Open-access Role of elasticity imaging/B-mode imaging ratio in the evaluation of solid breast lesions

Abstract

BACKGROUND: Ultrasound elastography, with the measurement of the lesional width ratio between elasticity imaging (EI) and B-mode image (BI) (EI/BI), provides a non-invasive method for breast cancer (BC) characterisation. Evidence from a limited number of researchers supporting the efficacy of this ratio in avoiding unnecessary biopsies warrants further exploration OBJECTIVES: To assess the role of the EI/BI ratio in the evaluation of solid breast lesions and correlate the findings with histopathological results METHOD: The study enrolled 54 female patients with clinically palpable breast lesions, non-palpable breast lesions (seen on mammography or ultrasound) and high-risk female participants with a positive family history of BC. Using ultrasound elastography, the EI/BI ratio was calculated and correlated with the histology using the Chi-square test and Cramer's V test RESULTS: The mean age was 41.9 ± 11.8 years, and 59.2% had fibroadenomas. The EI/BI ratio was ≥ 1 in 16 (29.6%) cases, where malignancy was confirmed on histology in all cases. Thirty-eight cases were benign as per the EI/BI ratio (< 1), of which 2 were found to be malignant. A significant correlation was seen between the EI/BI ratio and histopathology findings (p < 0.001). The specificity, sensitivity, positive and negative predictive values and diagnostic accuracy of the EI/BI ratio were 100%, 88.9%, 94.7%, 100% and 96.3%, respectively CONCLUSION: The EI/BI ratio is effective in differentiating between benign and malignant solid breast lesions, with a statistically significant correlation with histopathology CONTRIBUTION: The study validates the use of EI/BI ratio by radiologists to effectively differentiate between benign and malignant breast lesions in patients

breast neoplasm; elasticity imaging techniques; ultrasound elastography; histopathology; EI/BI ratio


Introduction

Breast cancer (BC) is the most common malignancy among women with an annual global incidence of 2.1 million, causing the highest number of cancer-related deaths in women.12,31

Mammography and ultrasound are the commonly employed diagnostic modalities for BC because of their high sensitivity.456,7

A more accurate, non-invasive method used for BC evaluation is ultrasound elastography.48910111210

There is limited literary evidence that explores the use of ultrasound elastography in the potential diagnosis of BC. This research is therefore aimed at assessing the role of the EI/BI ratio in the evaluation of solid breast lesions and correlation of the findings with histopathological results in a tertiary care hospital in Karad, India.

Research methods and design

Study design and participants

A prospective, observational, analytical study was conducted at a tertiary care hospital in India, between 01 June 2024 and 31 December 2024. Female patients with clinically palpable and non-palpable breast lesions (seen on mammography or ultrasound) and high-risk female participants with a positive family history of BC, who were scheduled for breast ultrasound, were included after obtaining written informed consent. Patients with cystic breast lesions, recurrent BC following chemotherapy or radiotherapy, and pregnant women, were excluded.

The sample size was calculated using Buderer's formula (Equation 1)13

where, n = required sample size, SN = anticipated sensitivity, α = size of the critical region (1 - α is the confidence level), z1−α/2 = standard normal deviate corresponding to the specified size of the critical region (α), and L = absolute precision desired on either side (half-width of the confidence interval) of sensitivity. The prevalence was considered to be 20%, a margin of error of 10%, and a 95% confidence level (Z = 1.96). The prevalence data in a study by Farooq et al. closely matched the demographic and clinical characteristics of our target population. They found that the sensitivity of elastography for differentiating benign from malignant breast lesions was 92%.14

Ultrasound procedure

Detailed clinical history and physical examination findings were recorded from each patient. Ultrasound elastography was performed using an ACUSON S2000 diagnostic ultrasound system (Siemens Medical Solutions, CA, US) with a 4 MHz - 6 MHz, 9L4 linear probe. The BI of the lesion was determined initially, followed by the EI, acquired using Acoustic Radiation Force Impulse (ARFI) technology and Virtual Touch Imaging (VTI). The BIRADS staging was determined as well.

