Tabla de contenido
African Journal of Laboratory Medicine, Volumen: 11, Numero: 1, Publicado: 2022African Journal of Laboratory Medicine, Volumen: 11, Numero: 1, Publicado: 2022
| Documents |
|---|
|
Original Research Commercial DURAClone panels for extending the repertoire of multicolour immunophenotypic panels in an academic flow cytometry laboratory in South Africa Swart, Leanne Pretorius, Melanie Lawrie, Denise Glencross, Deborah K. Resumen en Inglés: BACKGROUND: Commercial multicolour fixed immunophenotyping panels can improve flow cytometric diagnostic immunophenotyping repertoire. OBJECTIVE: This study validated the commercially available, standardised Beckman Coulter lyophilised DURAClone RE panels to discriminate specific haematolymphoid subtypes. METHODS: We compared the diagnostic capability of the DURAClone acute leukaemia B (ALB), chronic leukaemia B (CLB), and plasma cells (PC) panels to the predicate second-line panels in Charlotte Maxeke Johannesburg Academic Hospital, Johannesburg, South Africa, from April to August 2020. Clinical diagnostic concordance between the in-house second-line immunophenotyping (the predicate method) and DURAClone was established. The ALB panels tested for precursor B-cell acute lymphoblastic leukaemia (n = 11) or normal bone marrow haematogones (n = 9); CLB panels established haematolymphoid subtypes of mature B-cell lymphoproliferative disorders (B-LPD) (n = 20), while PC panels detected plasma cell dyscrasias (PCD) (n = 17). Flow cytometer setup and data interpretation to discriminate normal and aberrant immunophenotypes were per manufacturer's instructions. RESULTS: There was 100% clinical diagnostic concordance between the predicate and the test panels for second-line diagnostic investigation of B-ALL (with additional CD56), mature B-LPD (with additional discernment of CD81, ROR-1, CD79b and CD43) and PCD CONCLUSION: The DURAClone CLB exceeded the predicate second-line performance, offering extended second-line diagnostic discernment of mature B-LPD subtypes and discernment of CD5+ B-LPD from other non-CD5+ (or CD5-) B-LPD; likewise, the PC panels enabled discovery of PCD. While ALB testing offered no additional diagnostic advantage over existing predicate investigation, CD58 did offer additional information to discern haematogones from B-ALL. |
|
Original Research Practices and barriers to screening for hyperglycaemia in pregnancy among providers of antenatal care in Jos, Nigeria Imoh, Lucius C. Longwap, Abdulazis S. Haruna, Favour E. Asieba, Oghale J. Istifanus, Joy P. Imoh, Joy A. Banwat, Mathilda E. Resumen en Inglés: BACKGROUND: Screening for hyperglycaemia in pregnancy (HIP) is an important component of comprehensive antenatal care. Screening practices for HIP in Nigeria and factors that influence these practices are not well understood. OBJECTIVE: We examined the screening practices for HIP and their correlates among antenatal healthcare providers (AHPs). METHODS: This descriptive cross-sectional study of AHPs providing all levels of antenatal care was conducted between August 2019 and September 2019 in Jos, Nigeria. Eligible AHPs completed a semi-structured, self-administered questionnaire, and data were analysed for adherence to recommended screening practices such as World Health Organization, International Association of Diabetes and Pregnancy Study Groups and National Institute for Health and Care Excellence guidelines RESULTS: Of the 128 respondents included in the analysis, 59 (46.1%) were male and 69 (53.9%) were female. The mean participant age was 35.7 years (standard deviation: ± 8.5 years). Most (68.0%) screened all pregnant women (universal screening) for gestational diabetes mellitus. Fasting blood glucose (77.0%) and random blood glucose (55.7%) were the most common tests used. Only 27 respondents (22.1%) screened using the 75 g oral glucose tolerance test, and most were doctors, AHPs in faith-based or government institutions, tertiary institutions and facilities with availability of automated glucose analysers (p < 0.05 for all). CONCLUSION: Screening practices for HIP among the AHPs do not generally conform to best practices. Hence, there is an urgent need for implementation of universal guidelines and provision of regular updates and basic glucose measuring devices for AHPs at all healthcare levels. |
|
Lessons from the Field Tuberculosis-loop-mediated isothermal amplification implementation in Cameroon: Challenges, lessons learned and recommendations Donkeng-Donfack, Valerie F. Ongoulal, Suzanne M. Djieugoue, Yvonne J. Simo, Yannick Kamdem Manga, Henri Tollo, Danielle A.D. Belinga, Edwige M.A. Mbassa, Vincent Abena, Jean L. Eyangoh, Sara Resumen en Inglés: BACKGROUND: Until 2016, microscopy was the main tool for the early detection of pulmonary tuberculosis in Cameroon, especially in remote settings. Due to the poor sensitivity of microscopy, there was a need to implement a molecular assay in order to improve tuberculosis case detection. INTERVENTION: In 2017, tuberculosis loop-mediated isothermal amplification (TB-LAMP), a molecular rapid diagnostic test recommended by the World Health Organization, was implemented in Cameroon as a replacement test of microscopy for initial diagnosis of pulmonary tuberculosis and also as a follow-on test to microscopy for smear-negative sputum specimens. A roll out plan for TB-LAMP implementation in Cameroon had been developed from January 2017 to April 2017, followed by initial implementation at four sites in May 2017. Additional sites were added progressively. LESSONS LEARNT: The use of TB-LAMP as a follow-on test to microscopy for smear-negative sputum specimens helped in the detection of tuberculosis in 14.77% of those who were sputum-smear negative in 2019. Tuberculosis-loop-mediated isothermal amplification usage as an initial test, followed by testing with Xpert MTB/RIF for rapid tuberculosis and rifampicin resistance detection during tuberculosis mass screening campaigns, reduced the turn-around time by 73.23% as compared to when the Gene Xpert instrument was used alone. RECOMMENDATIONS: The implementation and scaling up of TB-LAMP in Cameroon contributed to increase access to tuberculosis molecular diagnosis in remote settings and as such improved tuberculosis case notification. However, to better enhance this notification and optimise the use of a TB-LAMP instrument, a suitable sample transport system is recommended. |
|
Editorial Point-of-care testing: Connecting communities in Africa and ensuring equity in access to health and diagnostics Erasmus, Rajiv T. |
|
Original Research Causes of death and post-mortem testing for SARS-CoV-2 in a tertiary hospital during the COVID-19 pandemic in Ghana Asumanu, Edward Attoh, Seth Servor, Raymond X. Laryea, Clement McAddy, Mary Hobenu, Fred Factchu, Raymond Agyemang-Bediako, Kwesi Nyarko, Edward O. Nyarko, Godwin K. Moroti, Marcus K. Edusei, Lawrence Resumen en Inglés: BACKGROUND: Causes of death during the coronavirus disease 2019 (COVID-19) pandemic ranhttp://crossmark.crossref.org/dialog/?doi=10.4102/ajlm.v11i1.1766=pdf_stamp=2022-11-23ge from direct consequences of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection to deaths unrelated to SARS-CoV-2. Another feature of the pandemic is the post-mortem testing for SARS-CoV-2. Understanding these aspects of COVID-19 are essential in planning and limiting the impact of SARS-CoV-2 virus on healthcare systems OBJECTIVE: This study investigated the underlying causes of death and the presence of SARS-CoV-2 in bodies received at the 37 Military Hospital, Accra, Ghana, during the COVID-19 pandemic. METHODS: The study was conducted from 4-27 May 2020. Deceased patients that met the inclusion criteria were prospectively selected during the expanded surveillance period for SARS-CoV-2 testing, autopsy and determination of underlying and immediate cause of death RESULTS: A total of 161 deceased patients were analysed with 53 autopsies. The overall positive test rate for SARS-CoV-2 was 14.9% (24/161 patients), with a positive rate of 5.0% (8/161 patients) for nasopharyngeal samples and 30.2% (16/161 patients) for bronchopulmonary samples. The underlying causes of death were not related to SARS-CoV-2 infection in 85.1% (137/161) of patients, SARS-CoV-2-associated 12.4% (20/161) and SARS-CoV-2-induced in 2.5% (4/161). Cardiovascular complications formed the most common cause of death in patients with or without SARS-CoV-2. CONCLUSION: There was a high positive rate of SARS-CoV-2 in post-mortem cases. However, most deaths were not caused by SARS-CoV-2 but by cardiovascular complications. The high rate of bronchopulmonary positive results for SARS-CoV-2 requires that autopsies be done in suspicious cases with negative nasopharyngeal sampling. |
