Table of contents
R&D Journal, Volume: 18, Published: 2002
Sort publications by
R&D Journal, Volume: 18, Published: 2002
| Documents |
|---|
|
Articles A novel 8-element gauge for residual stress assessment using the high speed centre hole drilling method McGrath, P.J. Hattingh, D.G. James, M.N. Abstract in English: Many researchers and scientists have contributed, over the years, to the development of residual stress assessment technology since it was first reported by Mathar in 1933. Despite such work, a commonly held view is that residual stress analysis using strain gauges is a technique whose use is restricted to homogeneous and isotropic materials. Texturing and plastic deformation are felt to lead to a significant lack of repeatability in the data. This lack of certainty has had a negative impact on beneficial uses of residual stresses in optimising fatigue and fracture performance through manipulating and controlling their magnitude. The work reported in this paper demonstrates an improvement in repeatability of residual stress measurement via strain gauges, in the presence of plastic deformation and texturing effects. |
|
Articles On-line data interpretation and analysis for the EDM process using self-organising maps (SOM) Naude, J. Katz, Z. Abstract in English: The complexity of the EDM process, expressed by the multitude of interrelated parameters, presents a serious practical problem in the on-line analysis of the process performance. Such analysis is required for settings, optimisation and data interpretation for prompt diagnosis and control. This work attempts to improve the monitoring, diagnosis and control capability of the EDM through a graphical presentation of the on-line process tendencies. Moreover, an extended system of remote monitoring, data collection and performance through the Internet is proposed. It is expected that the implementation of the described method will facilitate and improve the performance of the EDM process. |
|
Articles Application of maintenance partnering in South African manufacturing industries Mohlakoana, G. Visser, J.K. Abstract in English: Global competition is putting pressure on companies to review their business operations, such as maintenance, for business survival. This review resulted in strategies such as utilising contractors to supplement internal maintenance staff in carrying out maintenance work. However, this traditional client-contractor relation has been found detrimental to improving the effectiveness of maintenance management. Recent developments in maintenance management have identified maintenance partnering as an alternative strategy to the traditional approach to meet the challenges brought by global competition. Maintenance partnering allows all parties to work together with common objectives and shared risks. This paper discusses the results of an investigation into the experience of South African manufacturing industries regarding maintenance partnering. Factors such as top management support, common goals and relationship building were identified as critical for successful partnering. The benefits and disadvantages of maintenance partnering were also identified. |
|
Articles Numerical simulation of a wet cooling tower van der Merwe, J. du Toit, CG. Abstract in English: A numerical model to predict the flow field in and around a counter flow induced draft wet cooling tower was developed and tested. The numerical model consisted of the Thiart fan model, a Lagrangian droplet model and a packing model. The droplet model exposed the need to model the effect of the packing on the droplets and a simplified model was implemented to prolong the droplet retention time in the packing. The full cooling tower model predicted trends, at design conditions and with a wind present, which compared well with results reported in the literature. |
|
Articles Solar chimney power plant performance characteristics Kröger, D.G. Buys, J.D. Abstract in English: The performance characteristics of a large solar chimney power plant are evaluated. The reference plant studied has a glass-covered collector and a chimney that is 1 500 m high with a diameter of 160 m. A turbo-generator is located at the base of the chimney. The draught and relevant energy equations applicable to the plant are solved for specified meteorological data at a particular site in South Africa. It is shown that the output of the plant changes measurably during the day and that power is also generated during the night, due to the thermal capacity of the ground under the solar collector. By optimising the shape and height of the solar collector, the annual power output can be increased. |
|
Articles Computer simulation of internal combustion engine flow processes van Vuuren, CM. Thiart, G.D. Taylor, A.B. Abstract in English: A computer code for the simulation of internal combustion engine processes is presented. The main objective of the code is to serve as a tool for the design of inlet and outlet manifolds of combustion engines. The code is built around a two-zone thermodynamic combustion model that is linked to a quasi one-dimensional unsteady method of characteristics pipe flow model and a camshaft model. Two simple test cases are presented to show that the pipe flow model functions correctly. Predictions of the crankshaft power delivered by a commercial internal combustion engine computed by means of the code are shown to compare favourably with measured results. An example illustrating the usefulness of the code as a design tool is also presented. |
|
