Logomarca do periódico: R&D Journal

Open-access R&D Journal

Publication of: South African Institution of Mechanical Engineering
Area: Engenharias
ISSN printed version: 0257-9669
Creative Common - by 4.0

Table of contents

R&D Journal, Volume: 16, Published: 2000
Sort publications by

R&D Journal, Volume: 16, Published: 2000

Document list
Documents
Articles
Flooding during reflux condensation of steam in an inclined elliptical tube Schoenfeld, P.D. Krögert, D.G.

Abstract in English:

In this experimental investigation the pressure drop is measured between the headers located at the ends of an inclined air-cooled elliptical tube in which reflux condensation of steam occurs. The cross-section of the 7 m long tube has a height of 97 mm (major axis) and a width of 16 mm (minor axis). Steam temperatures are in the range of 45° C to 65° C. The pressure drop can be predicted accurately using the Zapke-Kròger pressure drop model applicable to reflux condensers. At a certain steam flow rate a sudden sharp increase in the pressure drop occurs. This phenomenon is known as flooding. The measured vapour velocities at flooding agree well with the values predicted by the Zapke-Kröger flooding correlation. The experimental results also show that flooding has a detrimental effect on the thermal effectiveness of the elliptical tube.
Articles
Modelling of beams using the reduced integration technique: statics and free vibrations Kekana, M. Badurt, J.

Abstract in English:

There has been considerable interest over the past two decades in studies of locking phenomenon that occurs in shell, plate and beam elements. This has largely been due to the misunderstanding of the role of reduced integration - on the modelling of the displacement field across the thickness. Therefore, the phenomenon of locking is reviewed and re-examined using, as an illustrative example, a model of thick and thin elastic beam. It is shown that by introducing reduced integration in the stiffness matrix, instead of full integration, we introduce to the model an assumption that straight segment normal to the mid-surface before deformation stays normal after deformation. That is, reduced integration introduces the Kirchhoff-Love assumption at the numerical level. Appropriate calculations regarding thick and thin beams are presented and discussed.
Articles
The solar chimney air standard thermodynamic cycle von Backström, T.W. Gannon, A.J.

Abstract in English:

The paper presents an air standard thermodynamic analysis for the solar chimney cycle. A solar chimney is a power plant in which air, heated under a glass-decked solar collector, escapes through a power generating turbine at the base of a chimney. Simple equations were derived for the cycle efficiency, power per unit mass flow and available turbine pressure drop, assuming ideal air as process gas and ideal reversible processes. The main conclusions were the following: the cycle efficiency is directly proportional to the chimney height; unlike the gas turbine cycle, there is no optimal pressure ratio (chimney height) for maximum specific power; the power per unit mass flow developed by the plant is directly proportional to the cycle efficiency and the temperature rise in the solar collector; the pressure drop across the turbine is proportional to the chimney height and the collector temperature rise. A design condition where the chimney exit temperature equals the collector inlet temperature was also proposed for initial calculations. The specific power of the plant is then approximately proportional to the square of the cycle efficiency. The analysis enables one to do initial sizing of a plant for a given required power.
Articles
Vapour compression refrigerator performance with R-12/R-134a refrigerant mixtures Sheer, T.J. Albrecht, R.

Abstract in English:

A series of laboratory tests was carried out, using a small reciprocating-compressor refrigeration system, to measure the system performance characteristics over a range of R-12/R- 134a refrigerant mixture compositions as well as using the pure components. The test facility was carefully instrumented and data for various operating conditions were recorded with a computer data acquisition system. The tests covered a range of evaporating temperatures from 0 to 10° C, for three different condenser water exit temperatures. The test data revealed that it is feasible or even beneficial to perform a "refrigerant metamorphosis" from R-12 to R-134a. A refrigerant metamorphosis is a gradual conversion of the composition of the refrigerant charge through progressive topping-up, as leakages occur, with a refrigerant different from that originally used. It was found experimentally and verified by simulation that increases in the cooling capacity and coefficient of performance (COP) were experienced for the near-azeotropic mixtures of these two refrigerants. Pure R-134a gave a superior COP to pure R-12 for high evaporating temperatures, but mixtures of the two gave even higher COPs. No negative characteristics (e.g. high saturation pressure or high compressor discharge temperature) were observed. Predictions from theoretical simulations deviated in certain respects from the actual measurements and the reasons for these deviations are discussed.
Articles
Thermal characterisation of an ammonia-charged two-phase closed thermosyphon Dobson, R.T. Kröger, D.G.

