Logomarca do periódico: R&D Journal

Open-access R&D Journal

Publication of: South African Institution of Mechanical Engineering
Area: Engenharias
ISSN printed version: 0257-9669
Creative Common - by 4.0

Table of contents

R&D Journal, Volume: 29, Published: 2013
Sort publications by

R&D Journal, Volume: 29, Published: 2013

Document list
Documents
Articles
A Shook Tube Driven Transonic Wind Tunnel Nash, J. Skews, B. W.

Abstract in English:

A small transonic wind tunnel was designed, constructed and calibrated in order to provide a tool for the study and demonstration of transonic flow phenomena. The wind tunnel makes use of flow properties following the propagation of a shock wave along a tube in order to create the transonic flow. This is in contrast to conventional transonic facilities which are supplied from a reservoir or compressor through a nozzle. An RAE2822 aerofoil was used as the test piece due to the large amount of aerodynamic data available on it, especially in the transonic flow region, thus making it an excellent tool for validation. In addition, numerical simulations were conducted for comparison with the experiments. The short duration test time, which is determined by the tube length, was found to be adequate for establishing semi-steady state flow for a range of transonic flow Mach numbers. The results obtained experimentally compare well to results obtained numerically. The need for the addition of sophisticated instrumentation is identified.
Articles
Development of a Magnetic Intra-Uterine Manipulator Doll, S Scheffer, C du Toit, G

Abstract in English:

This paper introduces the concept of a novel magnetic intra-uterine manipulator, intended to overcome conventional medical devices' shortcomings, and enabling non-invasive uterine manipulation during surgery. However, analyses have shown that the magnetic manipulator is unable to compete in terms of the range of motion of the existing devices. A limited anterior sagittal rotation range of 60° was observed in a magnetic manipulator compared to a range of 140° for conventional devices. Despite these limitations, use of a magnetic manipulator could eliminate the need for an additional medical assistant during surgery; it is also reusable and thus also more economical. The second goal of the research was to investigate which type of setup would be most successful in effective uterine manipulation. Through concept analysis, a cart-on-arch system was deemed most effective. To lift an effective load of 1 N over an air gap of 150 mm, rare-earth N38 neodymium (NdFeBr) magnets showed the most promise as magnetic actuators for the manipulator. Finite Element Analysis (FEA) simulations of the magnetic set-up were validated experimentally and produced an acceptable Mean Absolute Error (MAE) of 0.15 N.
Articles
Parameter Identification and Evaluation of a Proportional Directional Flow Control Valve Model van der Merwe, J Muller, JH Scheffer, C

Abstract in English:

Servo-pneumatic command device selection and control may be greatly aided by adequate mathematical models and identification procedures. This paper reports on theory and experimental procedures applicable to the characterisation of pneumatic proportional directional flow control valves. The model implemented is shown to be well suited to predicting the effects that sharp-edged, concatenated orifices and small openings have on mass flow. An experimental setup and test protocol is presented that is less wasteful in terms of energy and effort than that of the ISO 6358:1989(E) standard. Unknown model parameters are optimised during the identification procedure, characterising the behaviour of the valve for the entire range of control signal inputs. The identified model yields adequate results, with mean absolute error (MAE) values of less than 10 kPa in the presence of 700 kPa supply pressure for quasi-static control signal inputs. Acceptable prediction is also achieved for the transient control input case investigated. The work presented here then not only serves as a thorough introduction to proportional servo valve modelling theory and identification but may also prove suitable for use in a multitude of practical applications.
Articles
Modelling and Experimental Validation of a Loop Heat Pipe Page, M.C. Brooks, MJ. Roberts, L.W. Bemont, C.

Abstract in English:

The Loop Heat Pipe (LHP) is a passive, two-phase heat transfer device employed in aerospace and, increasingly, terrestrial applications. A porous wick, placed solely in the evaporator, maintains circulation, and the remaining piping is a conduit for vapour and liquid. LHPs can transport heat over long distances, operate in adverse gravitational positions, tolerate numerous bends and are self-priming due to the compensation chamber passively providing liquid access to the wick. A robust mathematical model of the steady-state operation of an LHP for terrestrial high heat flux electronics was created and validated from data generated by an experimental LHP. The LHP was also operated in gravity-adverse and assisted elevations of 5° and 10°. The porous wick has a 60 % porosity, 6.77x10-13 m2 permeability and an average pore radius of 1 μm. Ammonia was the chosen working fluid.The predicted values during the constant conductance mode of operation accurately reflected the experimental results. Theoretical values for the variable conductance mode were much less accurate and the model required additional empirical values to correct them. The maximum heat loads were 60 W, 50 W and 110 W for horizontal, gravity-adverse and gravity-assisted operation respectively.
Articles
Probabilistic Uncertainty Identification Modelling in USV Obstacle Detection Onunka, Chiemela Bright, Glen Stopforth, Riaan

Abstract in English:

Uncertainty and false alarms exist in the operational environment of autonomous marine robots. This paper presents the investigations on obstacle detection and avoidance model of an autonomous marine vehicle using ultrasonic sensors and probabilistic techniques in uncertainty identification in the development of an unmanned surface vehicle (USV). Probabilistic techniques were used in modelling the realistic environmental uncertainties of the autonomous marine vehicle. Coherence and non-coherence of sonar signals were investigated and its functions simplified to address the deterministic and un-deterministic modelling variables that were identified in the realistic domain of the USV. The results obtained from the models were adapted into the control algorithm of the USV to reduce the uncertainties present in the guidance and control of the USV.
Articles
A User Interface for a Seven Degree of Freedom Surgical Robot Heunis, J.S. Scheffer, C. Schreve, K.

Abstract in English:

This paper presents the design of a joystick-type user interface for the master-slave control of a seven degree of freedom (DOF) minimally invasive surgical robot. The joystick is a seven DOF all revolute articulated arm. The electronic design implements AS5040 magnetic rotary encoders for the joystick's position and orientation tracking. The control system required the mathematical modelling of the joystick and robot using the Denavit-Hartenberg convention. Testing demonstrates the intuitiveness of the joystick control.
location_on
South African Institution of Mechanical Engineering Research and Development Journal, University of Stellenbosch, Private Bag X1, Matieland, Cape Town, Western Cape Province, ZA, 7602, Tel: +27 21 808 4091 - E-mail: gillianc@sun.ac.za
rss_feed Stay informed of issues for this journal through your RSS reader
Go to top