|
Original Research Agreement between Xpert and AmpFire tests for high-risk human papillomavirus among HIV-positive women in Rwanda Murangwa, Anthere Desai, Kanan T. Gage, Julia C. Murenzi, Gad Tuyisenge, Patrick Kanyabwisha, Faustin Musafili, Aimable Kubwimana, Gallican Mutesa, Leon Anastos, Kathryn Kim, Hae-Young Castle, Philip E. Resumen en Inglés: BACKGROUND: High-risk human papillomavirus (hrHPV) may cause more than 99% of cervical cancers worldwide. Little is known about performance differences in tests for hrHPV OBJECTIVE: This study analysed agreement for detection of hrHPV between the established, clinically validated Xpert HPV assay and the novel isothermal amplification-based AmpFire HPV genotyping assay METHODS: This study was nested in a larger project on cervical cancer screening among approximately 5000 women living with HIV in Kigali, Rwanda. This sub-study included 298 participants who underwent initial screening for cervical cancer using the Xpert HPV assay and visual inspection with acetic acid in 2017 and tested positive by either or both. Participants were rescreened using colposcopy, and cervical samples were collected between June 2018 and June 2019. Samples were then tested for HPV using the Xpert HPV assay and AmpFire HPV genotyping assay. Agreement between results from both tests was analysed using an exact version of McNemar test and chi-square test RESULTS: Overall agreement and kappa value for detection of hrHPV by Xpert and AmpFire were 89% and 0.77 (95% confidence interval: 0.70-0.85). AmpFire was marginally more likely to diagnose hrHPV-positive than Xpert (p = 0.05), due primarily to the extra positivity for HPV16 (p < 0.001 CONCLUSION: Overall, there was good to excellent agreement between the Xpert and AmpFire when testing hrHPV types among women living with HIV. AmpFire was more likely to test extra cases of HPV16, the most carcinogenic HPV type, but the clinical meaning of detecting additional HPV16 infections remains unknown |
|
Original Research Optimising courier specimen collection time improves patient access to HIV viral load testing in South Africa Girdwood, Sarah J. Crompton, Thomas Cassim, Naseem Olsen, Floyd Sejake, Portia Diallo, Karidia Berrie, Leigh Chimhamhiwa, Dorman Stevens, Wendy Nichols, Brooke Resumen en Inglés: BACKGROUND: South Africa uses a courier network for transporting specimens to public laboratories. After the daily collection of specimens from the facility by the courier, patients not yet attended to are unlikely to receive same-day blood draws, potentially inhibiting access to viral load (VL) testing for HIV patients. OBJECTIVE: We aimed to design an optimised courier network and assess whether this improves VL testing access. METHODS: We optimised the specimen transport network in South Africa for 4046 facilities (November 2019). For facilities with current specimen transport times (n = 356), we assessed the relationship between specimen transport time and VL testing access (number of annual VL tests per antiretroviral treatment patient) using regression analysis. We compared our optimised transport times with courier collection times to determine the change in access to same-day blood draws. RESULTS: The number of annual VL tests per antiretroviral treatment patient (1.14, standard deviation: 0.02) was higher at facilities that had courier collection after 13:36 (the average latest collection time) than those that had their last collection before 13:36 (1.06, standard deviation: 0.03), even when adjusted for facility size. Through network optimisation, the average time for specimen transport was delayed to 14:35, resulting in a 6% - 13% increase in patient access to blood draws. CONCLUSION: Viral load testing access depends on the time of courier collection at healthcare facilities. Simple solutions are frequently overlooked in the quest to improve healthcare. We demonstrate how simply changing specimen transportation timing could markedly improve access to VL testing. |
|
Opinion Papers The time to address diagnostic needs in universal health coverage is now: Leveraging the scale up of national testing capacity for HIV viral load and SARS-CoV-2 Marinucci, Francesco Dhein, Jens |
|
Lessons from the Field Challenges with the pursuit of ISO 15189 accreditation in a public health laboratory in Ghana Attoh, Seth Tetteh, Francis K.M. McAddy, Mary Ackah, Kingsley Kyei, Richmond Moroti, Marcus Boateng, Cynthia Adusu-Donkor, Laurinda Boafo, Joseph Yakubu, Alhassan Kwao, Sarah Sarkodie, Emmanuel Koranteng, Nana-Banyin Addo, Monica A. Hobenu, Frederick Agyeman-Bediako, Kwasi Fatchu, Raymond D. Resumen en Inglés: BACKGROUND: Accreditation is important for all medical laboratories, particularly public health laboratories in developing countries. Several laboratories in Ghana implemented the requirements of the International Organization for Standardization (ISO) 15189 but were unable to proceed to accreditation. This article describes the challenges faced by the Pathology Division Laboratory of the 37 Military Hospital, Accra, Ghana, during the acquisition of ISO 15189 accreditation and suggests solutions for a better approach. INTERVENTION: Following ISO 15189 accreditation in 2017, an online survey was conducted between 01 and 30 March 2020 among the laboratory staff. Respondents were required to grade, on a scale of 0 (least) to 5 (most), the extent to which 16 key challenges influenced the process of obtaining accreditation. Key informant interviews were also held with laboratory personnel who were directly involved in the establishment of the quality management system in the laboratory and the accreditation acquisition process. LESSONS LEARNT: Documentation, laboratory safety measures, laboratory management support, and reagent unavailability were estimated as the challenges that most affected the acquisition of laboratory accreditation. Challenges such as poor communication, staff apathy and workload had the least effect on the accreditation process. There was no difference in challenges identified between persons who worked in the laboratory before or after accreditation (p = 0.11). RECOMMENDATIONS: To surmount the anticipated challenges, there is the need for national strategic direction for laboratory accreditation, hospital and laboratory management support for the accreditation acquisition and maintenance processes, and sufficient technical assistance in the form of training and mentorship. |
|
