Open-access Determination oF metformin at metal-organic framework (Cu-BTC) Nanocrystals/multi-walled carbon nanotubes modified glassy carbon electrode

Abstract

Glassy carbon (GC) electrode modified with Cu-based metal-organic frameworks (Cu-BTC, BTC = 2,3,5-benzenetricarboxylate) and multi-walled carbon nanotubes (CNTs) composites was developed. The Cu-BTCs were synthesized by two methods, traditional hydrothermal and ultrasonic irradiation methods. It was found that the Cu-BTC that was synthesized by the latter method, with mean crystallite sizes in the nanometers range, showed a higher impact on enhancing the electrocatalytic activity of the modified electrode toward the electro-oxidation of metformin compared to that synthesized with the former method with a larger crystallite size of micrometer-scale. The morphological characteristics of Cu-BTCs and Cu-BTC nanocrystals/CNTs modified GC electrode surface were characterized by scanning electron microscopy. The modified electrode showed excellent response of oxidation current for the determination of metformin. Under optimum conditions, the peak current showed good linearity with concentrations in the range of 0.5 μΜ to 25 μΜ and a detection limit of 0.12 μΜ, as well as good repeatability. The Cu-BTC nanocrystals/CNTs modified GC electrode was applied successfully to determine metformin in pharmaceutical samples with good accuracy.

Metal-organic framework; carbon nanotube; modified glassy carbon electrode; metformin; electroanalytical determination


1. Introduction

Metformin is an antidiabetic medication and is considered as a first-line drug choice for the treatment of type 2 diabetes.12,3 chromatography,41314152425262742829303128-31Thus, the aim of this work was to develop a new, simple and sensitive electroanalytical method for the determination of metformin in pharmaceutical formulations. The electrochemical sensor was a GC electrode simply modified with a Cu-based MOF (Cu-BTC) nanocrystals/multi-walled CNTs hybrid nanostructure.

In the past decade, CNTs have become the focus of great interest on the fabrication of chemically modified electrodes due to their large surface area, unique architecture, and remarkable mechanical and electrical properties.32,33 Their large surface area could increase the electron transfer rate and produce higher response sensitivity due to its high adsorption capability to target analyte molecules. Also, the porous nature of the drop-cast fabricated CNT films may provide a supportive scaffold for the uniform deposition of the MOF nanocrystals.

From the last decade, MOFs that are constructed of metal ions coordinated to organic linkers to form one-, two-, or three-dimensional highly ordered porous structures have attracted much attention due to their high accessible surface area and porosity and have been applied in a variety of fields such as gas separation, sensors, ion exchange, catalysis and supercapacitors.3536,37 More recently, MOF-based multi-components materials have been proposed, in which the combination of MOFs and highly conductive nanostructured materials provides added conductivity and electrocatalytic ability against target analytes. For example, immobilization of Au-SH-SiO2 nano-particles on Cu-based MOF for l-cysteine38392O2 sensing,40412O2 sensing,4243444546

MOFs have been routinely synthesized by hydro/solvothermal methods. Recently, ultrasonic irradiation reaction methods have been also introduced as facile, rapid and inexpensive route toward the synthesis of these compounds.4747

2. Experimental

2.1.

Materials

All chemicals were of analytical grade and were used as received, without further purification. The standard metformin hydrochloride (Sigma) solutions were prepared freshly before use. Multi-walled CNT (with the outside diameter of 5-15 nm and length of about 50 μm) was purchased from US Research Nanomaterials, Inc.

2.2.

Apparatus

Voltammetric experiments were performed using a Sama potentiostat/galvanostat model 500 (Isfahan, Iran). A graphite rod (0.5 cm x 2 cm) served as an auxiliary electrode and an Ag/AgCl (3 M KCl) electrode was used as a reference electrode. Synthesis of the Cu-BTC nanocrystals was performed in a Rocker ultrasonic bath (Soner 203). The SEM images were obtained with a Hitachi S4160 (Cold Field Emission) scanning electron microscope. Prior to SEM examination, the SEM samples were coated with a thin film of Au in a coating machine to enhance their conductivity.

2.3.

