Sumário
Clean Air Journal, Volume: 29, Número: 1, Publicado: 2019Clean Air Journal, Volume: 29, Número: 1, Publicado: 2019
| Documents |
|---|
|
Editorial Celebration of the 80th Issue Feig, Gregor Garland, Rebecca Langerman, Kristy Wright, Caradee Y. Kornelius, Gerrit |
|
Message Message from the NACA President Piketh, Stuart |
|
News First WHO Global Conference on Air Pollution and Health: A Brief Report Gatari, Michael J. |
|
News Marine atmospheric chemistry research on the South African ice-breaker, the R/V SA Agulhas II Altieri, Katye Smith, Shantelle |
|
News Sixth Global Environmental Outlook report calls for scaling up environmental protection Wright, Caradee Y. |
|
Book review Gary Lackmann's book Midlatitude Synoptic Meteorology: Dynamics, Analysis and Forecasting and Synoptic-Dynamic Meteorology Lab Manual, by Gary M. Lackmann, Brian E. Mapes and Kevin R. Tyle Landman, Willem |
|
Research briefs South African Highveld concentrations of outdoor Total Gaseous Mercury Belelie, MD Piketh, SJ Burger, RP Naidoo, M |
|
Research briefs Indoor Particulate Matter Concentration Variations and Associations with Indoor/Outdoor Temperature in Rural Limpopo Kapwata, Thandi Language, Brigitte Piketh, Stuart Wright, Caradee Y. |
|
Research briefs Summary of research paper published in Journal of Atmospheric Chemistry titled: Assessment of polar organic aerosols at a regional background site in southern Africa Booyens, Wanda Beukes, Johan P. Van Zyl, Pieter G. Ruiz-Jimenez, Jose Kopperi, Matias Riekkola, Marja-Liisa Josipovic, Miroslav Vakkari, Ville Laakso, Lauri |
|
Research articles The potential for domestic thermal insulation retrofits on the South African Highveld Matandirotya, Newton R Cilliers, Dirk P Burger, Roelof P Language, Brigitte Pauw, Christian Piketh, Stuart J Resumo em Inglês: The South African Highveld is a portion on the inland plateau characterized by low winter ambient temperatures. Studies done in several climatic regions around the world have found a positive relationship between inadequate housing and low indoor temperatures during the winter season. Prolonged exposure to low indoor temperature is a threat to human physical health. This study characterizes indoor human thermal comfort conditions in typical low-income residential dwellings during the winter season. Mapping indoor human thermal comfort can assist in exploring the potential for domestic thermal insulation retrofits interventions. In-situ temperature measurements were done in 2014, 2016 and 2017 across three Highveld settlements of kwaZamokuhle, kwaDela, and Jouberton. The sample included a mixture of old (pre-1994), post 1994 Reconstruction and Development Programme (RDP) as well as non-RDP structures. Findings were that 88% of sampled dwellings in Jouberton 2016, 86% in Jouberton 2017, 62% in kwaDela and 58% in kwaZamokuhle had daily mean temperatures below the WHO guideline of 18°C. These low indoor temperatures indicate poor insulation in these sampled dwellings. Across all settlements, insulated dwellings had higher daily mean indoor temperatures than non-insulated dwellings. These findings indicate the potential to use thermal insulation retrofits in improving indoor thermal conditions as the majority of dwellings are non-insulated thereby exposing occupants to low indoor temperatures. |
|
Research articles Assessing the impact of Eskom power plant emissions on ambient air quality over KwaZamokuhle Belelie, Monray D Burger, Roelof Ρ Mkhatshwa, Gabi Piketh, Stuart J Resumo em Inglês: Coal-fired power plants are considered a major source of criteria air pollutants. The existence of such activities close to densely populated areas has an impact on human health and more generally on the environment. The impact of a pollutant typically depends on its residence time and the existence of background concentration levels. This study evaluates the dispersion of PM25, SO2 and NOX emissions from Eskom power plants (Arnot, Hendrina, and Komati) located close to KwaZamokuhle Township. AERMOD was used to assess the contribution of each plant to the air quality of the township. This steady-state dispersion model was used to simulate surface concentrations (1-hour, 24-hour and annual average concentrations) on a 50km domain for 2015-2017. The modelled results together with data obtained from Eskom's KwaZamokuhle monitoring site were used to estimate the extent to which these power plants contribute to the ambient air quality of KwaZamokuhle Township. The results confirm that the power plants do contribute to concentrations of PM25, SO2, and NOx in the ambient air of the township. However, based on a comparison between the modelled and monitored data, it was inferred that power plants are not the only significant source of these criteria pollutants. Evidence from temporal variations in the monitored data shows that domestic burning is likely the major contributor since the variability is more closely associated with burning habits. It is therefore likely that existing regulatory strategies that focus mostly on the industrial sector may not be successful in improving ambient air quality in low-income settlements like KwaZamokuhle. |
Leia a Declaração de Acesso Aberto
