Open-access Rotary regenerator design theory and optimisation

Abstract

A review of the simplest and most frequently used design theory for counterflow rotary regenerators is given. A new correlation for the effectiveness of a balanced regenerator is proposed. A computer program was written for the thermal evaluation and design of counterflow rotary regenerators. The program is used to optimise some of the operating conditions and design parameters if the effectiveness is specified. It is shown by an example how the disk rotational speed, flow split ratio and matrix wall thickness can be optimised. Five heating surfaces that were experimentally tested for their heat transfer and pressure drop characteristics are compared at their respective optimum operating points.


Introduction

Since its invention the development of the rotary regenerator has been continuous, covering the principles of thermodynamics, fluid mechanics and structural engineering. The idea of using a slowly rotating drum containing a tightly packed heating surface matrix to transfer heat between two gas streams is still the basis of present-day designs. Today the rotary regenerator is a carefully engineered product which is highly reliable. The diameter of the drum can range from 350 millimetres to more than 15 metres. This causes the heating matrix to weigh anything from a few kilograms to several hundreds of tons.1 2 is presented.

Design theory for counterflow regenerators

To date, no complete solution for the differential equations governing the heat transfer process in a regenerator exists. The differential equations are subject to the

normal idealisations made in the design theory. The idealisations are Usted by Shah34 (ε-Ntuo) or the reduced length - reduced period (A-II) methods of solution. The ε-Ntuo method is usually used for rotary regenerators and the A-II method for fixed matrix regenerators. This paper will focus on the ε-Ntuo method. It can be shown that the effectiveness of a counterflow regenerator is a function of six dimensionless variables.3

The most important assumption in the derivation of the above relation is that there is no pressure or carry over leakage. In a direct contact type recuperator the effectiveness is only a function of Ntu and C*. The parameters (hA)* and arise because of the heat storing nature of a regenerator. The longitudinal heat conduction effect is accounted for by A and . An advantage of this particular choice of dimensionless parameters is that the influence of (hA)* and on the effectiveness are small and that the solution method parallels that of a recuperator for the case of infinite (infinite rotational speed). A program was written to solve the effectiveness as a function of the six above-mentioned parameters. The numerical scheme of Bahnke & Howard4

Approximate solutions for an ideal regenerator

If the assumption is made that there is no pressure or carry over leakage, the regenerator is said to be 'ideal'.

Solutions for the case of zero longitudinal heat conduction

In the case of zero longitudinal heat conduction the functional relationship for the effectiveness (equation 1) becomes:

For the special case of infinite rotational speed, i.e. = ∞ an analytical solution is available. The effectiveness is given by the well-known relation,

For C* = 1 equation (3) reduces to: ε = (Ntuo) / (1 + Ntuo)- The above relation is identical to that of an indirect contact type recuperator. Lambertson2. Kays & London6 from 1.87 to 1.93.

where ε∞ is calculated from equation (3).

Razelos6(C* < 1) regenerator. He disregarded the influence of (hA)* in the range 0.25 < (hA)* < 4. The specified values of Ntuo, C* and are used to calculate Ntuo,e and for an equivalent balanced regenerator (C* = 1).

Therefore the effectiveness of the balanced regenerator using in eq. (4) is:

The method by Razelos6o numbers. Numerical results for a balanced, symmetric regenerator (C* = (hA)* = 1) for the complete range of > 1 and 0.5 < Ntuo < 500 were used to extend eq. (4) for C* = 1 as follows:

Eq. (7) agrees with numerical results within 0.25 % for the range > 1.5 and 0.5 < Ntuo,e, < 500 and within 0.7 % for > 1 and 0.5 < Ntuo,e < 500. The largest error is 0.69 % and occurs at =1.5 and Ntuo,e = 80.

The, effectiveness of the unbalanced regenerator is calculated from:

Baclic7C* = (hA)* = 1. The Baclic equation7o numbers and C* = 1. At Ntuo = 500 the error is 0.3 %. The method can however be extended to produce answers to the desired accuracy. The method is not for hand calculation and the computing time needed is similar to that of finite difference methods. It is therefore not well suited if one is interested in optimisation. The solution is a long one and will not be presented here.

