Open-access An evidence-based guide to occlusion and articulation. Part 5: New roots: titanium and its influence on occlusion; and to cusp or not to cusp?

REVIEW
http://dx.doi.org/10.17159/2519-0105/2022/v77no5a4

An evidence-based guide to occlusion and articulation. Part 5: New roots: titanium and its influence on occlusion; and to cusp or not to cusp?

CP Owen

BDS, MScDent, MChD, FCD(SA), Professor Emeritus, Faculty of Health Sciences, University of the Witwatersrand Johannesburg, South Africa, ORCID: 0000-0002-9565-8010

Correspondence

SUMMARY AND PREAMBLE TO THE SERIES

Although this is essentially a review, It has not been written in the passive, third-person style normally associated with scientific writing, as it is intended to be thought-provoking and, hopefully, educational. It has therefore been written in more of a conversational style, and is aimed at students, dentists and dental technicians who are receptive to a slightly different view of occlusion and articulation, based on evidence.

Occlusion is a topic that has become a kind of archaic minefield of conflicting ideas, propositions, and above all, solutions, most of which are based on a complete lack of understanding of the evolution and development of teeth, and by extension, of clinically objective evidence.

That in itself is a statement of conflict (and perhaps even heretical), but it is by way of warning that this guide is not going to be much like anything you will find in standard text-books of dentistry or dental technology. It is, rather, an attempt to help you navigate through what you will read elsewhere, in the hope that eventually you will find an understanding that you can live with. It will appear as a sequential series in 7 Parts.

New roots: titanium and its influence on occlusion

Arguably the greatest advance in Prosthodontics was brought about by the successful integration of titanium implants into bone by Branemark and co-workers.123-5 A 2007 consensus report 6

But this is not intended to be a treatise on implant dentistry, but rather its relationship to occlusion. Whilst implant dentistry seems to be more common now in the partially edentulous jaw, implants were originally prescribed for the completely edentulous, and this falls into the "re-organised" approach as do complete dentures themselves. The options are a fixed prosthesis supported entirely by implants, or a removable overdenture prosthesis mostly supported by implants. The problem is not necessarily the implants themselves, but what we are putting on top of them, and if we do that as if the implants are teeth, we may have a problem.

Let's go back to the chewing cycle or rather the chewing envelope, under the influence of the central pattern generator, with its closing, contact and opening phases (see Parts 2 and 3). As the jaw closes, it is receiving afferent impulses from the muscles and joints, producing a rapid acceleration to tooth contact, which then initiates impulses from the tooth and periodontal ligament. This contact phase will provide feedback until the teeth have moved over each other (with a bolus of food in between) and as the jaw then moves from the chewing side to the non chewing side, this feedback reduces quickly, as do the afferents from the closing muscles and now the opening muscles are activated to move into the (slower) opening phase.

The feedback from the teeth and periodontal ligaments is rapid, which of course is a preventive mechanism should you encounter something too hard too quickly; if it's not fast enough, and the jaw doesn't open quickly enough, then damage to the tooth is likely. Chipped teeth, cracked teeth and even split teeth all can be the result.

If you are not sufficiently aware of all this, and have been brought up with a mechanistic view of how teeth come together, it is likely that you may not have subscribed to all the principles we have derived for conventional fixed prostheses (see Part 4), and your occlusal scheme may well be 'canine protected', based on the need to protect the other teeth in the arch. Even if it is a form of group function (as it should be) you would still be desperately trying to avoid balancing side contacts. And then if you want to get the best aesthetic result, you are likely to have used ceramics. My contention is that you are then most likely to see much chipping and cracking and breaking if this is the scheme you use on an implant supported prosthesis. Sadly, some recent reviews bear this out. A review of prosthetic complications from implant prostheses over a 16 year period 789 10

Feedback from implants is very poor, because it depends only on osseoperception, which takes some time to develop after acceptance of the foreign body that is the implant, and the appearance of neural endings near the implant-bone interface, 11

This has in fact been recognised, in a paper published in 2005, in one of the most prestigious implant journals, but which seems to have been largely ignored. The concern was that higher occlusal forces would lead to "implant overload" and peri-implant bone loss, as well as failure of the implants and prosthesis. 12

Which brings us to my next contention, which is why you do not need the beautiful occlusal surfaces that expert ceramicists create, and that exist in libraries of digital designs.

To cusp or not to cusp?

Whatever occlusal scheme you end up adopting, here is some of the evidence for keeping cusp angles low and grooves non-existent.

One of the first papers to be concerned with occlusal design (mainly because of its effects on implants) was a review from 1993. 1314Fig. 1). As the point of rotation of the tooth is approximately one third from the apex, the distance from the force vector to that point will determine the torqueing effect of the force because torque = the force multiplied by that distance.

If the cusp incline is now reduced (Fig. 2), the force remains the same, but the distance from the force vector line to the pint of rotation is reduced, thus reducing the torque: a 10 x reduction in cusp incline can result in a 30% reduction in torque.

