The voltammetric behaviour of resazurin in the presence of Cd2+ and Zn2+ ions at a hanging mercury drop electrode (HMDE) was investigated by using square wave voltammetry (SWV), cyclic voltammetry (CV) and adsorptive square wave voltammetry (AdsSWV). The interaction of resazurin with Cd2+ and Zn2+ starts above pH 4 and seems to be completed at pH 5.2 with Cd2+ ions and at pH 7.5 with Zn2+ ions. A new peak appears at -0.93 V in the presence of Cd2+ and at -1.07 V in the presence of Zn2+. These peaks may be attributed to M2+-resazurin complexes and the logarithm of their stability constant was determined where log β14 = 4.22 for Cd2+-resazurin and log β1:1 = 4.74 for Zn2+-resazurin. Cyclic voltammetry was used to characterize the redox mechanism and to calculate voltammetric data of M2+-resazurin complexes. The amount of adsorbed M2+-resazurin complexes on the mercury drop electrode surface (Γ) is calculated as 5.48 x 10-12 mol cm-2 for Cd2+-resazurin and 1.10 x 10-11 mol cm-2 for Zn2+-resazurin. The voltammetric data were compared with the data obtained using spectrophotometric methods and were observed to be in good agreement.
Resazurin; cadmium; zinc; electrochemistry; spectroscopy; metal complexes
An investigation of the interaction between resazurin and Cd2+ and Zn2+ ions in aqueous medium
Emine Yimaz Arslan; Semiha Çakir*
Department of Chemistry, Faculty of Arts & Science, Gazi University, 06500 Teknikokullar-Ankara, Turkey
ABSTRACTThe voltammetric behaviour of resazurin in the presence of Cd2+ and Zn2+ ions at a hanging mercury drop electrode (HMDE) was investigated by using square wave voltammetry (SWV), cyclic voltammetry (CV) and adsorptive square wave voltammetry (AdsSWV). The interaction of resazurin with Cd2+ and Zn2+ starts above pH 4 and seems to be completed at pH 5.2 with Cd2+ ions and at pH 7.5 with Zn2+ ions. A new peak appears at -0.93 V in the presence of Cd2+ and at -1.07 V in the presence of Zn2+. These peaks may be attributed to M2+-resazurin complexes and the logarithm of their stability constant was determined where log β14 = 4.22 for Cd2+-resazurin and log β1:1 = 4.74 for Zn2+-resazurin. Cyclic voltammetry was used to characterize the redox mechanism and to calculate voltammetric data of M2+-resazurin complexes. The amount of adsorbed M2+-resazurin complexes on the mercury drop electrode surface (Γ) is calculated as 5.48 x 10-12 mol cm-2 for Cd2+-resazurin and 1.10 x 10-11 mol cm-2 for Zn2+-resazurin. The voltammetric data were compared with the data obtained using spectrophotometric methods and were observed to be in good agreement.
Keywords: Resazurin, cadmium, zinc, electrochemistry, spectroscopy, metal complexes
Full text available only in PDF format.
References
- 1 F. Tasca, L. Gorton, W. Harreither, D. Haltrich and R. Ludwig, G. No, Anal. Chem. 2009, 81, 2791-2798.
- 2 M.N. Zafar, F. Tasca, L. Gorton, E.V Patridge, J.G. Ferry and G. No, Biosensors and Biofuel Cells, 2009, 81, 4082-4088.
- 3 C.N. Baker, S.N. Banerjee and F.C. Tenover, J. Clin. Microbiol., 1994, 32, 1261-1267.
- 4 R.J. Zabransky, A.R. Dinuzzo and G.L. Woods, J. Clin Microbiol., 1995, 33, 791-793.
- 5 A. Puszko, L. Wasylina, M. Pelczynska, Z. Staszak, A. Adach, M.A. Golonka and M. Kubiak, J. Inorg. Biochem., 2007, 101, 117-126.
- 6 H. Icbudak, E. Adiyaman, A. Uyanik and S. gakrr, Transit. Metal. Chem., 2007, 32, 864-869.
- 7 S.Çakir and E. Bicer, Turk. J. Chem., 2007, 31, 223-231.
- 8 S.Çakir and E. Bicer, Bioelectrochem., 2005, 67, 75-80.
- 9 S.Çakir and E. Bicer, Bioelectrochem., 2004, 64, 1-6.
- 10 Çakir, E. Bicer, E. Coşkun and O. Çakir, Bioelectrochem., 2003, 60, 11-19.
- 11 S. Çakir, I. Bulut, E. Bicer and O. Çakir, J. Coord. Chem., 2003, 56, 511-521.
- 12 Çakir, E. Coşkun, E. Bicer and O. Çakir, Carbohyd. Res., 2003, 338, 1217-1222.
- 13 Çakir, E. Bicer, P. Naumov and Çakir, J. Coord. Chem., 2002, 55, 1461-1471.
- 14 Çakir, E. Bicer, E. Coşkun, P. Naumov and O. Çakir, Pol. J. Chem., 2002, 76, 663-669.
- 15 T. Kubota and H. Miyazaki, Bull. Chem. Soc. 1962, 35, 1549-1551.
- 16 S.C. Leach, R.D. Weaver, K. Kinoshita and W.W. Lee, J. Electroanal. Chem., 1981, 129, 213-227.
- 17 S. gakrr and E.Y. Arslan, Chem. Pap., 2010, 64, 386-394.
- 18 L. Fotouhi, E. Kohestanian and M.M. Heravi, Electrochem. Commun., 2006, 8, 565-570.
- 19 L.M. Goldenberg, J.F. Biernat and M.C. Petty, Langmuir, 1998, 14, 1236-1241.
- 20 J.J. Gooding, D.B. Hibbert and W. Yang, Sensors, 2001, 1, 75-90.
- 21 Z.M. Kompany and Y. Beyad, Anal. Chim. Acta, 2008, 621, 163-170.
- 23 N.Q. Li and J. Min, Fen Xi Hua Xue, Chin. J. Anal. Chem., 1989, 17, 346-349.
- 24 R.Ernst, H.E. Allen and K.H. Mancy, Water Research, 1975, 9, 969-979.
- 26 A.M. Hernan, M. Gervaldo and S.G. Bertolotti, Dyes Pigments, 2005, 64, 117-124.
- 27 Y. Matsunaga, K. Fujisawa, N. Amir, Y. Miyashita and K. Okamoto, Transit. Metal. Chem., 2006, 31, 897-906.
- 29 F.A. Villamena, V Horak and D.R. Crist, Inorg. Chim. Acta, 2003, 342, 125-130.
- 30 R. Sarma, A. Karmakar and J.B. Baruah, Inorg. Chim. Acta, 2008, 361, 2081-2086.
- 31 C. Urquiola, D. Gambino, M. Cabrera, M.L. Lavaggi, H. Cerecetto, M. Gonzalez, A.L. Cerain, A. Monge, A.J. Costa-Filho and M.H. Torre, J. Inorg. Biochem., 2008, 102, 119-126.
Revised 27 September 2010
Accepted 10 October 2010