Open-access Implementation Aspects of an Industrial Programmable Controller Using PID Control on a FSW Process

Abstract

The work presented in this paper illustrates a practical implementation of PID control on an industrial machine which is controlled by a Programmable Logic Controller (PLC). The control system was developed for controlling Friction Stir Weld (FSW) temperature although the principles of the implementation can be applied to many industrial control processes. The Ziegler Nichols PID tuning method was implemented in this example. A mathematical system model was produced using the Matlab system identification tool. The model was simulated with Matlab Simulink and the results were compared to the performance of the actual controller which was implemented on the FSW process. Derivative filters were tested and modified in order to attenuate the component of the derivative term which is produced in response to noise on the feedback signal (thermocouple sensor signal). The thermal disturbance rejection of the PID control system was tested; which rendered excellent results.

Friction Stir Weld (FSW); Temperature; Closed-loop Control; System Identification; PLC Control Architecture; PID Optimisation


1. Introduction

Friction Stir Welding (FSW) is a solid-state welding procedure (the weld is conducted below the work-piece melting point). The rotating FSW tool is plunged into the material until the shoulder of the tool comes into contact with the surface of the work-piece as shown in figure 1. The FSW machine applies a downward force on the tool and the frictional heat generated between the tool and the work-piece causes the material to plasticise. In addition to this, the downwards force consolidates the plasticised material. The FSW tool then traverses along the joint line to execute the pre-programmed weld. The rotation of the tool stirs the plasticised material to form the welded joint.

This research investigates a FSW control method from a weld temperature point of view for the purpose of weld quality control. This method is an alternative to FSW quality control methods already investigated at Nelson Mandela Metropolitan University which includes the "force footprint" research. This research investigated the force profile exerted by the FSW tool on the work-piece material. A custom made load cell was attached between the FSW machine and the FSW tool which was able to generate a detailed force profile for various tool geometries. The force data measured by the load cell was transmitted via a telemetry system from the rotating tool to the data acquisition system. The relationship between weld quality, FSW tool geometries and the relative forces experienced was investigated1,2,3,4.

A majority of industrial processes are not mathematically modelled which makes a theoretical control system for the process difficult to calculate. In addition to this, producing a mathematical model for a relatively simple process could involve a large amount of theoretical calculations which would consume valuable time and resources. The result of such intense calculations may yield a model for the system which has questionable accuracy due to the unavoidable, cumulative inaccuracies in theoretical representations for system components. An example of such an inaccuracy could include bearing friction or an inaccurate estimation of a machine component's inertia due to its complex shape and lack of a CAD model (which would render the inertia values). There is therefore a need for a faster, more practical and more accurate procedure for tuning machine control systems. Practical tuning methods for these systems exist; such as the Ziegler Nichols Tuning method. Should a process model be required, engineering tools such as the MATLAB System Identification Tool can identify a mathematical model for a particular process from the results of a test which is conducted on the process itself. Input commands and recorded process output response values are given to the MATLAB System Identification Tool and a mathematical process model is then generated based on the data. The tool also identifies the accuracy of the model's representation of the process data (model fit as a percentage). This tool significantly reduces the amount of calculations required to produce a mathematical model of the process and will often yield a more accurate result than a model which was calculated from first principles based on process geometry and dynamics. The tool reduces the amount of cumulative inaccuracies in the identification procedure.

The preliminary research for this study investigated FSW temperature response to spindle speed changes5. The discussion presented in this paper is based on experimental work6. The procedure for executing the Ziegler Nichols PID tuning method on FSW temperature control is detailed in this document. The weld temperature graphs are shown for the tuning phase as well as the system response testing phase of the work. The response of the control system showed that PID control is sufficient to control FSW temperature accurately although weld temperature may fluctuate more or less around the set-point depending on certain factors. These include the weld events preceding control about the specific set-point as well as the position of the set-point in the temperature range of the process.