The same principle applies to an implant-supported crown, only this time the point of rotation is considered to be at approximately the third thread (Fig. 3).

There have been a number of other papers since then that have looked at the effect of not only cusp angles but also enamel groove configuration on such aspects as the resistance of crowns to fracture and even the effect on the cervical area in terms of observed crown fractures and tooth abfraction. A seminal paper in 2011 used an analytic model to determine the influence of occlusal geometry on ceramic crown fracture by examining the role of cuspal inclines and fissure radius. 15Fig. 4 for example shows the correlation between cusp angle and fracture load.

Fig. 4

From this model they recommended that cusp angles should be no greater than 25° and grooves and fissures should be wide and shallow, as the fracture resistance will be affected by the combined effect of cusp angle and fissure radius which may predict the fracture resistance of all-ceramic crowns.

Similar findings were found in a finite element analysis (FEA) study using tooth enamel data 16

There is an argument that when replacing only one or two crowns in an unworn dentition that the occlusal morphology of that dentition should be retained, but that argument is based more on a perceived aesthetic need to make everything look the same; but from a functional point of view it is really not desirable, and hardly ever necessary. However, if it is considered necessary to have cusp angels of greater than 20 or 25°, then you should be using a material that will hopefully be strong enough or thick enough to resist fracture. In fact this has been tested, again using an FEA model and a simple occlusal morphology of either a V-shape or U-shaped fissure, and varying the occlusal thickness and ceramic material. 17Fig. 5. The steeper angles concentrated the stress in the fissure area and the flatter cusps eliminated that and distributed the stress more widely. The conclusions were again similar: for the ceramic monolithic materials, a design with a rounded occlusal notch, 20° cusp angle and medium thickness (1.5 mm occlusal) was considered optimal in terms of tooth conservation and fracture resistance.

Fig. 5

So when you see beautiful ceramic work such as in Fig. 6 and then measure the cusp angles as in Fig. 7, and look at the intricate occlusal fissuring, think about how this is going to function in the mouth. May look pretty, but it could be pretty liable to chipping and fracture under function.Finally, if you are not convinced, or even if you are, some additional evidence comes from the study of abfraction, or non-carious cervical lesions (NCCL). One study used a combination of FEA and strain gauges on artificial teeth, and found that oblique loads to the cusps resulted in tensile stresses in the cervical lesion and concluded that the pattern of stress coincided with the clinical appearance of an NCCL.18 19

A more recent study from the world of Physical Anthropology looked at the stress distribution of unworn and worn teeth using three dimensional FEA. 20 Fig. 8 shows the tensile stress values at nodes along the buccal cervical region for the same tooth with unworn cusps and with a worn occlusal surface.

So finally (again) I hope you are now convinced that cusps, although friendly to aesthetics, are the enemy of occlusal freedom, so there needs to be an understanding of how to retain looks with freedom. To return to the title of this section, and with tongue firmly in cheek, I leave you with an alternative to the first few lines of Shakespeare's famous soliloquy:

REFERENCES

  • 1. Branemark PI, Hansson BO, Adell R, Breine U, Lindstrom J, Hallen O, et al. Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period. Scand J Plast Reconstr Surg Suppl. 1977; 16: 1-132.
  • 2. Zarb GA. Implantomania: prosthodontics at a crossroads. Int J Prosthodont. 2012; 25(2): 180-5.
  • 3. Lindhe J, Pacey L. 'There is an overuse of implants in the world and an underuse of teeth as targets for treatment' Br Dent J. 2014; 217(8): 396-7. doi: 10.1038/ sj.bdj.2014.930.
    » https://doi.org/10.1038/ sj.bdj.2014.930
  • 4. Giannobile WV, Lang NP. J Are Dental Implants a Panacea or Should We Better Strive to Save Teeth? J Dent Res. 2016; 95(1): 5-6
  • 5. Zarb GA, Hobkirk JA. On Implant Prosthodontics: One Narrative, Twelve Voices - Introduction. Int J Prosthodont. 2018; 31 Suppl: s6-s8. doi: 10.11607/ijp.2018.suppl.e.
    » https://doi.org/10.11607/ijp.2018.suppl.e
  • 6. Lang NP, Muller F, Working Group I. Epidemiology and oral function associated with tooth loss and prosthetic dental restorations. Consensus report of Working Group I. Clin Oral Implants Res 2007; 18 Suppl 3: 46-9 doi: 10.1111/j.1600-0501.2007.01437.x.
    » https://doi.org/10.1111/j.1600-0501.2007.01437.x
  • 7. Goodacre BJ, Goodacre SE, Goodacre CJ. Prosthetic complications with implant prostheses (2001-2017). Eur J Oral Implantol. 2018; 11 Suppl 1: S27-S36.
  • 8. Pieralli S, Kohal RJ, Rabel K, von Stein-Lausnitz M, Vach K, Spies BC. Clinical outcomes of partial and full-arch all-ceramic implant-supported fixed dental prostheses. A systematic review and meta-analysis. Clin Oral Implants Res. 2018; 29 Suppl 18: 224-236. doi: 10.1111/clr.13345.
    » https://doi.org/10.1111/clr.13345
  • 9. Papaspyridakos P, Bordin TB, Natto ZS, El-Rafie K, Pagni SE, Chochlidakis K, et al Complications and survival rates of 55 metal-ceramic implant-supported fixed complete-arch prostheses: A cohort study with mean 5-year follow-up. J Prosthet Dent. 2019; 122(5): 441-449. doi: 0.1016/j.prosdent.2019.01.022.
    » https://doi.org/0.1016/j.prosdent.2019.01.022
  • 10. Papaspyridakos P, Bordin TB, Kim YJ, El-Rafie K, Pagni SE, Natto ZS et al. Technical Complications and Prosthesis Survival Rates with Implant-Supported Fixed Complete Dental Prostheses: A Retrospective Study with 1- to 12-Year Follow-Up. J Prosthodont. 2020; 29(1): 3-11. doi: 10.1111/jopr.13119.
    » https://doi.org/10.1111/jopr.13119
  • 11. Abarca M, Van Steenberghe D, Malevez C, Jacobs R. The neurophysiology of osseointegrated oral implants. A clinically underestimated aspect. J Oral Rehabil 2006; 33: 161-9. doi: 10.1111/j.1365-2842.2005.01556.x.
    » https://doi.org/10.1111/j.1365-2842.2005.01556.x
  • 12. Kim Y, Oh T-J, Misch CE, Wang H-L. Occlusal considerations in implant therapy: clinical guidelines with biomechanical rationale. Clin Oral Implants Res. 2005; 16(1): 26-35. doi: 10.1111/j.1600-0501.2004.01067.x.
    » https://doi.org/10.1111/j.1600-0501.2004.01067.x
  • 13. Weinberg LA. The biomechanics of force distribution in implant-supported prostheses. Int J Oral Maxillofac Implants 1993; 8(1): 19-31.
  • 14. Weinberg LA. Therapeutic biomechanics concepts and clinical procedures to reduce implant loading. Part I. J Oral Implantol. 2001; 27(6): 293-301. doi: 10.1563/15481336(2001)027<0293:TBCACP>2.3.CO;2.
    » https://doi.org/10.1563/15481336(2001)027<0293:TBCACP&gt;2.3.CO;2
  • 15. Sornsuwan T, Swain MV. Influence of occlusal geometry on ceramic crown fracture; role of cusp angle and fissure radius. J Mech Behav Biomed Mater. 2011; 4(7): 1057-66. doi: 10.1016/j.jmbbm.2011.03.014
    » https://doi.org/10.1016/j.jmbbm.2011.03.014
  • 16. Wan B, Shahmoradi M, Zhang Z, Shibata Y, Sarraf-pour B, Swain M, et al. Modelling of stress distribution and fracture in dental occlusal fissures. Sci Rep. 2019; 9(1): 4682. doi: 10.1038/s41598-019-41304-z.
    » https://doi.org/10.1038/s41598-019-41304-z
  • 17. Shahmoradi M, Wan B, Zhang Z, Wilson T, Swain M, Li Q. Monolithic crowns fracture analysis: The effect of material properties, cusp angle and crown thickness. Dent Mater. 2020; 36(8): 1038-1051. doi: 10.1016/j.dental.2020.04.022.
    » https://doi.org/10.1016/j.dental.2020.04.022
  • 18. Palamara D, Palamara JE, Tyas MJ, Messer HH.Strain patterns in cervical enamel of teeth subjected to occlusal loading. Dent Mater. 2000; 16(6): 412-9. doi: 10.1016/s0109-5641(00)00036-1.
    » https://doi.org/10.1016/s0109-5641(00)00036-1
  • 19. Kuroe T, Itoh H, Caputo AA, Konuma M. Biomechan-ics of cervical tooth structure lesions and their restoration. Quintessence Int. 2000; 31(4): 267-74.
  • 20. Benazzi S, Nguyen HN, Kullmer O, Hublin J. Unravelling the Functional Biomechanics of Dental Features and Tooth Wear. PLoS ONE 2013; 8(7): e69990. doi:10.1371/journal.pone.0069990
    » https://doi.org/10.1371/journal.pone.0069990

Correspondence:
CP Owen
Professor Emeritus, Faculty of Health Sciences, University of the Witwatersrand
Johannesburg, South Africa
Email:

Correspondence

peter.owen@wits.ac.za Cell: +27 83 679 2205

Publication Dates

  • Publication in this collection
    13 Oct 2022
  • Date of issue
location_on
The South African Dental Association (SADA) The South African Dental Association (SADA), Private Bag 1, Houghton, Johannesburg, Gauteng, ZA, 2041, Tel: +27 11 530 6520 - E-mail: nmojela@sada.co.za
rss_feed Stay informed of issues for this journal through your RSS reader
Go to top