Open-access Photovoltaic Panel Temperature and Power Output Analysis Tool

Abstract

The extensive use of photovoltaic (PV) systems to produce electricity due to the increase of fossil fuel cost and environmental consideration has become wide spread. The performance of a PV array is affected by temperature, solar insolation, shading, and array configuration. A MATLAB®-based modeling and simulation scheme is presented suitable for studying the current-voltage and power-voltage characteristics of a PV array under outdoor conditions and PV module physical component properties. The validity of the modeling approach was demonstrated by comparing its predicted operating temperature changes and system daily electrical energy produced with the measured data acquired from an experimental rig at the Energy Research and Development Center (ERDC) of Da-Yeh University in Taiwan. The predictions from the model show good agreement with the experimental measurements.

Photovoltaic module; thermal performance; outdoor; MATLAB®


1. Introduction

The performance of a PV module depends largely on the availability of solar radiation and on the conversion efficiency; these important features are affected by many physical parameters like the site latitude, the typical weather conditions, the panel tilt and azimuth angles, the air temperature, the wind speed, the temperature of the surrounding surfaces, the obstruction and shadow effects, the electrical load, etc.1

PV module manufacturers provide performance data for their products only for fixed standard conditions of solar irradiance and operating temperature. Indeed, sometimes, only a few electrical parameters (maximum power, maximum efficiency) are given1

In most cases, the PV panel will always operate far from these standard conditions. For this reason, it is very important to have a reliable model of the PV panel that is able to predict the electrical performance, even though the solar irradiance, the electrical load and the operating temperature do not correspond to the standard conditions1

Knowledge of the characteristic of a PV panel is a prerequisite for designing and dimensioning a PV power supply. This is the reason for the development of PV panel models useful for electrical measurement applications 22

Currently, photovoltaic generation systems are actively being promoted in order to mitigate environmental issues such as the green house effect and air pollution 3452 emission in urban centers 6

2. Modelling Of A PV Cell

The solar cell is the basic unit of a photovoltaic module and it is the element transforming the sun rays or photons directly into electric power 6

Solar cells consist of a p-n junction fabricated in a thin wafer or layer of semiconductor 786

Here Io is the reverse saturated current of the diode. When exposed to light, photons with energy greater than the band gap energy of the semiconductor are absorbed and create an electron-hole pair. These carriers are swept apart under the influence of the internal electric fields of the p-n junction and create a current proportional to the incident radiation 7

Being the net current of the cell, the difference of the photocurrent IL, (the current generated by the incident light, directly proportional to the sun irradiation) and ID (the normal diode current), as shown in equation 2 6

Shorting together the terminals of the cell (short circuit), as shown in figure 2a, the photon generated current (IL) will follow out of the cell as a short-circuit current (Isc).

Thus,

When there is no connection to the PV cell (open-circuit), the photon generated current is shunted internally by the intrinsic p-n junction diode. This gives the open circuit voltage Voc (see figure 2b).

The PV module or cell manufacturers usually provide the values of these parameters in their data sheets 9

Equations 1 to 3 give the net current of the solar cell. Equation 4 is the current-voltage relationship of the PV cell.

where V is the voltage across the PV cell and I is the output current from the cell. The reverse saturated current Io is constant under the constant temperature.

The process of modeling this solar cell can be developed based on equations 1, 2 and 4 66figure 3.

Setting the open-circuit condition as shown in figure 3, I = 0 and equation 4 becomes

To a very good approximation, the photon generated current, which is equal to Isc, is directly proportional to the irradiance G, the intensity of illumination, to PV cell 10

Thus, if the value, Isc=Iscr, is known from the data sheet, under the standard test condition, Go=1000 W/m2sc the photon generated current at irradiance G, the quotient of short-circuit currents over respective irradiances is equal to the constant of proportionality λ , thus

There are series resistances, parallel resistances and a recombination in the depletion region of the PV cell that have not been taken into account in the simple model and that will affect the performance of a PV cell in practice.

There is a series of resistances in a current path through the semiconductor material, the metal grid, contacts, and current collecting bus 11s).

There also parallel resistance also called shunt resistance. It is a loss associated with a small leakage of current through a resistive path in parallel with the intrinsic device 11p).

