Open-access An in-vitro comparison of microleakage between three calcium silicate cements and amalgam

Abstract

AIM: The purpose of this in-vitro study was to compare the sealing ability of White ProRoot® MTA, MTA Plus™, BiodentineTM and Permite Amalgam when used as root-end filling materials. MATERIALS AND METHODS: 120 single rooted, extracted teeth were endodontically treated. The apical 3 mm of each root was resected, and 3 mm deep root-end cavities were prepared. Specimens were divided into four groups (n=30) and filled with the following materials: ProRoot® MTA, MTA Plus™, Biodentine™, and Permite Amalgam. Specimens were submerged in Indian Ink for 48 hours, and sectioned horizontally in one millimetre increments from the apical end. Dye penetration was measured using a stereomicroscope. RESULTS: Data for different groups was summarised as percentages. Pairwise comparisons between the calcium silicate materials to amalgam were done at the 0.017 level of significance, using Fisher's exact test. Amalgam showed significantly more leakage than the calcium silicate materials (ProRoot® MTA, MTA PlusTM and Biodenti-neTM) (p<0.001). No significant differences in sealing ability were found among the calcium silicate materials. CONCLUSION: Amalgam should be regarded as unsuitable for use as a root-end filling material. Calcium silicate cements should be recommended as the material of choice for root-end filling.


INTRODUCTION

Periapical endodontic surgery may be indicated when orthograde retreatment of failed endodontic therapy is unsuccessful, not feasible or contraindicated.123

The ideal root-end filling material should be: non-toxic, non-carcinogenic, non-corrosive, non-staining to periapical tissues, biocompatible with host tissues, able to stimulate the regeneration of the periodontium, insoluble, dimensionally stable, unaffected by moisture, adherent to dentine, radiopaque, easy to use, and have a long shelf life.3-5 Various materials have been suggested and tested in the quest to fulfil all these ideal requirements. Amongst those proposed are: amalgam, gutta-percha, Cavit (3M ESPE, St Paul, Minnesota, USA), glass-ionomer cement, IRM (Dentsply/Maillefer, Ballaigues, Switzerland), Super EBA (Harry J. Bosworth Co., Skokie, Illinois, USA), composite resin, compomer, gold foil, Diaket (3M/ESPE, Seefeld, Germany), polycarboxylate cements, and more recently Mineral Trioxide Aggregate (MTA).3

Dental amalgam was first used as a root-end filling material by Farrar in 1884,673,6 The disadvantages include: initial microleakage891071112373® MTA (Dentsply/Maillefer, Ballaigues, Switzerland) was developed for use as a root-end filling material at Loma Linda University by Professor Mahmoud Torabinejad and colleagues in the early 1990's.13,14 The first description of MTA appeared in the scientific literature in 1993. In 1998 the United States Food and Drug Administration (FDA) approved MTA for use in endodontic treatment.13,1516 Mineral Trioxide Aggregate can be described as a hydraulic cement, for it setting is primarily dependant on hydration reactions and once set it is stable underwater.1717181717,18

According to the patent, ProRoot® MTA is a Type 1, ordinary Portland cement.14,19205® MTA results in the formation of calcium hydroxide and a calcium silicate hydrate gel, and this solidifies in approximately 165 minutes.5,20® MTA were introduced to the market in 1998 and 2002 respectively.21® MTA.13,22

The novel MTA material, MTA PlusTM (Prevest Denpro Limited, Jamu, India) has a finer particle size than ProRoot® MTA.23TM kit contains a powder and is supplied with a proprietary salt-free polymer gel and water, either one of which can be used as mixing components.24 24,2526,27 As it is necessary to irrigate the osteotomy site prior to closing a periapical flap to avoid complications,252525

An X-ray diffraction analysis of the unhydrated powder of MTA PlusTM demonstrates that its components are tricalcium silicate, dicalcium silicate and bismuth oxide.28TM powder with the anti-washout gel or water, calcium silicate hydrate forms.2824 TM when mixed with water took 65 minutes longer to set than when MTA PlusTM was mixed with the anti-washout gel (180 vs 115 minutes).28

Since January 2011, Biodentine™ a synthetic tricalcium silicate based cement has been commercially available and is marketed as a 'bioactive dentine substitute'.29,30 TM is based on 'Active Biosilicate TechnologyTM', which results in the production of pure tricalcium silicate that is free of metallic impurities.31323131333235

Microleakage can be defined as the passage of bacteria, fluids and chemical substances between the root canal filling material and the tooth.3637

The purpose of this in-vitro study was to compare the sealing abilities of White ProRoot® MTA, MTA Plus™, Biodentine™ and Permite Amalgam when used as root-end filling materials.

