Open-access Sensitivity and specificity of malaria rapid diagnostic test (mRDT CareStatTM) compared with microscopy amongst under five children attending a primary care clinic in southern Nigeria

Abstract

BACKGROUND: Malaria diagnosis using microscopy is currently the gold standard. However, malaria rapid diagnostic tests (mRDTs) were developed to simplify the diagnosis in regions without access to functional microscopy. AIM: The objective of this study was to compare the diagnostic accuracy of mRDT CareStatTM with microscopy. SETTING: This study was conducted in the paediatric primary care clinic of the Federal Medical Centre, Asaba, Nigeria. METHODS: A cross-sectional study for diagnostic accuracy was conducted from May 2016 to October 2016. Ninety-eight participants were involved to obtain a precision of 5%, sensitivity of mRDT CareStatTM of 95% from published work and 95% level of confidence after adjusting for 20% non-response rate or missing data. Consecutive participants were tested using both microscopy and mRDT. The results were analysed using EPI Info Version 7. RESULTS: A total of 98 children aged 3-59 months were enrolled. Malaria prevalence was found to be 53% (95% confidence interval [CI] = 46% - 60%), whilst sensitivity and specificity were 29% (95% CI = 20% - 38%) and 89% (95% CI = 83% - 95%), respectively. The positive and negative predictive values were 75% (95% CI = 66.4% - 83.6%) and 53% (95% CI = 46% - 60%), respectively. CONCLUSION: Agreement between malaria parasitaemia using microscopy and mRDT positivity increased with increase in the parasite density. The mRDT might be negative when malaria parasite density using microscopy is low.

family medicine; primary care; education; mRDT; parasite density; sensitivity; specificity


Introduction

Background

Malaria is one of the leading causes of morbidity and mortality worldwide, especially in under 5-year-old children and pregnant women in sub-Saharan Africa, where over 80% of cases and at least 90% of malaria deaths occur.1,2

Objectives

The objectives of this study were to determine the sensitivity and specificity of mRDT and factors that affect these parameters using microscopy as the gold standard, to calculate the positive and negative predictive values of mRDT in the study population and to determine the association between parasite density and mRDT.

Hypothesis

We hypothesized that mRDT has sensitivity and specificity similar to microscopy.

Setting

The study was conducted in the Children Outpatient Clinic (CHOP) of the Federal Medical Centre, Asaba. The clinic has three consulting rooms that are run by family physicians (Residents and Consultants) in the Family Medicine department. An average of 100 malaria cases are seen monthly amongst under five children presenting to the clinic. Asaba is the capital city of Delta State and shares boundary with Anambra State on the eastern coast of the Niger River.

Rationale

Although some work has been carried out on this topic, there is paucity of published work on the subject in the South - South geopolitical zone of Nigeria, and the adoption of the mRDT is yet to be popular. This study is therefore aimed at bridging this gap and also to find out the parasite density at which the mRDT will become positive with the aim of making recommendations for its adoption during diagnosis of malaria, especially where the microscopic diagnosis is not feasible.

Research methods and design

Study design

The study was a cross-sectional study, comparing diagnostic accuracy of malaria using mRDT CareStatTM (a histidine-rich protein-2 Plasmodium falciparum-based kit) and microscopy conducted in the Children Outpatient Clinic (CHOP) of the Federal Medical Centre, Asaba. The kit was preferred as the falciparum species is the predominant species in the west African subregion. Ethical clearance was obtained from the ethical committee of the Federal Medical Centre Asaba (FMC/ASB/T/A81/66).

