Open-access Normative values for retinal parameters in a Ghanaian clinical population at risk for glaucoma

Abstract

BACKGROUND: There is rarity of normative data on retinal parameters associated with glaucoma in Ghanaians. AIM: This study aimed to provide normative data on retinal parameters associated with glaucoma in an at-risk Ghanaian clinical population. SETTING: The study was conducted at the Eye Clinic of the Komfo Anokye Teaching Hospital, Ghana. METHODS: Ophthalmic data were obtained from 338 eyes of 116 males and 222 females (mean age: 61.86 ± 9.54 years, range: 45-89 years). The participants underwent eye examinations including visual acuity measurement using the Snellen chart at 6 m, auto-refraction using the Retinomax K+ Screen Hand-Held Autorefractor Keratometer, Goldmann applanation tonometry, slit-lamp biomicroscopy, fundus examination using a 90D Volks lens, and optical coherence tomography (OCT) using the Zeiss Cirrus HD OCT (Carl Zeiss Meditec, Dublin, CA, United States). Height and weight of participants were measured using a measuring tape and a weighing scale, respectively. RESULTS: Mean ± standard deviation values for retinal parameters were: global peripapillary retinal nerve fibre layer (ppRNFL) = 96.11 ± 9.87 µm, global macula ganglion cell complex (mGCC) = 80.91 ± 5.61 µm, optic disc area = 2.05 ± 0.39 mm2, rim area = 1.52 ± 0.27 mm2, cup volume = 0.13 ± 0.12 mm3, average cup to disc ratio (ACDR) = 0.47 ± 0.15 and vertical cup to disc ratio (VCDR) = 0.44 ± 0.14. CONCLUSION: Thicker ppRNFL and mGCC may delay diagnosis of pre-perimetric glaucoma in Ghanaians, while larger ACDR and VCDR measurements may lead to glaucoma misdiagnosis. CONTRIBUTION: This study established normative values for retinal parameters associated with glaucoma in Ghanaians.

glaucoma; Africans; normative database; Ghana; retina; optic nerve


Introduction

Glaucoma, the leading cause of irrevocable blindness globally, is an optic neuropathy characterised by progressive degeneration of the optic nerve with associated visual field loss.123,4,5

Previous reports show that Ghana has a high prevalence of glaucoma as well as a severe form of the disease and a high risk of glaucoma-related blindness.6,789,10

Retinal parameters such as peripapillary retinal nerve fibre layer (ppRNFL), macula ganglion cell complex (mGCC) and optic nerve head (ONH) and its associated parameters play a vital role in the detection and management of glaucoma. Studies report that retinal parameter measurements are vastly influenced by ethnicity.11,12,13,14151616

In addition, the ethnic variation in mGCC thickness was confirmed by Tham et al.141718,19,20,21

The optical coherence tomography (OCT) machine has, in recent times, become the instrument of choice in clinical and research settings because of its ability to provide objective, precise, quantifiable and reproducible measurements of retinal parameters. Despite these existing ethnic variations in retinal parameter measurements, there is an under-representation of some ethnic groups particularly, African populations in normative databases used in OCT machines. This may pose a challenge in the accurate interpretation of OCT reports in individuals from such ethnic groups.16,222123242526

In view of the ethnic variations in normative reference values for retinal parameters and the under-representation of some ethnic groups in the normative databases employed by OCT machines, it implies that the decision on the integrity of retinal parameters in Ghanaians is interpreted against a backdrop of normative reference values derived from different ethnic groups, which may lead to a misdiagnosis as a result of an overestimation or underestimation. Hence, there is the need for the documentation of normative reference values for retinal parameters specific to the Ghanaian population.

Despite the reported high prevalence of glaucoma in Ghana, there is a paucity of published normative data on retinal parameters associated with glaucoma in this population. Therefore, the aim of this study is to provide normative data on retinal parameters associated with glaucoma in a Ghanaian clinical population of older age, which places them at increased risk. Normative reference values for retinal parameters specific to the Ghanaian population will serve as a reference point for future development of OCT machines and allow for early detection of retinal tissue loss, which will make room for early diagnosis and management of pre-perimetric glaucoma. It will also enable clinicians to easily identify individuals at risk for some retinal pathologies such as glaucoma and monitor them closely as well as contribute to the future modelling of glaucoma care offered to Ghanaians and other vulnerable African populations.