Original Research Newly implemented community CD4 service in Tshwaragano, Northern Cape province, South Africa, positively impacts result turn-around time Coetzee, Lindi-Marie Cassim, Naseem Glencross, Deborah K. Resumen en Inglés: BACKGROUND: The Northern Cape is South Africa's largest province with an HIV prevalence of 7.1% versus a 13.5% national prevalence. CD4 testing is provided at three of five National Health Laboratory Service district laboratories, each covering a 250 km precinct radius. Districts without a local service report prolonged CD4 turn-around times (TAT OBJECTIVE: This study documented the impact of a new CD4 laboratory in Tshwaragano in the remote John Taolo Gaetsewe district of the Northern Cape, South Africa METHODS: CD4 test volumes and TAT (total, pre-analytical, analytical, and post-analytical) data for the Northern Cape province were extracted for June 2018 to October 2019. The percentage of CD4 results within the stipulated 40-h TAT cut-off and the median and 75th percentiles of all TAT parameters were calculated. Pre-implementation, samples collected at Tshwaragano were referred to Kimberley or Upington, Northern Cape, South Africa RESULTS: Pre-implementation, 95.4% of samples at Tshwaragano were referred to Kimberley for CD4 testing (36.3% of Kimberley's test volumes). Only 7.5% of Tshwaragano's total samples were referred post-implementation. The Tshwaragano laboratory's CD4 median total TAT decreased from 24.7 h pre-implementation to 12 h post-implementation (p = 0.003), with > 95.0% of results reported within 40 h. The Kimberley laboratory workload decreased by 29.0%, and testing time significantly decreased from 10 h to 4.3 h CONCLUSION: The new Tshwaragano CD4 service significantly decreased local TAT. Upgrading existing community laboratories to include CD4 testing can alleviate provincial service load and improve local access, TAT and efficiency in the centralised reference laboratory |
|
Original Research Implementation of a customised antimicrobial resistance laboratory scorecard in Cameroon, Ethiopia and Kenya Trollip, André Gadde, Renuka Datema, Tjeerd Gatwechi, Kamau Oskam, Linda Katz, Zachary Whitelaw, Andrew Kinyanjui, Peter Njukeng, Patrick Wendifraw, Dawit A. Mugerwa, Ibrahimm Najjuka, Grace Dayie, Nicholas Opintan, Japheth A. Albert, Heidi Resumen en Inglés: BACKGROUND: In low-resource settings, antimicrobial resistance (AMR) is detected by traditional culture-based methods and ensuring the quality of such services is a challenge. The AMR Scorecard provides laboratories with a technical assessment tool for strengthening the quality of bacterial culture, identification, and antimicrobial testing procedures. OBJECTIVE: To evaluate the performance of the AMR Scorecard in 11 pilot laboratory evaluations in three countries also assessed with the Stepwise Laboratory Quality Improvement Process Towards Accreditation (SLIPTA) checklist METHODS: Pilot laboratory evaluations were conducted in Cameroon, Ethiopia and Kenya between February 2019 and March 2019. Assessors with previous SLIPTA and microbiology experience were trained. Assessors performed the laboratory assessments using the SLIPTA and AMR Scorecard tools. RESULTS: Weaknesses in technical procedures and the quality management systems were identified in all areas and all laboratories. Safety had the highest mean performance score (SLIPTA: 68%; AMR Scorecard: 73%) while management review had the lowest (SLIPTA: 32%; AMR Scorecard: 8%) across all laboratories. The AMR Scorecard scores were generally consistent with SLIPTA scores. The AMR Scorecard identified technical weaknesses in AMR testing, and SLIPTA identified weaknesses in the quality management systems in the laboratories CONCLUSION: Since the AMR Scorecard identified important gaps in AMR testing not detected by SLIPTA, it is recommended that microbiology laboratories use SLIPTA and the AMR Scorecard in parallel when preparing for accreditation. Expanding the use of the AMR Scorecard is a priority to address the need for quality clinical microbiology laboratory services in support of optimal patient care and AMR surveillance. |
|
Original Research The application of sigma metrics in the laboratory to assess quality control processes in South Africa van Heerden, Marli George, Jaya A. Khoza, Siyabonga Resumen en Inglés: BACKGROUND: Laboratories use quality control processes to monitor and evaluate analytical performance in terms of precision and bias. Sigma metrics provide an objective assessment of laboratory quality using the total allowable error as an additional parameter OBJECTIVE: This study aimed to determine the sigma metrics of analytes when using different total allowable error guidelines. METHODS: A retrospective analysis was performed on 19 general chemistry analytes at Charlotte Maxeke Johannesburg Academic Hospital in South Africa between January 2017 and December 2017. Sigma metrics were calculated on two identical analysers, using internal quality control data and total allowable error guidelines from the Ricos biological variation database and three alternative sources (the Royal College of Pathologists of Australasia, the Clinical Laboratory Improvements Amendment, and the European Federation of Clinical Chemistry and Laboratory Medicine. RESULTS: The sigma performance was similar on both analysers but varied based on the guideline used, with the Clinical Laboratory Improvements Amendment guidelines resulting in the best sigma metrics (53% of analytes on one analyser and 46% on the other had acceptable sigma metrics) and the Royal College of Pathologists of Australia guidelines being the most stringent (21% and 23%). Sodium and chloride performed poorly across all guidelines (sigma < 3). There were also month-to-month variations that may result in acceptable sigma despite poor performance during certain months. CONCLUSION: The sigma varies greatly depending on the total allowable error, but could be a valuable tool to save time and decrease costs in high-volume laboratories. Sigma metrics calculations need to be standardised. |
|
Lessons from the Field COVID-19 mass testing and sequencing: Experiences from a laboratory in Western Kenya Waitumbi, John N. Omuseni, Esther Nyataya, Josphat Masakhwe, Clement Sigei, Faith Lemtudo, Allan Awinda, George Muthanje, Eric Andika, Brian Githii, Rachel Liyai, Rehema Kimita, Gathii Mutai, Beth Resumen en Inglés: BACKGROUND: The Basic Science Laboratory (BSL) of the Kenya Medical Research Institute/Walter Reed Project in Kisumu, Kenya addressed mass testing challenges posed by the emergent coronavirus disease 2019 (COVID-19) in an environment of global supply shortages. Before COVID-19, the BSL had adequate resources for disease surveillance and was therefore designated as one of the testing centres for COVID-19 INTERVENTION: By April 2020, the BSL had developed stringent safety procedures for receiving and mass testing potentially infectious nasal specimens. To accommodate increased demand, BSL personnel worked in units: nucleic acid extraction, polymerase chain reaction, and data and quality assurance checks. The BSL adopted procedures for tracking sample integrity and minimising cross-contamination LESSONS LEARNT: Between May 2020 and January 2022, the BSL tested 63 542 samples, of which 5375 (8.59%) were positive for COVID-19; 1034 genomes were generated by whole genome sequencing and deposited in the Global Initiative on Sharing All Influenza Data database to aid global tracking of viral lineages. At the height of the pandemic (August and November 2020, April and August 2021 and January 2022), the BSL was testing more than 500 samples daily, compared to 150 per month prior to COVID-19. An important lesson from the COVID-19 pandemic was the discovery of untapped resilience within BSL personnel that allowed adaptability when the situation demanded. Strict safety procedures and quality management that are often difficult to maintain became routine RECOMMENDATIONS: A fundamental lesson to embrace is that there is no 'one-size-fits-all' approach and adaptability is the key to success |