MATERIALS AND METHODS

One hundred and twenty single-rooted extracted human teeth were collected from the out-patient dental extraction clinic of the Oral and Dental Hospital, School of Dentistry, Faculty of Health Sciences, University of Pretoria. Every aspect of this research project was conducted in line with the ethical and safety standards for handling human tissues and conducting laboratory research, as prescribed by South African law: the Health Profession Act 56 of 1974 (South African National Health Bill, 2003). The study was approved by the Research Ethics Committee, Faculty of Health Sciences, University of Pretoria, under protocol number 138/2011.

The teeth were stored immediately after extraction in phosphate buffered saline (PBS) (Sigma-Aldrich, Johannesburg, South Africa) at room temperature. The experiments were conducted two weeks later. The prerequisites for the sample selection were similar to those used by Pichardo et al. (2006)38

1. Root formation should be complete.

2. There should be a single, straight root canal

3. No root canal therapy should have been previously performed on the teeth.

4. The teeth should not have any fractures.

5. There should be no root caries or root resorption.

All the above-mentioned properties were verified radio-graphically except for the absence of fractures (point 4), which was done using a surgical operating microscope (D.F. Vasconcellos, Säo Paulo, Brazil).

The crowns of all teeth were sectioned with a flat-ended, cylindrical diamond bur (Komet, Lemgo, Germany) driven in a high speed hand piece (W&H, Bürmoos, Austria). The bur was held perpendicular to the long axis of the tooth and the cut made to render a standard root measurement of 18mm, as suggested by Pichardo et al. 2006.38

All the root canals were prepared to within 0.5mm of the apical foramen with ProTaper Universal (Dentsply/Maillefer, Ballaigues, Switzerland) rotary instruments using the X-Smart Plus rotary motor (Dentsply/Maillefer, Ballaigues, Switzerland), according to the manufacturer's instructions. A size 15 k-file (Dentsply/Maillefer, Ballaigues, Switzerland) was used to establish patency of the root canals. Glyde Root Canal Conditioner (Dentsply/Maillefer, Ballaigues, Switzerland) was used as a lubricant on the files prior to insertion into the canals. A 6% sodium hypochlorite solution (Nordiska Dental, Angelholm, Sweden) was used for irrigation between rotary instrumentation. The canals were prepared with ProTaper Universal rotary files (Dentsply/ Maillefer, Ballaigues, Switzerland), up to a size F3 instrument. A final irrigation of the canals was performed with 17% EDTA (Topclear, Dental Discounts, Johannesburg, South Africa). The canals were dried with F3 ProTaper Paper Points (Dentsply/Maillefer, Ballaigues, Switzerland). All the prepared root canals were obturated by applying the continuous wave, warm vertical condensation technique using the Calamus Dual Obturation Unit (Dentsply/Maillefer, Ballaigues, Switzerland). The coronal access cavities were sealed with Fuji IX glass-ionomer restorative material (GC Corporation, Tokyo, Japan). The specimens were then stored in a single sterile plastic container filled with PBS solution at room temperature for 48 hours.

The apical 3mms of all the specimens were resected perpendicular to the long axis of the tooth using a straight carbide fissure bur (Komet, Lemgo, Germany) on a high speed hand-piece. Root-end cavities were prepared on all specimens to a depth of 3mm using an ultrasonic ProUltra Surgical Tip (Dentsply/Maillefer, Ballaigues, Switzerland) on an NSK Ultrasonic Scaler Unit (NSK, Nakanishi, Japan). The ultrasonic tip was used in a brushing motion with light pressure, and a cylindrical cavity was created parallel to the long axis of the root.

The entire surface of every specimen, except for the resected apical portion, was coated with two layers of clear nail varnish to seal all other possible portals of communication with the root canal.