Synthesis of Cu-BTCs

2.3.1. Synthesis of Cu-BTC Microcrystals

Cu-BTC microcrystals was synthesized using a similar method to that reported by J. Gascon et al.483)2 3H2O were added to 5 mL de-ionized water and mixed with 0.14 g of 1,3,5-benzenetricarboxylic acid (H3BTC) dissolved in 5 mL ethanol. The resulting solution was stirred for 30 min at room temperature, then heated at 383 K for 18 h in a teflon-lined stainless steel bomb. After cooling to room temperature, the product was isolated from the solution as a blue powder following centrifugation, washed three times with ethanol, and then dried at 130 °C for 12 h.

2.3.2. Synthesis of Cu-BTC Nanocrystals

Cu-BTC nanocrocrystals was synthesized following the procedure of [49]. Briefly, 0.104 g of H3BTC was dissolved in a solution of 4 mL dimethylformamide (DMF) and 2 mL ethanol and then added to 3 mL of an aqueous solution of 0.099 g cupric acetate dihydrate. Then, the reaction mixture was ultrasonicated continuously for 5 min at a frequency of 40 KHz. After the ultrasonic irradiation, the resulting blue powder was isolated from the solution and then dried by the same manner as described above for the Cu-BTC microcrystals.

2.4. Fabrication of the Cu-BTC/CNTs Modified GC Electrode

CNTs, Cu-BTC microcrystals and Cu-BTC nanocrystals were cast onto GC electrode surfaces. They were first dispersed in DMF at a concentration of 1 mg mL-1 in an ultrasonic bath. The dispersions of Cu-BTCs are shown in Fig. 1. As can be seen from this figure, due to a higher particle weight of Cu-BTC micro-crystals, they settle in the suspension very much sooner than Cu-BTC nanocrystals that form a colloidal suspension. Prior to modification, the bare GC electrode surface was polished with 0.05 μm α-AL2O3, and then rinsed with distilled water. To prepare CNTs modified GC electrode, 2 μL of CNT suspension was cast onto the electrode surface with a micro-syringe pipette and its solvent was then allowed to evaporate under an infrared lamp.

In order to prepare Cu-BTC modified GC electrodes, 2 μL of Cu-BTC microcrystals or Cu-BTC nanocrystals suspensions were placed onto the CNTs modified GC electrode surface following dryness under infrared lamp, designated as Cu-BTC (micro)/CNTs modified or Cu-BTC (nano)/CNTs modified GC electrodes, respectively.

3. Results and Discussion

3.1. Morphological Characterization of Cu-BTC

The SEM images shown in Fig. 2A and and Fig. 2B illustrate the crystal morphologies of the Cu-BTC prepared using hydrother-mal and ultrasonic methods, respectively. As can be seen from Fig. 2A, the Cu-BTC crystals obtained under conventional hy-drothermal method show a very larger size range (20-40 μηι) than those synthesized using ultrasonic method (40-100 nm). These results are consistent with those reported previously using traditional hydrothermal4849Fig. 2C shows a SEM image from the surface of Cu-BTC (nano)/CNTs modified GC electrode. One of The MOF nanoparticles, which settled on the wall of CNTs is indicated by the white dashed lines in this figure.



3.2. Electrochemical Characteristics of Cu-BTC (Nano)/CNTs and Cu-BTC Micro/CNTs Modified GC Electrodes

Cyclic voltammograms of metformin on a bare GC electrode (2), Cu-BTC (micro) modified GC (3), Cu-BTC (nano) modified GC (4), CNTs modified GC (5), Cu-BTC (micro)/CNTs modified GC (6), and Cu-BTC (nano)/CNTs modified GC (7) electrodes are shown in Fig. 3 and the electrochemical results are summarized in Table 1 ease of comparison.

The bare GC electrode shows a very low electrode activity toward metformin. The anodic peak potential (Ep) of metformin appears at about 0.64 V on Cu-BTC (nano) modified GC and on CNTs modified GC at 0.64 V At the same time, the anodic peak of metformin on Cu-BTC (nano)/CNTs modified GC appears at 0.59 V with a significantly enhanced peak current (Ip) (Fig. 3 and Table 1), which indicates an enhanced electron-transfer rate on the modified electrode. This is due to the synergistic effect from both the high conductivity and the large surface area of the CNT, along with the electron mediating action of Cu2502

A lower value of Ep (0.59 V) and a significantly higher value of Ip (73 μΑ) at the Cu-BTC (nano)/CNTs modified GC compared to Cu-BTC (micro)/CNTs modified GC electrode (Ep 0.63, Ip35 μΑ) as well as Cu-BTC (nano) modified GC (Ep 0.64, Ip 1.3 μΑ) compared to Cu-BTC (micro) modified GC electrodes (Ep 0.69, Ip 0.73 μΑ) indicates clearly with the lower crystal size of MOF, the electrocatalytic performances of the modified electrodes is higher.

