Open-access Corrosion resistance of laser-cladded 304L stainless steel enriched with ruthenium additions exposed to sulphuric acid and sodium chloride media

Abstract

The corrosion behaviour of 304L stainless steel laser-cladded with various amounts of ruthenium (Ru) was evaluated in solutions of sulphuric acid and sulphuric acid plus sodium chloride at 25°C and 45°C by open-circuit potential and cyclic potentiodynamic polarization tests. In general, the addition of Ru to the stainless steel increased its corrosion resistance in 1 M H2SO4, as well as in 1 M H2SO4 plus 1 wt% NaCl. This was observed for a number of parameters such as corrosion rate, corrosion potential, open-circuit potential, and current density. However, increasing the amount of Ru added beyond a certain level did not result in further improvement in corrosion protection. For each environment there is an optimal Ru concentration for the best corrosion protection. For example, in 1 M H2SO4 at 25°C, 2.44 wt% Ru shows the least active surface in terms of corrosion. Further research into ruthenium coatings on stainless steels is recommended.

corrosion protection; ruthenium; laser cladding; 304 stainless steel


location_on
The Southern African Institute of Mining and Metallurgy The Southern African Institute of Mining and Metallurgy, 5 Hollard Street, P.O. Box 61127, Marshalltown, Johannesburg, Gauteng, ZA, 2107, Tel: +27 11 834 1273, Tel: +27 11 834 1277 - E-mail: journal@saimm.co.za