The 120 specimens were randomly divided into four groups (n=30) and treated as follows:

Group 1: White ProRoot® MTA (Dentsply/Maillefer, Ballaigues, switzerland) (n=30)

The material was hand-mixed according to the manufacturer's instructions and placed into the root-end cavity preparation, using the MAP system (micro apical placement) (Dentsply/Maillefer, Ballaigues, Switzerland).

Group 2: MTA plus™ (prevest Denpro Ltd., Jamu, India) (n=30)

The material was hand mixed according to the manufacturer's instructions and placed into the root-end cavity preparation, using the MAP system (Dentsply/Maillefer, Ballaigues, Switzerland).

Group 3: Biodentine™ (septodont Ltd., saint Maur des Fausse's, France) (n=30)

The material was mixed in an amalgamator (TPC Advanced Technology, California, USA) according to the manufacturer's instructions and placed into the root-end cavity preparation, using the MAP System (Dentsply/ Maillefer, Ballaigues, Switzerland).

Group 4: Amalgam (Permite, SDI, Victoria, Australia) (n=30)

The material was mixed in an amalgamator (TPC Advanced Technology, California, USA) according to the manufacturer's instructions and placed into the root-end cavity preparation, using a retrograde amalgam carrier (Medesy, Pordenone, Italy).

Each group of specimens was wrapped in gauze that had been moistened with PBS, and stored in separate, sealed, sterile plastic containers. The specimens were then placed in an incubator (Binder, Tuttlingen, Germany), and stored for 24 hours at 37°C to allow the materials to set completely.

The specimen groups were then immersed in Indian Ink dye (Winsor and Newton, London, England), and remained immersed in their individual, sealed, sterile plastic containers for 48 hours at 37°C. The specimens were then removed from the dye reservoir, and excess dye was rinsed off with distilled water for 15 minutes. The apical end of each specimen was sectioned transversely in 1mm increments with a wafering blade in an IsometTM low speed saw (Buehler, Lake Bluff, Illinois, USA) under continuous water irrigation. This rendered three 1mm slices of each root-end which were then packaged in labelled, sealed packets, identifying each sample as being: 1mm, 2mm or 3mm from the apex.

The sections were then mounted on microscopic glass slides, and examined under a stereomicroscope (Carl Zeiss, Jena, Germany) by two independent, blinded and calibrated examiners. The extent of dye penetration was measured to the nearest millimetre based on the presence of visible dye between the root-end filling and dentinal wall interface.

Data was summarized in terms of percentage for the outcome vector (no leak; 1mm leak; 2mm leak; 3mm leak). Furthermore, pairwise comparisons between each of the new generation filling materials and amalgam were done at the 0.017 level of significance using Fisher's exact test. The latter test could also be used at the 0.05 level of significance to assess the four filling materials in a single analysis.

RESULTS

The measurement of the depth of dye penetration between the root-end filling material and the dentinal wall interface was of note.

Group 1: Dye penetration of White ProRoot® MTA specimens

In this group, 26 specimens showed no leakage, four specimens leaked to a depth of 1mm and only three specimens leaked to a depth of 2mm (Figure 1a).

Group 2: Dye penetration of MTA PlusTM specimens

Twenty two of the specimens in this group showed no leakage, eight specimens leaked to a depth of 1mm, and three specimens leaked to a depth of 2mm (Figure 2a).

Group 3: Dye penetration of Biodentine™ specimens

No leakage was observed in 24 specimens of this group, six specimens leaked to a depth of 1mm, and four specimens leaked to a depth of 2mm (Figure 3a).

Group 4: Dye penetration of Permite Amalgam specimens

All 30 of the specimens in this group showed leakage to a depth of 1mm, 27 specimens leaked to a depth of 2mm, and 12 specimens leaked to a depth of 3mm (Figure 4a).

The results of all the specimens from the different groups combined before statistical analysis are illustrated by Figure 2. The specimens from the Permite Amalgam group showed the most leakage while the White ProRoot® MTA group showed the least amount of leakage.

Statistical analysis

The outcomes of the failure vector are reported for each treatment group in Figure 3. Amalgam displayed significantly greater leakage than any of the calcium silicate root-end filling materials (ProRoot® MTA, MTA PlusTM and BiodentineTM).

