Logomarca do periódico: Clean Air Journal

Open-access Clean Air Journal

Publication of: National Association for Clean Air
Area: Engenharias, Ciências Biológicas
ISSN printed version: 1017-1703
Creative Common - by 4.0

Table of contents

Clean Air Journal, Volume: 31, Issue: 2, Published: 2021

Clean Air Journal, Volume: 31, Issue: 2, Published: 2021

Document list
Documents
News
Clean Air Journal celebrated this year's International Day of Clean Air for Blue Skies Wernecke, Bianca
Research brief
Estimating lightning NOx production over South Africa Maseko, Bathobile Feig, Gregor Burger, Roelof
In Memoriam
Remembering the late Benton Pillay
Research Article
Modeling tropospheric ozone and particulate matter in Tunis, Tunisia using generalized additive model Hammouda, Zouhour Zaier, Leila Hedhili Blond, Nadège

Abstract in English:

The main purpose of this paper is to analyze the sensitivity of tropospheric ozone and particulate matter concentrations to changes in local scale meteorology with the aid of meteorological variables (wind speed, wind direction, relative humidity, solar radiation and temperature) and intensity of traffic using hourly concentration of NOX, which are measured in three different locations in Tunis, (i.e. Gazela, Mannouba and Bab Aliwa). In order to quantify the impact of meteorological conditions and precursor concentrations on air pollution, a general model was developed where the logarithm of the hourly concentrations of O3 and PM10 were modeled as a sum of non-linear functions using the framework of Generalized Additive Models (GAMs). Partial effects of each predictor are presented. We obtain a good fit with R2 = 85% for the response variable O3 at Bab Aliwa station. Results show the aggregate impact of meteorological variables in the models explained 29% of the variance in PM10 and 41% in O3. This indicates that local meteorological condition is an active driver of air quality in Tunis. The time variables (hour of the day, day of the week and month) also have an effect. This is especially true for the time variable "month" that contributes significantly to the description of the study area.
Special Issue: Air Quality On The South African Highveld
The quality of the first and second Vaal Triangle Airshed Priority Area Air Quality Management Plans Moreoane, Lehlogonolo Mukwevho, Phathutshedzo Burger, Roelof

Abstract in English:

In response to deteriorating air quality, South Africa implemented national programmes that aim to manage and regulate ambient air quality and air pollution. Air Quality Management Plans (AQMPs) are clear outlines of measures and resources needed to achieve air quality objectives in a given geographical area and require support from government, business, industry, non-governmental organisations (NGOs) and the public. The success of the AQMPs depends primarily on the support of all stakeholders and the quality of the management plan. The Vaal Triangle Airshed Priority Area (VTAPA) was declared in 2006 as an area where ambient air quality standards are exceeded or may cause adverse air quality impacts. This research study focused on the VTAPA to evaluate the quality of the first and second-generation AQMPs for the VTAPA. Quality evaluation includes an analysis of procedures, processes, methods and documents. Effectiveness refers to the results of individual activities; therefore, the extent to which the AQMP met the expected outcomes of the review package defined the quality of the AQMP report. Both the first and draft second-generation AQMPs were considered to be of good quality. The first-generation AQMP was found to be of better quality than that of the draft second-generation AQMP. Funding mechanisms need to be investigated to assist in implementing intervention strategies in the AQMP as both the first and draft second-generation AQMPs were found to lack the potential to secure funds. Though the draft second-generation AQMP was found to be of lesser quality, the source apportionment study for identification of all sources as well as a better-outlined air quality management system was found to be good improvements to the AQMP.
Special Issue: Air Quality On The South African Highveld
Does apparent temperature modify the effects of air pollution on respiratory disease hospital admissions in an industrial area of South Africa? Olutola, Bukola G Wichmann, Janine

Abstract in English:

BACKGROUND: Temperature and air pollution are often treated as separate risk factors and very few studies investigated effect modification by temperature on air pollution, and the impact of this interaction on human health in Africa. This study therefore investigated the modifying effects of temperature on the association between air pollution and respiratory disease (RD) hospital admissions in South Africa. METHODS: RD admission data (ICD10 J00-J99) were obtained from two hospitals located in Secunda, South Africa beween 1 January 2011 to 31 October 2016. Ambient NO2, SO2, PM, PM25, temperature and relative humidity data were obtained from the South African Weather Services. A case-crossover epidemiological study design was applied and lag0-1 was used. Models were adjusted for public holidays and apparent temperature (Tapp). Days were classified as warm (Tapp>75th percentile), cold (Tapp<25th percentile) and normal (Tapp 25th-75th percentile. RESULTS: Of the 14 568 RD admissions, approximately an equal number of females and males were admitted. The average daily NO2, SO2, PM25 and PM10 levels were 12.4 μg/m3, 8.5 μg/m3, 32.3 μg/m3 and 68.6 μg/m3, respectively. Overall, a 10 μg/m3 increase in SO2 on warm days was associated with an increase in RD hospital admissions: 8.5% (95% Conf. Int: 0.4%, 17.2%) and 8.4% (95% Conf. Int: 0.3%, 17.1%) after adjustment for PM25 and PM, respectively. However, increasing PM25 or PM10 levels was associated with an increase in RD hospital admissions on normal days,after adjusting for SO2. On cold days there were significant associations between the SO2 and RD admissions among the 0-14 year age group, after adjusting for either PM25 (6.5%; 95% Conf.Int: 0.9%, 12.4%) or PM10 (5.5%; 95% Conf.Int: 0.3%, 11.1%. CONCLUSIONS: These results indicate that the risk of RD hospital admission due to ambient air pollution exposure is different on cold, normal and warm days in Secunda.
Special Issue: Air Quality On The South African Highveld
Source apportionment of ambient fine and coarse aerosols in Embalenhle and Kinross, South Africa Walton, Nicola M. Piketh, Stuart J. Zyl, Pietervan Maenhaut, Willy Burger, Roelof Language, Brigitte Formenti, Paola

