Open-access Sterilisation and single-use of endodontic files - a short report

Abstract

INTRODUCTION: In many countries, endodontic files continue to be sterilised and reused in multiple clinical cases as the alternative of single-use of these instruments is avoided due to financial reasons. METHODS: A survey was performed including South African general dental practitioners and specialist prosthodontists to determine the current endodontic file sterilisation methods in place and the adoption rate of single-use protocols of both hand and engine-driven instruments. RESULTS: The majority of respondents (76.6%, n=141/184) indicated autoclaving endodontic files prior to reuse. Almost a quarter of the respondents (23.4%, (n=43/184) used only cold sterilisation. Some respondents (2,8%, n=5/181) indicated not sterilising their files at all. A low number of respondents had adopted the single-use of endodontic hand files (10.9%, n=20/184). Engine-driven files were used only once and discarded by 18.5% (n=34/184) of respondents. CONCLUSION: It appears that, at times, acceptable infection prevention and control practices regarding the sterilisation these instruments are not necessarily being adhered to. The adoption of single-use protocols of endodontic files in a South African dental setting is higher than previously reported.

Endodontic files; single-use; sterilisation; survey


INTRODUCTION

In modern dental practice, both hand and engine-driven endodontic files are used for cleaning and shaping procedures of root canal treatment. During this process, these instruments become contaminated with microorganisms and appropriate cross-contamination and sterilisation procedures are necessary if endodontic files are to be reused on multiple cases.1

Whilst it is common practice to reprocess many dental instruments, the intricate designs of some make effective cleaning and sterilising a challenge. For this reason several instruments are considered disposable or single-use items.2

Previous authors have supported the recommendation for the single-use of both hand and rotary endodontic files due to the inability to adequately reprocess these instruments,2-4 however this view has been debated.5

It has been previously reported that infection prevention and control practices in a South African dental setting may at times be inadequate.6,7 The sterilisation methods used by South African dental practitioners specifically for the reprocessing of endodontic files is currently unclear.

Furthermore, the proportion of South African practitioners who have adopted single-use protocols, pertaining only to endodontic hand files, has only been previously reported on in one major city.8

This study aimed to determine the sterilisation methods used by South African dental practitioners in the reprocessing of both engine-driven as well as endodontic hand files, and to quantify the proportion of practitioners who practice single-use of these instruments.

MATERIALS AND METHODS

A cross-sectional, observational study was conducted. A multiple-choice survey was designed using an online program (Qualtrics, Provo, Utah) and electronically mailed to 61 members of the Academy of Prosthodontics, South Africa (APSA) and 3191 South African General Dental Practitioners (GDPs) registered in the South African Dental Association (SADA) database.

The survey was circulated on social media platforms to increase visibility to the target groups. A quantitative design consisting of questions with multiple-choice answers was completed by participants. The questions included:

• Demographic information.

• Sterilisation methods used for endodontic instruments.

• Sterilisation conducted prior to first use of new files.

• Sterilisation conducted prior to re-use.

• Single-use of endodontic hand files.

• Single-use of engine-driven files.

Data was collected and exported as comma-separated values (CSV file format) for evaluation in Microsoft Excel 2016, analysed and expressed as simple percentages of the total number of respondents.

Only private practice GDPs and SPs routinely performing endodontic treatment were included in this investigation. GDPs and SPs not engaged in the clinical practice of endodontics and those employed outside of a private practice setting, such as community-service (a compulsory internship year in South Africa), public-sector dentists and full-time academics were excluded.

The research proposal for this study was approved by the Faculty of Health Sciences Research Ethics Committee, University of Pretoria (Protocol number 331/2018).

RESULTS

An electronic mail containing a link to the survey was sent to both APSA members (n=61) and SADA members (n=3191). In total, 215 responses were returned by the cut-off date. The overall response rate was 6.6% of the total number surveyed (n = 215/3252).

Almost ten percent of the total respondents (9.7%, n=21/215) indicated not performing private practice endodontic treatment and were excluded. Another respondent provided irrational answers to several questions and was therefore ruled out for inclusion. Analysis was subsequently performed on the valid responses provided by the remaining 193 participants (89.8% of total respondents).