The differences are very clear if the leakage outcome is simplified as present or absent. Then it can be noted that leakage of the amalgam samples was 100% (30/30), and that 20% (6/30) of BiodentineTM samples, 13.3% (4/30) of ProRoot® MTA samples while 27.6% (8/30) of MTA PlusTM samples leaked. It is also important to note that none of the calcium silicate retrograde-filled teeth demonstrated leakage up to 3mm. In contrast, 40% (12/30) of the amalgam-filled teeth showed leakage up to the 3mm level.

Furthermore, no significant differences were found among the calcium silicate cements, namely BiodentineTM vs. ProRoot® MTA (p = 0.776), BiodentineTM vs. MTA PlusTM (p=0.667), and ProRoot® MTA vs. MTA PlusTM (p = 0.350).

DISCUSSION

The purpose of this in-vitro study was to compare the sealing ability of root-end fillings. White ProRoot® MTA, MTA PlusTM, BiodentineTM and Permite Amalgam were compared by measuring the linear dye penetration of Indian ink dye at the interface between the root-end filling and the dentinal wall. The achievement of a hermetic seal by a root-end filling is a critical factor that impacts on the long-term success of endodontic surgery.37

Microleakage is an estimate of the quality of the seal, and can be measured by allowing a tracer to penetrate a filled root-end cavity.393939,40 This technique is a passive method that depends on the phenomenon of capillarity, whereby the dye penetrates any space between the root-end filling and the canal wall.39,41et al. (1994), a filling material able to resist the penetration of small molecules such as dye, would have the potential to resist the penetration of larger bacteria and their by-products.424043 et al. (1995) compared the penetration of tracers and other assessment methods of the efficacy of the sealing of root-end fillings. The findings of their experiments showed that bacterial penetration and Indian ink dye penetration yielded similar results.44

In the present study, White ProRoot® MTA, MTA Plus™ and BiodentineTM showed significantly better sealing ability when compared with Permite Amalgam. There were no statistically significant differences in sealing ability between the three calcium silicate cements.

Amalgam has been considered as the material of choice for root-end filling for over a century, despite the many disadvantages of its use.7488,45 Vertucci and Beatty (1986), however, found no significant difference in apical dye penetration, whether cavity varnish was used or not.4646et al. (1983) found that corrosion products start to occupy the gap between amalgam and dentine within seven days.8 947

ProRoot® MTA was found to have a significantly superior sealing ability to amalgam in the present study. The application of MTA in endodontics was first investigated in 199315484242

Mineral Trioxide Aggregate was found to have a superior seal to amalgam and Super EBA by Aqrabawi (2000), when the penetration of 1% methylene blue dye was measured on longitudinally sectioned samples.49et al. (2003), measured the linear penetration of Indian ink dye in teeth that had been decalcified, rendering them transparent.50 et al (2003) as root-end fillings after the root-end cavities were irrigated with saline, citric acid or doxycycline. It was found that amalgam leaked significantly more than MTA and Super EBA, irrespective of the irrigant used, but there was no statistically significant difference in leakage between MTA and Super EBA.50515137

BiodentineTM and MTA PlusTM are relatively new calcium silicate materials. The current study is the first to investigate the sealing ability of MTA PlusTM as a root end filling. Kokate and Pawar (2012), compared the efficacy of the marginal seals of BiodentineTM, MTA and glass ionomer cement in root-end fillings, by examining the penetration of 1% Methylene blue in longitudinally sectioned samples with stereomicroscopy.52TM displayed significantly less leakage than MTA and glassionomer cement, with glass-ionomer cement exhibiting the most microleakage.52et al. (2014) examined the marginal adaptation of BiodentineTM, MTA and glass-ionomer cement as root-end fillings by measuring the area stained by Rhodamine blue dye in transverse sections using confocal laser scanning microscopy.53

The study revealed that BiodentineTM showed the lowest marginal gaps and the best marginal adaptation, followed by MTA. The largest marginal gaps were found with glassionomer cement. The results of the present study differ from those of Kokate and Parwar (2012)52et al. (2014),53TM and MTA. A possible reason for the different outcome could be related to the sample size of the previous studies. Both used a sample size of 10 specimens per group while in the present study, 30 specimens were used per group. Other possible differences may be attributed to the fact that different types of dyes were used. Furthermore, Kokate and Pawar (2012) sectioned their specimens longitudinally while in the present study, specimens were sectioned transversely.52et al. (2014) used confocal laser scanning microscopy to assess the specimens while in the present study stereomicroscopy was used.53