The scan rate (v) dependence of cyclic voltammograms for the Cu-BTC (nano)/CNTs modified GC electrode toward the oxidation of metformin was also explored (Fig. 4). At the v between 25 and 250 mV s-1, the slope of about 1.0 for the double logarithmic plots of the Ipvs. u indicates that the limiting current is controlled by adsorption process.

As illustrated in Fig. 5, considering the dimensions of the optimized structure of the metformin molecules that can be embedded into a presumptive ball of about 13 A ° diameter that fits the larger pores of Cu-BTC,51

This property along with the nanometer sized crystals of MOF, when accompanied with the large surface area and high electrocatalytic activity of the CNT, provides a high sensing performance and electrode sensitivity.

3.3. Effect of pH

The pH effect on the electro-oxidation of metformin was studied in solutions of different pH values from 5 to 9. Fig. 6 indicates that the solution pH has a significant influence on the electro-oxidation of metformin at the Cu-BTC (nano)/CNTs modified GC electrode and protons have taken part in the electrode reaction processes.

Fig. 6

As it can be seen from Fig. 6, the Ep value shifts negatively with the increase of the solution pH so that in the pH range of 5.82-11.65, the slope of the linear regression line through the data points (-0.053 mV pH-1), which is very close to the theoretical value of -0.059 mV pH-1, is consistent with the mechanism proposed for the metformin electro-oxidation based on the equal numbers of electrons and protons.29,50 The two linear regions of the Epvs. pH plot intersect at about 11.65 (Fig. 6), which are close to the pKa2 value (11.5) of metformin.52

As can be seen from Fig. 6, the ip increased with raising the solution pH so that the greatest ip value was obtained in the pH range of about 12.5-13.5. Approaching pH to pKa2 value, the progressive deprotonation of positively charged metformin molecules that causes a reduction in their repulsive interactions with the electrode surface during the anodic change of potential or with Cu2

3.4.

Optimization of the Amount of CNT and Cu-BTC (Nano)

The cyclic voltammetry experiments were conducted at the GC electrode modified with different amount of CNT (1 mg mL-1) dispersion. The relationship between the Ip value and the volume of CNT dispersion used for the electrode modification was illustrated in Fig. 7. As the signal was not improved above 2 μL, this volume was chosen as an optimum volume of the CNT dispersion.

The amount of Cu-BTC (nano) was also optimized by applying different amount of Cu-BTC (nano) dispersion (1 mg mL-1)on the CNTs modified GC electrode. From Fig. 7, it can be seen that the Ip value first rapidly increases with increasing the volume of Cu-BTC (nano) dispersion up to about 2 μL, and then slightly decreases with the higher dispersion volume (Fig. 7). This should be attributed to an increase in the electrical resistance of the electrode due to the excess of Cu-BTC (nano). The volume of the Cu-BTC (nano) dispersion chosen in the detection of metformin was 2 μL.

3.5.

Influence of Accumulation Time

Figure 8 shows the voltammograms obtained at the Cu-BTC (nano)/CNTs modified GC electrode at different accumulation time and the plot of the Ip value vs. the accumulation time is also shown in the inset of this figure.

It can be seen that the Iprises rapidly by increasing the preconcentration time up to 3 min, and after that tends to a constant value. The accumulation time chosen for further experiment was 3 min.

3.6. Analytical Figures of Merit

The effect of the varying concentration of metformin on Ipat the Cu-BTC (nano)/CNTs modified GC electrode at the optimized experimental conditions is shown in Fig. 9.

The Ipvalues increased linearly by increase the metformin concentration in the range of 0.50-25.00 μM. The Ip level off at 25.00 μM, probably due to saturation adsorption limitations. The correlation coefficient (0.995) of the linear least squares fit of the calibration curve indicates that the regression line is fitted very well with the experimental data (Fig. 9). The detection limit (signal to noise of 3) was calculated as 0.12and the sensitivity was 1.65 μΑμM-1. These analytical parameters, as can be seen from Table 2, are comparable and in most cases better than those reported by other researchers using other modified electrodes.