Research methods and design

The study was part of a larger Genetics In Glaucoma Patients of African descent (GIGA) Study. The GIGA study was a multinational collaborative case-control study comprising open-angle glaucoma patients and healthy subjects from Ghana, Tanzania and South Africa. However, data for this study were collected from Ghanaian participants only. The Ghanaian version of the GIGA study was conducted in a clinical setting with participants recruited from the Eye Clinic of the Komfo Anokye Teaching Hospital (KATH), the second largest hospital in Ghana and a major referral centre - receiving referrals from 13 out of the 16 regions of Ghana because of its geographical location.

During the data collection phase, the study was incorporated into the daily clinical routine, and participants were recruited consecutively from the outpatient department. Participants were examined by a glaucoma specialist affiliated with KATH for eligibility. In total, 338 persons met the inclusion criteria of the study.

Ghanaians aged 45 years and older, without any corneal abnormalities, ocular infection and pterygium involving the cornea were included in the study. Persons with a history of ocular hypertension, ocular trauma and glaucoma were excluded. Only those without any history of retinal diseases such as diabetic retinopathy, epiretinal membranes, vitreomacular traction, age-related macular degeneration, hereditary macular disease, macular holes, retinal vascular diseases or glaucoma were included.

The study participants underwent the following examinations: visual acuity (VA) measurement using the Snellen or Tumbling E chart at 6 m, auto-refraction, IOP measurement with Goldmann applanation tonometry, slit-lamp biomicroscopy and fundus examination using a 90D Volks lens. Height (m) was measured with a measuring tape while the participants were bare-footed, and weight (kg) was measured using a weighing scale.

The Zeiss Cirrus HD-OCT 5000 software version 7.0.1.290 (Carl Zeiss Meditec, Dublin, California, United States) was used to examine the eyes of all study participants to determine normal values for ppRNFL thickness (µm), mGCC thickness (µm), optic disc area (mm22327

Statistical analysis

Data were anonymised before analysis and then exported into an online digitised database (Castor EDC) and were analysed using the Statistical Software for Data Science (STATA) version 17. Descriptive statistics including means, standard deviations and ranges were calculated using STATA version 17. Multivariate regression model was used to determine the relationships between retinal parameters, demographic and other non-ocular factors, while scatter plots were used to provide a graphical view of these relationships. Multiple imputation was used to complete 8% of missing data for mGCC thickness. Statistical significance was set at P < 0.05.

Ethical considerations

Ethical clearance to conduct this study was obtained from the Committee for Human Research Publication and Ethics under the School of Medical Sciences of the Kwame Nkrumah University of Science and Technology, Kumasi - Ghana (reference number: CHRPE/AP/540/17) and the Biomedical Research Ethics Committee of the University of KwaZulu-Natal (BREC/00005722/2023) before commencement of the study. Written consent was obtained from all study participants. This study was conducted according to the tenets of the Declaration of Helsinki.

Results

A total of 338 participants with a mean IOP of 14.88 ± 2.72 mmHg (range: 10-21 mmHg) and mean age of 61.86 ± 9.54 years (range: 45-89 years) satisfied the inclusion criteria of the study; of which 116 (34.3%) were males and 222 (65.7%) were females. Multivariate regression revealed no significant difference between right and left eye measurements for all measured ocular parameters (P ˃ 0.05). Therefore, all analyses were conducted on right eyes only. The refractive status of the study participants based on spherical equivalent error was plano (124), low myopia (98), moderate myopia (30), high myopia (7), low hyperopia (71) and moderate hyperopia (8).

Gender and retinal parameters

Table 1 shows the mean measurements and standard deviation of all measured retinal parameters based on gender. As shown in Table 1, there were no significant difference between gender and all measured retinal parameters (P ˃ 0.05). Therefore, Table 1 may serve as proposed normative sectoral measurements for ppRNFL; sectoral mGCC and optic disc area, rim area; cup volume and CD ratios in at risk Ghanaians for POAG.

Retinal parameter correlations with ethnicity in at-risk Ghanaians

The study participants were categorised into four major ethnic groups. Multivariate regression revealed no significant correlation between ethnicity and all measured ocular parameters - Global RNFL (P = 0.65), Global mGCC (P = 0.51), Disc area (P = 0.74), Rim area (P = 0.27), Cup volume (P = 0.31), ACDR (P = 0.49) and VCDR (P = 0.49).