Participants were consecutively recruited into the study until the desired sample size was achieved. Finger prick blood sample was obtained, and one thin and one thick blood smears were prepared, stained with 10% Giemsa and read for the presence of malaria parasite by a microscopist. The microscopist was a qualified laboratory scientist with the Federal Medical Centre, Asaba. He has been doing malaria microscopy for 10 years and has been certified as a malaria microscopist. Ten out of the 98 slides were also randomly selected and sent to the parasitology unit of the Medical Microbiology Laboratory of the University College Hospital Ibadan. A drop of blood (about 5 µL) was also taken from the thumb by a dropper that came with the rapid diagnostic test kit. The malaria rapid tests were conducted by the second author, strictly following the instructions on the leaflet in the CareStartTM packs. The sample was introduced into the kit chamber and two drops of the buffer solution were introduced and left for 5-10 min. The results were read and recorded as positive or negative for malaria parasite. The microscopist was independent and hence not aware of the mRDT results obtained. This was performed to remove bias in his interpretation of the blood films sent to the laboratory. The results of the microscopy and the mRDT tests were compared using EPI InfoTM 7 (7.1.5) and the data were summarised using proportions, frequency and percentages. The sensitivity, specificity and predictive values of mRDT were compared with that of the microscopy. Regression analysis was used to determine the relationship between malaria parasite density and the positivity of mRDT.

Setting

The CHOP of the Federal Medical Centre, Asaba, Delta State, Nigeria, is being run by the Family Medicine Department, and it provides primary care delivery for children attending the hospital. The hospital is situated along Nnebisi road in the west-end area of the town close to Saint Patrick College, Asaba.

Study population

The study population were children who were under 5 years of age attending the Children Outpatient Clinic of the Federal Medical Centre, Asaba. The inclusion criteria were as follows: children whose parents or guardian provided informed consent, children aged between 3 and 59 months, children with axillary temperature ≥ 37.5 °C at presentation or a history of fever within the previous 48 h, children presenting with symptoms and signs comparable with the clinical picture of malaria. The exclusion criteria were as follows: refusal of the parents or guardians to provide informed consent, children with signs of severe illness or unconscious at presentation and those who were enrolled in other clinical studies.

Data collection

The data were collected using an interviewer-administered questionnaire in English and a translation into pidgin English for parents who did not understand English.

Data analysis

The data collected were analysed using the EPI Info Version 7 statistical package. Parasite density was assessed with the thick film, whilst parasite speciation was assessed with the thin film. The slide was considered negative when no parasite was seen or detected after screening 200 high power fields (see Table 1). Asexual stages of the malaria parasite on thick films were counted against about 200 White Blood Cells (WBCs).3

Ethical consideration

Ethical clearance to conduct the study was obtained from the Federal Medical Centre, Asaba, Nigeria (Ethical Clearance Number: FMC/ASB/T/A81/66) on 16 December 2015. The study was conducted in compliance with International Conference on Harmonisation - Good Clinical Practice (ICH GCP) and the Declaration of Helsinki.

Results

A total of 98 children aged between 3 and 59 months were recruited and enrolled in this study. There were 53 males and 45 females, giving a male-female ratio of 1:0.85. Most of the participants were in the age group of 3-24 months, accounting for 50 members (51.02%) of the total participants. The mean age ± standard deviation (s.d.) of the participants was 26.2 months ± 15.7 (range = 3-59 months) as shown in Table 2.

The most common clinical symptom was fever. Eighty-eight of the participants (89.8% [95% CI = 82.03% - 95.0%]) presented with fever. About 74.5% of the participants had raised temperature of ≥ 37.5 °C, with a mean ± s.d. temperature of 38.0 °C ± 0.9 °C (range = 36.0 °C - 39.9 °C) as shown in Table 3. Plasmodium falciparum was the only malaria species in this study, accounting for the entire positive malaria smear.

Both microscopy and mRDT were conducted on every participant. Fifty-two children (53.06% [95% CI = 40.72% - 61.26%]) out of 98 were found positive for the microscopy test, whilst 20 (20.41% [95% CI = 12.93% - 29.74%]) were positive with the mRDT test as shown in Figures 1 and 2.

Of the 20 participants who tested positive with the rapid diagnostic test, 19 gave a history of fever at the time of presentation. However, there was no significant relationship between fever and positivity of the rapid diagnostic test as shown in Table 4.

There was no significant relationship between the temperature at presentation and the malaria parasite count as shown in Table 5.

The linear regression plot of the relationship between the natural logarithm of the parasite density and the parasite count of the participants with malaria parasitaemia is shown in Figure 3. The log parasite density increased by a unit as the parasite count increased by 1.2 (r2p < 0.001). The geometric mean parasite density of P. falciparum was 32 319 asexual parasites/µL.

