Abstract
The work presented in this paper illustrates a practical implementation of PID control on an industrial machine which is controlled by a Programmable Logic Controller (PLC). The control system was developed for controlling Friction Stir Weld (FSW) temperature although the principles of the implementation can be applied to many industrial control processes. The Ziegler Nichols PID tuning method was implemented in this example. A mathematical system model was produced using the Matlab system identification tool. The model was simulated with Matlab Simulink and the results were compared to the performance of the actual controller which was implemented on the FSW process. Derivative filters were tested and modified in order to attenuate the component of the derivative term which is produced in response to noise on the feedback signal (thermocouple sensor signal). The thermal disturbance rejection of the PID control system was tested; which rendered excellent results.
Friction Stir Weld (FSW); Temperature; Closed-loop Control; System Identification; PLC Control Architecture; PID Optimisation