Retinal parameter correlations with age in at-risk Ghanaians

Multivariate regression showed a negative correlation between age and global ppRNFL (r = -0.255, P = 0.002) as well as global mGCC (r = -0.206, P ˂ 0.001) as depicted in Figure 1. As shown in Figure 1, the regression equations were: ppRNFL = 108-0.196*AGE; suggesting an approximate 0.20 µm decline in ppRNFL per year and global mGCC = 93.2-0.23*AGE; suggesting an approximate 0.23 µm decrease in global mGCC per year in Ghanaians.

Figure 1

However, a positive correlation was observed between age and ACDR (r = +0.003, P = 0.016) and VCDR (r = +0.003, P = 0.003) as shown in Figure 1. There were no significant correlations between age, disc area (P = 0.10) and rim area (P = 0.45) and cup volume (P = 0.28).

Retinal parameter correlations with anthropometric measurements in at-risk Ghanaians

Height

A negative correlation was observed between height and rim area (r = -3.172, P = 0.014) as depicted in Figure 2. However, there were no significant correlations between height and global RNFL (P = 0.42), global mGCC (P = 0.74), disc area (P = 0.19), cup volume (P = 0.26), ACDR (P = 0.42) and VCDR (P = 0.28).

Weight

A positive correlation was observed between weight and rim area (r = +0.04, P = 0.006) as shown in Figure 3. However, there were no significant correlations between height and global RNFL (P = 0.44), global mGCC (P = 0.88), disc area (P = 0.07), cup volume (P = 0.44), ACDR (P = 0.54) and VCDR (P = 0.44).

A negative correlation was observed between BMI and rim area (r = -0.106, P = 0.0006) as shown in Figure 4. There were no significant correlations between BMI and the remaining retinal parameters measured in this study - global RNFL (P = 0.34), global mGCC (P = 0.93), disc area (P = 0.07), cup volume (P = 0.48), ACDR (P = 0.56) and VCDR (P = 0.45).

Discussion

Normative data of retinal parameters associated with glaucoma are important in identifying individuals at risk of the disease. This study reports on normative values for peripapillary retinal nerve fibre thickness, macula ganglion cell complex and optic nerve head measurements in at-risk Ghanaians for POAG.

The mean global ppRNFL measurement of 96.11 ± 9.87 µm measured in this study is slightly lower than the 102.37 ± 7.45 µm reported in a previous Ghanaian study using the Cirrus SD HD-OCT.161613,15,211621,2812

The mean ppRNFL measurements and ranges in all quadrants of the participants in this study were also relatively reduced compared to that of Ocansey et al.161616161525152112,21,2822

Peripapillary RNFL measurements were found to reduce with increasing age in this study, and this is in line with previous reports.12,15,2116,292115

There was no correlation between gender and global ppRNFL in this study. This is in accordance with previous reports.12,30,3116,28,32

The lack of a correlation between ppRNFL and all the anthropometric measurements in this study was in concordance with the findings of Rougier et al.33341535

The mean global mGCC measurement of 80.91 ± 5.6 µm recorded in this study was comparatively lower than the 104.02 ± 6.71 µm reported among Southern Nigerians with a mean age of 39.92 ±13.40 years,221714361914

According to literature, mGCC decreases with increasing age.19,22,36361419

In relation to gender, this study found no correlation between global mGCC and gender and this finding conforms to existing literature.37,38,3914

Also, there were no correlations between height, weight, BMI and global mGCC in this study and this is in concordance with the findings of Demir et al.,404142433743

The mean disc area of 2.05 ± 0.39 mm221624424521124624522211

Optic disc area did not correlate with age in this study and this is in agreement with previous studies.16,18,2116,214647474748

The mean rim area measurement of 1.52 ± 0.27 mm221624447249216,49

This study found no correlation between rim area and gender. Previous studies16,47,494850515248515248,49,5149

The mean cup volume measurement of 0.13 ± 0.12 mm3316320344473533316,5320,47

The mean ACDR (0.47 ± 0.15) and VCDR (0.44 ± 0.14) recorded in this study are consistent with the 0.50 ± 0.12 (ACDR) and 0.47 ± 0.13 (VCDR) reported in a previous Ghanaian study1644204753

A relatively weak positive correlation was observed between age and ACDR and VCDR in this study. The regression equation indicates an approximate 0.2 increase in ACDR and VCDR per 100 years, which is evidently negligible. Ocansey et al.16542116215554,56,57,5848

Although the risk of developing glaucoma is largely influenced by age, the disease is also prevalent among relatively younger persons. This study is limited by the fact that it only included persons 45 years and older.