The percentage agreement of positive results of mRDT and parasite count using microscopy of +, ++, +++ and ++++ was 14.3%, 45.5%, 80% and 100%, respectively. The percentage agreement of negative results was 10.9%. The proportion is shown in Table 6.

The percentage agreement of positive results of mRDT and parasite count using microscopy is calculated as follows:

The sensitivity and specificity of the mRDT were 29% and 89%, respectively, whilst the positive and negative predictive values were 75% and 54%, respectively. The prevalence of malaria using microscopy in this study population was 53%. The false positive and false negative rates were 10.9% and 71.2%, respectively, as shown in Table 7:

Discussion

This study aimed at comparing the diagnostic accuracy of mRDT with microscopy amongst under five children so as to deploy mRDT for prompt diagnosis and treatment of malaria amongst children presenting to our hospital.

Malaria prevalence

The prevalence of malaria in this study using microscopy as a reference diagnostic test was 53% (95% CI = 46% - 60%). This value was lower than that recorded by Samadoulougou et al.45

Parasite species distribution

The species of malaria parasite identified in all study participants was P. falciparum. This agrees with a similar study carried out by Oyeyemi et al.5P. falciparum species of the malaria parasites was identified in all the study participants. However, Agomo et al.6P. falciparum was seen in 95.2% of the cases as either mixed infection with P. malariae (3.6%) or as a mono infection (91.6%). These results agree with literature findings that P. falciparum is responsible for more than 95% of malaria infections in the tropics.4,7,8

Distribution of parasite count

The result revealed that 52 children (53.1% [95% CI = 40.7% - 61.3%]) out of the 98 were positive for the microscopy test. Thirty seven (71.2%) out of the 52 children who were positive for the microscopy were found to be negative with mRDT (false negative). This gave a high false negative mRDT test when compared with the result of the microscopy in this study. This is very significant in this study, as this may have contributed to the low sensitivity reported. Sensitivity is the proportion of people with disease (malaria) who will have a positive result when tested with the diagnostic test kit (mRDT in this case) in the diagnosis of malaria.

The microscopy further showed that the parasite count of (+) made up 67% of the total population of patients with positive microscopy. Using this 'plus' system scale of scoring to calculate the parasite density, it therefore means that about 67% of the participants who had positive results with microscopy had a parasite density of between 10 and 90 parasites/µL of blood.9101011

Comparing the performance of malaria rapid diagnostic test and microscopy

Determination of sensitivity and specificity of malaria rapid diagnostic test

The sensitivity and specificity of the mRDT in this study were 29% and 89%, respectively. This means that the mRDT kit (CareStatTM) used in this study will be capable of detecting correctly (giving a positive result) only 29 out of 100 children with malaria infection and will give a negative result in 89 out of 100 patients without malaria infection. The very low sensitivity recorded in this study as against the WHO recommendations of about 95% may be because of a high false negative rate of 71.2% (37/52 × 100) of mRDT as compared to the microscopy. The high false negative rate is similar to the findings of Berhane et al. where only 10 out of the 50 microscopically confirmed P. falciparum infected specimens were confirmed positive (i.e. 40 mRDT negative results out of 50 confirmed specimens microscopically), with all the lots of mRDTs used in the study giving an 80% false negativity proportion.1210,13HRP-2 gene and the prozone effect (which is defined as false-negative or falsely low results in immunological reactions because of excess of either antigens or antibodies). This will eventually affect the sensitivity of the test.13,14,15

The low sensitivity of this study is in agreement with the research conducted by Oyeyemi et al. in Ijebu Ode, western part of Nigeria, who reported a sensitivity and specificity of 42.5% and 87.1%, respectively.5161718

It was also noted from this study that five (10.9%) of 46 children whose microscopy results were negative were positive with the rapid test (false positive). This may be as a result of persistent antigen of the malaria parasite in the blood even after parasite clearance following adequate anti-malaria treatment of the index cases. The persistent antigenaemia may have contributed to the high specificity recorded in this study. This agreed with the work of Batwala et al.19