Temperature control of FSW has been studied7. The study7 shows some control data although it focuses on the influence which weld temperature has on weld quality whereas this paper focuses on the implementation aspects of PID control. During the welds conducted in this research, the downward force is maintained using PID control. The PID temperature control (which is solely focused upon in this paper) is implemented simultaneously with the force control although the two systems behave independently. Any influence which one system has on the controlled variable of the other is compensated for by the affected system independently. The tuning of each system is unaffected by the other since they have different actuators and a change caused by one system can be considered a disturbance for the other; for which it compensates for. This paper also investigates the robustness of the PID control system (for this particular implementation) by introducing thermal disturbances on the weld plate. The performance of the control system in response to these disturbances determines the robustness of the system.

2. Experimental Setup

The plates which were used for the experimental welds conducted in this research were 750 mm x 100 mm x 6.1 mm AA6082-T6. The backing plate which forms the lower boundary of material consolidation was manufactured from 17-4 PH stainless steel.

The FSW tool used in this research was manufactured from W302 tool steel and consisted of a 22 mm diameter shoulder; a 6o concave shape on the bottom of the shoulder; a 5.77 mm in length straight, threaded, 7.9 mm diameter pin with 0.8 mm thread pitch. The FSW tool was hardened to 54 RC. The FSW tool is shown in figure 2.

Considering the material welded in this research (which has a liquidus temperature of approximately 660 oC 8), J-type thermocouples were selected based on their temperature range. Two thermocouple holes were EDM machined into the FSW tool such that the thermocouple tips are located were the tool shoulder meets the tool pin with 0.2 mm of tool material between the thermocouple tips and the weld zone material. A mock-up tool was machined in order to ensure that the thermocouple tips are located correctly which is shown in figure 3.

The FSW machine head is shown in figure 4. The telemetry rotor (which contains the circuitry for amplifying the thermocouple signals and transmitting the data) and the stationary telemetry antenna are shown in the figure. The antenna powers the rotor inductively and collects the thermocouple signal data via radio frequency signal.

The weld plate setup is shown in figure 5. Bead on plate welds were conducted for process development purposes because the parameters for the weld are essentially the same as those for a conventional FSW. A bead on plate weld reduces weld preparation tasks and eliminates variables which could influence weld results (such as plate gap variation and variations in the surface finish of the two machined edges of a conventional FSW).

3. Control Algorithm

The control algorithm is programmed onto the FSW machine controller; which is a programmable logic controller (PLC). The algorithm component of the control system is outlined by the red, solid rectangle in figure 6.

The physical machine and weld components are bounded by the black, dashed square in figure 6. The FSW process is influenced by numerous factors and is comprised of many variables although for the purpose of this study, only the weld temperature and the variable factors which influence weld temperature are considered and shown in the diagram. The traverse speed is maintained at a constant 200 mm/min for the duration of this study because spindle speed has a much greater influence on weld temperature than changes in the traverse speed of the tool7,9. The FSW temperature is therefore influenced by thermal disturbances and spindle speed changes in this study. The spindle speed command is indicated in the diagram of figure 6 and is the output command given from the control algorithm (programmed onto the PLC) to the spindle motor drive. The weld temperature is considered an output from the process and is measured by the thermocouples which are embedded into the FSW tool. The thermocouple signals are amplified and conditioned by the telemetry rotor circuitry which rotates with the tool and transmits the signals via radio frequency modulation to the stationary receiver. The receiver demodulates the signal and generates a ±10 V analog signal for each channel (each thermocouple signal). The analog to digital conversion cards convert the analog signals to a digital value (voltage measurement stored in a PLC variable) which is used in PLC mathematical calculations.

The control algorithm flow diagram which is shown in figure 7 illustrates the method which was programmed onto the PLC which implements the PID control.