Table 2

Especially the modified electrode shows a significantly higher sensitivity compared to the other electrodes.

Figure 10 shows 7 replicate voltammograms obtained at the Cu-BTC (nano)/CNTs modified GC electrode in a solution containing 10 μM metformin, which can provide an estimate of the repeatability of the modified electrode. The GC electrode surface has been modified freshly for each measurement. The precision of the described method in terms of relative standard deviation of the Ip values was found to be 4.8 %, which indicates excellent electrochemical response repeatability of the modified electrodes.

3.7. Application

In order to demonstrate the applicability of the proposed method for the determination of metformin in pharmaceutical formulations, three commercial medicinal samples containing metformin were studied. The medicinal samples were Brot® (Medochemi Ltd., Cyprus), Hexal® (Hexal AG., Germany) and Glucophage® (Merck Santé S.A.S., France). The tablets were powdered and homogenized. 0.015 g of this powder was weighed and dissolved in the supporting electrolyte solution (0.1 M KOH) and then transferred quantitatively into a 100 mL flask and diluted to volume. 5 mL of this solution was diluted to 100 mL with the supporting electrolyte solution and 5 mL of this solution was added to the measurement cell. The calibration curve method was made simply with the working solution for determination of the content of metformin in the samples. The results obtained in the analysis of four replicates from each sample are summarized in Table 3 and show a satisfactory agreement with the labelled amounts.

3.8. Comparison with Other Methods

Some analytical data reported for determination of metformin by methods based on chromatography or spectrophotometry are compared with the proposed method in Table 4. As is clear from Table 4, compared to the other methods reported, the proposed method shows a detection limit and linear dynamic range comparable or in some cases slightly better although it should be noted that the high sensitivity, rapid analysis time, simplicity and low cost of analysis are the main advantages of the electrochemical voltammetric method over the chromatog-raphy-based or spectroscopy-based methods.

Table 4

4. Conclusion

In this paper, the Cu-BTCs were prepared and it was shown that their composites with multiwall CNT can be used as a suitable and effective electrode modifier for metformin determination in aqueous solution. It was shown that the MOF crystallite size has a significant influence on the electrocatalytic performance of the modified electrode so that the Cu-BTC crystals with nanometer dimensions, synthesized by the ultrasonic method, indicate higher electrocatalytic activity compared to those synthesized with conventional solvothermal method with micrometer-sized crystallite. The modified electrode was prepared by a simple procedure and showed good reproducibility. Analysis of metformin by voltammetric technique was performed in comparison to the other reported methods (Tables 2 and 4) with a long linear dynamic range of 0.50-25.00 μΜ and a low detection limit of 0.12 μΜ. The proposed modified electrode used as a sensitive, fast and simple voltammetric sensor for metformin determination in real pharmaceutical samples.