The lesion width was measured in the same location on the BI and EI. The EI/BI ratio (width ratio) was then calculated by dividing the maximal horizontal length of the lesion measured on the EI by the corresponding length measured on the BI. If an echogenic ring was present around the lesion on BI, it was not included in the measurement. An EI/BI ratio ≥ 1 was considered as malignant while < 1 as benign.10,12

Statistical analysis

Data were compiled and analysed using Microsoft Excel and statistical software R version 3.6.3. Continuous variables were presented as mean ± standard deviation (s.d.) while categorical variables were presented as number (%). The Chi-square test was used to evaluate the association between attributes; a p value of ≤ 0.05 was considered statistically significant. Strength of association was measured by Cramer's V/odds ratio.

Ethical considerations

The study was conducted in accordance with the Declaration of Helsinki. All patients provided signed written informed consent before being enrolled in the study. The study protocol was approved by the Institutional Ethics Committee of the University (reference number: KVV/IEC/07/2024). The data collected were anonymised to ensure patient privacy.

Results

A total of 54 female patients were included in the study. The number of patients aged between 40 and 49 years was higher than other age groups (37.0%), and the mean age was 42.0 ± 11.8 years. The right breast was involved in 72.2% of cases. Table 1 presents a summary of the various parameters analysed in the study. Of the various breast tumours, fibroadenoma was diagnosed in 59.3% of the patients. The BI revealed that 72.2% of the lesions were well-circumscribed and 48.1% were lobulated. The EI/BI ratio was ≥ 1 in 16 (29.6%) cases, where malignant transformation was confirmed with ultrasound elastography and histopathology. The remaining 38 cases were found to be benign by EI/BI ratio (< 1), of which 2 were found to be malignant on histopathology.

The Chi-square test showed no significant correlation between the breast involved and the histopathology findings (p = 1.00). However, a significant correlation was found between the EI/BI ratio and histopathology findings (p < 0.001). From Cramer's V (0.9177), the strength of correlation was found to be very high (Table 2).

Figure 1 depicts the receiver operating curve (ROC) of sensitivity and specificity. The area under the ROC (AUROC) was observed to be 0.9737 (0.9377-1.0000). The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and diagnostic accuracy of the EI/BI ratio for classifying breast lesions into benign and malignant were found to be 100%, 88.9%, 94.7%, 100% and 96.3%, respectively (elastography correctly diagnosed 52 of the 54 lesions).

Discussion

This study assessed the role of the EI/BI ratio in the evaluation of solid breast lesions and correlates the findings with histopathological results. While all lesions with EI/BI ≥ 1 were indeed found to be malignant on histopathology, 2 of the 38 lesions with EI/BI < 1 were subsequently diagnosed as malignant on biopsy. However, the ultrasound elastography - histopathology correlation was found to be statistically significant.

The results closely mirror the observations by Barr et al. and Destounis et al., who measured the largest dimensions of the EI and the BI images, represented by the central hypoechoic part of the lesion and excluding the echogenic halo.12,1512,15

Similarly, Destounis et al. also observed that in 100 malignant lesions, 99 had an EI/BI ratio ≥ 1, while 1 had EI/BI ratio < 1. These results indicated 99% sensitivity, 91.5% specificity, 90% PPV and 99.2% NPV, all of which are highly comparable to the current research.151216

In concordance with this study, Grajo et al. found a significantly positive correlation between the width ratio and tumour grade (p < 0.001).101010,17

This study confirms and supports that ultrasound elastography along with routine BI, provides a convenient, practical, and non-invasive method for characterising breast lesions as benign or malignant. This may potentially reduce the number of unnecessary biopsies and invasive procedures, particularly for BI-RADS III or IVa lesions.