Although this study found no ethnic variations among all measured ocular parameters in Ghanaians, the study was underpowered to present a firm conclusion on this because of the fact that there was not an equal representation of the various Ghanaian ethnic groups in this study. Hence, future studies should have an equal representation of the various Ghanaian ethnic groups in order to confirm the findings of this study.

Conclusion

The findings of this study present normative reference values for retinal parameters associated with glaucoma in a Ghanaian population. Ghanaians, like other Africans, have thicker global and sectoral ppRNFL and mGCC measurements as well as larger optic disc areas, ACDR and VCDR than other ethnicities. We recommend the inclusion of these retinal variable into the normative database of the Zeiss Cirrus OCT, in order to allow for early detection of pre-perimetric glaucoma in Ghanaians and Africans to minimise the misdiagnosis. The physiologically large optic disc cups as glaucoma may also inform this concern.

Competing interests

The authors declare that they have no financial or personal relationships that may have inappropriately influenced them in writing this article. The author, A.J.M., serves as an editorial board member of this journal. The peer review process for this submission was handled independently, and the author had no involvement in the editorial decision-making process for this manuscript. The authors have no other competing interests to declare.

Authors' contributions

D.N.-A., K.P.M. and A.J.M. were involved in conceptualising, designing and preparing the draft article. D.N.-A. collected the data. D.N.-A., K.P.M. and A.J.M. made equal contributions in writing this article.

Funding information

The GIGA Study, of which this study is a subset, received grants from Brightfocus Foundation, Combined Ophthalmic Research Rotterdam, Rotterdamse Oogheelkundige Onderzoeks Stichting and Landelijke Stichting voor Blinden en Slechtzienden through the Uitzicht Foundation.

Data availability

The data that support the findings of this study are available on request from the corresponding author, D.N.-A.

Disclaimer

The views and opinions expressed in this article are those of the authors and are the product of professional research. It does not necessarily reflect the official policy or position of any affiliated institution, funder, agency, or that of the publisher. The authors are responsible for this article's results, findings, and content.

Acknowledgements

The authors are grateful to the management and staff of the Eye Clinic of the Komfo Anokye Teaching Hospital (KATH). The GIGA Consortium includes Caroline Klaver (C.K.), Alberta Thiadens (A.T.), Pieter Bonnemaijer (P.B.), Sjoerd Jan Driessen (S.J.D.) from the Ophthalmology and Epidemiology, Erasmus MC, the Netherlands and Angelina Ampong (A.A.) from the Ophthalmology, Komfo Anokye Teaching Hospital, Kumasi, Ghana. The GIGA Study (of which this study is a subset) was conceptualised and designed by C.K., A.T., and P.B. Funding was secured by C.K. and A.T. A.A. and S.J.D. assisted in data collection.