The phenomenon of hydroxyapatite formation over MTA, MTA PlusTM and BiodentineTM when immersed in simulated body fluids such as PBS is well documented.24,34247

In the clinical scenario, MTA PlusTM and BiodentineTM may have certain advantages over ProRoot® MTA. MTA PlusTM mixed with anti-washout gel would prevent the loss of the material from the root-end cavity when the surgical site is rinsed, or when blood flow resumes. This would probably improve the sealing ability of MTA PlusTM, as more filling material would be retained within the root-end cavity. Due to the addition of the setting accelerator, calcium chloride, Bioden-tineTM reaches an initial set within 12 minutes. This allows the operator to visually observe that the root-end filling material has set prior to closure of the surgical site. This would not be possible with MTA PlusTM or ProRoot® MTA due to the significantly longer setting times of these materials. Further studies are indicated to verify the advantages that MTA PlusTM and BiodentineTM may have over ProRoot® MTA, with regard to sealing ability when used in-vivo.

CONCLUSIONS

Within the limitations of the present study the following can be concluded:

1. Calcium silicate cements showed a significantly better sealing ability than Permite Amalgam when used as root-end filling material (p<0.001).

2. There was no significant differences in the sealing abilities of White ProRoot® MTA, MTA Plus and Biodentine™ (p<0.001).

3. Based on the findings of the present study, amalgam should be regarded as unsuitable for use as a root-end filling material.

4. Based on the findings of the present study, calcium silicate cements should be recommended as the material of choice for root-end filling.