Abstract in English:

The thermal performance characteristics including the evaporator and condenser heat transfer coefficients and the maximum heat transfer rate for an ammonia charged two-phase closed thermosyphon have been experimentally determined for vertical and inclined orientations. The thermosyphon tested is 6.2 m long and has an internal diameter of 31.9 mm and is made of grade 304 stainless steel. Hot water of up to 80° C and cooling water of between 10 and 20°C, inclination angles of 30, 45, 60, 75 and 90° to the horizontal, evaporator to total length ratios of 0.06 to 0.33 and liquid charge fill ratios (Le/Le) of between 20 and 100 % were considered. The correlations of the experimental data for the heat transfer coefficients are given in terms of the wall heat flux, internal pressure, liquid charge fill ratio and angle of inclination. The correlation for the superficial velocity at which the heat transfer rate could not be increased further by increasing the temperature difference between the evaporator and the condenser was determined in terms of internal temperature, liquid charge fill ratio and inclination angle. The experimentally determined values of the heat transfer coefficients did not correspond well with existing correlations. This is attributed to the limited availability of ammonia as working fluid and inclined thermosyphon orientations in the data sets upon which these existing correlations 'were based, as well as the generally complex nature of the various heat transfer mechanisms that occur in a thermosyphon.
Articles
On the feedback control gain of smart composite beams based on Mindlin-Reissner lamination theory Sun, Bohua Huang, Da

Abstract in English:

The discussion of negative-velocity feedback control gain Ci is presented in this paper. For all the existing models, they normally neglect the electric charge of the actuator introduced by the mechanical force applied on the smart-composite structure. In this paper, the electric charge of the actuator is considered and the expression of the feedback control gain Gi is also studied. Numerical results are presented to demonstrate the scale of the feedback control gain.
Articles
Sizing and management of domestic solar electric installations Tully, N.

Abstract in English:

The performance of a solar photovoltaic system for a domestic installation is predicted using an hourly solar radiation database. A standard procedure is used to estimate the annual average daily solar energy collected by a typical photovoltaic panel, and a system thus sized to to supply a defined average daily energy load with batteries to give between three and five days of energy backup. It is found that this approach gives a system which should provide full service on every day of the year. A matrix of alternative combinations of numbers of panels and storage batteries which can also maintain service is presented, together with indications of the loss of service due to under-designed systems. The possibility of employing a load management strategy to improve the serviceability of a scaled down system is. examined, and it is found that an acceptable performance might still be obtained with a 15% reduction in panel area.
Articles
Condensation in an annulus with spiralled wires Coetzee, Sarel da Veiga, Willem R. Meyer, Josua P.

Abstract in English:

There are different types of heat transfer enhancement techniques that can be used in air-conditioning and refrigeration systems to improve heat transfer, reduce heat transfer area or weight and to decrease the logarithmic mean temperature difference. Some of the heat transfer techniques are expensive and cannot be afforded by small manufacturing firms. An easy and affordable technique considered in this paper has a wire spiralled in the annulus of a water-cooled, tube-in-tube condenser, where R-22 is condensing in the annulus while the water flows through the inner tube. The purpose of this paper was to determine the heat transfer and pressure drop characteristics of the refrigerant R-22 in the annulus. Measurements were taken on four different heat exchangers, three with wires spiralled in the annulus at different angles and one without any wires used as a reference. It could be concluded that the use of the wires improved the overall heat transfer coefficient by up to 350% (45° spiral). However, as expected the pressure drop also increased, by 225%.
Articles
A review of domestic hot-water consumption in South Africa Meyer, Josua P.

Abstract in English:

A review is given of domestic hot-water consumption for five different types of dwellings in the developed and developing communities of the Johannesburg Metropolitan area, South Africa. The types of dwellings are houses, town houses, apartments, traditional houses and shacks. The consumptions were determined with direct measurements over a period of one year (1996) in 770 dwellings. The hot-water consumptions were taken monthly with the exception of 310 dwellings - where the measurements were also logged, resulting in hourly hot-water consumptions. The results of the two types of measurements are presented for the different types of dwellings: firstly, hot-water consumption per person per day for the different months of a year; and secondly, hourly hot-water consumption per person per day as a function of winter weekdays.
Articles
Velocity measurement in a hydrodynamic torque converter Strachan, P.J. von Backström, T.W.

Abstract in English:

An experimental torque converter in which flow characteristics could be both observed and measured was manufactured and tested. Flow visualisation was carried out by means of fluorescent tufts, air bubbles and polystyrene particles, and from these visualisations, flow velocities and angles were determined by using video and still photography. Differential pressure probes were used for direct measurement of flow velocity at different stations in the flow path. Agreement between results obtained by these different methods was good. The torque converter performance was also simulated by means of a o ne-dimensional hydro-dynamic model, and acceptable overall agreement was obtained between measured parameters and the model's results.
location_on
South African Institution of Mechanical Engineering Research and Development Journal, University of Stellenbosch, Private Bag X1, Matieland, Cape Town, Western Cape Province, ZA, 7602, Tel: +27 21 808 4091 - E-mail: gillianc@sun.ac.za
rss_feed Stay informed of issues for this journal through your RSS reader
Go to top