References

  • 1.Bonnemaijer PW, Lo Faro V, Sanyiwa AJ, et al. Differences in clinical presentation of primary open-angle glaucoma between African and European populations. Act ophthalmol. 2021;99(7):e1118-e1126. https://doi.org/10.1111/aos.14772
    » https://doi.org/10.1111/aos.14772
  • 2.Jacobs DS, Trobe J, Park L. Open-angle glaucoma: Epidemiology, clinical presentation, and diagnosis [homepage on the Internet]. UpToDate. 2015 [cited]. Available from: https://www.uptodate.com/contents/open-angle-glaucoma-epidemiology-clinical-presentation-and-diagnosis.
    » https://www.uptodate.com/contents/open-angle-glaucoma-epidemiology-clinical-presentation-and-diagnosis
  • 3.Alward WL. Open angle glaucomas. In: Alward WLM, editor. Glaucoma: The requisites in ophthalmology. St. Louis: Mosby, 2000; p. 128-140.
  • 4.Khurana AK. Comprehensive ophthalmology. 4th ed. New Delhi: New Age International (P) Limited; p. 210-211.
  • 5.Ekstrom C. Risk factors for incident open-angle glaucoma: A population-based 20-year follow-up study. Act Ophthalmol. 2012;90(4):316-321. https://doi.org/10.1111/j.1755-3768.2010.01943.x
    » https://doi.org/10.1111/j.1755-3768.2010.01943.x
  • 6.Ntim-Amponsah CT, Amoaku WM, Ofosu-Amaah S, et al. Prevalence of glaucoma in an African population. Eye (Lond). 2004;18(5):491-497. https://doi.org/10.1038/sj.eye.6700674
    » https://doi.org/10.1038/sj.eye.6700674
  • 7.Budenz DL, Barton K, Whiteside-de Vos J, et al. Prevalence of glaucoma in an urban West African population: The Tema Eye Survey. Ophthalmol. 2013;131(5):651-658. https://doi.org/10.1001/jamaophthalmol.2013.1686
    » https://doi.org/10.1001/jamaophthalmol.2013.1686
  • 8.Tatham AJ, Medeiros FA, Zangwill LM, et al. Strategies to improve early diagnosis in glaucoma. Prog brain res. 2015;221:103-133. https://doi.org/10.1016/bs.pbr.2015.03.001
    » https://doi.org/10.1016/bs.pbr.2015.03.001
  • 9.Devereux JG, Foster PJ, Baasanhu J, et al. Anterior chamber depth measurement as a screening tool for primary angle-closure glaucoma in an East Asian population. Ophthalmology. 2000;118(2):257-263. https://doi.org/10.1001/archopht.118.2.257
    » https://doi.org/10.1001/archopht.118.2.257
  • 10.Doughty MJ, Zaman ML. Human corneal thickness and its impact on intraocular pressure measures: A review and meta-analysis approach. Surv Ophthalmol. 2000;44(5):367-408. https://doi.org/10.1016/S0039-6257(00)00110-7
    » https://doi.org/10.1016/S0039-6257(00)00110-7
  • 11.Lee RY, Kao AA, Kasuga T, et al. Ethnic variation in optic disc size by fundus photography. Curr Eye Res 2013;38(11):1142-1147. https://doi.org/10.3109/02713683.2013.809123
    » https://doi.org/10.3109/02713683.2013.809123
  • 12.Alasil T, Wang K, Keane PA, et al. Analysis of normal retinal nerve fiber layer thickness by age, sex, and race using spectral domain optical coherence tomography. J Glaucoma. 2013;22(7):532-541. https://doi.org/10.1097/IJG.0b013e318255bb4a
    » https://doi.org/10.1097/IJG.0b013e318255bb4a
  • 13.AlSaad MM, Shatarat AT, AlRyalat SA. Normative values of the retinal macular thickness in a middle eastern population. BMC Ophthalmol. 2020;20(1):1-6. https://doi.org/10.1186/s12886-020-01391-3
    » https://doi.org/10.1186/s12886-020-01391-3
  • 14.Tham YC, Chee ML, Dai W, et al. Profiles of ganglion cell-inner plexiform layer thickness in a multi-ethnic Asian population: The Singapore epidemiology of eye diseases study. Ophthalmology. 2020;127(8):1064-1076. https://doi.org/10.1016/j.ophtha.2020.01.055
    » https://doi.org/10.1016/j.ophtha.2020.01.055
  • 15.Mashige KP, Oduntan OA. A review of the human retina with emphasis on nerve fibre layer and macula thiscknesses. Afr Vis Eye Health. 2016;75(1):a330. https://doi.org/10.4102/aveh.v75i1.330
    » https://doi.org/10.4102/aveh.v75i1.330
  • 16.Ocansey S, Abu EK, Owusu-Ansah A, et al. Normative values of retinal nerve fibre layer thickness and optic nerve head parameters and their association with visual function in an African population. J Ophthalmol. 2020;2020:7150673. https://doi.org/10.1155/2020/7150673