The method by Razelos6C* = 1 to extend the results to C* < 1 for (hA)* = 1. This was done in order to establish how well the method of Razelos6C*. Predictions agree with numerical results within 1 % in the following ranges:

The influence of (hA)* has not been taken into account by any of the approximate solutions thus far. Usually it is quoted that the influence of (hA)* is small in the range 0.25 < (hA)* < 4 and the results are then given for (hA)* = 1. Numerical results were calculated by the author for (hA)* = 0.25 and 4 and it was found that the deviation in the effectiveness is less than 1% in the following ranges:

Effect of longitudinal heat conduction

The effect of longitudinal heat conduction is to reduce the regenerator effectiveness for a specified Ntuo. Two additional dimensiónless parameters, λ and now play a role. The following method was recommended by Shah8

The effectiveness ratio in brackets is for a balanced recuperator. It is therefore postulated that the same ratio can be applied to unbalanced regenerators. The solution for the effectiveness of an unbalanced recuperator, including the effect of longitudinal heat conduction was first given by Hahnemann94

Romie10o is replaced by GLNtuo in the calculations for zero longitudinal heat conduction. The factor GL is derived from recuperator analysis and is given by:

For C* = (hA)* = 1 it reduces to GL = . Good agreement was noted when the above method was compared to numerical results in the following range of parameters: 1 <

Effect of transverse heat conduction

An equivalent thermal resistance is added to the convective resistances in the expression for Ntuo to account for the effect of wall resistance. Hausen11

Approximate solution method for an ideal regenerator

The following procedure is adopted and the predictions are in good agreement with numerical results.

1. The six dimensionless parameters are calculated from the known design parameters and operating conditions. Ntuo already includes the effect of transverse heat conduction.

2. The longitudinal heat conduction correction factor, Gl is calculated from eq. (10). Ntuo is corrected by replacing it with GlNtuo, Bahnke &Howard4

3. The parameters Ntuo,e and for an equivalent balanced regenerator are evaluated using eq. (5).

4. The effectiveness of the equivalent balanced regenerator is calculated using eq. (7).

5. The effectiveness of the original unbalanced regenerator is finally calculated from eq. (8).

We have now established an approximate method that can be compared to numerical results. The comparison was done with good agreement noted over the following range of parameters:

Influence of pressure- and carryover leakage

Pressure leakage is the flow of gas past the seals from the cold side to the hot side. The driving force is the pressure difference between the cold gas stream and hot gas stream. The carry-over leakage refers to the transportation of gas trapped in the matrix void volume from the one side into the opposite gas stream owing to matrix rotation. Shah12

Pressure drop evaluation

The expression for evaluating the pressure drop across a plate fin heat exchanger is given by Kays & London.5

Often in heat exchanger pressure drop analysis, the exit and entrance losses are accounted for in the friction factor. Eq. (14) then becomes:

Here fe is an effective friction factor.

Design optimisation

In this section it will be shown how the operating conditions can be optimised in a specific application using a particular heating surface. Afterwards five heating surfaces will be compared to each other at their respective optimum operating points. The heating surfaces were experimentally tested for pressure drop and heat transfer characteristics. The surfaces were tested at different spacings. The comparison will be done at a single spacing.

A PC software package was written for the thermal evaluation and design of a counterflow rotary regenerator. The program consists of two parts, namely, (1) Evaluation or Rating and (2) Optimisation of the Design. In order to rate a regenerator, it is required that the designer specifies the operating conditions (mass flow rates, inlet temperatures, inlet pressures, disk rotational speed), rotating disk dimensions (outer diameter, hub diameter, disk height, ratio of area split between hot and cold fluid) and the matrix properties (plate spacing, wall thickness, material thermophysical properties, heat transfer and pressure drop correlations for the matrix). The program then calculates the outlet gas temperatures, the total heat transfer rate, and the pressure drop across the regenerator.

In order to optimise the design the overall effectiveness or equivalently the total heat transfer rate desired is specified. The disk rotational speed, the hot to cold fluid flow split ratio and the matrix wall thickness are then varied. At each combination of the varied parameters the disk height is calculated that will deliver the required heat transfer rate.

Note: The disk outer diameter was not taken as an optimisation variable, because it was found that the largest possible frontal area always produces the most cost effective answer. It is therefore up to the designer to specify the largest possible outer diameter for the rotating disk which can be practically implemented in a system.