|
Original Research Audit of amylase and lipase requests in suspected acute pancreatitis and cost implications, South Africa Cook, Annie E. Jalavu, Thumeka P. Zemlin, Annalise E. Resumen en Inglés: BACKGROUND: The internationally accepted criteria for the diagnosis of acute pancreatitis (AP) requires two of the three following features to be present: characteristic abdominal pain, elevated serum amylase and/or lipase enzymes, or consistent imaging results. However, sensitivity and specificity can vary depending on the population and cut-off values used OBJECTIVE: This study evaluated the suitability of amylase and lipase as first-line diagnostic biomarkers of suspected AP for the local population served by Tygerberg Hospital, South Africa METHODS: This retrospective analysis was conducted in June 2019 using all amylase and/or lipase request data from December 2018. Patient clinical data were included in sensitivity and specificity analyses of amylase, lipase or dual requests for diagnosis of AP. Cost per test data were obtained from the National Health Laboratory Service and used to calculate the total cost of the tests and potential savings RESULTS: Sensitivity for lipase was 90.0% compared to 50.0% for amylase. Specificity was similar for singular measurements of lipase and amylase. Dual measurement of amylase and lipase showed no improvement in sensitivity (83.3%) and only a minor increase in specificity (97.4%) compared with measurement of lipase alone. The estimated savings was R2522.85 ($174.98 USD), with a potential annual cost saving of R84 423.74 ($5855.69 USD CONCLUSION: Lipase was shown to be a more sensitive biomarker compared to amylase for the screening of AP, providing evidence for laboratories to educate local staff and promote improved requesting practices by clinicians. Additionally, preventing unnecessary dual requests may reduce costs |
|
Original Research The Togo national proficiency test pilot programme for basic clinical chemistry tests Kouassi, Kafui C. Dorkenoo, Améyo M. Gbada, Komivi Afanyibo, Yaovi-Gameli Têko, Minogblon Koura, Adjane Resumen en Inglés: BACKGROUND: A national proficiency test (PT) programme is not currently implemented in most low-income countries. However, participation in such PT programmes assists improves test performance and result accuracy OBJECTIVE: This study assessed how well 11 government hospital laboratories performed 18 basic clinical chemistry tests and identified areas needing improvement METHODS: A cross-sectional study was carried out by the Division of Laboratories of the Ministry of Health of Togo from 01 July 2016 to 31 December 2016. The test performance was evaluated using panels provided by One World Accuracy, Canada (Vancouver). The Clinical Laboratory Improvement Amendments criteria were used in evaluating the laboratories, and their success rates were compared with the World Health Organization Regional Office for Africa's target of 80% RESULTS: The overall rate of acceptable results at the laboratories was over 80% for glucose, alanine aminotransferase, aspartate aminotransferase, gamma-glutamyltransferase, alkaline phosphatase and triglycerides tests. The laboratories using fully automated spectrophotometers had an acceptable results rate of 89% (p = 0.001). The overall performance of the laboratories by cycles varied from 71% to 82% CONCLUSION: This national PT programme identified the tests, which laboratories must improve their performance (urea, creatinine, uric acid, bilirubin, cholesterol, total protein, calcium, magnesium, phosphorus). It demonstrated the need for the use of routine appropriate internal quality control in all laboratories. The proficiency test programme should be extended to all clinical laboratories and target all biology disciplines |
|
Original Research Molecular detection of hepatitis B virus genotype E with immune escape mutations in chronic hepatitis B patients on long-term antiviral therapy in Jos, Nigeria Anejo-Okopi, Joseph Okeke, Edith Davwar, Pantong M. Onwuamah, Chika Onywera, Harris Omaiye, Patience Duguru, Mary Okojokwu, Ocheme J. Ujah, Otobo I. Jonathan, Bulus George, Chima A. Crown, Ramyil S. Yakubu, Fiyaktu B. Sokei, Judith O. Okoli, Leona C. Audu, Onyemocho Inzaule, Seth C. Abah, Isaac O. Agaba, Patricia Agbaji, Oche O. Sagay, Atiene S. Hawkins, Claudia Resumen en Inglés: BACKGROUND: Previous studies in Nigeria have reported the presence of hepatitis B virus (HBV) genotype E and the availability of immune escape mutants. There is a paucity of data on chronic patients on long-term antiviral therapy for HBV infection OBJECTIVE: This study assessed HBV genotypes and drug resistance variants among patients with chronic HBV infection receiving tenofovir in Jos, Nigeria METHODS: This cross-sectional study consecutively enrolled 101 patients (51 with HIV/HBV co-infection and 50 with HBV infection only) on antiviral therapy from February 2018 to May 2019 at four hospitals in Jos, Nigeria. DNA quantification of HBV was performed on all samples; 30 samples with detectable viral load were selected for genotyping using Sanger sequencing by targeting the full-length sequences of reverse transcriptase gene of the HBV genome. Phylogenetic analysis was performed with reference sequences from GenBank. Escape mutant and drug resistance analysis were performed using HBV drug resistance interpretation and Geno2pheno RESULTS: Only 30 (29.7%) of the 101 study participants had detectable HBV DNA. Of these, six (20.0%) isolates were successfully amplified and sequenced. The identified genotype was E, including escape mutations L127R (16.7%) and G145A (16.7% CONCLUSION: This study revealed exclusive dominance of genotype E in Nigeria. The S gene mutations G145A and L271R are known to be associated with modified antigenicity and impaired serologic assays, which may cause false negatives in the detection of anti-HBV surface antigen. The presence of mutants that are associated with vaccine immune escape may also have diagnostic and vaccine immune response implications |
|
Review Article Low-level viraemia: An emerging concern among people living with HIV in Uganda and across sub-Saharan Africa Nanyeenya, Nicholus Kiwanuka, Noah Nakanjako, Damalie Nakigozi, Gertrude Kibira, Simon P.S. Nabadda, Susan Kiyaga, Charles Sewanyana, Isaac Nasuuna, Esther Makumbi, Fredrick Resumen en Inglés: Attaining viral load (VL) suppression for over 95% of the people living with HIV on antiretroviral therapy is a fundamental step in enabling Uganda and other sub-Saharan African countries to achieve global Sustainable Development Goal targets to end the HIV/AIDS epidemic by 2030. In line with the 2013 World Health Organization recommendations, several sub-Saharan African countries, including Uganda, use a threshold of 1000 HIV viral RNA copies/mL to determine HIV viral non-suppression. The United States Centers for Disease Control and Prevention and the International Association of Providers of AIDS Care deem this threshold very high, and hence recommend using 200 copies/mL to determine viral non-suppression. Using 1000 copies/mL as a threshold ignores people living with HIV who have low-level viraemia (LLV; HIV VL of at least 50 copies/mL but less than 1000 copies/mL). Despite the 2021 World Health Organization recommendations of using intensive adherence counselling for people living with HIV with LLV, several sub-Saharan African countries have no interventions to address LLV. However, recent studies have associated LLV with increased risks of HIV drug resistance, virologic failure and transmission. The purpose of this narrative review is to provide insights on the emerging concern of LLV among people living with HIV receiving antiretroviral therapy in sub-Saharan Africa. The review also provides guidance for Uganda and other sub-Saharan African countries to implement immediate appropriate interventions like intensive adherence counselling, reducing VL thresholds for non-suppression and conducting more research to manage LLV which threatens progress towards ending HIV by 2030. |