The percentage agreement of positive results of mRDT and parasite count using microscopy was the highest (100%) at parasite count of (++++) and the lowest (14.3%) with parasite count of (+). Many of these (+) using microscopy were missed by the rapid test, thereby giving a low yield in the positivity of the mRDT and, consequently, the sensitivity of the malaria kit at this level of parasite count. This result agreed with the work of Sani et al. in Sokoto, Northern Nigeria, where it was found that the sensitivity of RDT increased consistently from 33% at low parasite density to 93% at high parasite density.2020,21,22722

The specificity of this study was comparable with most of other researches. However, the low sensitivity of this study agreed with the work carried out by Kahama-Maro et al. in Dar es Salaam, who found a low sensitivity. The low sensitivity in this study may not be completely explained only by the parasite density of the malaria as documented by researchers like Mawili-Mboumba.23

Positive and negative predictive values of malaria rapid diagnostic test

The positive and negative predictive values in this study were 75% and 53%, respectively. This result is slightly different from the findings of Falade et al.,7

The false positive and negative rates in this study were 10.9% and 71.2%, respectively. This false negative rate is quite high. Several factors may account for this high rate, which may include low parasite density. According to WHO, false-negative results can be caused by any or a combination of the following:

•the procurement and use of poor-quality RDTs

•use of the wrong comparator for the diagnostic test, such as poor-quality microscopy for cross-checking negative RDT

•poor transport and storage conditions for RDTs, with sustained exposure to high temperature

•operator errors during performance and/or interpretation of RDT results (more rarely)

•deletion or mutation of HRP-2 gene.

Association between parasite density and parasite count using microscopy

The linear regression plot (Figure 3) showed that the log parasite density increased by a unit value as the parasite count increased by 1.2 (p < 0.001). This relationship also indirectly affects the positivity of mRDT because the higher the parasite count, the greater the percentage agreement of positive results of mRDT with microscopy. It therefore means that the parasite density is directly related to the mRDT positivity.

Limitation

There was only one microscopist who regularly performed malaria microscopy for clinical care of patients in the study location where the volume of work could sometimes be high. There was no cross-checking of a predetermined percentage of the slides by a second microscopist.

Conclusion

The sensitivity and specificity of mRDT compared with microscopy diagnosis of malaria in this study were found to be 29% and 89%, respectively. There was a significant correlation between parasite count and parasite density (p < 0.001). We therefore advocate a more sensitive kit that can detect the malaria parasite at low density for future use, especially to improve the sensitivity of the mRDT kits in malaria management, where trained microscopists for malaria diagnosis are not available.

Competing interests

The authors have declared that no competing interests exist.

Authors' contributions

O.O. (Lincoln University College, Selangor, Malaysia) was responsible for the experimental and project design, protocol writing, data analysis, manuscript writing and review of the article. B.A.O. (The Ark Medical Centre, Asaba, Nigeria) performed the experiment and participated in the protocol writing and review of the manuscript. A.I.N. (Federal Medical Centre, Asaba, Nigeria) was involved in the writing of the protocol and review of the manuscript.

Funding information

The research received no specific grant from any funding agency in the public, commercial or not-for-profit sectors.

Data availability statement

Data sharing is not applicable to this article as no new data were created or analysed in this study.

Disclaimer

The views and opinions expressed in this article are those of the authors and do not necessarily reflect the official policy or position of any affiliated agency of the authors.

Acknowledgements

The authors thank Prof. Catherine O. Falade for her assistance and role at various stages of this research.

