Sumário
SAIEE Africa Research Journal, Volume: 115, Número: 1, Publicado: 2024SAIEE Africa Research Journal, Volume: 115, Número: 1, Publicado: 2024
| Documents |
|---|
|
Articles Self-Synchronizing On-Off-Keying Visible Light Communication System For Intra- and Inter-Vehicle Data Transmission Achari, S. Yang, A.Y. Goodhead, J. Swanepoel, B. Cheng, L. Resumo em Inglês: Visible light communication is a present technology which allows data to be transmitted by modulating information onto a light source. It has many advantages over traditional radio frequency communication and up to 10,000 times larger bandwidth. Many existing research in visible light communication assumes a synchronized channel, however, this is not always easily achieved. This paper proposes a novel synchronized VLC system with the potential to ensure reliable communication in both intra- and inter-vehicle communication. The protocol achieves synchronization at the symbol level using the transistor-transistor logic protocol and achieves frame synchronizations with markers. Consequently, the deployment of the system in both intra- and inter-vehicle communication may present numerous advantages over existing data transmission processes. A practical application where visible light communication is used for media streaming is also previewed. In addition, various regions of possible data transmission are determined to infer forward error correction schemes to ensure reliable communication. |
|
Articles Green Hydrogen: A Clean Energy Solution for Germany's Transportation Sector Asiegbu, A.D. Kahn, M.T.E. Almaktoof, A.M. Resumo em Inglês: The need for sustainable and environmentally friendly energy sources is very important if future generations are to be spared of the misdoings of past generations. Climate change, environmental pollution, radiation pollution, and altering of the balanced ecology of the green planet earth is now a significant challenge, because if not mitigated, some island nations will disappear in the future, due to human activities energized by unsustainable fossil fuels. Based on these facts, Germany has taken concrete and important steps to stem the tide of this ill wind by embracing the Green Hydrogen system. This is more obvious in the transport system that produces more than 40% of Green House Gases in Europe. Because Germany is an industrialized European nation, the government has introduced Green Hydrogen for transportation in accordance with European Union energy policy. Therefore, this paper provides a clear, concise analysis and implementation of Green Hydrogen energy in the smart energy system. The paper presents Green Hydrogen analysis in transportation in four sections, namely, Geographical, Chemical, social, and economic aspects, respectively. The last section of this paper is the discussion of results from cost/feasibility analysis, which shows that although the expected or forecasted GH cost is US$7.11per kg from 2020 to 2050, the current growth in the green hydrogen infrastructure and technology, reduced the overall cost of GH in 2020 to $1.60/kg. An erudite conclusion and recommendations are made at the end of this research. |
|
Articles Evaluation of unconventional partial discharge and Tan Delta assessment techniques on medium voltage cable terminations with artificial defects Bissett, J.V. van Vuuren, P.A. Walker, J.J. Resumo em Inglês: Reliable cable systems are of utmost importance for electricity distribution- and grid networks. Cable terminations are key components of cable systems but also contribute significantly towards unwanted cable failures and power outages. Although well-developed standards exist in the electricity industry, it is not always possible to execute the most effective tests at power frequency due to financial or logistical reasons. Hence, withstand voltage- and Partial Discharge tests at power frequency are only conducted at a low percentage of electricity utilities. This paper presents the evaluation of unconventional partial discharge fault detection techniques and Very Low Frequency Tan Delta measurements on different cable termination defects. Five artificial cable termination defects were created on single core 6.35/11kV cross linked polyethylene cables, with one "defect-free" termination and five defective ones. Power frequency voltage was applied at increased voltage steps to initiate aging acceleration due to partial discharge. This resulted in insulation deterioration and eventual termination failure. Different data sets were obtained from the Very Low Frequency Tan Delta measurements as well as for the unconventional Partial Discharge measurements. The sequence of failures is compared between the two data sets and evaluated against the root cause failures of the terminations as evaluated by an industry expert. High Frequency Current Transformer and capacitive coupling sensors were used together with an advanced partial discharge data acquisition system. Partial discharge analysis was done to relate the specific on-line trending data with termination failure. Good correlation was found between the two data sets which supports the utilization of unconventional partial discharge measurement for cable acceptance testing. It would be beneficial for the electricity industry to consider unconventional Partial Discharge technology as a suitable alternative for on-site acceptance tests for cable terminations. |
Leia a Declaração de Acesso Aberto