References

  • 1 A. Scheen and P. Lefebvre, Oral antidiabetic agents: a guide to selection, Drugs, 1998, 55, 225-236.
  • 2 J.Z. Song, H.F. Chen, S.J. Tian and Z.P. Sun, Determination of metformin in plasma by capillary electrophoresis using field-amplified sample stacking technique, J. Chromatogr. B, 1998, 708, 277-283.
  • 3 I.I. Hamdan, A.K.B. Jaber and A.M. Abushoffa, Development and validation of a stability indicating capillary electrophoresis method for the determination of metformin hydrochloride in tablets, J. Pharm. Biom. Anal., 2010, 53, 1254-1257.
  • 4 F. Tache, V. David, A. Farca and A. Medvedovici, HPLC-DAD determination of metformin in human plasma using derivatization with p-nitrobenzoyl chloride in a biphasic system, Microcem. J., 2001, 68, 13-19.
  • 5 S. AbuRuz, J. Millership and J. MaElnay, Determination of metformin in plasma using a new ion pair solid phase extraction technique and ion pair liquid chromatography, J. Chromatogr. B, 2003, 798, 203-209.
  • 6 M. Zhang, G.A. Moore, M. Lever, S.J. Gardiner, C.M. J. Kirkpatrick and E.J. Begg, Rapid and simple high-performance liquid chromatographic assay for the determination of metformin in human plasma and breast milk, J. Chromatogr. B, 2001, 766, 175-179.
  • 7 K.H. Yuen and K.K. Peh, Simple high-performance liquid chromatographic method for the determination of metformin in human plasma, J. Chromatogr. B, 1998, 710, 243-246.
  • 8 M.S. Lennard, C. Casey, G.T. Tucker and H.F. Woods, Determination of metformin in biological samples, Br. J. Clin. Pharmacol., 1978, 6, 183-185.
  • 9 S.K. Konidala and P. Hemanth, A simple and validated RP-HPLC method for the simultaneous determination of vildagliptin and metformin in bulk and pharmaceutical dosage forms, Int. J. Curr. Pharm. Res., 2014, 6, 31-35.
  • 10 S.R. Polagani, N.R. Pilli, R. Gajula and V. Gandu, Simultaneous determination of atorvastatin, metformin and glimepiride in human plasma by LC-MS/MS and its application to a human pharma-cokinetic study, J. Pharm. Anal, 2013, 3, 9-19.
  • 11 F. Al-Rimawi, Development and validation of an analytical method for metformin hydrochloride and its related compound (1-cyanoguanidine) in tablet formulations by HPLC-UV, Talanta, 2009, 79, 1368-1371.
  • 12 Y. Wang, Y. Tang, J. Gu, J.P. Fawcett and X. Bai, Rapid and sensitive liquid chromatography-tandem mass spectrometric method for the quantitation of metformin in human plasma, J. Chromatogr. B, 2004, 808, 215-219.
  • 13 A. Zarghi, S.M. Foroutan, A. Shafaati and A. Khoddam, Rapid determination of metformin in human plasma using ion-pair HPLC, J. Pharm. Biomed. Anal, 2003, 31, 197-200.
  • 14 H.H. Gadape and K.S. Parikh, Quantitative determination and validation of metformin hydrochloride in pharmaceutical using quantitative nuclear magnetic resonance spectroscopy, E -J. Chem., 2011, 8, 767-781.
  • 15 S.S.M. Hassan, W.H. Mahmoud, M.A.F. Elmosallamy and A.M. Othman, Determination of metformin in pharmaceutical preparations using potentiometry, spectrofluorimetry and UV-visible spectrophotometry, Anal. Chim. Acta, 1999, 378, 299-311.
  • 16 M.F. Abdel-Ghany, O. Abdel-Aziz, M.F. Ayad and M.M. Tadros, Validation of different spectrophotometric methods for determination of vildagliptin and metformin in binary mixture, Spectrochim. Acta, 2014, 125, 175-182.
  • 17 S.M. Riad, M.R. Rezk, G.Y. Mahmoud and A.E. Abdel-Aleem, Spectrophotometric determination of sitagliptin and metformin in their pharmaceutical formulation, Int. J. Comprehe. Pharm., 2012, 3, 1-4.
  • 18 R.I. El-Bagary, E.F. Elkady and B.M. Ayoub, Spectroflourometric and spectrophotometric methods for the determination of sitagliptin in binary mixture with metformin and ternary mixture with metformin and sitagliptin alkaline degradation product, Int. J. Biomed. Sci., 2011, 7, 62-69.