    » https://doi.org/10.1155/2020/7150673
  • 17.Rolle T, Briamonte C, Curto D, et al. Ganglion cell complex and retinal nerve fiber layer measured by fourier-domain optical coherence tomography for early detection of structural damage in patients with preperimetric glaucoma. Clin Ophthalmol. 2011;5:961-969. https://doi.org/10.2147/OPTH.S20249
    » https://doi.org/10.2147/OPTH.S20249
  • 18.Marsh BC, Cantor LB, WuDunn D, et al. Optic nerve head (ONH) topographic analysis by stratus OCT in normal subjects: Correlation to disc size, age, and ethnicity. J Glaucoma. 2010;19(5):310-318. https://doi.org/10.1097/IJG.0b013e3181b6e5cd
    » https://doi.org/10.1097/IJG.0b013e3181b6e5cd
  • 19.Mwanza JC, Durbin MK, Budenz DL, et al. Profile and predictors of normal ganglion cell-inner plexiform layer thickness measured with frequency-domain optical coherence tomography. Invest Ophthalmol Vis Sci. 2011;52(11), 7872-7879. https://doi.org/10.1167/iovs.11-7896
    » https://doi.org/10.1167/iovs.11-7896
  • 20.Tariq YM, Li H, Burlutsky G, et al. Retinal nerve fiber layer and optic disc measurements by spectral domain OCT: Normative values and associations in young adults. Eye. 2012;26(12):1563-1570. https://doi.org/10.1038/eye.2012.216
    » https://doi.org/10.1038/eye.2012.216
  • 21.O'Rese JK, Girkin CA, Budenz DL. Effect of race, age, and axial length on optic nerve head parameters and retinal nerve fiber layer thickness measured by cirrus HD-OCT. Arch Ophthalmol 2012;130(3):312-318. https://doi.org/10.1001/archopthalmol.2011.1576
    » https://doi.org/10.1001/archopthalmol.2011.1576
  • 22.Obasuyi OC, Osuji UE, Ifijen CO, et al. Optical coherence tomography retinal nerve fibre layer and ganglion cell complex measurements in normal Southern Nigerian Eyes. Cureus. 2022;14(12):e33101. https://doi.org/10.7759/cureus.33101
    » https://doi.org/10.7759/cureus.33101
  • 23.Zouache MA, Faust CD, Silvestri V, et al. Retinal and choroidal thickness in an indigenous population from Ghana: Comparison with individuals with European or African ancestry. Ophthalmol Sci. 2024;4(2):100386. https://doi.org/10.1016/j.xops.2023.100386
    » https://doi.org/10.1016/j.xops.2023.100386
  • 24.Ismail S, Ally N, Alli HD. Retinal nerve fibre layer thickness in a normal black South African population. Eye. 2020;34(8):1426-1431.
  • 25.Sani RY, Abdu L, Pam V. Retinal nerve fiber layer thickness measurements of normal Northern Nigerian adults using optical coherence tomography. Ann Afr Med. 2016;15(2):52. https://doi.org/10.4103/1596-3519.172557
    » https://doi.org/10.4103/1596-3519.172557
  • 26.Mahmud-Ajeigbe FA, AbdulRahman HA, Rafindadi AL, et al. Retinal nerve fibre layer measurements in normal eyes in Zaria using optical coherence tomography. Sub Saharan Afr J Med. 2015;2(2):85. https://doi.org/10.4103/2384-5147.157430
    » https://doi.org/10.4103/2384-5147.157430
  • 27.Budenz DL. Signal strength, important factor when analyzing OCT scans. Ophthalmology Times, 2016.
  • 28.Budenz DL, Anderson DR, Varma R, et al. Determinants of normal retinal nerve fiber layer thickness measured by stratus OCT. Ophthalmology. 2007;114(6):1046-1052. https://doi.org/10.1016/j.ophtha.2006.08.046
    » https://doi.org/10.1016/j.ophtha.2006.08.046
  • 29.Nousome D, Mckean-Cowdin R, Richter GM, et al. Retinal nerve fiber layer thickness in healthy eyes of black, Chinese, and Latino Americans: A population-based multiethnic study. Ophthalmology. 2021;128(7):1005-1015. https://doi.org/10.1016/j.ophtha.2020.11.015
    » https://doi.org/10.1016/j.ophtha.2020.11.015
  • 30.Malik A, Singh M, Arya SK, et al. Retinal nerve fiber layer thickness in Indian eyes with optical coherence tomography. Nepal J Ophthalmol. 2012;4(1):59-63. https://doi.org/10.3126/nepjoph.v4i1.5852
    » https://doi.org/10.3126/nepjoph.v4i1.5852
  • 31.Cubuk M, Sahinoglu-Keskek N, Keskek SO. Retinal nerve fiber layer thickness in a healthy Turkish population measured by optical coherence tomography. Ann Saudi Med. 2016;36(6):409-413. https://doi.org/10.5144/0256-4947.2016.409