|
Original Research Impact of rapid centrifugation on routine coagulation assays in South Africa Haripersadh, Reola Pillay, Dashini Rapiti, Nadine Resumen en Inglés: BACKGROUND: The recommendation for coagulation blood samples is to centrifuge at 4000 revolutions per minute (rpm) for 15 min to produce platelet-poor plasma before analysis. Rapid centrifugation, defined as centrifuging samples at higher speeds for shorter durations, could potentially reduce turn-around times (TAT), provided sample integrity is maintained. OBJECTIVE: This study assessed the impact of rapid centrifugation on routine coagulation assay results. METHODS: Blood samples were collected from volunteers at Inkosi Albert Luthuli Central Hospital and King Edward VIII Hospital, Durban, KwaZulu-Natal, South Africa, from September to November 2021. Samples were centrifuged using Method A, the current standard (4000 rpm/15 min), Method B (4000 rpm/10 min), Method C (5000 rpm/10 min) and Method D (5000 rpm/5 min). Platelet count, prothrombin time, activated partial thromboplastin time, thrombin time (TT), fibrinogen and D-dimer levels were analysed and results from Methods B, C and D compared to reference Method A. RESULTS: Platelet-poor plasma was obtained from all samples (n = 60) using Methods A and B, and from 33/60 (55%) samples using Methods C and D. Differences between Method A and Methods C and D for normal prothrombin time, normal D-dimer and abnormal TT results were statistically significant. Prothrombin time results correlated strongly across all methods, while TT and D-dimer results correlated poorly. Activated partial thromboplastin time and fibrinogen results showed no significant differences across all methods. CONCLUSION: Rapid centrifugation at 4000 rpm/10 min (Method B) showed results consistent with the reference method. This method could potentially reduce the overall TAT for routine coagulation assays. |
|
Original Research South African study of blast phase chronic myeloid leukaemia: A poor prognostic outlook Hodkinson, Katherine E. Bouwer, Nikki Vaughan, Jenifer Resumen en Inglés: BACKGROUND: Chronic myeloid leukaemia (CML) is a haematological malignancy characterised by the translocation t(9;22)(q34;q11.2), resulting in a constitutively active tyrosine kinase. Globally, overall survival of blast crisis phase (BC) CML is one year. Newer tyrosine kinase inhibitors and allogeneic stem cell transplantation offer remission; however, refractory and relapsed disease remain the biggest challenges. OBJECTIVE: In South Africa, literature is lacking on BC-CML. This study aimed to determine the disease characteristics and overall survival in South Africa. METHODS: This retrospective, laboratory-based study reviewed all new BC-CML diagnoses via flow cytometry at Charlotte Maxeke Johannesburg Academic Hospital in Johannesburg, South Africa, between April 2016 and October 2019. BC-CML was defined as the presence of > 20% blasts with a CML history or the BCR-ABL1 fusion gene (p210/p190) in the appropriate clinical or pathological context. Survival outcomes were inferred from clinical and laboratory data. RESULTS: Twenty-two new cases of BC-CML were diagnosed (median age: 34 years). There were 20 (91%) cases with the fusion transcripts p210 and two (9%) cases with p190 BCRABL1. For blast lineage, 14 cases were myeloid (63.6%), six were lymphoid (27.3%), and two were ambiguous (9.1%). There was a 72.7% mortality (16 cases); sepsis, refractory and relapsed disease were the major causes. Patients who achieved remission had lower blast percentages, simple karyotypes, and a trend towards higher white cell and platelet counts at presentation. CONCLUSION: Optimised management of early-stage CML, prevention and aggressive management of sepsis, with advocation for newer therapies are needed to improve the overall survival of BC-CML in South Africa |
|
Original Research Red blood cell alloimmunisation in multi-transfused patients from an haemodialysis service in Burkina Faso Nebie, Koumpingnin Sawadogo, Salam Sawadogo, Salifo Koulidiati, Jérôme Lengani, Habi Y.A. Sawadogo, Abdoul G. Babinet, Jérôme Khalloufi, Mohammed Diop, Saliou Kafando, Eléonore Resumen en Inglés: BACKGROUND: In Burkina Faso, red blood cell (RBC) transfusion remains the crucial anaemia treatment following chronic renal failure (CRF) as erythropoietin and its analogues are unavailable. However, blood group matching beyond the ABO and Rhesus is not common in Burkina Faso. Thus, alloimmunisation is a potential issue for transfused patients OBJECTIVE: Our study aimed to identify anti-erythrocyte antibodies in multi-transfused CRF patients at the Yalgado Ouedraogo Teaching Hospital, Ouagadougou, Burkina Faso METHODS: This cross-sectional study, conducted from October 2018 to November 2019, included CRF patients who had received at least two RBC units. We screened patients for the presence of RBC antibodies using three commercial Cells panels and identified antibody specificities for positive screenings using 11 Cells panels for an indirect antiglobulin test (IAT) in a low ionic strength microcolumn gel-card system RESULTS: Two hundred and thirty-five patients (45.1% female; average age: 41.5 years) were included. The median number of blood units received per patient was 10 (interquartile range: 5-20). The overall alloimmunisation rate was 5.9% (14/235). Antibodies identified included: anti-D (1 case), anti-C (1 case), anti-D+C (4 cases), anti-CW (1 case), anti-E (1 case), anti-S (1 case) and anti-Lea (1 case). In four positive patients, the specificity of the antibodies was indeterminate. No risk factors were associated with alloimmunisation CONCLUSION: In Burkina Faso, screening for RBC alloantibodies should be mandated for patients at risk. The high rate of indeterminate antibodies suggests the need to develop a local RBC antibody panel adapted to the local population |
|
Original Research Evaluation of fixed-panel, multicolour ClearLLab 10C at an academic flow cytometry laboratory in Johannesburg, South Africa Glencross, Deborah K. Swart, Leanne Pretorius, Melanie Lawrie, Denise Resumen en Inglés: BACKGROUND: Flow cytometric immunophenotyping is well established for the diagnosis of haematological neoplasms. New commercially available systems offer fixed, pre-aliquoted multi-parameter analysis to simplify sample preparation and standardise data analysis OBJECTIVE: The Beckman Coulter (BC) ClearLLab™ 10C (4-tube) system was evaluated against an existing laboratory developed test (LDT). METHODS: Peripheral blood and bone marrow aspirates (n = 101), tested between August 2019 and November 2019 at an academic pathology laboratory in Johannesburg, South Africa, were analysed. Following daily instrument quality control, samples were prepared for LDT (using > 20 2-4-colour in-house panels and an extensive liquid monoclonal reagent repertoire) or ClearLLab 10C, and respectively analysed using in-house protocols on a Becton Dickinson FACSCalibur, or manufacturer-directed protocols on a BC Navios. Becton Dickinson Paint-a-Gate or BC Kaluza C software facilitated data interpretation. Diagnostic accuracy (concordance) was established by calculating sensitivity and specificity outcomes RESULTS: Excellent agreement (clinical diagnostic concordance) with 100% specificity and sensitivity was established between LDT and ClearLLab 10C in 67 patients with a haematological neoplasm and 34 participants with no haematological disease. Similar acceptable diagnostic concordance (97%) was noted when comparing ClearLLab 10C to clinicopathological outcomes. Additionally, the ClearLLab 10C panels, analysed with Kaluza C software, enabled simultaneous discrimination of disease and concurrent background myeloid and lymphoid haematological populations, including assessing stages of maturation or sub-populations CONCLUSION: ClearLLab 10C panels provide excellent agreement to existing LDTs and may reliably be used for immunophenotyping of haematological neoplasms, simplifying and standardising sample preparation and data acquisition |
