diagn Res. 2015;9(1):TC08-TC12. https://doi.org/10.7860/jcdr/2015/11519.5387
» https://doi.org/10.7860/jcdr/2015/11519.5387 -
7.Proulx N, Frechette D, Toye B, Chan J, Kravcik S. Delays in the administration of antibiotics are associated with mortality from adult acute bacterial meningitis. QJM. 2005;98(4):291-298. https://doi.org/10.1093/qjmed/hci047
» https://doi.org/10.1093/qjmed/hci047 -
8.Kamr WH, Eissawy MG, Saadawy A. The value of contrast-enhanced flair magnetic resonance imaging in detecting meningeal abnormalities in suspected cases of meningitis compared to conventional contrast-enhanced T1WI sequences. Egypt J Radiol Nucl Med. 2020;51(1):231. https://doi.org/10.1186/s43055-020-00348-2
» https://doi.org/10.1186/s43055-020-00348-2 - 9.Thurnher MM, Sundgren PC. Intracranial infection and inflammation. In: Hodler J, Kubik-Huch RA, von Schulthess GK, editors. Diseases of the brain, head and neck, spine 2020-2023: Diagnostic imaging. Cham (CH): Springer, 2020; p. 59-76.
-
10.Azad R, Tayal M, Azad S, Sharma G, Srivastava RK. Qualitative and quantitative comparison of contrast-enhanced fluid-attenuated inversion recovery, Magnetization Transfer Spin Echo, and fat-saturation T1-weighted sequences in infectious meningitis. Korean J Radiol. 2017;18(6):973. https://doi.org/10.3348/kjr.2017.18.6.973
» https://doi.org/10.3348/kjr.2017.18.6.973 -
11.Mishra S, Naik S, Bhoi SK, et al. Comparison of post contrast fluid attenuated inversion recovery, 3D T1-SPACE, and T1W MRI sequences with fat suppression in the diagnosis of infectious meningitis. Neuroradiol J. 2023;36(5):572-580. https://doi.org/10.1177/19714009231163563
» https://doi.org/10.1177/19714009231163563 -
12.Ahmed M. Comparison of gadolinium based T1 weighted and FLAIR MR sequences for the assessment of leptomeningeal enhancement in Meningoencephalitis. Int J Radiol. 2018;5(1):163-171. https://doi.org/10.17554/j.issn.2313-3406.2018.05.49
» https://doi.org/10.17554/j.issn.2313-3406.2018.05.49 -
13.Vaswani AK, Nizamani WM, Ali M, Aneel G, Shahani BK, Hussain S. Diagnostic accuracy of contrast-enhanced Flair magnetic resonance imaging in diagnosis of meningitis correlated with CSF analysis. ISRN Radiol. 2014;2014:1-7. https://doi.org/10.1155/2014/578986
» https://doi.org/10.1155/2014/578986 -
14.McHugh ML. Interrater reliability: The kappa statistic [homepage on the Internet]. U.S. National Library of Medicine; 2012 [cited 2024 Aug 21]. Available from: https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3900052/
» https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3900052/ -
15.Han X. On statistical measures for data quality evaluation. J Geogr Inf Syst. 2020;12(03):178-187. https://doi.org/10.4236/jgis.2020.123011
» https://doi.org/10.4236/jgis.2020.123011 -
16.Mera J, Granados A, Toro J, et al. Intracranial meningeal enhancement characterization [homepage on the Internet]. 2017 [cited 2024 Aug 21]. Available from: https://www.webcir.org/revistavirtual/articulos/2017/4_noviembre/col/meningeo_eng.pdf
» https://www.webcir.org/revistavirtual/articulos/2017/4_noviembre/col/meningeo_eng.pdf -
17.Freeze WM, Van der Thiel M, De Bresser J, et al. CSF enhancement on post-contrast fluid-attenuated inversion recovery images; a systematic review. NeuroImage Clin. 2020;28:102456. https://doi.org/10.1016/j.nicl.2020.102456
» https://doi.org/10.1016/j.nicl.2020.102456 -
18.Dahal P, Parajuli S. Magnetic resonance imaging findings in Central Nervous System tuberculosis: A pictorial review. Heliyon. 2024;10(8):e29779. https://doi.org/10.1016/j.heliyon.2024.e29779
» https://doi.org/10.1016/j.heliyon.2024.e29779 -
19.Galassi W, Phuttharak W, Hesselink JR, Healy JF, Dietrich RB, Imbesi SG. Intracranial meningeal disease: Comparison of contrast-enhanced MR imaging with fluid-attenuated inversion recovery and fat-suppressed T1-weighted sequences [homepage on the Internet]. U.S. National Library of Medicine; 2005 [cited 2024 Aug 21]. Available from: https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7976502/
» https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7976502/ -
20.Dechasasawat T, Mingkwansook V. Diagnostic accuracy of postcontrast FLAIR MRI with subtraction for detecting leptomeningeal disease. Sci Tech Asia [serial online]. 2022 [cited 2024 Nov 02];27(4):50-57. Available from: https://ph02.tci-thaijo.org/index.php/SciTechAsia/article/view/247902
» https://ph02.tci-thaijo.org/index.php/SciTechAsia/article/view/247902 -
21.Gad M, Elsorogy LG, Moustafa SA. Diagnostic utility of contrast-enhanced Flair MRI in imaging of demyelinating and infectious brain lesions. Egypt J Radiol Nucl Med. 2023;54(1):104. https://doi.org/10.1186/s43055-023-01049-2
» https://doi.org/10.1186/s43055-023-01049-2 -
22.Jeevanandham B, Kalyanpur T, Gupta P, Cherian M. Comparison of post-contrast 3D-T1-MPRAGE, 3D-T1-SPACE and 3D-T2-FLAIR MR images in evaluation of meningeal abnormalities at 3-T MRI. Br J Radiol. 2017;90(1074):20160834. https://doi.org/10.1259/bjr.20160834
» https://doi.org/10.1259/bjr.20160834 -
23.Sommer NN, Lucas RP, Coppenrath E, et al. Contrast-enhanced modified 3D T1-weighted TSE black-blood imaging can improve detection of infectious and neoplastic meningitis. Eur Radiol. 2019;30(2):866-876. https://doi.org/10.1007/s00330-019-06475-3
» https://doi.org/10.1007/s00330-019-06475-3 -
24.Stuckey SL, Goh TD, Heffernan T, Rowan D. Hyperintensity in the subarachnoid space on Flair MRI. Am J Roentgenol. 2007;189(4):913-921. https://doi.org/10.2214/ajr.07.2424
» https://doi.org/10.2214/ajr.07.2424 -
25.Lavdas E, Mavroidis P, Kostopoulos S, et al. Improvement of image quality using blade sequences in Brain MR imaging. Magn Reson Imaging. 2013;31(2):189-200. https://doi.org/10.1016/j.mri.2012.08.001
» https://doi.org/10.1016/j.mri.2012.08.001
Accepted: 20 Nov. 2024
Published: 27 Jan. 2025