Recombination in the depletion region of PV cells provides non-Ohmic current paths in parallel with the intrinsic PV cell 12figure 4, this can be represented by the second diode (D2) in the equivalent circuit.

Adding the impact of RS,

and summarizing these effects, the current-voltage relationship of the PV cell is written as (equation 10)

The two-diodes equivalent circuit (and the corresponding double-exponential equation) is particularly suited for polycrystalline cells 13

And is represented by the single exponential model as shown in figure 5.

In equation 11, A is known as the "ideality factor" ("A" is sometimes also denoted as "n") and takes the value between one and two 12

However, the more accurate value is estimated by curve fitting. It can be estimated iteratively until an accurate value is achieved 7

3. Photovoltaic Panel Modeling

A single PV cell produces an output voltage less than 1 V, about 0.6 V for crystalline silicon (Si) cells, thus a number of PV cells are connected in series to archive a desired output voltage. When series-connected cells are placed in a frame, it is called as a module. Also, multiple modules can be wired together in series or parallel to deliver the voltage and current level needed. The group of modules is called an array. Most of commercially available PV modules with crystalline-Si cells have either 36 or 72 series-connected cells. A 36-cell module provides a voltage suitable for charging a 12 V battery, and similarly a 72-cell module is appropriate for a 24 V battery 14

When the PV cells are wired together in series, the current output is the same as the single cell, but the voltage output is the sum of each cell voltage.

The strategy of modeling a PV module is no different from modeling a PV cell. It uses the same PV cell model. The parameters are the same, but only a voltage parameter (such as the open-circuit voltage) is different and must be divided by the number of cells 1414

The equation describing the current-voltage relationship of the PV cell is given by

where I is the cell current (the same as the module current), V is the cell voltage = (module voltage/number of cells in series), T is the cell temperature in Kelvin (K).

First, calculate the short-circuit current (Isc) at a given cell temperature (T):

where Iscr at Tr is given in the data sheet (measured under irradiance of 1000 W/m2r is the reference temperature of the PV cell in Kelvin (K), usually 298 K (25 °C), a is the temperature coefficient of Isc in percent change per degree temperature, which is also given in the data sheet.

The short-circuit current is proportional to the intensity of irradiance, thus Isc at a given irradiance (G) is

where G is the nominal value of irradiance, which is normally 1000W/m2λ (A/Wm2

The reverse saturation current of a diode (Ior) at the reference temperature (Tr) is given by equation 6 with the diode ideality factor added

The reverse saturation current (Io) is temperature dependant and the Io at a given temperature (T) is calculated by the following equation 7

The diode ideality factor A is unknown and must be estimated. It takes a value between one and two; the value of n=1 (for the ideal diode) is, however, used until the more accurate value is estimated later by curve fitting 7sh acts on the voltage of the maximum power point (MPP) 2s was proposed by Gow and Manning, and consists in differentiating equation 12, evaluating it at open circuit conditions and rearranging it in terms of Rs 2

And from equation 17

Then, evaluate the equation 18 at the open circuit voltage that is V=Voc (also let I=0). The obtained equation is

and dl/dV is the slope of the I-V curve at the Voc (use the I-V curve in the datasheet then divide it by the number of cells in series), Voc is the open-circuit voltage of cell (found by dividing Voc in the datasheet by the number of cells in series).

Finally, it is possible to solve equation 12 for I-V characteristics. It is, however, complex because the solution for the current is recursive as a result of the inclusion of a series resistance in the model. Although it may be possible to find the answer by simple iterations, Newton's method is chosen for accelerated convergence 7

The Newton's method is described as:

where: f '(x) is the derivative of the function f(x)=0 , xn is a present value, and xn+1 is a next value.

Rewriting equation 21 gives the following function

After substitution into equation 20 the output current I can be computed iteratively.

The open circuit voltage increases logarithmically with the ambient irradiation, while the short circuit current is a linear function of the ambient irradiation 1515

4. PV Module Temperature

In the following a simple energy and exergy analyses of the simultaneous generation of heat and power by PV technology is presented 16

The principle of a solar cell can be considered as an ideal simple situation in which the sun irradiates the flat surface of the solar cell on the surface of the earth 16figure 7 16

The irradiation that reaches the flat surface of a PV module is decomposed in reflected and refracted components. A part of the refracted component is absorbed by the front glazing and the other is transmitted to the solar cells and the back surface.