|
Original Research Enhancing accreditation outcomes for medical laboratories on the Strengthening Laboratory Management Toward Accreditation programme in Kenya via a rapid results initiative Makokha, Ernest P. Ondondo, Raphael O. Kimani, Daniel K. Gachuki, Thomas Basiye, Frank Njeru, Mercy Junghae, Muthoni Downer, Marie Umuro, Mamo Mburu, Margaret Mwangi, Jane Resumen en Inglés: BACKGROUND: Since 2010, Kenya has used SLIPTA to prepare and improve quality management systems in medical laboratories to achieve ISO 15189 accreditation. However, less than 10% of enrolled laboratories had done so in the initial seven years of SLMTA implementation OBJECTIVE: We described Kenya's experience in accelerating medical laboratories on SLMTA to attain ISO 15189 accreditation METHODS: From March 2017 to July 2017, an aggressive top-down approach through high-level management stakeholder engagement for buy-in, needs-based expedited SLIPTA mentorship and on-site support as a rapid results initiative (RRI) was implemented in 39 laboratories whose quality improvement process had stagnated for 2-7 years. In July 2017, SLIPTA baseline and exit audit average scores on quality essential elements were compared to assess performance RESULTS: After RRI, laboratories achieving greater than a 2-star SLMTA rating increased significantly from 15 (38%) at baseline to 33 (85%) (p < 0.001). Overall, 34/39 (87%) laboratories received ISO 15189 accreditation within two years of RRI, leading to a 330% increase in the number of accredited laboratories in Kenya. The most improved of the 12 quality system essentials were Equipment Management (mean increase 95% CI: 5.31 ± 1.89) and Facilities and Biosafety (mean increase [95% CI: 4.05 ± 1.78]) (both: p < 0.0001). Information Management and Corrective Action Management remained the most challenging to improve, despite RRI interventions CONCLUSION: High-level advocacy and targeted mentorship through RRI dramatically improved laboratory accreditation in Kenya. Similar approaches of strengthening SLIPTA implementation could improve SLMTA outcomes in other countries with similar challenges |
|
Original Research Formulation of phage cocktails and evaluation of their interaction with antibiotics in inhibiting carbapenemase-producing Klebsiella pneumoniae in vitro in Kenya Michodigni, Noutin F. Nyachieo, Atunga Akhwale, Juliah K. Magoma, Gabriel Ouédraogo, Abdoul-Salam Kimang'a, Andrew N. Resumen en Inglés: BACKGROUND: The development of alternative control measures, such as phage therapy or adjunctive therapy, is urgently needed to manage the dissemination of carbapenemase-producing Klebsiella pneumoniae. OBJECTIVE: This study aimed to evaluate the therapeutic potential of formulated phage cocktails and their interaction with select antibiotics in inhibiting the growth of carbapenemase-producing K. pneumoniae clinical isolate in vitro in Kenya. METHODS: The study was conducted from February 2021 to October 2021 at the Institute of Primate Research, Nairobi, Kenya. Phage cocktails were formulated based on the morphology and biological properties of precipitated Klebsiella phages. The efficacy of individual bacteriophages and phage cocktails as well as their combination with antibiotics were determined for their inhibitory activity on carbapenemase-producing K. pneumoniae (KP20). RESULTS: The precipitated bacteriophages were members of Myoviridae, Siphoviridae and Podoviridae. Regarding the evaluation of the phage cocktails, the absorbances at 600 nm of the bacterial culture treated with the two-phage cocktail (2φ MA) ranged from 0.173 to 0.246 at 16 h and 20 h whereas it peaked from 2.116 to 2.190 for the positive control. Moreover, the results of the adjunctive therapy showed that the optical density at 600 nm of the bacterial culture treated with 2φ MA was 0.186 at 24 h post-incubation time while it was 0.099 with the bacterial culture treated with imipenem in combination with 2φ MA. CONCLUSION: This study demonstrated that the two-phage cocktail in combination with imipenem was able to synergistically delay the increase in carbapenemase-producing K. pneumoniae growth in vitro. |
|
Original Research Human herpes virus type-6 is associated with central nervous system infections in children in Sudan Abdelrahim, Nada A. Mohamed, Nahla Evander, Magnus Ahlm, Clas Fadl-Elmula, Imad M. Resumen en Inglés: BACKGROUND: Human herpes virus type-6 (HHV-6) is increasingly recognised as a febrile agent in children. However, less is known in sub-Saharan African countries, including Sudan. OBJECTIVE: We investigated the involvement of HHV-6 in paediatric central nervous system (CNS) infections in Khartoum, Sudan. METHODS: Febrile patients aged up to 15 years with suspected CNS infections at Omdurman Hospital for Children from 01 December 2009 to 01 August 2010 were included. Viral DNA was extracted from leftover cerebrospinal fluid (CSF) specimens and quantitatively amplified by real-time polymerase chain reaction (PCR) at Umeå University in Sweden. RESULTS: Of 503 CSF specimens, 13 (2.6%) were positive for HHV-6 (33.0% [13/40 of cases with proven infectious meningitis]). The median thermal cycle threshold for all HHV-6-positive specimens was 38 (range: 31.9-40.8). The median number of virus copies was 281.3/PCR run (1 × 105 copies/mL CSF; range: 30-44 × 103 copies/PCR run [12 × 103 - 18 × 106 copies/mL CSF]). All positive patients presented with fever and vomiting; 86.0% had seizures. The male-to-female ratio was 1:1; 50.0% were toddlers, 42.0% infants and 8.0% teenagers. Most (83.0%) were admitted in the dry season and 17.0% in the rainy season. Cerebrospinal fluid leukocytosis was seen in 33.0%, CSF glucose levels were normal in 86.0% and low in 14.0%, and CSF protein levels were low in 14.0% and high in 43.0%. CONCLUSION: Among children in Sudan with CNS infections, HHV-6 is common. Studies on the existence and spread of HHV-6 chromosomal integration in this population are needed. |
|
Original Research Malaria an opportunistic infection in HIV/AIDS patients? - A Nigerian experience Enuma, Joseph N. Sanni, Felix O. Matur, Malau B. Jean, Njab E. Erhabor, Tosan Egbulefu, Iheukwumere I. Resumen en Inglés: BACKGROUND: HIV and malaria interact at the level of the host's susceptibility to infection, but little is known about the effect of HIV on malaria infection in Nigeria. OBJECTIVE: This study estimated the prevalence of malaria parasitaemia and its relationship with HIV immunodeficiency. METHODS: This cross-sectional study was conducted in two hospitals in Abuja, Nigeria between October 2012 and March 2013 among 600 respondents, comprising 200 HIV-negative controls, 200 HIV-positive patients on antiretroviral therapy (ART), and 200 HIV-positive patients not on ART. Malaria parasites, malaria density and absolute CD4 counts were carried out on all three groups. Participants with CD4 counts below 350 cells/mm3 were considered immunocompromised and likely to develop opportunistic infections. RESULTS: Most study participants were aged 21-40 years (65.2%). The mean CD4 counts of HIV-positive patients not on ART (300 ± 211 cells/mm3) and those on ART (354 cells/mm3) were significantly lower than among controls (834 cells/mm3) (p < 0.001). Malaria prevalence was not statistically different between the controls (44.5%), patients on ART (40.5%), and those not on ART (39.5%) (p = 0.562). Compared to 7% immunodeficiency among controls, 56% of patients on ART and 65.5% of those not on ART had a CD4 count < 350 cells/mm3 (p < 0.001). The prevalence of malaria parasitaemia among immunodeficient individuals (42.4%) was similar to prevalence among those with CD4 counts > 350 cells/mm3 (40.8%; p = 0.695). CONCLUSION: These findings suggest that malaria parasitaemia is not an opportunistic infection among HIV-positive individuals in Nigeria. |