    » https://doi.org/10.5144/0256-4947.2016.409
  • 32.Leung CK, Mohamed S, Leung KS, et al. Retinal nerve fiber layer measurements in myopia: An optical coherence tomography study. Invest Ophthalmol Vis Sci. 2006;47(12):5171. https://doi.org/10.1167/iovs.06-0545
    » https://doi.org/10.1167/iovs.06-0545
  • 33.Rougier MB, Korobelnik JF, Malet F, et al. Retinal nerve fibre layer thickness measured with SD-OCT in a population-based study of French elderly subjects: The A lienor study. Acta Ophthalmol. 2015;93(6):539-545. https://doi.org/10.1111/aos.12658
    » https://doi.org/10.1111/aos.12658
  • 34.Zhao L, Wang Y, Chen CX, et al. Retinal nerve fibre layer thickness measured by S pectralis spectral-domain optical coherence tomography: The Beijing Eye Study. Act ophthalmol. 2014;92(1):e35-e41. https://doi.org/10.1111/aos.12240
    » https://doi.org/10.1111/aos.12240
  • 35.Wu J, Du Y, Lin C, et al. Retinal nerve fibre layer thickness measured with SD-OCT in a population-based study: The Handan Eye Study. Br J Ophthalmol. 2023;107(8):1156-1164. https://doi.org/10.1136/bjophthalmol-2021-320618
    » https://doi.org/10.1136/bjophthalmol-2021-320618
  • 36.Zhang X, Francis BA, Dastiridou A, et al. Longitudinal and cross-sectional analyses of age effects on retinal nerve fiber layer and ganglion cell complex thickness by Fourier-domain OCT. Transl Vis Sci & Technol. 2016;5(2):1.
  • 37.Bloch E, Yonova-Doing E, Jones-Odeh E, et al. Genetic and environmental factors associated with the ganglion cell complex in a healthy aging British cohort. JAMA Ophthalmol. 2017;135(1):31-38. https://doi.org/10.1001/jamaophthalmol.2016.4486
    » https://doi.org/10.1001/jamaophthalmol.2016.4486
  • 38.Huo YJ, Guo Y, Li L, et al. Age-related changes in and determinants of macular ganglion cell-inner plexiform layer thickness in normal Chinese adults. Clin Exp Ophthalmol. 2018;46(4):400-406. https://doi.org/10.1111/ceo.13067
    » https://doi.org/10.1111/ceo.13067
  • 39.Xu X, Xiao H, Lai K, et al. Determinants of macular ganglion cell-inner plexiform layer thickness in normal Chinese adults. BMC Ophthalmol. 2021;21(1):267. https://doi.org/10.1186/s12886-021-02023-0
    » https://doi.org/10.1186/s12886-021-02023-0
  • 40.Demir S, Özer S, Alim S, et al. Retinal nerve fiber layer and ganglion cell-inner plexiform layer thickness in children with obesity. Int J Ophthalmol. 2016;9(3):434.
  • 41.Baran RT, Baran SO, Toraman NF, et al. Evaluation of intraocular pressure and retinal nerve fiber layer, retinal ganglion cell, central macular thickness, and choroidal thickness using optical coherence tomography in obese children and healthy controls. Niger J Clin Pract. 2019;22(4):539-545. https://doi.org/10.4103/njcp.njcp_471_18
    » https://doi.org/10.4103/njcp.njcp_471_18
  • 42.Paulsen AJ, Pinto A, Merten N, et al. Factors associated with the macular ganglion cell-inner plexiform layer thickness in a cohort of middle-aged U.S. Adults. Optom Vis Sci. 2021;98(3):295-305. https://doi.org/10.1097/OPX.0000000000001650
    » https://doi.org/10.1097/OPX.0000000000001650
  • 43.Von Hanno T, Hareide LL, Småbrekke L, et al. Macular layer thickness and effect of BMI, body fat, and traditional cardiovascular risk factors: The Tromsø study. Invest Ophthalmol Vis Sci. 2022;63(9):16. https://doi.org/10.1167/iovs.63.9.16
    » https://doi.org/10.1167/iovs.63.9.16
  • 44.Gessesse GW, Debela AS, Anbesse DH. Retinal nerve fiber layer thickness and optic disc parameters measured by Cirrus HD OCT among adults attending St. Paul's Hospital Medical College. Millenn J Health. 2022;2(1):2790-1378.
  • 45.Girkin CA, Sample PA, Liebmann JM, et al. African Descent and Glaucoma Evaluation Study (ADAGES): II. Ancestry differences in optic disc, retinal nerve fiber layer, and macular structure in healthy subjects. Arch Ophthalmol. 2010;128(5):541-550. https://doi.org/10.1001/archophthalmol.2010.49