The algorithm begins by calculating actual temperature measured by the thermocouples from the digital value generated by the analog to digital conversion cards. This calculation is based on the calibration curves (which were generated using a furnace, the thermocouples, the telemetry system, the analog to digital conversion cards, the PLC and a thermometer) which relate the voltage value measured by the PLC to the temperature measured at the thermocouple tips. The average temperature of the two thermocouples is calculated and stored in the variable "Temp" shown in the diagram.

The first step in the control calculations is to calculate the error term which is the difference between the weld temperature set-point (programmed by the operator) and the "Temp" value. The PID calculations are done separately for proportional, integral and derivative and then the individual terms are combined to generate a single PID output command. The proportional component is calculated by multiplying the error term with the proportional gain "Kp".

The integral term is used to eliminate any steady state error (error between the set-point and the steady process temperature for that specific set-point). The integral term is calculated as the sum of the value of the integral term in the previous program cycle; and the product of the error term, the cycle time of the PLC (dt in seconds) and the integral gain "Ki". The principle behind the integral component is to sum the error over time (according to the equation shown in the diagram) and use the value to influence the PID output command in order to drive the controlled variable towards the set-point. The integral term will either increase or decrease until the system reaches the set-point (depending on whether the controlled variable is above or below the set-point value). When the controlled variable reaches the set-point, the error term will become zero and the integral term will seize to increase or decrease. It is not practical to allow the integral term to grow indefinitely; therefore, an appropriate integral windup limit is introduced. If the result of the calculation of the integral term falls beyond the windup limit (in a negative or positive direction), the integral term is set equal to the limit as shown in figure 7. Setting the integral windup limit too high can result in a problem if the set-point command is modified considerably during process execution and the cycle time of the controller is small. At the moment that the set-point is altered, the integral will begin to wind up in the appropriate direction. If the process approaches the new set-point relatively slowly, the integral term could become excessively large and once the system reaches the new set-point, the integral term can introduce excessive overshoot due to the fact that the integral term must unwind before it is able to serve its purpose of eliminating the steady state error.

The derivative term is used to introduce damping into the system. The greater the rate of change of the controlled variable, the greater the derivative term becomes and alters the PID command appropriately. Referring to figure 7, the derivative term is calculated as the product of the rate of change of temperature (controlled variable) and the derivative gain "Kd". The rate of change of temperature is calculated as the difference between the process temperature during the current program cycle ("Temp") and the value of the process temperature during the previous program cycle ("Ptemp") divided by the time between those two temperature measurements ("dt" in seconds).

The PID output command is calculated as the sum of the nominal spindle speed, Proportional component "P" and the integral component "I" less the derivative component "D". The nominal spindle speed is the spindle speed which the operator estimates as the correct speed for the temperature set-point. Generally, this term could be excluded although it allows the integral windup limit to be smaller. Should it be excluded, the integral term would need to wind up to generate this "nominal" amount. By including this nominal amount, the integral windup limit can be smaller which will reduce overshoot in certain situations where the set-point is changed dramatically and the PLC cycle time is small (fast cycle time). The nominal amount and the suitable integral windup limit need to be determined from experimentation with the specific system which the tuner is tuning. An integral windup which is too small may result in a system which is unable to eliminate its steady-state error.

Conventionally, the derivative term is calculated using the rate of change of the error value instead of the rate of change of the controlled variable (temperature in this study). The reason for using the rate of change of temperature in this study is to eliminate any derivative spikes when the set-point command is changed during execution of the control process. Using the rate of change of the error term would introduce derivative spikes at the moment that the set-point is altered. During process execution where the set-point is constant, the magnitude of the rate of change of the error signal is equal to but opposite in sign to the rate of change of process temperature which is illustrated by figure 8. Referring to figure 8, consider that the temperature set-point is 500.08 oC and the PLC cycle time is 0.001 seconds. As the process temperature rises towards the set-point, the rate of change of the error signal is calculated using the red, solid lines and the calculation is shown in equation 1.

As the process temperature rises toward the set-point, the rate of change of the process temperature is calculated using the green, dashed lines (which extend to zero on the vertical axis) and the calculation is shown in equation 2.