Only the part transmitted to the solar cells contributes to produce electricity while the part transmitted to the back surface heats the solar cells. Finally a component of energy is lost by conduction and radiation.

To determine temperatures need for simulation of solar module, the energy balance was applied to each component.

4.1 Front glazing

Consider the front glazing of the PV module reached by irradiance G as shown in figure 8.

The energy balance yields

where ρg is the density of front glazing, δg is the thickness of the front glazing, Cg is the capacity heat of the front glazing, Tg is the temperature of front glazing, t is the time, Gabs,g is the irradiation absorbed by the front glazing, Hcond,g is the conduction heat in the front glazing, Hconv,g and Hrad,g are respectively the convection heat and the radiation from the top of front glass to ambient.

4.2 Solar cells

For the solar cells, the irradiance Gtrans,c transmitted from the front glazing to solar cells is converted into energy Gabs,c absorbed by solar cells and heat what is lost at the top and back sides of solar cells. Considering the energy exchange indicated in figure 9 we obtain equation 25

where pc is the density of solar cells, 5c is the thickness of solar cells, Cc is the heat capacity of the solar cells, Gtrans,g-c the energy from the front glazing absorbed by solar cells, Hcond,b is the conduction heat in the back surface, E is the output electrical energy.

4.3 Back surface

Figure 10 shows the input and output energies for the back surface of a PV module. Using the same principles as for the previous two cases, we obtain the equation (26)

where pb is the density of back surface, 5b is the thickness of back surface, Cb is the heat capacity of back surface, Tb is the temperature of back surface Gtrans,g-b is the energy transmitted from front glazing to back surface, Hconv,b and Hrad,b is respectively the convection heat and the radiation from back surface to ambient.

For steady state; equations 24 to 26 become

- Heat transfer from solar cells to top of front glazing:

- Heat transfer from top of front glazing to ambient:

- Heat transfer front glazing to ambient by radiation:

- Solar energy transmitted to solar cells:

- Solar energy absorbed by solar cells:

- Photovoltaic module output electrical energy:

- Solar energy transmitted to the back surface:

- Solar energy absorbed by the back surface:

- Heat transfer from top of back surface to ambient:

- Heat transfer from back surface to ambient by radiation:

The solar energy transmitted by the glass to the solar cells and the back surface thus consists of two components:

From equations (4), (5), (6) and neglecting radiation heat transfer from both surfaces to ambient, we obtain the system of equations below:

And solving equation (20), we obtain the solar cell temperature

Where:

- Front glazing dimensionless coefficient:

Heat transfer coefficient from solar cells to top of front glazing:

Heat transfer coefficient from solar cells to back side of back surfac

And the convective heat transfer coefficient under wind is given by (Watmuff et al., 1977)17

It is well-known that most of the solar radiation absorbed by a photovoltaic (PV) panel is not converted to electricity but contributes to increase the temperature of the module, thus reducing the electrical efficiency. All these effects must be considered in any model for photovoltaic module efficiency 18

The most known model is given by the following equation:

where ηr is the reference module efficiency at a PV cell temperature Tr of 25 °C and at a solar irradiance Go on the module equal to 1000 W/m2c and γ are, respectively, the temperature and the solar irradiance coefficients for the PV module 18-1 and 0.12, respectively, for silicon modules. The latter, however, is usually taken as zero, so that equation (51) reduces to

Which represents the traditional simple linear expression for the PV electrical efficiency 19

where

Evans suggested using λc = 0.0048C-1 for a silicon module20

From equations (51) and (52) we obtain the cell temperature, front glass and back surface temperature given below.

4.4 Other methodologies

In the following we briefly comment on other methodologies previously developed and point to their limitations. The performance of a photovoltaic module is studied versus environmental variables such as solar irradiance, ambient temperature and wind speed. The most common manner to determine the cell temperature Tc consists in using the Normal Operating Cell Temperature (NOCT) developed by Nolay P. in 1987 21c is then dependent on the ambient temperature Ta and on the solar irradiance G according to equation below:

This simple method yields satisfying results if the PV modules are not roof-integrated 18

In 2006 Mattei et al.18

This simple model used a simple energy balance and neglecting the radiation effects and was developed with the PV module alone, i.e. without the absorber, the glass and the insulation.