  • 19 M.R. Sohrabi, N. Kamali and M. Khakpour, Simultaneous spectrophotometric determination of metformin hydrochloride and glibenclamide in binary mixtures using combined discrete and continuous wavelet transforms, Anal. Sci., 2011, 27, 1037-1041.
  • 20 G. Mubeen, K. Noor and M.N. Vimala, Spectrophotometric method for estimation of metformin hydrochloride, Int. J. Chem. Tech. Res., 2010, 2, 1186-1187.
  • 21 M.S. Arayne, N. Sultana, M.H. Zuberi and F.A. Siddiqui, Spectrophotometric quantitation of metformin in bulk drug and pharmaceutical formulations using multivariate technique, Indian J. Pharm. Sci., 2009, 71, 331-335.
  • 22 G. Mubeen and K. Noor, Spectrophotometric method for analysis of metformin hydrochloride, Indian J. Pharm. Sci., 2009, 71, 100-102.
  • 23 P.S. Sudarshan and C.G. Bonde, Development and validation of analytical method for simultaneous estimation of glibenclamide anmin HCl in bulk and tablets using UV-visible spectroscopy, Int. J. Chem. Tech. Res., 2009,1, 905-909.
  • 24 S. Ashour and R. Kabbani, Direct spectrophotometric determination of metformin hydrochloride in pure form and in drug formulation, Anal. Lett, 2003, 36, 361-370.
  • 25 J.M. Calatayud, P.C. Falco and M.C.P. Marti, Metformin and moroxidine determination with Cu (II), Anal. Lett, 1985,18, 1381-1390.
  • 26 I.H.I. Habib and M.S. Kamel, Near infra-red reflectance spectroscopic determination of metformin in tablets, Talanta, 2003, 60, 185-190.
  • 27 A.K. Attia, W.M. Salem and M.A. Mohamed, Voltammetric assay of metformin hydrochloride using pyrogallol modified carbon paste electrode, Acta Chim. Slov., 2015, 62, 588-594.
  • 28 L.M. Blanco Jerez, U.M. García-Pérez, P. Zambrano-Robledo and J. Hernández-Moreira, Carbon paste electrode modified with BiVO4 to sense metformin, Int. J. Electrochem. Sci., 2014, 9, 4643-652.
  • 29 M.B. Gholivand and L. Mohammadi-Behzad, Differential pulse voltammetric determination of metformin using copper-loaded activated charcoal modified electrode, Anal. Biochem., 2013, 438, 53-60.
  • 30 X.j. Tian, J.f. Song, X. j. Luan, Y.y. Wang and Q.z. Shi, Determination of metformin based on amplification of its voltammetric response by a combination of molecular wire and carbon nanotubes, Anal. Bioanal. Chem., 2006, 386, 2081-2086.
  • 31 N. Sattarahmady, H. Heli and F. Faramarzi, Nickel oxide nanotubescarbon microparticles/Nafion nanocomposite for the electrooxidation and sensitive detection of metformin, Talanta, 2010, 82, 1126-1135.
  • 32 P. Papakonstantinou, R. Kern, L. Robinson, H. Murphy, J. Irvine, E. McAdams and J. McLaughlin, Fundamental electrochemical properties of carbon nanotube electrodes, Fuller. Nanotub. Car. N., 2005,13, 91-108.
  • 33 A. Merkoc, M. Pumera, X. Llopis, B. Perez, M. del Valle and S. Alegret, New materials for electrochemical sensing VI: carbon nanotubes, Trac-Trend Anal. Chem, 2005, 24, 826-838.
  • 34 Q.M. Wang, D.M. Shen, M. Bulow, M.L. Lau, S.G. Deng, F.R. Fitch, N.O. Lemcoff and J. Semanscin, Metallo-organic molecular sieve for gas separation and purification, Micropor. Mesopor. Mater., 2002, 55, 217-230.
  • 35 H. Zhou and S. Kitagawa, Metal-organic frameworks (MOFs), Chem. Soc. Rev., 2014, 43, 5415-5418.
  • 36 B. Yuan, R. Zhang, X. Jiao, J. Li, H. Shi and D. Zhang, Amperometric determination of reduced glutathione with a new Co-based metal-organic coordination polymer modified electrode, Electrochem. Commun, 2014,40, 92-95.
  • 37 K.F. Babu, M.A. Kulandainathan, I. Katsounaros, L. Rassaei, A.D. Burrows, P.R. Raithby and F. Marken, Electrocatalytic activity of BasoliteTMTM F300 metal-organic-framework structures, Electrochem. Commun, 2010,12, 632-635.
  • 38 H. Hosseini, H. Ahmar, A. Dehghani, A. Bagheri, A. Tadjarodi and A.R. Fakhari, A novel electrochemical sensor based on metal-organic framework for electro-catalytic oxidation of L-cysteine, Biosen. Bioelectron., 2013, 42, 426-429.
