Logomarca do periódico: Journal of the South African Institution of Civil Engineering

Open-access Journal of the South African Institution of Civil Engineering

Publicação de: South African Institution of Civil Engineering
Área: Engenharias
Versão impressa ISSN: 1021-2019
Creative Common - by 4.0

Sumário

Journal of the South African Institution of Civil Engineering, Volume: 65, Número: 3, Publicado: 2023

Journal of the South African Institution of Civil Engineering, Volume: 65, Número: 3, Publicado: 2023

Document list
Documents
Technical Paper
Revised Regional Maximum Flood (RMF) method and regionalisation du Plessis, J A Masule, S

Resumo em Inglês:

South Africa receives an average annual rainfall of about 450 mm. Hydraulic structures are typically constructed to either store or manage the excess water resulting from runoff. These hydraulic structures are designed and evaluated to withstand a particular flood peak that can occur in its catchment area. Adequate flow or rainfall records may often not be available to enable a reliable flood estimation. In South Africa an empirical estimation method (the Regional Maximum Flood (RMF)) that utilises regional envelope curves to estimate the maximum observed flood peaks that can be expected in a region, is available. The RMF method adopted by Kovács in 1980, and revised in 1988, is robust and simple to use. The current research revisits the method as applicable to South Africa, and presents an update of the method, taking more than 30 years of additional data and a revised regionalisation approach into consideration. Numerous previous researchers evaluated the RMF method and concluded that the method needs to be updated. It was identified that recently observed flood peaks exceeded the existing RMF envelopes. It was further identified that the Kovács regionalisation process is inconsistent, and a revised regionalisation approach was proposed. The revised regionalisation resulted in 15 RMF K regions and their associated envelope curves. The new RMF K regions are smaller, with the highest K value equal to 5.8 and the lowest value 2.8. The recommended envelope curves were drawn 15% above the maximum observed flood peaks for each region, allowing for possible future climate impacts. The revised RMF envelope curves are considered to adequately represent the RMFs in South Africa and are therefore applicable for determining the expected maximum regional flood at any site in South Africa.
Technical Paper
The status of water for firefighting in South Africa Ilemobade, A

Resumo em Inglês:

It is mandatory in South Africa that water for firefighting is included in the demand estimates input when designing municipal water networks. To this end, guidelines for determining fire flows for different risk categories have been developed. The most commonly used guidelines are the South African National Standard (SANS) 10090 of 2018 and the Department of Human Settlements (DHS) guide of 2019 (also called the Red Book). The evolution of the built environment, firefighting technologies and approaches, and the availability of freshwater resources all require that the fire flows in the guidelines are current and adequately protect communities from the devastating impacts of fires - this while conserving depleting freshwater resources and contributing to optimal water network design. Currently, empirical research into the appropriateness of the fire flows in SANS 10090 and the Red Book to firefighting efforts in South African municipalities is limited. This paper therefore compares water for firefighting in these two guidelines with some international companions and local firefighting data, and also compares similar data from the six studies published on this topic in South Africa. Some highlights from this investigation include: (i) the fire risk categories and fire flows in SANS 10090 and the Red Book are misaligned, and are contradictory in at least one instance; (ii) when compared with firefighting data, the fire flows in SANS 10090 and the Red Book are conservative; (iii) a significant percentage of fires were extinguished between 30 and 120 minutes; (iv) 10 kl or less of water was employed to extinguish more than 87% of fires; and (v) the frequencies of fires were positively related to dry and/or cold weather conditions.
Technical Paper
Experimental comparison of active seismic surface wave tests on shallow and deep bedrock sites Ntaote, M C Heymann, G

Resumo em Inglês:

Active seismic surface wave tests are tests during which signals are generated by artificial sources such as sledgehammers, drop weights and fixed or variable frequency shakers. A number of active seismic surface wave tests have become popular in the geotechnical industry. Interestingly, different surface wave tests are popular in different regions of the world, presumably because the tests require different equipment, expertise and numerical analysis techniques. Few studies have been done to compare seismic surface wave tests directly. This study investigated the performance of three active seismic surface wave tests, namely the spectral analysis of surface waves (SASW), multi-channel analysis of surface waves (MASW) and continuous surface wave (CSW) tests. This paper reports the performance of the three tests with regard to repeatability, susceptibility to near-field effects, and maximum and minimum measurement depths at both a shallow and a deep bedrock site.
Technical Paper
Thermal performance of cavities in 3DPC building façades Moelich, M van Zijl, G de Villiers, W

Resumo em Inglês:

In the quest for sufficient and comfortable housing in South Africa, attention to building orientation and thermal transmittance principles has significantly improved thermal performance in local houses. Thermal simulation and monitoring of houses in the Joe Slovo Phase Three development in Cape Town confirms improved performance by solar radiation blockage and shading. This paper simulates the thermal performance of a housing unit in this development. The house was instrumented with thermocouples, and monitored from March to December 2013 by Sustainable Energy Africa in collaboration with the National Department of Human Settlements. Sustainable Energy Africa reported significant improvement when compared to a nearby traditional Reconstruction and Development Programme house that had been monitored during the same period. With the benefit of the monitored thermal data, complete drawings, and specification details of the Joe Slovo Phase Three unit, the current research modelled and calibrated a simulation model in DesignBuilder. DesignBuilder was selected given its accreditation status for Green Star Rating of buildings in South Africa. An additional motivation for investigating this unit was the availability of recorded weather data from the nearby Cape Town International Airport, captured in the DesignBuilder climate data base for 2013, which was assumed relevant in lieu of complete weather station data measured at the location of the housing unit. The study aimed to simulate the monitored temperatures in the house with acceptable agreement, and to investigate further potential improvement in occupant thermal comfort by alternative 3D-printed concrete walling developed by the authors. Systematic finite element analysis (FEA) iteratively solved cavity radiation and convection in wall cavities to calibrate thermal transmittance parameters for DesignBuilder. The FEA results acceptably simulated temperatures monitored in this physical wall experiment. The calibrated DesignBuilder model simulated the indoor temperatures of the monitored house with acceptable agreement, and predicted significant improvement in occupant thermal comfort if the walls were 3D-printed with a particular cross-sectional design.
location_on
South African Institution of Civil Engineering South African Institution of Civil Engineering, Private Bag X200, Halfway House, Midrand, Johannesburg, Gauteng, ZA, 1685, Tel: +27 11 805 5947 - E-mail: verelene@saice.org.za
rss_feed Acompanhe os números deste periódico no seu leitor de RSS
Ir para o topo