In 2008, Skoplaki et al.19

They explicitly involve the three basic and readily available environmental variables, namely, solar irradiance, ambient temperature, and wind speed, as well as a dimensionless mounting parameter that is a measure of the integration level of a given installation. The proposed correlation ignores free-convection influences, which are small for all wind speeds, and radiation losses, which are important only at wind speeds of below 1 m/s and, therefore, should be used for wind speeds exceeding this.

The proposed model accounts for free convection for wind speed up to 1 m/s, and physical properties for different components of PV module, particularly the conduction heat transfer coefficients of the front glazing, the PV cells and the back insulation property that allow the PV module to be easily and quickly cooled. Like the three models above, our proposed correlation ignores the PV radiation heat transfer. Our model is simple and user friendly and does not refer to the NOCT.

5. SIMULATION AND VALIDATION

5.1 Model simulation

The mathematic model of PV module temperature is established and this behavior against the temperature change studied by analysis and comparison of different curves and numerical values for temperature and power output22

To simulate the PV module, a MATLAB® code based on a complete model of PV module that provides tables and graphs was written. This model combines both PV electricity model and thermal model and the equations of both electrical characteristics and thermal dynamic are implemented using MATLAB ® codes.

5.2 Experimental validation

To evaluate the cell temperature and output power of the proposed model, experimental data from Da-Yen University was used. The experimentation was done using the commercial Siemens SM46 PV module (see table 1) for different parameters such as sunlight irradiation, ambient temperature, and wind speed in real working conditions. The experiment setup consists of a Siemens SM46 PV module, MPPT controller (SunSaver-10), storage battery, electric fan as a load, and some instrument. The experiment rig was set up in the Energy Research and Development Center (ERDC) of Da-Yeh University in Taiwan23

5.3 Measurement results and model validation

All observations of sunlight irradiance, temperatures, operating voltage and output currents of the SM46 PV module were recorded at 5-min intervals 23

Taking a typical cloudy day (2011/07/07), the weather variations are depicted in figure 11.

Based on the local weather conditions, the simulated cell temperature of the proposed model and the measured cell temperature are depicted in figure 12a. The results strongly indicate that the simulated cell temperature has a positive bias away from the measured temperature and the simulated cell temperature has a better agreement.

Figure 12b demonstrates the measured operating voltage and output current of the SM46 PV module. The corresponding values of both simulated and measured current at the measured voltage are also depicted in figure 12b.

Figure 12c illustrates the associated output power. It is apparent that both simulated current and power have a better agreement with those measured.

For a typical sunny day (2011/07/08), the weather conditions are shown in figure 13. Both simulated and measured cell temperatures are shown in figure 14a. The agreement between simulated cell temperature and measured temperature is getting worse and a positive bias of temperature difference between the simulated cell temperatures and measured cell temperature is demonstrated.

The root mean square (rms) of the temperature differences are calculated and listed in table 2. In addition, the root mean square operations of the output current and power differences are also calculated and listed in table 2. The simulated results of the integrated thermal dynamics and electricity PV model have a close agreement with the measurement for both cloudy and sunny weather conditions.

6. CONCLUSIONS

The PV module temperature model combined with the electrical model was simulated and results were compared to experimental results for typical cloudy day and typical sunny day.

The simulated output characteristics of the proposed PV model is generally close to operating module with better accuracy, which has been validated through short period of experimental measurement under real operating conditions.

The study shows that a model that takes account of irradiance, environmental parameters and physical properties of a PV module can be used as a powerful tool for design, parameter analysis and diagnostic of commercial as well as do-it-yourself (DIY) PV modules under outdoor conditions.

It can also be used for developing and evaluating new maximum power point tracking techniques and to study the effects physical components have on PV panels with different configurations.

The proposed model takes into account not only irradiance and meteorological conditions, but also the physical properties of materials used in the manufacture of a PV module which makes the model much more flexible in the prediction of the production of energy for commercial PV as well as DIY in field conditions.

Based on a verified PV model, this available information can be further used for predicting the PV output characteristics and for further model-based diagnosis applications.