If the rate of change of the error value is used, then the derivative term needs to be added to the PID sum instead of subtracting it as shown in figure 7. The final PLC operation before the controller command is sent to the spindle motor drive is a logical comparison in order to ensure that the spindle speed command is not greater than the maximum or less than the minimum allowable limits for the process to proceed safely. The algorithm illustrated by the flow diagram in figure 7 is executed every PLC program cycle.

4. Ziegler Nichols PID Tuning

The Ziegler Nichols tuning method10 is used to determine PID controller gains for a particular process based on the system's characteristics when it is subjected to a specific experiment. The experiment involves allowing the process controlled variable to oscillate around a commanded set-point. The integral and derivative gains are set to zero and the proportional gain is slowly increased from a small value until the system begins to oscillate with constant amplitude about the set-point. The tuner should take care when approaching the point of constant oscillation because increasing the proportional gain excessively can cause the system to become unstable resulting in system oscillation amplitudes tending towards infinity which could cause damage to the system (depending on the nature of the system). It is therefore good practice to program safe actuator maximum and minimum output values and overwrite the PID output value should it be beyond these limits. It is important to record the data values of the oscillation versus time because the period of the oscillation needs to be calculated for completing the method calculations. The proportional gain at the point of constant oscillation and the period of the oscillation are used to determine the Kp, Ki and Kd gains for the PID control system.

The tuning procedure is conducted in the following manner:

1. Set the controller integral gain (Ki) and derivative gain (Kd) to zero.

2. Set the proportional gain (Kp) to a very small value (close to zero).

3. Run the control system with a set-point command which is well within the operating range of the system.

4. Slowly increase Kp until the system begins to oscillate with constant amplitude about the set-point command. The proportional gain at this point (the value of Kp) is called the ultimate gain (Ku).

5. Measure and record the period of the oscillation (Tu) in seconds.

6. Calculate the controller gains using the following equations10:

The Ziegler Nichols tuning method effectively determines sufficient characteristics of the system in order to produce controller gains for the PID controller. The ultimate gain establishes the point where enough power is introduced into the system such that the system becomes undamped (the input power balances with the natural damping of the system). When a system becomes undamped, it will oscillate at its natural frequency which is the inverse of the oscillation period.

The procedure as outlined above was conducted on the FSW temperature control system. The graph of weld temperature and spindle speed versus time resulting from steps one to four is shown in figure 9.

figure 9

In the preliminary research work, it was determined that the safe limits for spindle speed on this particular weld setup were a maximum of 800 rev/min and a minimum of 300 rev/min. The weld temperature set-point for the tuning weld was set to 492 oC. As the weld was being executed, the proportional gain was increased from zero and the researcher managed to achieve system oscillation by approximately 145 seconds into the weld. By approximately 205 seconds into the weld, the researcher managed to achieve approximately constant temperature oscillation about the temperature set-point. In order to improve the accuracy of the Ku value, an additional tuning weld was conducted (AT_3) which began with the Kp value found at the end of weld AT_2. The weld graph for weld AT_3 is shown in figure 10.

figure 10

The ultimate gain (Ku) was establish to be 63.5. The period of the temperature oscillation (Tu) was found from the recorded weld data and was found to be 3.2059 seconds which is indicated on the graph shown in figure 11. Equation 6, equation 7 and equation 8 were developed according to equation 3, equation 4 and equation 5. The equations are designed to yield good response time with a small amount of overshoot.

figure 11

The PID controller gain values found in equation 6, equation 7 and equation 8 were tested with weld AT_4 and the response is shown in figure 12. The weld comprises two temperature set-points (490 oC and 540 oC) which were commanded during the weld. Heating and cooling to 490oC was tested showing good response. Heating to 540oC was tested although this temperature is considered the maximum which was achievable for this particular weld setup before over-plunging into the backing plate is experienced (welds were conducted with downward force control set to 20 kN).

figure 12

Should overshoot be more important than response time for a process, the Ziegler Nichols tuning method10 suggests alternative equations which will improve overshoot at the expense of some response time.