Study limitations

This was a single-centre study with a small sample size, and the outcomes cannot be generalised to a broader population. In breast ultrasound, high-frequency linear probes, typically operating in the 10 MHz - 15 MHz range or higher, are routinely utilised to optimise spatial resolution and tissue detail, both of which are critical for accurate lesion characterisation. In this study, a 4 MHz - 6 MHz (9L4) linear probe was used. The choice of a lower-frequency probe may be justified in cases requiring greater depth penetration, such as imaging in patients with large breasts, deeply located lesions or certain body habitus considerations. However, it is important to recognise that the use of a lower-frequency probe may result in decreased image resolution, particularly in the superficial tissues where many breast lesions are found. This could potentially impact the visualisation of lesion margins, internal architecture and subtle tissue abnormalities, thereby affecting diagnostic accuracy and BI-RADS categorisation. As such, the use of the 4 MHz - 6 MHz probe represents a methodological limitation of this study and should be taken into account when interpreting the results. Another limitation of this study is the lack of stratification of the EI/BI ratio findings against tumour grade or BI-RADS categories because of sample limitations. While the overall relationship between EI/BI ratios and lesions was explored, stratifying these findings according to tumour grade and BI-RADS categories would have provided a more granular understanding of their diagnostic value. Such stratification could potentially reveal how EI/BI ratios vary across different tumour grades (e.g. low-grade versus high-grade) and BI-RADS categories, further refining their role in tumour characterisation and malignancy risk assessment. Nonetheless, this study provides important data that support the effectiveness of ultrasound elastography in the diagnosis of BC.

Conclusion

This study validates the use of the EI/BI ratio for the evaluation of solid breast lesions, demonstrating a statistically significant correlation between the ultrasound elastography and histopathology. Ultrasound elastography can be used in conjunction with other imaging modalities to effectively diagnose and differentiate between the malignant and the benign lesions. Large multicentric, long-term, prospective studies with larger sample sizes are needed to validate the results and establish the utility of ultrasound elastography for the diagnosis of BC.

Competing interests

The authors declare that they have no financial or personal relationships that may have inappropriately influenced them in writing this article.

Authors' contributions

A.A.G., R.A., C.V.U. and A.I.T. contributed towards the drafting of the manuscript, clinical studies, concept and design. R.A., C.V.U. and A.I.T. contributed to the data acquisition and analysis. A.I.T. was responsible for the supervision and provided the overall guidance. All authors have reviewed the final version to be published and agreed to be accountable for all aspects of the work.

Funding information

This research received no specific grant from any funding agency in the public, commercial or not-for-profit sectors.

Data availability

The data that support the findings of this study are available on request from the corresponding author, A.I.T.

Disclaimer

The views and opinions expressed in this article are those of the authors and are the product of professional research. The article does not necessarily reflect the official policy or position of any affiliated institution, funder, agency or that of the publisher. The authors are responsible for this article's results, findings and content.

Acknowledgements

The authors would like to thank all the participating patients for being part of this study. The authors would like to thank Lakshya Untwal for formatting and editorial support as per Good Publication Practice 2022 guidelines.

