Tabla de contenido
R&D Journal, Volumen: 12, Publicado: 1996
Ordenar publicações por
R&D Journal, Volumen: 12, Publicado: 1996
| Documents |
|---|
|
Articles Verification and application of a component-based simulation technique for air-handling systems Rousseau, P.G. Mathews, E.H. Malan, A.G. Resumen en Inglés: Forty percent of the total energy used in developed countries is expended in buildings. More than half of this is used to condition the indoor environment. It is estimated that as much as 30% of the energy used for air-conditioning may be saved through the use of improved design tools. Such tools should allow simulation of the building and the air-conditioning system in an integrated manner. This paper describes the verification of a new component based air-handling system simulation technique. The new technique is based on mathematical models each of which represents a different component of the air-handling system. It facilitates the simulation of the building, the heating, ventilation, and air-conditioning (HVAC) system and its controller in an integrated manner. Each individual mathematical component model, as well as the integrated system simulation, was verified by comparing predicted and measured data of the air-handling system of the Merensky Library at the University of Pretoria. An average error of 8% was recorded. Building indoor air temperatures were predicted to within 5% of the measured values. The simulation technique was then applied in a retrofit of this system. The study, which consisted of the addition of evaporative pre-coolers to the air-handling system, showed predicted energy savings of between 12% and 40%. The required capital expenditure has a predicted payback period of less than 3 years. Having been verified and its application possibilities established, the new technique can now be successfully applied to the design and retrofit of other HVAC systems. |
|
Articles Adiabatic pre-cooling of the inlet air to an air-cooled heat exchanger Botes, H. Kröger, D.G. Resumen en Inglés: The use of adiabatic pre-cooling to regulate the temperature of the inlet air to an air-cooled heat exchanger during periods of high ambient temperatures is investigated theoretically and experimentally. Pre-cooling is achieved by spraying a rotary atomiser generated water mist into the air stream. The design of such an atomiser is briefly discussed. The use of drift eliminators to ensure a dry finned tube surface is also investigated. Pressure drop characteristics and droplet collection efficiencies of common drift eliminator shapes are determined experimentally. A conceptual air-cooled heat exchanger with pre-cooling is also modelled numerically. |
|
Articles Simplified thin-ship theory with application to the design of bulbous bows Thiart, G.D. Damant, P.D. Resumen en Inglés: A method for calculating the wave resistance of a ship by means of so-called Kelvin 'wavemaking' source panels on the centreplane of the ship is described. The method is a simplification of conventional thin-ship theory, which involves complicated Fourier expansions and which is very difficult to apply for hull forms other than those which can be described by simple analytical functions. A computer program to calculate wave resistance by means of this simplified theory was developed and used to calculate the wave resistance of a 24 m purse seine trawler. Results are presented for the trawler with and without a bulbous bow, at design speed and for two operating conditions. Fair correspondence between the prediction of the reduction in effective power requirement by means of the theory and by means of towing tank model tests was obtained. |
|
Articles Evaluation of film, jacket and internal cooling during fermentation of grape juice Gryzagoridis, J. Steenkamp, Z.J. Resumen en Inglés: Analytical and experimental aspects of water-film cooling, jacket cooling and internal cooling, which are the three predominant types of fermentation cooling found in the South African wine industry, are dealt with. The work focused on the following aspects: formulation of models which will enable simulation of each type of fermentation cooling under different running conditions for various sizes of available equipment; experimental work on all three main types of fermentation cooling under different running conditions to confirm the validity of the mathematical models; and comparison of analytical or predicted results of the performance (cooling capacity, pressure drop and effectiveness of the three types of fermentation cooling) with the experimental or measured values. |
|
Articles Quantifying engine valve deposits with machine vision Hansen, A.C. Brooker, A.G.P. Reid, J.F. Resumen en Inglés: Inlet valve deposits in petrol engines have a significant effect on engine operation with particular reference to cold starting and driveability. Present methods of quantifying these deposits by weighing them or rating them with the aid of a visual rating scale are recognised as not being reliable indices of the detrimental effect of these deposits. A valve deposit quantification system was developed that relied on the use of machine vision. Algorithms were formulated to track the silhouetted edge profile of a backlit valve from which a valve volume was determined. The valve deposit volume was calculated as the difference in volume between the valve in its clean and coked states. The system was able to detect a minimum coke deposit level of 0.06 g at the 95% confidence limit, the accuracy being based on the correlation between the volume as determined by the vision system and the mass of the deposit. |
|
Articles Numerical solution of the phase average Navier-Stokes equation using the finite element method van der Westhuizen, J. du Plessis, J. Prieur Resumen en Inglés: Recent solutions proposed for the surface integral term contained in the phase average form of the Navier-Stokes equation has transformed the equation into a practical tool for the numerical analysis of macroscopic flow through porous media. In this paper the form of these equations, governing the transport of momentum through porous media for low Reynolds number laminar flow of incompressible fluids, is cast into a set of algebraic equations using the Ritz finite element method. The continuity requirement is treated as a constraint condition and is incorporated into the algebraic equations through the penalty function method. The final set of algebraic equations is coded into a finite element software program in order to demonstrate the proposed numerical solution method. Numerical solutions included illustrate the transition from Navier-Stokes to phase average Navier-Stokes to Darcy-type controlled flow in porous media as the shear flow resistance of the porous medium is increased relative to the viscosity of the traversing fluid. In addition to this, the versatility of the proposed numerical method is demonstrated with the solution of a flow front problem for the case where a fluid penetrates into a 'dry' porous domain. |