|
Original Research Implementing an intensified mentorship approach towards accelerated medical laboratory accreditation in 10 counties in Kenya Musau, Susan K. Mwachari, Christina Kirui, Elvis Muthoni, Junghae Lascko, Taylor Blanco, Natalia Abimiku, Alash'le Koech, Emily Resumen en Inglés: BACKGROUND: Despite Kenya's roll-out of the Strengthening Laboratory Management Towards Accreditation programme in 2010, most laboratories had not made significant or tangible improvements towards accreditation by 2016. In April 2016, the University of Maryland, Baltimore enrolled 27 facilities in the standard Strengthening Laboratory Management Towards Accreditation programme. OBJECTIVE: This study aimed to describe and evaluate the implementation of an intensified mentorship strategy on laboratory accreditation METHODS: In October 2017, the University of Maryland, Baltimore implemented intensive mentorship in 27 hospital laboratories in Nairobi, Kiambu, Meru, Embu, Muranga, Nyeri, Laikipia, Nyandarua, Tharaka-Nithi, and Kirinyaga counties in Kenya. Laboratories were paired with competent mentors whose skills were matched to facility gaps. Baseline and follow-up assessments were done between April 2016 and March 2019 using the World Health Organization's Stepwise Laboratory Quality Improvement Process Towards Accreditation Checklist and overall scores of the 12 Quality System Essentials and star ratings (from zero to five, based on scores) used to evaluate the effectiveness of the intensified mentorship. RESULTS: In September 2017, 14 laboratories scored zero stars, three scored one star, eight scored two stars, one scored three stars, and one laboratory was accredited. By March 2019, eight laboratories were accredited, five scored four stars, 10 scored three stars, three scored two stars, and only one scored one star. The average score change with the intensified approach was 81.5 versus 53.9 for the standard approach. CONCLUSION: The intensified mentorship strategy resulted in fast-tracked progress towards laboratory accreditation and can be adopted in similar resource-limited settings. |
|
Lessons from the Field Practical tips to using formalin-fixed paraffin-embedded tissue archives for molecular diagnostics in a South African setting van Deventer, Barbara S. du Toit-Prinsloo, Lorraine van Niekerk, Chantal Resumen en Inglés: BACKGROUND: Formalin-fixed paraffin-embedded (FFPE) tissue archives in hospitals, biobanks, and others offer a vast collection of extensive, readily available specimens for molecular testing. Unfortunately, the use of tissue samples for molecular diagnostic applications is challenging; thus, the forensic pathology FFPE tissue archives in Africa have been a largely unexploited genetic resource, with the usability of DNA obtainable from these samples being unknown. INTERVENTION: The study, conducted from January 2015 to August 2016, determined the usefulness of FFPE tissue as a reliable source of genetic material for successful post-mortem molecular applications and diagnostics. Formalin-fixed paraffin-embedded tissue samples were collected and archived from autopsies conducted over 13 years in the forensic medicine department of the University of Pretoria (Pretoria, South Africa). Deoxyribonucleic acid from FFPE tissue samples and control blood samples was amplified by high-resolution melt real-time polymerase chain reaction before sequencing. The procurement parameters and fixation times were compared with the quantity and quality of the extracted DNA and the efficiency of its subsequent molecular applications. LESSONS LEARNT: This study has shown that FFPE samples are still usable in molecular forensics, despite inadequate sample preparation, and offer immense value to forensic molecular diagnostics. RECOMMENDATIONS: FFPE samples fixed in formalin for more than 24 h should still be used in molecular diagnostics or research, as long as the primer design targets amplicons not exceeding 300 base pairs. |
|
Original Research Delays in HIV-1 infant polymerase chain reaction testing may leave children without confirmed diagnoses in the Western Cape province, South Africa Mahlakwane, Kamela L. Preiser, Wolfgang Nkosi, Nokwazi Naidoo, Nasheen van Zyl, Gert Resumen en Inglés: BACKGROUND: Early diagnosis and confirmation of HIV infection in newborns is crucial for expedited initiation of antiretroviral therapy. Confirmatory testing must be done for all children with a reactive HIV PCR result. There is no comprehensive data on confirmatory testing and HIV PCR test request rejections at National Health Laboratory Service laboratories in South Africa. OBJECTIVE: This study assessed the metrics of routine infant HIV PCR testing at the Tygerberg Hospital Virology Laboratory, Cape Town, Western Cape, South Africa, including the proportion of rejected test requests, turn-around time (TAT), and rate of confirmatory testing METHODS: We retrospectively reviewed laboratory-based data on all HIV PCR tests performed on children ≤ 24 months old (n = 43 346) and data on rejected HIV PCR requests (n = 1479) at the Tygerberg virology laboratory over two years (2017-2019). Data from sample collection to release of results were analysed to assess the TAT and follow-up patterns. RESULTS: The proportion of rejected HIV PCR requests was 3.3%; 83.9% of these were rejected for various pre-analytical reasons. Most of the test results (89.2%) met the required 96-h TAT. Of the reactive initial test results, 53.5% had a follow-up sample tested, of which 93.1% were positive. Of the initial indeterminate results, 74.7% were negative on follow-up testing. CONCLUSION: A high proportion of HIV PCR requests were rejected for pre-analytical reasons. The high number of initial reactive tests without evidence of follow-up suggests that a shorter TAT is required to allow confirmatory testing before children are discharged. |
|
Original Research Childhood aplastic anaemia with paroxysmal nocturnal haemoglobinuria clones: A retrospective single-centre study in South Africa Hendricks, Candice L. Naidoo, Ashen Thejpal, Rajendra Rapiti, Nadine Neethling, Beverley Goga, Yasmin Buldeo, Suvarna Resumen en Inglés: BACKGROUND: Paroxysmal nocturnal haemoglobinuria (PNH) clones in children are rare but commonly associated with aplastic anaemia (AA) and myelodysplasia. OBJECTIVE: This study aimed to determine the prevalence of PNH clones in paediatric patients with idiopathic AA, identify differences in clinical and laboratory features and outcomes, and determine the impact of clone size on clinical presentation METHODS: Patients with confirmed idiopathic AA who were tested for PNH between September 2013 and January 2018 at the Inkosi Albert Luthuli Central Hospital, Durban, KwaZulu-Natal, South Africa, were included. PNH clones were detected in neutrophils and monocytes by flow cytometry using fluorescent aerolysin, CD24, CD66b and CD14. RESULTS: Twenty-nine children with AA were identified and 11 were excluded. Ten patients (10/18, 55.6%) had PNH clones ranging from 0.11% to 24%. Compared to the PNH-negative group, these children were older (median: 10 years vs 4 years, p = 0.02) and had significantly lower total white cell counts (median 1.7 × 109/L vs 3.2 × 109/L; p = 0.04). There was no difference in median absolute neutrophil count or haemoglobin concentration. Four patients in each group received immunosuppressive therapy (IST). At six months, all four patients with PNH clones had responded, compared to one in the PNH-negative group. CONCLUSION: More than half of children with AA had a PNH clone. The size of the clone did not impact clinical severity; however, IST use may positively impact prognosis. We recommend early initiation of IST in patients with AA to avoid delays associated with human leukocyte antigen typing. |
