Open-access Influence of coal properties on the performance of fixed-bed coal-burning braziers

Abstract

Informal fixed-bed coal-burning braziers are used extensively in low-income communities of South Africa for space-heating and cooking needs. An investigation was carried out on the effects of coal moisture content and coal quality on the thermal and emissions performance of domestic coal-burning braziers in three field-procured braziers (with three different air ventilation rates), using the bottom-lit updraft (BLUD) and top-lit updraft (TLUD) ignition methods. Results showed that an increase in coal moisture content (from 2.4 wt.% to 8.6 wt.%) led to 18% and 30% decreases in fire-power when using the TLUD and BLUD methods, respectively. The combustion efficiency increased by 25% with an increase in moisture content. Measured carbon monoxide (CO) emission factors increased with an increase in moisture content, while carbon dioxide (CO2) emission factors remained unchanged. The use of A-grade coal resulted in a 49% increase in PM emissions compared with D-grade coal at high ventilation rates, despite no statistically significant differences (p > 0.05) in CO and CO2 emission factors produced between coal grades.

combustion efficiency; emission factors; ignition methods; imbaula; moisture content


location_on
The Department of Chemical Engineering of the University of Cape Town Department of Chemical Engineering, University of Cape Town, Private Bag X3, Rondebosch, Cape Town, Western Cape Province, ZA, 7701, Tel: +27 21 650 3892 - E-mail: journalofenergysouthernafrica@gmail.com
rss_feed Stay informed of issues for this journal through your RSS reader
Go to top