|
Articles Residual stress evaluation using the air abrasive hole drilling technique Segal, A.M. Tait, R.B. Resumen en Inglés: This paper describes the design and construction of an air abrasive centre hole (AACH) drilling facility and its application for measuring residual stress in extruded aluminium rods as a function of processing route. The AACH system facilitated normal (rectangular sided) small hole drilling with precise optical location. Calibration tests indicated errors of typically 5%. For the extruded aluminium rods examined significant tensile hoop stresses were measured on the outer surface of rods which were roll straightened; whereas for rods subjected to a 'stretch' straightening process, the outer surface residual stresses were much smaller, compressive and randomly oriented. Stress gradients measured through the thickness of the rods showed stress reversal, with the magnitude of the stresses on the inner surface lower than those on the outer surface. A simple ring splitting process yielded comparable but less accurate average residual stress results. From this investigation, it was apparent that although the 'stretch' route resulted in improved (i.e. reduced) residual stresses, the conventional processing route was quite acceptable. |
|
Articles Modelling the turbulent flow of non-Newtonian slurries Slatter, P.T. Resumen en Inglés: The only reliable approach open to designers of pipeline systems conveying non-Newtonian slurries in the turbulent flow regime has been large scale pipe tests. This paper addresses this design problem, with particular emphasis on the theoretical modelling of the turbulent flow behaviour of these slurries in pipes. The literature and theory pertinent to the flow of slurries in pipes is examined. A new model for the prediction of the turbulent energy gradient is developed from widely accepted fundamentals. A particle roughness effect has been observed and turbulent flow is modelled using a new roughness Reynolds number to correlate the roughness function. Three test facilities were built for the establishment of a data base of non-Newtonian slurry behaviour - a tube viscometer and two pumped recirculating pipe test rigs. The experimental investigation covered wide ranges of diameter (5 mm to 200 mm nominal bore), mean pipe velocity (0.1 m/s to 10 m/s), slurry relative density (1.02 to 1.65), volumetric concentration (2% to 37%), solids relative density (2.4 to 2.8) and particle size range (d85 = 24 to 120 μm). Turbulent flow predictions using the new turbulent model are accurate and better than previous models, particularly in the rough wall region. The new analysis is based on physical behaviour and contributes to the understanding of the mechanisms involved. |
|
Articles Free surface menisci on narrow horizontal surfaces Erens, P.J. Dreyer, A.A. Resumen en Inglés: The thickness of liquid films on horizontal surfaces is important in condensation applications and in cooling tower splash-packs. In condensation the heat transfer rate is governed by the thickness of the film covering the cold surface, while in cooling tower splash-packs the volume of liquid splashing and the splash drop sizes formed by the impact of large drops on a slat is a strong function of the thickness of the water film on the slat. The splash volumes and splash drop size influence the thermal performance of splash-packing material. Approximate theoretical models for the calculation of the free surface film profile on finite-width horizontal surfaces with low liquid flow rates are presented. Experimental measurements yielded good agreement between experiment and theory. It is concluded that slat width, surface tension, surface wetting, and edge radii govern the free surface film profiles for low liquid flow rate over sharp edges. |
|
Articles Rotary regenerator design theory and optimisation Swanepoel, D.C. Kröger, D.G. Resumen en Inglés: A review of the simplest and most frequently used design theory for counterflow rotary regenerators is given. A new correlation for the effectiveness of a balanced regenerator is proposed. A computer program was written for the thermal evaluation and design of counterflow rotary regenerators. The program is used to optimise some of the operating conditions and design parameters if the effectiveness is specified. It is shown by an example how the disk rotational speed, flow split ratio and matrix wall thickness can be optimised. Five heating surfaces that were experimentally tested for their heat transfer and pressure drop characteristics are compared at their respective optimum operating points. |
|
Articles Intelligent assembly through expert system-based parts distribution Katz, Z. Zheng, F. Resumen en Inglés: Programmable though intelligent robotic assembly tasks could be facilitated by the use of appropriate sensing and compatible expert systems. The concept analysis and integration of such an expert system is presented. A specific methodology allowing the use of the expert system for a multi-stage robotic assembly process is detailed. The incorporation of the expert system in a microcomputer controlled robotic assembly cell for intelligent assembly decisions is discussed. |
|
Articles Technical Note: Improvements to the energy efficiency of shacks van Wyk, S.L. Mathews, E.H. Resumen en Inglés: The majority of very poor people in urban areas live in shacks. These shacks give shelter to inhabitants but are energy inefficient. The owner has to spend excessive amounts on biofuel, which is not only converted into heat but also into greenhouse-forming gases. Detailed thermal efficiency studies for this kind of house are therefore important but unfortunately completely lacking in the open literature. It is the aim of this paper to investigate the influence of different thermal control mechanisms on the energy efficiency of these shacks. Different thermal options were evaluated with a thermal simulation program, QUICK, developed by CENT.1 Orientation, the exterior colour, ventilation, and insulation were inter alia investigated. Of these, insulation showed the most potential. The installation of 25 mm glass wool decreases the energy consumption in winter by approximately 78%. |
Lea la Declaración de Acceso abierto