Abstract in English:

The South African Highveld is recognised as a region having significant negative ambient air quality impacts with its declaration as an Air Quality Priority Area in 2007. Such areas require the implementation of specific air quality intervention strategies to address the air quality situation. A greater understanding of the composition of the atmospheric aerosol loading and the contributing air pollution sources will assist with the formulation and implementation of these strategies. This study aims to assess the composition and sources of the aerosol loading in Embalenhle and Kinross located on the Highveld. Fine (PM2.5) and coarse (PM.25-10) aerosol samples were collected during summer and winter, which were quantified by gravimetry. Wavelength-Dispersive X-Ray Fluorescence (WD-XRF) spectrometry and Ion Chromatography (IC) analysis were applied to determine the chemical compositions of aerosol samples on filters. Mean PM2.5 concentrations in Embalenhle and Kinross ranged from 16.3 to 34.1 ug/m3 during winter and 7.4 to 19.0 ug/m3 during summer. Mean PM2.5-10 concentrations ranged from 10.3 to 114 ug/m3 during winter and 5.9 to 11.2 μg/m3 during summer. Si, Al, S, SO42- and NH4+ were the most abundant species in PM2.5 during both seasons. The elements Na and Ca were also abundant at both sites during winter and summer, respectively. In PM2.5-10, Si, Al, SO42- and F- were the most abundant species during both seasons. The element Na was also abundant at both sites during winter with S and Ca also having high abundances at Embalenhle and Kinross, respectively, during summer. Source apportionment was performed by Positive Matrix Factorisation (PMF), which resolved five sources. Dust, secondary aerosols, residential combustion, wood and biomass burning, and industry were determined to be the contributing sources. Any measures to mitigate particulate air pollution on the Highveld should consider these key sources.
Editorial
The new WHO Global Air Quality Guidelines: What do they mean for South Africa? Garland, Rebecca M Wernecke, Bianca Feig, Gregor Langerman, Kristy
Editorial
Introduction to the special issue: Air quality on the South African Highveld Masekoameng, Elizabeth Kornelius, Gerrit O'Beirne, Sean
News
NACA conference 2021 - Evidence-based pathways to clean air in South Africa Mkhatshwa, Gabi Burger, Roelof Lange, Anzel De
Special Issue: Air Quality On The South African Highveld
Quantifying potential particulate matter intake dose in a low-income community in South Africa Wernecke, Bianca Burger, Roelof P. Language, Brigitte Wright, Caradee Y. Piketh, Stuart J.

Abstract in English:

Understanding how exposure to particulate matter impacts human health is complex. Personal exposure is a function of the pollution concentrations measured at any given place and time. The health impacts of this exposure are, in part, determined by how high pollutant concentrations are and how much pollution can potentially enter the body. This study considered data gathered in the winter of 2013 in a low-income community on the Mpumalanga Highveld, South Africa, which is a geographical area known for its high air pollution levels. Data collected by GPS monitors worn by individuals in the community were used to understand in which microenvironments people spend most of their time. Participants spent time in five main micro-environments: (highest rank first) inside a house, directly outside a house, on a dirt road, on a tar road, and on an open field. Eight days' worth of ambient, indoor and personal particulate matter measurements were paired with individual GPS positioning data for one study participant. We identified pollutant concentrations where the person spent time and how much particulate matter the person potentially inhaled. Highest concentrations were measured inside the dwelling and directly outside the dwelling of the individual. When comparing directly (ranging from 0.02 -0.76 mg) - and indirectly (0.02 - 0.34 mg) derived time-weighted potential intake doses, directly derived intake doses were higher and more likely to represent how much particulate matter was potentially inhaled by the participant. This study suggests that people living in communities on the Mpumalanga Highveld are exposed to unacceptably high air pollution levels in places in which they spend most of their time. Direct exposure and intake dose assessments are an important element of environmental health studies to supplement data collected by stationary monitors in order to better understand exactly what people are breathing.
location_on
National Association for Clean Air 17 Riverview, Brakfontein Road, The Reeds, Centurion, Pretoria, Gauteng, ZA, 0001, Tel: +27 12 339 8543 - E-mail: cleanairjournal@gmail.com
rss_feed Stay informed of issues for this journal through your RSS reader
Go to top