References

  • 1. World Health Organization. Breast cancer [homepage on the Internet]. 2020 [cited 2025 Jan 15]. Available from: https://www.who.int/cancer/prevention/diagnosis-screening/breast-cancer/en/
    » https://www.who.int/cancer/prevention/diagnosis-screening/breast-cancer/en/
  • 2. Malvia S, Bagadi SA, Dubey US, Saxena S. Epidemiology of breast cancer in Indian women. Asia Pac J Clin Oncol. 2017;13(4):289-295. https://doi.org/10.1111/ajco.12661
    » https://doi.org/10.1111/ajco.12661
  • 3. Ghoncheh M, Mahdavifar N, Darvishi E, Salehiniya H. Epidemiology, incidence and mortality of breast cancer in Asia. Asian Pacific J Cancer Prev. 2016;17(suppl 3):47-52. https://doi.org/10.7314/APJCP.2016.17.S3.47
    » https://doi.org/10.7314/APJCP.2016.17.S3.47
  • 4. Khanduri S, Khan M, Shukla A, et al. Characterization of breast lesions using a novel combined approach of ultrasonography and elastography prior to invasive procedures: Are new age modalities set to replace the diagnostic giant?. Cureus. 2019;11(6):e4954. https://doi.org/10.7759/cureus.4954
    » https://doi.org/10.7759/cureus.4954
  • 5. Saarenmaa I, Salminen T, Geiger U, et al. The effect of age and density of the breast on the sensitivity of breast cancer diagnostic by mammography and ultrasonography. Breast Cancer Res Treat. 2001;67:117-123. https://doi.org/10.1023/A:1010627527026
    » https://doi.org/10.1023/A:1010627527026
  • 6. D'Orsi CJ, Sickles EA, Mendelson EB, Morris EA, editors. ACR BI-RADS® Atlas: Breast imaging reporting and data system. Reston, VA: American College of Radiology; 2013.
  • 7. Athanasiou A, Tardivon A, Tanter M, et al. Breast lesions: Quantitative elastography with supersonic shear imaging - Preliminary results. Radiology 2010;256(1):297-303. https://doi.org/10.1148/radiol.10090385
    » https://doi.org/10.1148/radiol.10090385
  • 8. Sigrist RMS, Liau J, Kaffas AE, Chammas MC, Willmann JK. Ultrasound elastography: Review of techniques and clinical applications. Theranostics. 2017;7(5):1303-1329. https://doi.org/10.7150/thno.18650
    » https://doi.org/10.7150/thno.18650
  • 9. Grajo JR, Barr RG. Compression elasticity imaging of the breast: An overview. Appl Radiol. 2012;41(10):18-19. https://doi.org/10.37549/AR1938
    » https://doi.org/10.37549/AR1938
  • 10. Grajo JR, Barr RG. Strain elastography for prediction of breast cancer tumor grades. J Ultrasound Med. 2014;33(1):129-134. https://doi.org/10.7863/ultra.33.1.129
    » https://doi.org/10.7863/ultra.33.1.129
  • 11. Hall T, Svensson W, Behren PV, et al. Lesion size ratio for differentiating breast masses. IEEE Symposium on Ultrasonics; 2003 Oct 05-08, Honolulu, HI, US. New York: IEEE; 2003. p. 1247-1250. https://doi.org/10.1109/ULTSYM.2003.1293128
    » https://doi.org/10.1109/ULTSYM.2003.1293128
  • 12. Barr RG, Destounis S, Lackey LB 2nd, Svensson WE, Balleyguier C, Smith C. Evaluation of breast lesions using sonographic elasticity imaging: A multicenter trial. J Ultrasound Med. 2012;31:281-287. https://doi.org/10.7863/jum.2012.31.2.281
    » https://doi.org/10.7863/jum.2012.31.2.281
  • 13. Buderer NM. Statistical methodology: I. Incorporating the prevalence of disease into the sample size calculation for sensitivity and specificity. Acad Emerg Med. 1996;3(9):895-900. https://doi.org/10.1111/j.1553-2712.1996.tb03538.x
    » https://doi.org/10.1111/j.1553-2712.1996.tb03538.x
  • 14. Farooq F, Mubarak S, Shaukat S, et al. Value of elastography in differentiating benign from malignant breast lesions keeping histopathology as gold standard. Cureus. 2019;11(10):e5861. https://doi.org/10.7759/cureus.5861
    » https://doi.org/10.7759/cureus.5861
  • 15. Destounis S, Arieno A, Morgan R, et al. Clinical experience with elasticity imaging in a community-based breast center. J Ultrasound Med. 2013;32(2):297-302. https://doi.org/10.7863/jum.2013.32.2.297
    » https://doi.org/10.7863/jum.2013.32.2.297
  • 16. Alhabshi SM, Rahmat K, Abdul Halim N, et al. Semi-quantitative and qualitative assessment of breast ultrasound elastography in differentiating between malignant and benign lesions. Ultrasound Med Biol. 2013;39(4):568-578. https://doi.org/10.1016/j.ultrasmedbio.2012.10.016
    » https://doi.org/10.1016/j.ultrasmedbio.2012.10.016
  • 17. Harvey JM, De Klerk NH, Sterrett GF. Histological grading in breast cancer: Interobserver agreement and relation to other prognostic factors including ploidy. Pathology. 1992;24(2):63-68. https://doi.org/10.3109/00313029209063625
    » https://doi.org/10.3109/00313029209063625

Correspondence:
Asif Tamboli

Received: 26 Mar. 2025
Accepted: 05 May 2025
Published: 23 July 2025

Correspondence

drtamboliasif@gmail.com

Publication Dates

  • Publication in this collection
    20 Jan 2026
  • Date of issue

History

  • Received
    26 Mar 2025
  • Accepted
    05 May 2025
location_on
Radiological Society of South Africa AOSIS Publishing, Postnet Suite #110, Private Bag X19, Durbanville, Cape Town, Western Cape Province, ZA, 7551, Tel: +27 21 975 2602, Tel: 086 1000 381 - E-mail: publishing@aosis.co.za
rss_feed Stay informed of issues for this journal through your RSS reader
Go to top