For illustrative purposes a single regenerator application was investigated. The regenerator data and operating conditions were obtained from Leong et al.13

Input data

Operating conditions

Cold gas inlet mass flow rate, Wc = 109 kg/s

Hot gas inlet mass flow rate, Wh = 109 kg/s

Cold gas inlet temperature, Tc,i = 337 K

Cold gas inlet pressure, pc,i = 106.21 kPa

Hot gas inlet temperature, Th,i = 580.5 K

Hot gas inlet pressure, Ph,= 102.28 kPa

Pressure leakage fraction, xp = 0.08 of cold gas flow rate

Disk dimensions

Disk outer diameter, D = 7.863 m

Hub diameter, Dhub = 2.237 m

Seal face coverage fraction, xs = 0.1 of total frontal area

Matrix properties

Plate spacing, s = 5 mm

Matrix wall thickness, δ= 0.5 mm

Matrix wall thermal conductivity, kw = 51.9 W/mK

Matrix wall density, ρw = 7817 kg/m3

Matrix wall specific heat, cw = 434 J/kgK

Ratio of actual surface area to projected area, α = 1.2

Other input parameters like the porosity, σ, the surface area density, ß, and the effective mass of the matrix, m, can be calculated if the plate spacing, the plate thickness, the matrix wall density and αare known.

Optimisation of operating conditions

The disk rotational speed, the hot to cold gas flow split ratio and the plate thickness were varied in the optimisation process to arrive at their optimum values for a particular type of heating surface. The required effectiveness was specified as 75 %. The heat transfer and pressure drop correlations for the matrix used were:

The correlations are only valid for a plate spacing (not the pitch) of 5 mm, but for any porosity, a, and disk height, L.

Discussion

(i) Effect of disk rotational speed and matrix wall thickness

The effectiveness of an ideal regenerator (no pressure-or carry-over leakage) increases with an increase in rotational speed and asymptotically approaches that of a recuperator as predicted by eq. (4). This is also evident from numerical results. However, in an actual regenerator, an increase in rotational speed increases the gas carry-over which in turn reduces the regenerator effectiveness. These two effects oppose each other. The effectiveness first increases with an increase in rotational speed and then decreases indicating an optimum value at some rotational speed. If the effectiveness is held constant as was done in this case the required surface area or disk height will show a minimum at some rotational speed. In Figure 1 it can be seen that there is a minimum disk height for every plate thickness as the disk rotational speed is increased. Three matrix wall thicknesses, namely 0.3, 0.5 and 0.7 mm were investigated. The optimum disk rotational speed is defined as the speed that requires the minimum disk height for a specified effectiveness.

In the literature it is indicated that regenerators usually operate at rotational speeds of 1 to 3 r.p.m.14,15,16 For this example the optimum speeds are in the same range. The disk rotational speed is the most important optimisation variable if the regenerator matrix is fixed. The disk height increases drastically if the rotational speed is lowered beyond a certain value. The designer must be certain that the rotational speed is high enough to avoid this situation, but within limits to avoid excessive fluid intermixing.

(ii) Effect of the flow split ratio

A flow split ratio of 1.14 was used in Figure 1, being the optimum value obtained in the optimisation process. It was found that the flow split ratio does not have a significant influence on the minimum disk height or the rotational speed where this height occurs. The effect of a change in the flow split ratio on the regenerator effectiveness is mainly reflected by changes in the dimensionless groups (hA)* and . It was noted earlier that the two above-named dimensionless groups do not have a significant influence on the regenerator effectiveness and can practically be eliminated from the solution process. The optimum disk height increased from 3.68 m to 3.69 m as the flow split ratio was increased from 1 to 1.2. For practical purposes this is insignificant.

A more important role that the flow split ratio plays in the optimisation process is to balance the pressure drop for the hot and cold sides. Figure 2 shows how the hot and cold side pressure drop are influenced by the flow split ratio. It can be seen that the pressure drops are balanced near the optimum ratio of 1.14. This has the advantage of reducing the overall fan sizes needed to supply the gas.

Heating surface selection

Five heating surfaces that were experimentally tested for their pressure drop and heat transfer characteristics will be compared at their respective optimum operating conditions. The heating surfaces are numbered from 1 to 5. Surface number 1 is a plain flat surface. Surfaces 2 - 5 have wavy patterns to enhance the heat transfer. They are numbered in order of increasing heat transfer coefficient. Number 5 thus has the highest heat transfer coefficient. Surface number 2 was used to illustrate the optimisation of the operating conditions. For this range of surfaces it was found that the ratio h/f decreased as the heat transfer coefficient was increased. If this ratio is taken as the only performance criteria, the flat surface seems to be the best choice. The physical size and operating costs are two additional factors that the designer will have to consider.

Figure 3 shows a comparison of the required disk height for the five surfaces. The results are shown at the optimum rotational speed for each surface. The heat transfer rate and operating conditions are the same for all the surfaces. The size of a regenerator fitted with the flat surface, will exceed that of any of the enhanced surfaces by far. The plate thickness does not have a significant influence on the required disk height.