5. System Model Generation and Verification

A system model was generated using Matlab's system identification tool in order to be able to simulate the control system response. The system model was generated and the controller gains found from the Ziegler Nichols method were used in the simulation. The simulation response was compared to the actual weld response. The Matlab system identification tool is called from the Matlab command window using the ">>ident" command. The system identification tool requires an input and output set of data (with the sample time between data points) which is imported from the Matlab workspace. The input and output data are imported from the workspace as two separate vectors of the same length. The information used to create the vectors in the Matlab workspace could take the form of an Excel worksheet which is imported into Matlab using the import data function found under the "File" tab in Matlab. An open-loop experiment was conducted on the system; in which the spindle speed was stepped up from 500 rev/min to 600 rev/min and then back to 500 rev/min. The weld spindle speed and temperature is shown in figure 13. The section of weld data which was imported into Matlab was taken from 90 seconds to 170 seconds. The input data is the spindle speed step command. The output data is the weld temperature response to the spindle speed step.

figure 13

The system identification tool approximates a system model to fit the data. The order of the transfer function (system model) which is to be generated by the system identification tool is selectable. The accuracy of the model fit to the data is shown by the identification tool. The weld data is shown by the black, irregular line in figure 14. The system model generated by the system identification tool is shown by the red, smooth line in figure 14.

The transfer function is given a name in the system identification tool ("oe221" in this instance using the linear parametric model generator with OE structure). For more detail see Pothier6 about using the system identification tool. The model can be exported from the system identification tool to the Matlab workspace from which the transfer function can be called in the Matlab command window (see figure 15). The transfer function is given in its discrete form and was converted to its continuous form (using the ">>d2c" command) to be simulated in Matlab Simulink.

The Matlab Simulink control system diagram was set up as shown in figure 16 and the controller was labelled "Ziegler PID controller" since the controller gains set up in its properties were the ones found from the Ziegler Nichols method outlined in section 4.

figure 16

The control system was simulated and the response of the system, shown in figure 17, was found to be similar to the response of weld AT_7 which is shown in figure 18. The response data is tabulated in table 1 for comparison.

figure 17

figure 18

The damping ratio of a system is an important measurement which can be determined for most control systems and is a value which can be used during comparison of control systems. The damping ratio of the control system also shows if the system is optimally damped or is too underdamped or overdamped. For a second order system the overshoot and damping ratio are related by equation 9. The damping ratio can be made the subject of the formula which yields equation 10.

The control system is

a) Negatively damped if ζ < 0, resulting in an unstable system11

b) Undamped if ζ = 0, resulting in a system with constant oscillation11

c) Underdamped if 0 < ζ < 1, resulting in a system which is stable and percent overshoot ranges from high to low as ζ moves from zero towards unity 11

d) Critically damped if ζ = 1, resulting in a system which approaches the set-point as fast as possible as well as slow enough to achieve 0% overshoot 11

e) Overdamped if ζ > 1, resulting in a system which exhibits 0 % overshoot although increasing ζ increases the rise time of the system 11

Typically, a system is underdamped and this allows the system to have a good rise time with some acceptable overshoot. The weld response and simulation response fall into this category and their values are relatively similar as shown in table 2.

