Tabla de contenido
SAIEE Africa Research Journal, Volumen: 113, Numero: 3, Publicado: 2022SAIEE Africa Research Journal, Volumen: 113, Numero: 3, Publicado: 2022
| Documents |
|---|
|
Articles A New Method to Distinguish between Nearby and Direct Lightning Strikes for Long Operational Medium Voltage Lines Dirkse van Schalkwyk, Willem J. Gomes, Chandima van Coller, John M. Resumen en Inglés: Lightning strikes near Medium Voltage (MV) electricity distribution lines cause voltage transients to be induced onto the conductors of the power lines. The resultant Lightning Induced Overvoltage (LIOV) on the phase conductors may be estimated using computer models or measurements. Models and measurements are mostly limited to short floating lines to simplify calculations and to ensure accurate results that can be easily compared between different models. Existing measurement methods cannot be used to distinguish between nearby lightning and direct lightning strikes to an operational MV network by using only one instrument on a line that is more than 100 km long. The instrument needs to be less than a hundred meters from where the LIOV amplitude on the line is the highest. The new method described in this paper allows one to distinguish between nearby and direct lightning strikes to the line; by comparing the polarity of the current transient recorded at the substation to the lightning return-stroke polarity obtained from a lightning detection network. The new method also allows one to determine whether the LIOV of a particular lightning transient exceeded the Basic Insulation Level (BIL) of the line, by observing the power frequency fault current. The new method was applied to an operational 714 km network operating at 22 kV, and the results were compared with predictions in IEEE Std 1410-2010. Significantly fewer line faults due to nearby lightning were observed than predicted; the reason for this is explained. |
|
Articles Substrate Integrated Waveguide - Dielectric Resonator Antenna for Future Wireless Communication Chemweno, Emmanuel K. Kumar, Pradeep Afullo, Thomas J. O. Resumen en Inglés: A substrate integrated waveguide (SIW) fed rectangular-shaped dielectric resonator antenna (DRA) is proposed for application in the D - Band frequency regime. The Dielectric Resonator (DR) is designed to operate in higher order modes. A rectangular-shaped narrow slot is used to excite the DR element, leading to multiple resonances. The resulting structure is a multi-resonant antenna operating at six frequencies at 123.64 GHz, 125.76 GHz, 127.4 GHz, 129.9 GHz, 134.9 GHz and 137.7 GHz frequencies. These are identified as TE10δ1, TE7δ5, TEδ31, TEδ25, TEδ31 and TEδ35 modes of operation of the resonator, respectively. These resonances are merged to achieve a -10 dB impedance bandwidth ranging between 122.58 GHz and 139.51 GHz, equivalent to 13.4% at a center frequency of 125.76 GHz. Moreover, the antenna possesses a stable radiation pattern in the broadband direction, across the entire frequency band of operation. Simulation results show that the antenna has a peak gain of 12.3 dBi, maximum directivity of 13.14 dBi and maximum efficiency of 84% at a frequency of 126 GHz. Simulated results show that the proposed design has potential and suitability for utilization in future wireless communications. |
|
Articles Research on Payment Settlement Mode in Cross-Border Business Trade Based on Blockchain Technology Wang, Xiaoyan Resumen en Inglés: Cross-border commerce trade is an important part of economic development, and its payment and settlement mode has received widespread attention. The traditional payment settlement mode has shortcomings such as low efficiency, high cost and poor security; therefore, it needs to be improved. In view of this, this paper studied the payment settlement model based on blockchain technology. This paper firstly introduced blockchain, then analysed its characteristics and composition and the possibility of its application in cross-border business trade, and finally took the Ripple payment settlement mode as an example for a case study. The analysis found that the Ripple mode had small time and capital costs, high transaction transparency and security, and simple and convenient processes. The analysis results verify the reliability of the blockchain-based payment settlement mode and its applicability in in practice. |
Lea la Declaración de Acceso abierto