References

  • 1.Portero J-L, Rubio-Yuste M, Descalzo MA, et al. Accuracy of an immunochromatographic diagnostic test (ICT Malaria Combo Cassette Test) compared to microscopy among under five-year-old children when diagnosing malaria in Equatorial Guinea. Malar Res Treat. 2010;2010:858427. https://doi.org/10.4061/2010/858427
    » https://doi.org/10.4061/2010/858427
  • 2.Harriet Pasquale C, Jarvese M, Julla A, et al. Malaria control in South Sudan, 2006-2013: Strategies, progress and challenges. Malar J. 2013;12(1):2006-2013. https://doi.org/10.1186/1475-2875-12-374
    » https://doi.org/10.1186/1475-2875-12-374
  • 3.Aslan G, Seyrek A, Kocagoz T, Ulukanligil M, Erguven S, Gunalp A. The diagnosis of malaria and identification of plasmodium species by polymerase chain reaction in Turkey. Parasitol Int. 2007;56(3):217-220. https://doi.org/10.1016/j.parint.2007.03.001
    » https://doi.org/10.1016/j.parint.2007.03.001
  • 4.Samadoulougou S, Kirakoya-Samadoulougou F, Sarrassat S, et al. Paracheck® rapid diagnostic test for detecting malaria infection in under five children: A population-based survey in Burkina Faso. Malar J. 2014;13:101. https://doi.org/10.1186/1475-2875-13-101
    » https://doi.org/10.1186/1475-2875-13-101
  • 5.Oyeyemi OT, Ogunlade AF, Oyewole IO. Comparative assessment of microscopy and rapid diagnostic test (RDT) as malaria diagnostic tools. Res J Parasitol. 2015;10(3):120-126. https://doi.org/10.3923/jp.2015.120.126
    » https://doi.org/10.3923/jp.2015.120.126
  • 6.Agomo CO, Oyibo WA. Factors associated with risk of malaria infection among pregnant women in Lagos, Nigeria. Infect Dis Poverty. 2013;2(1):1. https://doi.org/10.1186/2049-9957-2-19
    » https://doi.org/10.1186/2049-9957-2-19
  • 7.Falade CO, Ajayi IO, Nsungwa-Sabiiti J, et al. Malaria rapid diagnostic tests and malaria microscopy for guiding malaria treatment of uncomplicated fevers in Nigeria and prereferral cases in 3 African countries. Clin Infect Dis. 2016;63(5):S290-S297. https://doi.org/10.1093/cid/ciw628
    » https://doi.org/10.1093/cid/ciw628
  • 8.World Health Organization. World Malaria Report 2014; Global Malaria Programme. WHO. Geneva. 2014; pp. 1-228.
  • 9.Kosack CS, Naing WT, Piriou E, Shanks L. Routine parallel diagnosis of malaria using microscopy and the malaria rapid diagnostic test SD 05FK60: The experience of Médecins Sans Frontières in Myanmar. Malar J. 2013;12(1):167. https://doi.org/10.1186/1475-2875-12-167
    » https://doi.org/10.1186/1475-2875-12-167
  • 10.Mouatcho JC, Goldring JPD. Malaria rapid diagnostic tests: Challenges and prospects. Clin Infect Dis. 2018;(2013):1491-1505. https://doi.org/10.1099/jmm.0.052506-0
    » https://doi.org/10.1099/jmm.0.052506-0
  • 11.Amadi EC, Ebenezer A, Daworiye PS. Comparison of rapid malaria test and laboratory microscopy investigation for community-based active surveillance of asymptomatic falciparum malaria in Yenagoa, Niger Delta, Nigeria. J Appl Sci Environ Manage. 2010;14(2):71-74. https://doi.org/10.4314/jasem.v14i2.57851
    » https://doi.org/10.4314/jasem.v14i2.57851
  • 12.Berhane A, Russom M, Bahta I, Hagos F, Ghirmai M, Uqubay S. Rapid diagnostic tests failing to detect Plasmodium falciparum infections in Eritrea: An investigation of reported false negative RDT results. Malar J. 2017;16(1):105. https://doi.org/10.1186/s12936-017-1752-9
    » https://doi.org/10.1186/s12936-017-1752-9
  • 13.Gillet P, Mori M, Van Esbroeck M, Van den Ende J, Jacobs J. Assessment of the prozone effect in malaria rapid diagnostic tests. Malar J. 2009;8:271. https://doi.org/10.1186/1475-2875-8-271