6. Control System Performance

Referring to weld AT_7 in figure 19, the system response is good in all regions. The system is commanded to three set-points during weld AT_7. The temperature set-points include 481 oC, 506 oC and 530 oC. The weld was executed and the first control system command was to heat to 481 oC; to which the system responded quickly with approximately 6oC of overshoot after which the system was in steady-state control for region one. The second command was to heat the weld zone to 506 oC which resulted in less overshoot (approximately 3 oC) after which the system was in steady-state control for region two. The third command was to heat to 530 oC which resulted in negligible overshoot after which the system was in steady-state control for region three. This suggests that a different set of controller gains for different portions of the temperature range could produce better control system response. The control system was tuned at 492oC and should have the best response around this temperature. Despite this suggestion, the response of the system is acceptable in the entire temperature range. The steady-state control about all three set-points can be considered acceptable.

figure 19

Cooling from region three to region four showed undershoot of similar magnitude to the overshoot experienced when heating from region one to region two although the temperature oscillated slightly when approaching steady-state condition. This also suggests that a different set of tuning for heating versus cooling may improve the system response for various transitions in the temperature range. The system response was acceptable regardless of this observation.

7. Derivative Filter Experimentation

From analysing the recorded control data it was observed that the excessive spindle speed oscillation which is present in most of the welds including weld AT_7 (shown in figure 19) is caused by the derivative term's contribution to the PID output. The derivative term tends to be sensitive to noise on the feedback signal. The reason for this is that the change in temperature of the weld from one program cycle to the next (one millisecond per program cycle) is small and the noise on the temperature signal is occasionally large in comparison. This results in an erratic derivative term. The noise (source of the problem), which was small and could be considered acceptable, was accentuated since the rate of change of temperature is multiplied by the derivative gain (Kd) to obtain the derivative term as shown in equation 11. Derivative filters were researched and tested. The researcher generated modified versions of the filter and these were tested. The derivative filter, which was researched, is available in Astrom and Murray12. The filter attenuates high derivative outputs (such as those generated by feedback noise). Implementing the derivative filter is done by replacing the derivative term in equation 11 with the new derivative term shown in equation 12.

Referring to equation 12, the principle behind the filter is that if is small, the denominator approximates unity and the derivative term generated is equivalent to the normal derivative in equation 11. If tends toward infinitely large, the derivative term approximates equation 13.

The attenuation of the derivative term versus the rate of change of the controlled variable (temperature) is shown in figure 20 for values of N = 2 and N = 20 (illustrated by the red and orange lines). The filter behaviour is shown relative to the unfiltered derivative term (linear black line). The modified version of the filter is given by equation 14 in which the term in the denominator has a power value introduced (r). The behaviour of the filter is modified by this term such that for large values of , the attenuation of the derivative term (D3) is more aggressive. The second modification is that the Ν term is no longer limited to 20 but is unlimited. This is necessary because the power term begins to generate large values as the rate of change of temperature increases which causes premature attenuation of the derivative term although a large power term (r value) is necessary to achieve the cut-off shape shown in figure 20 (green graphs which have the new r term in the label).

In order to shift the attenuation position to the right such that the attenuation occurs only for high rates of change of temperature (noise induced rates of change), the N value needs to be increased.

From figure 20 it is apparent that for low rates of change of temperature, the modified filter (r = 2.5; N = 300) closely approximates the unfiltered derivative although for large values of the rate of change of temperature, it has the most attenuation (for rates of change larger than approximately 28 oC/s). The tuner needs to be vigilant when selecting the r and N values because the attenuation needs to occur after the maximum possible rate of change of temperature of the system otherwise the system could become too underdamped, undamped or negatively damped which could cause system damage depending on the type of system.

The unmodified filter was tested using N = 20 in weld AT_8 shown in figure 21. The improvement in spindle speed oscillation was negligible over weld AT7 (see figure 19). The unmodified filter was not tested for N = 2 because the graph (figure 20) shows too much attenuation in the operating range of the process. Attenuating the derivative term excessively in the operating range of the process would defeat the objective of the tuning procedure which obtained the correct damping gain (Kd) in the operating range of the process.

figure 21

The modified filter was tested with the values shown in table 3. The attenuation curves for these filters are shown in figure 20. The temperature graphs of the two welds are shown in figure 22 and figure 23. The filter used in weld AR_1 improved the spindle speed oscillation (the system actuator oscillation).