    » https://doi.org/10.1001/archophthalmol.2010.49
  • 46.Awe OO, Onakpoya OH, Adeoye AO. Optic disc morphometry using spectral domain optical coherence tomography in a Nigerian population. Eur J Ophthalmol. 2022;32(2):1194-1200. https://doi.org/10.1177/11206721211008781
    » https://doi.org/10.1177/11206721211008781
  • 47.Zhang Q, Li S, Liang Y, et al. Characteristics of optic disc parameters and its association in normal Chinese population: The Handan Eye Study. Chin Med J. 2014;127(9):1702-1709. https://doi.org/10.3760/cma.j.issn.0366-6999.20133312
    » https://doi.org/10.3760/cma.j.issn.0366-6999.20133312
  • 48.Zheng Y, Cheung CY, Wong TY, et al. Influence of height, weight, and body mass index on optic disc parameters. Invest Ophthalmol Vis Sci. 2010;51(6):2998-3002. https://doi.org/10.1167/iovs.09-4470
    » https://doi.org/10.1167/iovs.09-4470
  • 49.Jonas JB, Nangia V, Gupta R, et al. Retinal nerve fibre layer cross-sectional area, neuroretinal rim area and body mass index. Act Ophthalmol. 2014;92(3):e194-e199. https://doi.org/10.1111/aos.12297
    » https://doi.org/10.1111/aos.12297
  • 50.Ramrattan RS, Wolfs RC, Jonas JB, et al. Determinants of optic disc characteristics in a general population: The Rotterdam study. Ophthalmology. 1999;106(8):1588-1596. https://doi.org/10.1016/S0161-6420(99)90457-8
    » https://doi.org/10.1016/S0161-6420(99)90457-8
  • 51.Xu L, Wang YX, Wang S, et al. Neuroretinal rim area and body mass index. PLoS One. 2012;7(1):e30104. https://doi.org/10.1371/journal.pone.0030104
    » https://doi.org/10.1371/journal.pone.0030104
  • 52.Jonas JB, Gründler AE, Papastathopoulos KI. Optic disc dimensions, body length, and body weight. Br J Ophthalmol. 1998;82(2):196. https://doi.org/10.1136/bjo.82.2.196a
    » https://doi.org/10.1136/bjo.82.2.196a
  • 53.Pilat AV, Gottlob I, Sheth V, et al. Gender-and ethnicity-related differences in optic nerve head topography in healthy Indian and Caucasian participants. Neuro-Ophthalmol. 2014;38(4):205-212. https://doi.org/10.3109/01658107.2014.894535
    » https://doi.org/10.3109/01658107.2014.894535
  • 54.Kuang TM, Liu CJ, Ko YC, et al. Distribution and associated factors of optic disc diameter and cup-to-disc ratio in an elderly Chinese population. Chin Med J. 2014;77(4):203-208. https://doi.org/10.1016/j.jcma.2014.01.006
    » https://doi.org/10.1016/j.jcma.2014.01.006
  • 55.Amerasinghe N, Wong TY, Wong WL, et al. Determinants of the optic cup to disc ratio in an Asian population: The Singapore Malay Eye Study (SiMES). Arch Ophthalmol. 2008;126(8):1101-1108. https://doi.org/10.1001/archopht.126.8.1101
    » https://doi.org/10.1001/archopht.126.8.1101
  • 56.Pedro-Egbe CN, Awoyesuku EA. The relationship between vertical cup-disc ratio and body mass index in Port Harcourt, Nigeria. Niger J Clin Pract. 2013;16(4):517-520. https://doi.org/10.4103/1119-3077.116904
    » https://doi.org/10.4103/1119-3077.116904
  • 57.Fukuoka H, Tange C, Otsuka R, et al. The impact of anthropometric and ocular parameters on optic cup-to-disc ratio. BMJ Open Ophthalmol. 2017;1(1):e000012. https://doi.org/10.1136/bmjophth-2016-000012
    » https://doi.org/10.1136/bmjophth-2016-000012
  • 58.Al Wadani F, Feroze KB, Al Yahya R. The relationship between vertical cup-disc ratio and body mass index in a population of adult Saudi females. Niger J Ophthalmol. 2018;26(2):121-127. https://doi.org/10.4103/njo.njo_6_18
    » https://doi.org/10.4103/njo.njo_6_18

Correspondence:
Doreen Nelson-Ayifah

Received: 24 May 2024
Accepted: 10 Oct. 2024
Published: 30 Nov. 2024

Correspondence

nelsdayy@gmail.com

Publication Dates

  • Publication in this collection
    15 Jan 2025
  • Date of issue

History

  • Received
    24 May 2024
  • Accepted
    10 Oct 2024
location_on
AOSIS Publishing AOSIS Publishing, 15 Oxford Street, Durbanville, Cape Town, Western Cape, ZA, 7550, Tel: +27 21 975 2602 - E-mail: publishing@aosis.co.za
rss_feed Stay informed of issues for this journal through your RSS reader
Go to top