A General Approach for the Rating of Evaporative Closed Circuit Coolers Erens, P. J. Dreyer, A. A.

Abstract in English:

Numerous procedures to predict the performance of closed circuit evaporative coolers have been reported in the past with varying degrees of approximation in the thermodynamic and heat transfer equations. While these methods are generally found to be adequate for most industrial design applications, they have shortcomings when linking them to natural draught situations where a crossflow unit is preferred and the outlet air density is critical in determining the air flow rate. This article describes a more rigorous method based oh the method of Poppe [18], Bourillot [16] and Evers and Dreyer [23] as applied to conventional cooling towers.
Articles
Allocation and Prediction of Structure Safety Reliability de Kock, W. J. Stoker, P. W.

Abstract in English:

The disciplines of structural design and reliability engineering need to be brought in closer contact. Dynamic structures often require high strength and minimized mass. Classical design procedures based on the use of safety factors and given probabilities of failure are used for these structures and do not include reliability allocation or prediction. The paper explains the use of loadpaths and reliability block diagrams to model structure safety reliability. The use of structure functional entities is described. An interpretation is given of allocation and prediction of structure safety reliability as seen from a structural design point of view.
Articles
Dimensioning Heat Exchangers for Existing Dry Cooling Towers Buys, J. D. Kroger, D. G.

Abstract in English:

A method is proposed whereby the optimum dimensions of finned tube bundles for installation in an existing cooling tower are determined, subject to certain practical constraints and for a given cost structure. The influence of variations in the independent parameters is quantified.
Articles
Biogas Generators for Rural Southern Africa Jawurek, H. H.
Prediction of Mass Flow Distribution in a Complex Flow System Grant, J. J. Schumann, W. A.
Metal flow in an Isothermal Channel Thiart, G. D.