figure 22

figure 23

8. Control System Robustness Testing

Thermal disturbances were introduced to welds which were conducted with a constant temperature set-point. Welds were conducted with a thermal sink disturbance and welds were conducted with a thermal source disturbance. Approximately half way from the start of the weld, the disturbance is introduced. Additional welds were conducted with constant spindle speed (temperature control disengaged) and with the disturbances present in order to generate a comparison graph which the control system needs to compensate for in the welds which have the control system engaged. An additional weld was conducted with the control system disengaged (constant spindle speed) and no disturbances present, for comparison. In this section, the welds which are discussed are numbered one to five and the details of those welds are shown in table 4. The thermal sink disturbance took the form of two aluminium troughs which were placed in contact with the weld plate (thermal paste was applied between the two) which were filled with dry ice (temperature of approximately -79oC 13) and methanol. The methanol (freezing point of approximately -97.7oC 14 which is below the temperature of the dry ice) improves the thermal conductivity between the ice itself and the trough, increasing the cooling effect dramatically. The thermal source disturbance took the form of two steel blocks which were in contact with the weld plate (thermal paste was applied between the two). The blocks were heated to approximately 400 oC in a furnace prior to welding.

Referring to figure 24, weld one showed that in the cooled region (the length of the troughs); there is a distinct drop in weld temperature relative to weld three which does not have a disturbance present. Weld two shows that with the temperature control engaged, the controller exhibits good disturbance rejection, maintaining the temperature set-point of 505 oC through the cooled region.

figure 24

The dry ice and methanol disturbance which was set up on the weld plate prior to execution of a FSW (figure 25).


Referring to figure 26, it is clear that as the weld tool approached and travelled through the cooled region, the controller increased the spindle speed in order to maintain constant weld temperature.

figure 26

Referring to figure 27, weld four showed that in the heated region (the length of the blocks); there is an increase in weld temperature relative to weld three which does not have a disturbance present. Weld five shows that with the temperature control engaged, the controller exhibits good disturbance rejection, maintaining the temperature set-point of 505 oC through the heated region. The heated block disturbance which was set up on the weld plate is shown in figure 28. Referring to figure 29, it is clear that as the weld tool approached and travelled through the heated region, the controller decreased the spindle speed in order to maintain constant weld temperature.

figure 27

figure 29


9. Conclusions

The work done illustrates a method for programming PID c ontrol on an industrial controller such as a PLC. The method could be extended to other programmable industrial controllers. Alterations of the method could be made to suit a process which is different to temperature control of FSW.

The Ziegler Nichols tuning method10 is shown to be a practical method for tuning an industrial control system. The method avoids many theoretical calculations for determining the process transfer function which could become complicated and inaccurate due to error accumulation. The tuning procedure requires modifying the controller gain until the system essentially becomes undamped which can be dangerous to the system depending on the nature of the system. Safety limits for the process actuator should therefore be programmed into the algorithm and the tuner should take care when approaching the point of non-stability. The Ziegler Nichols tuning10 equations presented in this paper generate controller gains which provide good system response time with a small amount of overshoot. Alternative Ziegler Nichols equations can be researched which reduce overshoot at the expense of rise time of the system; should your process require less overshoot.

Should it be a requirement to generate a mathematical model of the system, the Matlab system identification tool could produce such a model from a simple experiment which is conducted on the system. The tool generates a system model whilst avoiding complicated machine modelling from first principles which could become inaccurate due to accumulation of errors. This paper demonstrated that the system identification tool is able to generate a relatively accurate mathematical model of the system which when simulated; produces results similar to those produced from the actual process.

The control system performance section of this paper showed that overall; the PID control system response was good. The paper proposed that an alternative, more adaptive control method could improve the FSW control system response should it be necessary although the PID controller response can be considered acceptable in all regions of the control range investigated in this work.

The weld graphs from this research showed that the actuator could oscillate unnecessarily due to the derivative term of the PID controller being sensitive to the feedback signal noise. The derivative filter section of this paper suggests derivative filters which are designed to attenuate the component of the derivative term which is a response to the noise on the feedback signal.