ACRONYMS

FDA: Food and Drug Administration

PBS: phosphate buffered saline

MAP: micro apical placement

MTA: Mineral Trioxide Aggregate

References

  • 1. Chong BS, Rhodes JS. Endodontic surgery. Br Dent J. 2014; 216:281-90.
  • 2. Rubinstein R, Torabinejad M. Contemporary endodontic surgery. J Calif Dent Assoc. 2004; 32:485-92.
  • 3. Chong BS, Pitt Ford TR. Root-end filling materials: rationale and tissue response. Endod Topics. 2005; 11:114-30.
  • 4. Gartner AH, Dorn SO. Advances in endodontic surgery. Dent Clin North Am. 1992; 36:357-78.
  • 5. Parirokh M, Torabinejad M. Mineral trioxide aggregate: a comprehensive literature review-Part I: chemical, physical, and antibacterial properties. J Endod. 2010; 36:16-27.
  • 6. Priyanka SR. A literature review of root-end filling materials. IOSR-JDMS. 2013; 9:20-5.
  • 7. Friedman S. Retrograde approaches in endodontic therapy. Endod Dent Traumatol. 1991; 7:97-107.
  • 8. Tronstad L, Trope M, Doering A, Hasselgren G. Sealing ability of dental amalgams as retrograde fillings in endodontic therapy. J Endod. 1983; 9:551-3.
  • 9. Hohenfeldt PR, Aurelio JA, Gerstein H. Electrochemical corrosion in the failure of apical amalgam. Report of two cases. Oral Surg Oral Med Oral Pathol. 1985; 60:658-60.
  • 10. Baek SH, Plenk H, Kim S. Periapical tissue responses and cementum regeneration with amalgam, SuperEBA, and MTA as root-end filling materials. J Endod. 2005; 31:444-9.
  • 11. Kaga M, Seale NS, Hanawa T, Ferracane JL, Okabe T. Cytotoxicity of amalgams. J Dent Res. 1988; 67:1221-4.
  • 12. Yamada T, Fusayama T. Effect of moisture contamination on high-copper amalgam. J Dent Res. 1981; 60:716-23.
  • 13. Roberts HW, Toth JM, Berzins DW, Charlton DG. Mineral trioxide aggregate material use in endodontic treatment: a review of the literature. Dent Mater. 2008; 24:149-64.
  • 14. Camilleri J, Pitt Ford TR. Mineral trioxide aggregate: a review of the constituents and biological properties of the material. Int Endod J. 2006; 39:747-54.
  • 15. Lee SJ, Monsef M, Torabinejad M. Sealing ability of a mineral trioxide aggregate for repair of lateral root perforations. J Endod. 1993; 19:541-4.
  • 16. Schwartz RS, Mauger M, Clement DJ, Walker WA. Mineral trioxide aggregate: a new material for endodontics. J Am Dent Assoc. 1999; 130:967-75.
  • 17. Darvell BW, Wu RC. "MTA"-an Hydraulic Silicate Cement: review, update and setting reaction. Dent Mater. 2011; 27:407-22.
  • 18. Camilleri J. Hydration characteristics of calcium silicate cements with alternative radiopacifiers used as root-end filling materials. J Endod. 2010; 36:502-8.
  • 19. Torabinejad M, White DJ. Tooth filling material and method of use: US Patent No. 5769638. 1998.
  • 20. Camilleri J. Hydration mechanisms of mineral trioxide aggregate. Int Endod J. 2007; 40:462-70.
  • 21. Bozeman TB, Lemon RR, Eleazer PD. Elemental analysis of crystal precipitate from Gray and White MTA. J Endod. 2006; 32:425-8.
  • 22. Asgary S, Parirokh M, Eghbal MJ, Stowe S, Brink F. A qualitative X-ray analysis of white and grey mineral trioxide aggregate using compositional imaging. J Mater Sci Mater Med. 2006; 17:187-91.
  • 23. Camilleri J, Formosa L, Damidot D. The setting characteristics of MTA Plus in different environmental conditions. Int Endod J. 2013; 46:831-40.
  • 24. Gandolfi MG, Siboni F, Primus CM, Prati C. Ion release, porosity, solubility, and bioactivity of MTA Plus Tricalcium Silicate. J Endod. 2014; 40: 1632-7.
  • 25. Formosa LM, Mallia B, Camilleri J. A quantitative method for determining the antiwashout characteristics of cement-based dental materials including mineral trioxide aggregate. Int Endod J. 2013; 46:179-86.
  • 26. Bortoluzzi EA, Broon NJ, Bramante CM, Garcia RB, de Moraes IG, Bernardineli N. Sealing ability of MTA and radiopaque Portland cement with or without calcium chloride for root-end filling. J Endod. 2006; 32:897-900.
  • 27. Khayat KH. Effects of antiwashout admixtures on fresh concrete properties. ACI Mater J. 1995; 92:164-71.
  • 28. Formosa LM, Mallia B, Camilleri J. Mineral trioxide aggregate with anti-washout gel - properties and microstructure. Dent Mater. 2013; 29:294-306.
  • 29. Pawar AM, Kokate SR, Shah RA. Management of a large periapical lesion using Biodentine as retrograde restoration with eighteen months evident follow up. J Conserv. Dent. 2013; 16:573-5.
  • 30. Rajasekharan S, Martens LC, Cauwels RG, Verbeeck RM. Biodentine material characteristics and clinical applications: a review of the literature. Eur Arch Paediatr Dent. 2014; 15:147-58.