Demographics

Of the 193 participants, 46.1% (n = 89) were male and 53.9% (n=104) were female. Eleven participants (5.7%, n=11/193) were SPs and the remainder were GDPs (94.3%, n=182). A wide distribution was found in relation to age and number of years of experience. All South African provinces were represented.

Sterilisation methods used for endodontic files

Only two sterilisation methods were reportedly used for the reprocessing of endodontic files. More than three-quarters of the respondents (76.6%, n=141/184) indicated sterilising files using a steam autoclave.

Cold sterilant solutions were used by almost one-quarter of the respondents (23.4%, n=43/184). Nine respondents practiced single-use of endodontic files and were excluded from analysis as they did not sterilise and reprocess files.

Sterilisation before first use

With regards to initial sterilisation procedures (i.e. when removing endodontic files from the manufacturer's packaging), the majority of respondents (71.5%, n=139/193) indicated that they did not sterilise endodontic files prior to first patient use. The remaining 28.5% (n=55/193) indicated completing a pre-use sterilisation cycle.

Sterilisation before re-use

Almost all the respondents who reused their endodontic files (97,2%, n=176/181) indicated routinely sterilising the files prior to re-use on subsequent cases. A small number (2,8%, n=5/181) indicated the opposite.

Twelve respondents (n=12/193) did not answer this question as they practiced either single-use of their files or did not sterilise endodontic files (or a combination of these reasons).

Single-use of endodontic hand files

Only 10.9% (n=20/184) of respondents reported practising single-use of endodontic hand files. The remaining 89.1% (n=164/184) reused hand files on multiple cases following reprocessing procedures. Nine respondents did not answer this question as they indicated not using hand files routinely.

Single-use of engine-driven files

Rotary and reciprocating files were reprocessed and reused on multiple cases by the majority of respondents (81.5%, n=150/184).

The remaining respondents (18.5%, n=34/184) indicated practicing single-use of these instruments. Nine respondents did not answer this question as they did not use engine-driven files routinely.

DISCUSSION

Although the overall response rate of this survey was low, the response rate was in line with previous South African survey findings conducted on similar cohorts.9 10

A previous study reported that the single-use of endodontic flies had not been adopted by any general dental practitioners surveyed in one major South African city.8

The philosophy regarding single-use of endodontic instruments originated in the United Kingdom in response to concerns surrounding the potential spread of prion disease11251228

When any dental instruments are to be reused, they must be both thoroughly cleaned of bioburden and sterilised to prevent cross-contamination between patients. Although sterilisation may be achieved by several different methods, semi-critical and critical instruments - such as en-dodontic files - should be sterilised by autoclave.132

Previous investigations have demonstrated that endodontic files and burs are not sterile at the time of purchase and that sterilisation should be performed prior to first use.4

In recent times, however, manufacturers have created pre-sterilised, single-use endodontic instruments which do not need to be sterilised prior to initial use.14

The finding that nearly one quarter of respondents continue to use cold sterilisation as the sole means of reprocessing endodontic files was disappointing. Placement of endodontic files in cold sterilant solutions, such as glutaraldehyde, has been demonstrated to be inferior to steam methods and is no longer recommended as a primary means for the sterilisation of endodontic files.13

Additionally, it has been demonstrated that cold sterilising solutions, such as glutaraldehyde, may take up to ten hours to sterilise an instrument.15

CONCLUSION

Within the limitations of this study, the majority of South African GDPs and SPs were demonstrated to reuse endodontic files on multiple clinical cases following reprocessing procedures. A large number of respondents used acceptable methods of sterilisation for reprocessing endodontic files. A significant proportion however continue to use unacceptable methods such as cold sterilisation with glutaraldehyde solution.

Whilst only a limited number of South African dental practitioners have adopted the routine practice of single-use of both engine-driven and hand endodontic files, this number is higher than previously reported.

Declaration

The Author(s) declare that there is no conflict of interest.