The disturbance rejection of the PID controller was tested. Thermal disturbances were introduced to the system and the response of the PID controller was found to be excellent. The controller successfully modified the spindle speed in order to compensate for both thermal sink as well as thermal source disturbances. The PID temperature control system for FSW can be considered robust.

References

  • 1. Blignault C, A Friction Stir Weld Tool-force and Response Surface Model Characterizing Tool Performance and Weld Joint Integrity. Phd Thesis. Mechanical Engineering, Nelson Mandela Metropolitan University, South Africa, 2006.
  • 2. Hattingh DG, van Niekerk TI and Blignault C, Analysis of the FSW Force Footprint and its Relationship with Process Parameters to Optimise Weld Performance and Tool Design. Welding in the World. 2004, 48(1), 50-58.
  • 3. Hattingh DG, Blignault C, van Niekerk and James MN, Characterization of the Influences of FSW Tool Geometry on Welding Forces and Weld Tensile Strength Using an Instrumented Tool, Journal of Materials Processing Technology, 2008, 203(1-3), 46-57.
  • 4. Blignault C, Hattingh DG, Kruger GH, van Niekerk TI and James MN, Friction Stir Weld Process Evaluation by Multi-axial Transducer, Measurement, 2008, 41(1), 32-43.
  • 5. Hattingh DG, van Niekerk TI and Pothier RP, Closed-loop Temperature Control of Material Plasticisation during Friction Stir Welding, Advanced Materials Research, 2014, 1019, 120-125.
  • 6. Pothier RP, Closed-loop Temperature Control of Friction Stir Welding. Masters Dissertation, Nelson Mandela Metropolitan University, eNtsa, South Africa, 2015.
  • 7. Fehrenbacher A, Duffie NA, Ferri NJ, Pfefferkorn FE and Zinn MR, Effects of Tool-Workpiece Interference Temperature on Weld Quality and Quality Improvements Through Temperature Control in Friction Stir Welding, The International Journal of Advanced Manufacturing Technology, 2014, 71(1-4), 165-179.
  • 8. Terasrenki 2014 cdna.terasrenki.com/ds/6082_Aluminum Datasheet_1.pdf.
  • 9. Fehrenbacher A, Cole EG, Zinn MR, Ferrier NJ, Duffie NA and Pfefferkorn FE, Towards Process Control of Friction Stir Welding for Different Aluminum Alloys, In Friction Stir Welding and Processing VI, Editors Mishra R, Mahoney MW, Sato Y, Hovanski Y and Verma R, John Wiley & Sons, Hoboken, NJ, USA, 2011.
  • 10. Ziegler JG and, Nichols NB, Optimum Settings for Automatic Controllers, Transactions of the ASME, 1942, 64, 759-768.

11. Golnaraghi F and Kuo BC, Automatic Control Systems. 9th ed, John Wiley & Sons, 2009.

12. Astrom KJ and Murray RM, Feedback Systems: An Introduction for Scientists and Engineers. 2nd ed., Princeton University Press, New Jersey, 2012.

14. Cengel YA, Turner RH and Cimbala JM, Fundamentals of Thermal-Fluid Sciences, 3rd ed., McGraw-Hill, Singapore, 2008.

Received 5 November 2015
Revised form 26 April 2016
Accepted 29 April 2016

Publication Dates

  • Publication in this collection
    14 Jan 2025
  • Date of issue

History

  • Received
    05 Nov 2015
  • Reviewed
    26 Apr 2016
  • Accepted
    29 Apr 2016
location_on
South African Institution of Mechanical Engineering Research and Development Journal, University of Stellenbosch, Private Bag X1, Matieland, Cape Town, Western Cape Province, ZA, 7602, Tel: +27 21 808 4091 - E-mail: gillianc@sun.ac.za
rss_feed Acompañe los números de esta revista en su lector de RSS
Ir para arriba