  • 31. Septodont. Biodentine™ Package insert [Online]. Available from: http://www.septodont.ca/sites/default/files/Biodentine%20IFU_0.pdf [Accessed October 2014].
    » http://www.septodont.ca/sites/default/files/Biodentine%20IFU_0.pdf
  • 32. Priyalakshmi S, Ranjan M. Review on Biodentine-A bioactive dentin substitute IOSR-JDMS. 2014; 13:13-7.
  • 33. Camilleri J, Kralj P, Veber M, Sinagra E. Characterization and analyses of acid-extractable and leached trace elements in dental cements. Int Endod J. 2012; 45:737-43.
  • 34. Camilleri J, Sorrentino F, Damidot D. Investigation of the hydration and bioactivity of radiopacified tricalcium silicate cement, Biodentine and MTA Angelus. Dent Mater. 2013; 29:580-93.
  • 35. Grech L, Mallia B, Camilleri J. Investigation of the physical properties of tricalcium silicate cement-based root-end filling materials. Dent Mater. 2013; 29:e20-8.
  • 36. Timpawat S, Vongsavan N, Messer HH. Effect of removal of the smear layer on apical microleakage. J Endod. 2001; 27:351-3.
  • 37. Torabinejad M, Parirokh M. Mineral trioxide aggregate: a comprehensive literature review-part II: leakage and biocompatibility investigations. J Endod. 2010; 36:190-202.
  • 38. Pichardo MR, George SW, Bergeron BE, Jeansonne BG, Rutledge R. Apical leakage of root-end placed SuperEBA, MTA, and Geristore restorations in human teeth previously stored in 10% formalin. J Endod. 2006; 32:956-9.
  • 39. Verissimo DM, do Vale MS. Methodologies for assessment of apical and coronal leakage of endodontic filling materials: a critical review. J Oral Sc. 2006; 48:93-8.
  • 40. Youngson CC, Jones JC, Manogue M, Smith IS. In vitro dentinal penetration by tracers used in microleakage studies. Int Endod J. 1998; 31:90-9.
  • 41. Camps J, Pashley D. Reliability of the dye penetration studies. J Endod. 2003; 29:592-4.
  • 42. Torabinejad M, Higa RK, McKendry DJ, Pitt Ford TR. Dye leakage of four root end filling materials: effects of blood contamination. J Endod. 1994; 20:159-63.
  • 43. Schafer E, Olthoff G. Effect of three different sealers on the sealing ability of both thermafil obturators and cold laterally compacted Gutta-Percha. J Endod. 2002; 28:638-42.
  • 44. Chong BS, Pitt Ford TR, Watson TF, Wilson RF. Sealing ability of potential retrograde root filling materials. Endod Dent Traumatol. 1995; 11:264-9.
  • 45. Abdal AK, Retief DH, Jamison HC. The apical seal via the retrosurgical approach. II. An evaluation of retrofilling materials. Oral Surg Oral Med Oral Pathol. 1982; 54:213-8.
  • 46. Vertucci FJ, Beatty RG. Apical leakage associated with retrofilling techniques: a dye study. J Endod. 1986; 12:331-6.
  • 47. SDI. Pre-dosed amalgam capsules Permite, Lojic+ & GS-80 Instructions For Use [Online]. Available from: http://www.sdi.com.au/images/stories/instructions/instructions_pdf/amalgam _P_L_G/in_amalgam_p_l_g_en.pdf [Accessed October 2014].
    » http://www.sdi.com.au/images/stories/instructions/instructions_pdf/amalgam _P_L_G/in_amalgam_p_l_g_en.pdf
  • 48. Torabinejad M, Watson TF, Pitt Ford TR. Sealing ability of a mineral trioxide aggregate when used as a root end filling material. J Endod. 1993; 19:591-5.
  • 49. Aqrabawi J. Sealing ability of amalgam, super EBA cement, and MTA when used as retrograde filling materials. Br Dent J. 2000; 188:266-8.
  • 50. Davis JL, Jeansonne BG, Davenport WD, Gardiner D. The effect of irrigation with doxycycline or citric acid on leakage and osseous wound healing. J Endod. 2003; 29:31-5.
  • 51. Pereira CL, Cenci MS, Demarco FF. Sealing ability of MTA, Super EBA, Vitremer and amalgam as root-end filling materials. Braz Oral Res. 2004; 18:317-21.
  • 52. Kokate SR, Pawar AM. An in vitro comparative stereomicroscopic evaluation of marginal seal between MTA, glass ionomer cement & Biodentine as root end filling materials using 1% methylene blue as tracer. Endodontology. 2012; 24:36-42.
  • 53. Ravichandra PV, Vemisetty H, Deepthi K, Reddy SJ, Ramakiran D, Krishna MJN, et al. Comparative evaluation of marginal adaptation of Biodentine™ and other commonly used root end filling materials - an in vitro study. JCDR. 2014; 8:243-5.

Correspondence:
Hussein C Seedat
Department of Odontology, School of Dentistry
University of Pretoria
Gauteng, South Africa
Cell: 083 564 7860
E-mail:

Correspondence

drhseedat@gmail.com

Publication Dates

  • Publication in this collection
    03 June 2016
  • Date of issue
location_on
The South African Dental Association (SADA) The South African Dental Association (SADA), Private Bag 1, Houghton, Johannesburg, Gauteng, ZA, 2041, Tel: +27 11 530 6520 - E-mail: nmojela@sada.co.za
rss_feed Acompañe los números de esta revista en su lector de RSS
Ir para arriba