ACKNOWLEDGEMENTS

The authors are thankful to Prof. Huan-Liang Tsai from Da-Yen University for providing experimental data, CEPS and DVC Research Prof. Nelson Mutatina Ijumba for their financial assistance for the project.

REFERENCES

  • 1. Lo Brano V, Orioli A, Ciulla G and Di Gangi A, An improved five parameter model for photovoltaic modules, Journal Of Solar Energy Materials & Solar Cells, 94, 21 April 2010, 1358-1370.
  • 2. Adamo F, Attivissimo F, Di Nisio A, Lanzolla AML and Spadavecchia M, Parameters estimation for a model of photovoltaic panels", XIXIMEKO World Congress, Fundamental and Applied Metrology, Lisbon, Portugal, September 6-11, 2009, 964-967.
  • 3. El Shahat A, PV cell module modeling & ANN simulation for smart grid applications, Journal of Theoretical and Applied Information Technology, 2010, 9-20.
  • 4. [s.n.], \Trends in Photovoltaic Applications: Survey Report of Selected IEA Countries Between 1992 and 2006, International Energy Agency, 2007, 36 pages.
  • 5. Markvart T and Castaner L, Practical Handbook of Photovoltaic: Fundamentals and Applications, Elsevier, 2003.
  • 6. Hernanz RJA, Martin CJJ, Belver ZI, Lesaka LJ, Guerero ZE and Perez PE, Modeling of photovoltaic module, International Conference on Renewable Energies and Power Quality (ICREPQ'10), Granada (Spain), 23th to 25th March, 2010, 5 pages.
  • 7. Walker GR, Evaluating MPPT converter topologies using a MATLAB ® PV model, Australasian Universities Power Engineering Conference (AUPEC), Brisbane, 2000, 6 pages.
  • 8. Keyhani A, Marwali MN and Dai M, Integration of Green and Renewable Energy in Electric Power Systems, John Wiley & Sons, January 2010.
  • 9. Masters GM, Renewable and Efficient Electric Power Systems, John Wiley & Sons Ltd, 2004.
  • 10. Messenger R and Ventre J, Photovoltaic Systems Engineering, 2nd edition, CRC Press, 2003.
  • 11. Castañer L and Silvestre S, Modeling Photovoltaic Systems Using PSpice, John Wiley & Sons Ltd, 2002.
  • 12. Green MA, Solar Cells: Operating Principles, Technology and System Applications, Prentice Hall Inc, 1982.
  • 14. Oi A, Design and Simulation of Photovoltaic Water Pumping System, MSc Thesis in Electrical Engineering, California Polytechnic State University, September 2005.
  • 15. González-Longatt FM, Model of photovoltaic module in MATLAB ® ", 2Do Congreso IBEROAMERICANO De Estudiantes de Ingeniería Eléctrica, Electrónica y Computación (II CIBELEC 2005), 2005, 5 pages.
  • 16. Petela R, Engineering Thermodynamics of Thermal Radiation for Solar Power Utilization, McGraw-Hill, 2010.
  • 17. Watmuff JH, Charters WWS and Procter D, Solar wind induced external coefficients for solar collectors, COMPLES 2, technical note 1977, page 56.
  • 18. Mattei M, Notton G, Cristofari C, Muselli M and Poggi P, Calculation of the polycrystalline PV module temperature using a simple method of energy balance, Renewable Energy, 31, 2006, 553-567.
  • 22. Mutombo NMA and Inambao FL, Temperature evaluation and energy estimation of photovoltaic module by simulation, Proceedings of 12th Botswana Institution of Engineers Biennial Conference, CD Rom, 14-16 September, 2011, Gaborone, Botswana, 2011, 249-254.

Received 13 January 2012
Accepted 28 July 2012

Publication Dates

  • Publication in this collection
    25 Nov 2024
  • Date of issue

History

  • Received
    13 Jan 2012
  • Accepted
    28 July 2012
location_on
South African Institution of Mechanical Engineering Research and Development Journal, University of Stellenbosch, Private Bag X1, Matieland, Cape Town, Western Cape Province, ZA, 7602, Tel: +27 21 808 4091 - E-mail: gillianc@sun.ac.za
rss_feed Acompañe los números de esta revista en su lector de RSS
Ir para arriba