Logomarca do periódico: Clean Air Journal

Open-access Clean Air Journal

Publication of: National Association for Clean Air
Area: Engenharias, Ciências Biológicas
ISSN printed version: 1017-1703
Creative Common - by 4.0

Table of contents

Clean Air Journal, Volume: 28, Issue: 1, Published: 2018

Clean Air Journal, Volume: 28, Issue: 1, Published: 2018

Document list
Documents
Editorials
South African Air Quality Information System (SAAQIS) mobile application tool: bringing real time state of air quality to South Africans Gwaze, Patience Mashele, Sindisiwe H.
Editorials
News on air pollution and health data and impacts on health from the World Health Organization Gumy, Sophie Mudu, Pierpaolo
Commentary
Continuous air monitoring results laid bare: do we know what we know? Forbes, Patricia
Research briefs
Estimates of CO2 fluxes for Cape Town Nickless, Alecia
Research briefs
Leaf uptake of mercury lowers global air pollution. Cape Point GAW Station's research published in Nature Geoscience Journal Labuschagne, Casper
In Memoriam
Professor George Djolov
In Memoriam
Johan van Heerden
Research articles
The economics of flue gas cooling technology for coal-fired power stations with flue gas desulfurisation Roberts*, Pierru Luther Els, C. J. Bosyi, Oleg Kornelius, Gerrit

Abstract in English:

Developments in heat exchanger technology, specifically in the use of polymers as tube material, have allowed the use of gas to water heat exchangers under conditions previously not viable. Two applications in the flue gas cleaning circuit of coal-fired power stations are described in this paper. In conventional pulverised coal-fired boilers, cooling of gas prior to the wet flue gas desulfurisation (WFGD) absorber reduces water consumption for evaporative cooling of the flue gas and can recover heat for feed water preheating or for use elsewhere in the plant. In another application, circulating fluidised bed boilers, which are currently proposed for a few independent power producers and may not require wet FGD, heat recovery is still feasible upstream of the bag filter typically used for particulate emission control. The extracted heat can again be recovered for use in other power plant processes, in this case most economically for pre-heating combustion air. This paper presents case studies for each of the above applications, showing that the power station efficiency is typically increased by approximately 1% of its pre-installation value. An economic analysis is provided for each, including additional power sales, reduced water consumption, or reduced fuel use with a reduction in carbon tax. For the larger installations with WFGD, payback time can be in the order of 6 years.
Research articles
An economic assessment of SO2 reduction from industrial sources on the highveld of South Africa Steyn, Marilize Kornelius, Gerrit

Abstract in English:

The costs and benefits associated with the implementation of an SO2 point source standard for solid fuel combustion installations (Category 1.1 sources, National Environmental Management: Air Quality Act: s21 List of Activities 2013) were evaluated to assess the desirability of implementation of the standards from an environmental as well as economic point of view. The study used a bottoms-up or impact pathway approach to analyse the impact of emission reduction. To reach the new plant (2020) SO2 emission standard of 500 mg/Nm3, the installation of wet flue gas desulfurisation (FGD) is the likely technology as it is a widely installed and well-developed technology. Costs and benefits associated with the installation of FGD were identified and ranked into four categories, based on the expected impact and the availability of information. All costs and benefits that could be quantified and monetized (Category 1 impacts) were included in the evaluation. A sensitivity analysis was conducted on the costs and benefits with the largest impact on NPV (net present value) or the largest uncertainty associated with the calculation to determine a range of feasible values. Site specific information was used where available, supplemented by benefit transfer where local data was not available. The impact on premature adult mortality was found to be the most significant benefit and dependent on the concentration response function selected and sensitive to the VSL (value of statistical life) estimate used (high R115 billion; low R36 billion). The choice of appropriate concentration response functions and the applicability thereof in the South African context are important considerations, likely requiring further study. The capital cost of FGD installations was found to be the most significant cost and was sensitive to the evaluation method (central R187 bil; high R306 bil; low R80 bil). Failure to account for operating costs would significantly impact the economic evaluation. The results of the study indicate that, given the information currently available, it is unlikely that the benefit of reducing SO2 emissions from existing sources to the required standard outweighs the cost of implementation on the Mpumalanga Highveld.
Research articles
Fine PM emission factors from residential burning of solid fuels using traditional cast-iron coal stoves Nkosi, Ncobile C Piketh, Stuart J Burger, Roelof P