Figure 4 shows the average pressure drop for the five different matrixes. It can be seen that although surface number 1 (the flat surface) requires the largest disk dimensions, its pressure drop is the lowest. Surface number 5 which requires the least matrix material, has the highest pressure drop. The pressure drop increases slightly with an increase in plate thickness.

Figure 5 shows the disk rotational speed at the minimum disk height for each matrix. One of the major disadvantages of a rotary regenerator is the intermixing of the two gas streams. In applications where this is not allowable, a rotary regenerator can not be used. A large disk height and a high rotational speed contribute to intermixing. It is interesting to note that in the cases where the disk height is the largest, the rotational speed is the lowest, This is an advantage, since it helps to limit gas intermixing.

Concluding remarks

It was shown how the some of the operating conditions of a rotary regenerator can be optimised for a particular choice of matrix. To choose a matrix that is best suitable for an application is perhaps more difficult. The regenerator dimensions and pressure drop vary drastically with choice of matrix. The final selection in most cases will have to be made after an economic evaluation. A detailed cost analysis will have to be carried out, taking into account the capital and operating costs of the regenerator over its life span.

Such an analysis falls beyond the scope of this work. The spacing between the sheets is another important design parameter. Although the results were presented for a spacing of 5 mm, the surfaces were tested at spacings of 3.5 and 3 mm as well.

References

  • 1. Warren I. Ljungstrom Heat Exchangers for Waste Heat Recovery. Heat Recovery Systems, 2, 1982, 257-271.
  • 2. Lambertson TJ. Performance Factors of a Periodic-Flow Heat Exchanger. Trans. ASME, 80, 1958, 586-592.
  • 3. Shah RK. Thermal Design Theory for Regenerators. In Heat Exchangers: Thermal Hydraulics Fundamentals and Design, (eds) S Kakaç, AE Bergles & F Mayinger, 721-763. Hemisphere, Washington, DC, 1981.
  • 4. Bahnke GD &Howard CP. The Effect of Longitudinal Heat Conduction on Periodic-Flow Heat Exchanger Performance. J Eng. Power, 86A, 1964, 105-120.
  • 5. Kays WM &London AL. Compact Heat Exchangers,, 2nd edn. McGraw-Hill, New York, 1984.
  • 6. Razelos P. An Analytical Solution to the Electric Analog Simulation of the Regenerative Heat Exchanger with Time-Varying Fluid Inlet Temperatures. Wärme und Stoffübertrag, 12, 1979, 59-71.
  • 8. Shah R.K. A Correlation for Longitudinal Heat Conduction Effects in Periodic-Flow Heat Exchangers. J Eng. Power, 97A, 1975, 453-454.
  • 9. Hahnemann HW. Approximate Calculation of Thermal Ratios in Heat Exchangers Including Heat Conduction in Direction of Flow. National Gas Turbine Research Establishment Memorandum No. 36, TPA3/TIB, Ministry of Supply, Milibank, London, SWI, 1948.
  • 10. Romie FE. Treatment of Transverse and Longitudinal Heat Conduction in Regenerators. J Heat Transfer, 113, 1991, 247-249.
  • 11. Hausen H. Heat Transfer in Counterflow, Parallel flow and Cross Flow, 2nd edn. McGraw-Hill, New York, 1983.
  • 12. Shah RK. Counterflow Rotary Regenerator Thermal Design Procedures. In Heat Transfer Equipment Design, (eds) RK Shah, EC Subbarao &RA Mashelkar, 267-296. Hemisphere, New York, 1988.
  • 14. Gram AJ &Kessler GW. New Regenerative Air Heater. Mechanical Engineering, 1966, 45-47.
  • 15. Chung-Hsiung Li. A Numerical Finite Difference Method for Performance Evaluation of a Periodic-Flow Heat Exchanger. Journal of Heat Transfer, 105, 1983, 611-617.

16. Woodruff EB, Lammers HB k Lammers TF. Steam Plant Operation, 5th edn. McGraw-Hill Book Company, New York, 1984.

Received June 1995
Final version September 1996

Publication Dates

  • Publication in this collection
    09 July 2024
  • Date of issue

History

  • Received
  • Accepted
location_on
South African Institution of Mechanical Engineering Research and Development Journal, University of Stellenbosch, Private Bag X1, Matieland, Cape Town, Western Cape Province, ZA, 7602, Tel: +27 21 808 4091 - E-mail: gillianc@sun.ac.za
rss_feed Stay informed of issues for this journal through your RSS reader
Go to top