Funding

This research did not receive any specific grant from funding agencies in the public, commercial, or not-for-profit sectors.

References

  • 1. Carrotte P. Endodontics: Part 5. Basic instruments and materials for root canal treatment. Br Dent J. 2004; 197(8): 45-64.
  • 2. Walker JT, Dickinson J, Sutton JM, Raven NDH, Marsh PD. Cleanability of dental instruments - implications of residual protein and risks from Creutzfeldt-Jakob disease. Br Dent J. 2007; 203(7): 395-401.
  • 3. Letters S, Smith A, McHugh S, Bagg J. A study of visual and blood contamination on reprocessed endodontic files from general dental practice. Br Dent J. 2005; 199(8): 522-25.
  • 4. Morrison A, Conrod S. Dental burs and endodontic files: are routine sterilization procedures effective? J Can Dent Assoc. 2009; 75(1): 39.
  • 5. Messer H, Parashos P, Moule A. Should Endodontic Files Be Single-Use Only? A Position Paper From The Australian And New Zealand Academy of Endodontists. Aust Endod J. 2003; 29(3): 143-5.
  • 6. Mehtar S, Shisana O, Mosala T, Dunbar R. Infection control practices in public dental care services: findings from one South African Province. J Hosp Infect. 2007; 66(1): 65-70.
  • 7. Buchanan GD, Warren N, Gamieldien MY. Debris contamination of endodontic hand files in dental practice. S Afr Dent J. 2018; 73(6): 440-4.
  • 8. Buchanan GD, Warren N. Single-use of endodontic hand files: perceptions and practise. J Infect Prev. 2019; 20(1): 32-6.
  • 9. Snyman L, van der Berg-Cloete S, White J. The perceptions of South African dentists on strategic management to ensure a viable dental practice. S Afr Dent J. 2016; 71(1): 12-8.
  • 10. Fernandes NA, Herbst D, Postma TC, Bunn BK. The prevalence of second canals in the mesiobuccal root of maxillary molars: A cone beam computed tomography study. Aust Endod J. 2018; 1 -5.
  • 11. Head MW, Ritchie D, McLoughlin V, Ironside JW. Investigation of PrPres in dental tissues in variant CJD. Br Dent J. 2003; 195(6): 339-43.
  • 12. Yared G. In vitro study of the torsional properties of new and used profile nickel titanium rotary files. J Endod 2004; 30(6): 410-2.
  • 13. Hurtt CA, Rossman LE. The sterilization of endodontic hand files. J Endod. 1996; 22(6): 321-2.
  • 14. Webber J. Shaping canals with confidence: WaveOne Gold single-file recipocating system. Roots. 2015; 1(3): 34-40.
  • 15. Özalp N, Ökte Z, Özcelik B. The Rapid Sterilization of Gutta-Percha Cones with Sodium Hypochlorite and Glutaraldehyde. J Endod. 2006; 32(12): 1202-4.

Correspondence:
Glynn D Buchanan
Oral and Dental Hospital
31 Bophelo Road, Prinshof Campus, Riviera,
Pretoria, 0002, South Africa.
Email:

Author contributions:
All authors have contributed significantly and are in agreement with the manuscript.
1 . Glynn D Buchanan: Conceived the study, wrote, reviewed and edited the manuscript - 40%
2 . Mohamed Y Gamieldien: Conceived the study and wrote, reviewed and edited the manuscript - 30%
3 . Sheree Tredoux: Conceived the study and wrote, reviewed and edited the manuscript - 20%
4 . Nichola Warren: Conceived the study and wrote, reviewed and edited the manuscript - 10%

Correspondence

glynn.buchanan@up.ac.za

Publication Dates

  • Publication in this collection
    19 Aug 2020
  • Date of issue
location_on
The South African Dental Association (SADA) The South African Dental Association (SADA), Private Bag 1, Houghton, Johannesburg, Gauteng, ZA, 2041, Tel: +27 11 530 6520 - E-mail: nmojela@sada.co.za
rss_feed Stay informed of issues for this journal through your RSS reader
Go to top