Articles Optimal design of intermittently operated subsonic-supersonic ejectors Pienaar, D.vV. Abstract in English: The optimal design for maximum run duration of intermittently operated subsonic-supersonic air-air ejector pumps of fixed geometry was investigated using an inviscid one-dimensional model of the mixing chamber. The study was confined to the case of matched static pressures of the primary and secondary air streams. An empirical correction factor was applied to the ID results in order to take approximate account of the two-dimensional velocity distributions at the inlet and outlet of the mixing chamber and of viscous shear forces. Optimisation of both the primary and secondary Mach numbers was found to yield significantly longer run durations than when the secondary is flow is sonic and just the primary Mach number is optimised. The most pronounced advantages of optimising both the primary and secondary Mach numbers were obtained in the range of high ejector performance. The main advantage is that an optimised ejector is physically smaller, and requires a smaller storage vessel than one that is not optimised. |
|
Articles Convection heat transfer between a horizontal surface and the natural environment Kröger, D.G. Abstract in English: The problem of heat transfer between an infinite horizontal surface and the natural environment is analysed. When such a surface is heated, due to solar radiation, heat will be transferred to the environment by radiation and convection. The approximate convection heat transfer coefficient under these conditions is determined theoretically and compared to previous experimentally measured values. |
|
Articles Solar collector performance Lombaard, I.F. Kröger, D.G. Abstract in English: In this investigation, the temperatures of the insulated collector plate and glass cover of a horizontal solar collector were measured and compared to theoretically predicted values for different ambient conditions. By employing an appropriate equation for the prediction of the heat transfer between the cover and the natural environment, good agreement was obtained between the theoretically predicted and experimentally measured values. |
|
Articles Performance of rotor-only axial fans designed for minimum exit kinetic energy van der Spuy, SJ. von Backström, T.W. Abstract in English: The major loss source in rotor-only axial fans is the kinetic energy associated with the axial and circumferential components of the exit flow. This paper investigated the aerodynamic and acoustic performance of two fans designed to produce minimum exit kinetic energy. The first was a general application fan and the second a low-noise fan with large-chord forward-swept blades. The fans were tested for fan noise and performance in accordance with BS 848. The low-noise fan was the quieter and more efficient of the two fans, whilst both fans were quieter and more efficient than an existing typical general application fan, of unknown design. The results underlined the importance of following a well-defined design methodology when designing rotor-only axial flow fans. |
|
Articles Forces on the swimming hand Stewart, A. Skews, B.W. Abstract in English: The purpose of this work was to determine which hand geometry is the most effective when swimming crawl, and to examine the relative contributions of lift and drag forces to forward propulsion. Three 'different hand geometries were used: flat hand with fingers slightly spread, flat hand with fingers together, and cupped hand. The forces on each were determined at six characteristic points in the stroke, which were established from examination of published photographs of an expert swimmer. The relative velocity between the hand and the water for each of these positions was determined. Wind tunnel tests were conducted under conditions of flow similarity and correct hand orientation, and the forces on full-scale hand models measured. It was established that there was no single best hand geometry. In hand positions where the backward component of hand velocity is dominant, the geometry with fingers slightly apart was best, and drag forces were the main contributor to forward propulsion. When the sideways component of hand velocity was dominant, the hand geometry with fingers together was best and when the main component of hand velocity was upward, the cupped hand was best, with lift forces being significant. |
|
Articles Fan blade damage detection using on-line vibration monitoring Smit, W.G. Heyns, P.S. Abstract in English: The use of on-line vibration monitoring of fan blades to detect and classify damage levels on blades was investigated. It was shown that output only data can be used to determine modal parameters, such as natural frequencies, with sufficient accuracy to be used as damage indicators. This is only possible if sensors are mounted on the blades themselves, thereby ensuring that the dynamics of the blades can be accurately monitored. A finite element model was used to study the feasibility of using frequency shifts as damage indicators on rotating fan blades. The results indicated that certain mode shapes are more sensitive to damage at the root of the blade. An experimental fan blade damage simulator was then used to verify these findings experimentally. A hypothesis, that the differences in frequency shift due to damage between the finite element model and the experimentally measured frequencies is the result of global structural behaviour, was verified by making use of an extended finite element model. Local mode shapes make it possible to classify damage levels on individual blades using one sensor per blade only. Damage levels of as low as 10% could be detected experimentally. |
Read our Open Access Statement