    » https://doi.org/10.1186/1475-2875-8-271
  • 14.Singh R, Abdullahi K, Bunza MDA, Singh S, Kaitholia K. Comparative diagnosis of falciparum malaria infections by microscopy, two RDTs, and nested PCR in the three states of North-western Nigeria. J Biol Agric Healthc. 2013;3(5):31-39.
  • 15.Koita OA, Doumbo OK, Ouattara A, et al. False-negative rapid diagnostic tests for malaria and deletion of the histidine-rich repeat region of the hrp2 gene. Am J Trop Med Hyg. 2012;86(2):194-198. https://doi.org/10.4269/ajtmh.2012.10-0665
    » https://doi.org/10.4269/ajtmh.2012.10-0665
  • 16.Garba BI, Muhammad AS, Musa A, et al. Diagnosis of malaria: A comparison between microscopy and rapid diagnostic test among under five children at Gusau, Nigeria. Sub-Saharan Afr J Med. 2016;3(2):96-101. https://doi.org/10.4103/2384-5147.184371
    » https://doi.org/10.4103/2384-5147.184371
  • 17.Ezeudu CE, Ebenebe JC, Ugochukwu EF, Chukwuka JO, Amilo GI, Okorie OI. The performance of an Histidine rich protein-2 rapid diagnostic test (RDT) against the standard microscopy in the diagnosis of malaria parasitaemia among febrile under five children at Nnewi. Niger J Paed. 2015;42(1):59-63. https://doi.org/10.4314/njp.v42i1.13
    » https://doi.org/10.4314/njp.v42i1.13
  • 18.Xiaodong S, Tambo E, Chun W, et al. Diagnostic performance of CareStartTM malaria HRP2/pLDH (Pf/pan) combo test versus standard microscopy on falciparum and vivax malaria between China-Myanmar endemic borders. Malar J. 2013;12(1):6. https://doi.org/10.1186/1475-2875-12-6
    » https://doi.org/10.1186/1475-2875-12-6
  • 19.Batwala V, Magnussen P, Nuwaha F. Are rapid diagnostic tests more accurate in diagnosis of plasmodium falciparum malaria compared to microscopy at rural health centres? Malar J. 2010;9(1):349. https://doi.org/10.1186/1475-2875-9-349
    » https://doi.org/10.1186/1475-2875-9-349
  • 20.Sani UM, Jiya NM, Ahmed H. Evaluation of a malaria rapid diagnostic test among febrile children in Sokoto, Nigeria. IJMMS. 2013;3(5):434-440.
  • 21.Harchut K, Standley C, Dobson A, Klaassen B, Rambaud-althaus C. Over-diagnosis of malaria by microscopy in the Kilombero Valley, Southern Tanzania : An evaluation of the utility and cost-effectiveness of rapid diagnostic tests. Malaria J. 2013;12:1-9. https://doi.org/10.1186/1475-2875-12-159
    » https://doi.org/10.1186/1475-2875-12-159
  • 22.Kahama-Maro J, Acremont VD, Mtasiwa D, Genton B, Lengeler C. Low quality of routine microscopy for malaria at different levels of the health system in Dar es Salaam. Malar J. 2011;10(1):332. https://doi.org/10.1186/1475-2875-10-332
    » https://doi.org/10.1186/1475-2875-10-332
  • 23.Mawili-Mboumba DP, Akotet MKB, Ngoungou EB, Kombila M. Evaluation of rapid diagnostic tests for malaria case management in Gabon. Diagn Microbiol Infect Dis. 2010;66(2):162-168. https://doi.org/10.1016/j.diagmicrobio.2009.09.011
    » https://doi.org/10.1016/j.diagmicrobio.2009.09.011

Correspondence:
Bamidele Ogunfowokan

Received: 26 Jul. 2019
Accepted: 09 Nov. 2019
Published: 17 June 2020

Publication Dates

  • Publication in this collection
    06 Jan 2022
  • Date of issue

History

  • Received
    26 July 2019
  • Accepted
    09 Nov 2019
location_on
AOSIS Publishing AOSIS Publishing, Postnet Suite #110, Private Bag X19, Durbanville, Cape Town, Western Cape Province, ZA, 7551, Tel: +27 21 975 2602, Tel: 086 1000 381 - E-mail: publishing@aosis.co.za
rss_feed Acompañe los números de esta revista en su lector de RSS
Ir para arriba