Abstract in English:

Residential burning of solid fuels is a major source of fine particulate matter (PM25), which degrades indoor and ambient air quality in low-income settlements. The adverse impact of fine particulate emissions on the environment and human health is well-documented in other countries such as China and India; however, there is need for local studies to report on emission factors from residential burning of solid fuels. An emission factor quantifies the total mass of a pollutant emitted per amount of fuel burned. Emission factor is an input parameter in air quality modelling to forecast a pollutant concentrations over time and when calculating total emissions from a specific source. Local emission factors are central to managing air quality for they give results that are representative of the source compared with international emission factors. Quantifying emissions, understanding household fuel use patterns and interaction with the stove (stove operation behaviour) during a burning event is fundamental when designing emission control strategies. The aim of the study is to quantify fine particulate matter emissions from residential coal burning using systematic field measurements. The objectives of the study are (i) to characterize stove operation behavior effect on the emissions and (ii) to quantify PM25 emission factors using field measurements. Isokinetic (2015) and direct (2014) stack sampling tests were done to observe how PM emissions profiles change with stove operation behavior and to quantify PM25 emitted per kilogram of fuel burned. Fine PM emission profiles change with stove operation behavior with an emission factor ranging 6.8 g.kg-1 and 13.5 g.kg-1. The study results implies that residential coal burning is a major source of fine particulate matter in the residential area. As demonstrated that stove operation behaviour affect stove to fuel combination emissions; it is therefore suggested that those factors leading to increase emissions should be kept minimum.
Research articles
Household air pollution exposure and respiratory health outcomes: a narrative review update of the South African epidemiological evidence Shezi, Busisiwe Wright, Caradee Y

Abstract in English:

One of the greatest threats to public health is personal exposure to air pollution from indoor sources. The impact of air pollution on mortality and morbidity globally and in South Africa is large and places a burden on healthcare systems for treatment and care of air pollution-related diseases. Household air pollution (HAP) exposure attributed to the burning of solid fuels for cooking and heating is associated with several adverse health impacts including impacts on the respiratory system. The researchers sought to update the South African evidence on HAP exposure and respiratory health outcomes from 2005. Our quasi-systematic review produced 27 eligible studies, however, only four of these studies considered measures of both HAP exposure and respiratory health outcomes. While all of the studies that were reviewed show evidence of the serious problem of HAP and possible association with negative health outcomes in South Africa, no studies provided critically important information for South Africa, namely, local estimates of relative risks that may be applied in burden of disease studies and concentration response functions for criteria pollutants. Almost all of the studies that were reviewed were cross-sectional, observational studies. To strengthen the evidence of HAP exposure-health outcome impacts on respiratory health, researchers need to pursue studies such as cohort, time-series and randomised intervention trials, among other study designs. South African and other researchers working in this field need to work together and take a leap towards a new era of epidemiological research that uses more sophisticated methods and analyses to provide the best possible evidence. This evidence may then be used with greater confidence to motivate for policy-making, contribute to international processes such as for guideline development, and ultimately strengthen the evidence for design of interventions that will reduce HAP and the burden of disease associated with exposure to HAP in South Africa.
location_on
National Association for Clean Air 17 Riverview, Brakfontein Road, The Reeds, Centurion, Pretoria, Gauteng, ZA, 0001, Tel: +27 12 339 8543 - E-mail: cleanairjournal@gmail.com
rss_feed Stay informed of issues for this journal through your RSS reader