  • 39 H. Hosseini, H. Ahmar, A. Dehghani, A. Bagheri, A.R. Fakhari and M.M. Amini, Au-SH-SiO2 nanoparticles supported on metal-organic framework (Au-SH-SiO2@ Cu-MOF) as a sensor for electrocatalytic oxidation and determination of hydrazine, Electrochim. Acta. 2013,88, 301-309.
  • 40 E. Zhou, Y. Zhang, Y. Li and X.He, Cu(II)-Based MOF Immobilized on multiwalled carbon nanotubes: synthesis and application for nonenzymatic detection of hydrogen peroxide with high sensitivity, Electroanalysis, 2014, 26, 2526-2533.
  • 41 Y. Wang, H. Ge, G. Ye, H. Chen and X. Hu, Carbon functionalized metal organic framework/Nafion composites as novel electrode materials for ultrasensitive determination of dopamine, J. Mater. Chem. B, 2015, 3, 3747-3753.
  • Research Article
  • 42 Y. Zhang, X. Bo, C. Luhana, H. Wang, M. Li and L. Guo, Facile synthesis of a Cu-based MOF confined in macroporous carbon hybrid material with enhanced electrocatalytic ability, Chem. Commun., 2013, 49, 6885-6887.
  • 43 X. Wang, Q. Wang, Q. Wang, F. Gao, F. Gao, Y. Yang and H. Guo, Highly dispersible and stable copper terephthalate MOF-graphene oxide nanocomposite for electrochemical sensing application, ACS Appl. Mater. Interfaces, 2014, 6, 11573-11580.
  • 44 J. Zhou, X.Li,L. Yang, S. Yan, M. Wang, D. Cheng, Q. Chen, Y. Dong, P Liu, W. Cai and C. Zhang, The Cu-MOF-199/single-walled carbon nanotubes modified electrode for simultaneous determination of hydroquinone and catechol with extended linear ranges and lower detection limits, Anal. Chim. Acta., 2015, 899, 57-65.
  • 45 Y. Wang, Y. Wu, J. Xie, H. Ge and X. Hu, Multi-walled carbon nanotubes and metal-organic framework nanocomposites as novel hybrid electrode materials for the determination of nano-molar levels of lead in a lab-on-valve format, Analyst, 2013,138,5113-5120.
  • 46 L. Fotouhi and M. Naseri, Recent electroanalytical studies of metal-organic frameworks: a mini-review, Crit. Rev. Anal. Chem., 2015,17, 1-9.
  • 47 N.A. Khan and S.H. Jhung, Synthesis of metal-organic frameworks (MOFs) with microwave or ultrasound: rapid reaction, phase-electivity, and size reduction, Coord. Chem. Rev., 2015, 285, 11-23.
  • 48 J. Gascon, S. Aguado and F. Kapteijn, Manufacture of dense coatings of Cu3(BTC)2 (HKUST-1) on a-alumina, Microporous Mesoporous Mater., 2008, 113, 132-138.
  • 49 Z.Q. Li, L.G. Qiu, T. Xu, Y. Wu, W. Wang, Z.Y. Wu and X. Jiang, Ultrasonic synthesis of the microporous metal-organic framework Cu3(BTC)2 at ambient temperature and pressure: an efficient and environmentally friendly method, Mater. Lett., 2009, 63, 78-80.
  • 50 X.J. Tian and J.F. Song, Catalytic action of copper (II) ion on electrochemical oxidation of metformine and voltammetric determination of metformine in pharmace, J. Pharm. Biomed. Anal., 2007, 44, 1192-1196.
  • 51 J.A. Mason, M. Veenstra and J.R. Long, Evaluating metal-organic frameworks for natural gas storage, Chem. Sci., 2014, 5, 32-51.
  • 52 D. Desai, B. Wong, Y. Huang, Q. Ye, D. Tang, H. Guo, M. Huang and P. Timmins, surfactant-mediated dissolution of metformin hydrochloride tablets: wetting effects versus ion pairs diffusivity, J. Pharm. Sci., 2014,103, 920-926.

Received 2 February 2016
Revised 10 March 2016
Accepted 8 April 2016

* To whom correspondence should be addressed. E-mail:

Correspondence

m.hadl@qom.ac.lr

Publication Dates

  • Publication in this collection
    22 Nov 2017
  • Date of issue

History

  • Received
    02 Feb 2016
  • Reviewed
    10 Mar 2016
  • Accepted
    08 Apr 2016
location_on
The South African Chemical Institute The South African Journal of Chemistry, University of the Witwatersrand, The Secretary - Laila Smith, School of Chemistry, Private Bag X3, Braamfontein, Johannesburg, ZA, 2050, Tel:+27 11 717 6705, 061 282 3477 - E-mail: editorsajchem@saci.co.za
rss_feed Acompañe los números de esta revista en su lector de RSS
Ir para arriba