|
Original Research Oral human papilloma virus infection among dental clinic attendees in Ibadan, Nigeria Faneye, Adedayo O. Babalola, Oyeteju S. Odaibo, Georgina N. Arotiba, Juwon Olaleye, Olufemi D. Resumen en Inglés: BACKGROUND: Human papilloma virus (HPV) is associated with a subset of oropharyngeal squamous cell carcinoma and mouth or throat warts. However, there is currently limited information about oral HPV infections in Nigeria. OBJECTIVE: This study aimed to provide information on the occurrence and circulating genotypes of HPV among patients attending three (one government and two private) dental clinics in Ibadan, Nigeria. METHODS: An oral swab was collected from 231 dental clinic attendees in Ibadan between January 2016 and March 2017 and tested for HPV DNA by polymerase chain reaction targeting the E6/7 genes of the virus. RESULTS: Twenty-three of the 231 swab samples were HPV DNA positive comprising 16 mono-infections and seven co-infections in 13 males and ten females. Genotype 16 was present in ten patients, genotype 6/11 in five, Genotype 18 and genotype 33 in four each, genotype 31 in three and genotype 39 in one. Twenty-one cases were high-risk HPV genotypes, while two were low-risk. Samples had co-infection and five had low risk type 6/11 either as single or as co-infection. Persons who had engaged in oral sex as well as those aged 21-30 years has significantly higher prevalence. CONCLUSION: This study showed that although HPV genotype 16 is the most common type among dental clinic attendees in Ibadan, other genotypes are also circulating and that oral sex is a risk factor for the infection. Therefore, introducing a multivalent HPV vaccine will reduce the risk of HPV-associated oropharyngeal carcinoma and other cancers in Nigeria. |
|
Opinion Papers To break the cycle of COVID-19 lockdowns and safely open up economies, we must ensure equitable access to diagnosis and treatment Ndlovu, Nqobile Tebeje, Yenew K. Gadde, Renuka Peter, Trevor |
|
Corrections Corrigendum: Higher proportion of non-classical and intermediate monocytes in newly diagnosed multiple myeloma patients in Egypt: A possible prognostic marker Zahran, Asmaa M. Nafady-Hego, Hanaa Moeen, Sawsan M. Eltyb, Hanan A. Wahman, Mohammed M. Nafady, Asmaa |
|
Original Research Therapeutic drug monitoring of phenytoin and valproic acid in critically ill patients at Windhoek Central Hospital, Namibia Singu, Bonifasius S. Morrison, Helen Irengeya, Lydia Verbeeck, Roger K. Resumen en Inglés: BACKGROUND: Phenytoin and valproic acid, anticonvulsants, have a low therapeutic index and are highly plasma protein bound, mainly to albumin. Hypoalbuminaemia is common in critically ill patients and increases the unbound drug concentration. Thus, monitoring unbound rather than total plasma drug concentrations is recommended to optimise the dosing of these drugs OBJECTIVE: This retrospective study determined unbound plasma concentrations of phenytoin and valproic as a more accurate value of drug levels than total plasma drug concentrations METHODS: Total plasma concentrations were retrieved for 56 Intensive Care Unit patients for phenytoin and 93 for valproic acid. Total drug concentrations were converted to unbound concentrations using a serum albumin-based normalising equation RESULTS: Total phenytoin plasma concentration was below (41.1% of patients), within (46.4%) or above (12.5%) the therapeutic range (10 μg/mL - 20 μg/mL). However, the predicted unbound plasma concentration of phenytoin was above the therapeutic range (1 μg/mL - 2 μg/mL) in the majority of patients (57.1%). For valproic acid, the total plasma concentration of most patients (87.1%) was below the therapeutic range (50 μg/mL - 100 μg/mL); among remaining patients (12.9%), it was within the therapeutic range. In the majority of patients (91.4%), the predicted unbound plasma concentration of valproic acid was between 2.5 μg/mL and 20 μg/mL CONCLUSION: The usefulness of monitoring the total phenytoin or valproic acid levels for dose optimisation is limited as it is an inaccurate indicator of a patient's drug therapeutic state. Thus, the unbound plasma drug concentrations should be quantified experimentally or predicted in resource-limited settings |
|
Review Article Microbiology laboratories involved in disease and antimicrobial resistance surveillance: Strengths and challenges of the central African states Vounba, Passoret Loul, Severin Tamadea, Ludovic F. Siawaya, Joël F.D. Resumen en Inglés: Laboratory systems have been largely neglected on the margins of health systems in Africa. However, since the 2000s, many African countries have benefited from massive investments to strengthen laboratory capacities through projects fighting priority diseases (HIV/AIDS, tuberculosis, malaria). This review examined the laboratory capacities of the Economic Community of Central African States (ECCAS). Online research using specific terms was carried out. Studies published between 2000 and 2021 on the role of the laboratory in disease and antimicrobial resistance surveillance in the 11 ECCAS countries were considered. The number of human and animal health laboratories meeting international standards was very low in the sub-region. There were only seven International Organization for Standardization (ISO) 15189-accredited human health laboratories, with five in Cameroon and two in Rwanda. There were five high biosafety level (BSL) laboratories (one BSL3 laboratory each in Cameroon, the Central African Republic, Democratic Republic of Congo and the Republic of Congo, and one BSL4 laboratory in Gabon) and three ISO 17025-accredited laboratories in the ECCAS sub-region. Only six countries currently have whole-genome sequencing devices, which is insufficient for a sub-region as large and populous as ECCAS. Yet, a plethora of pathogens, particularly haemorrhagic viruses, are endemic in these countries. The need for laboratory capacity strengthening following a One Health approach is imperative. Since emerging and re-emerging zoonotic infectious diseases are projected to triple in frequency over the next 50 years and given the inextricable link between human and animal health, actors in the two health sectors must collaborate to preserve world health. |
|
Review Article Beta-lactamase resistance genes in Enterobacteriaceae from Nigeria Awosile, Babafela B. Agbaje, Michael Adebowale, Oluwawemimo Kehinde, Olugbenga Omoshaba, Ezekiel Resumen en Inglés: BACKGROUND: Beta-lactamase genes are one of the most important groups of antimicrobial resistance genes in human and animal health. Therefore, continuous surveillance of this group of resistance genes is needed for a better understanding of the local epidemiology within a country and global disseminationAIM: This review was carried out to identify different beta-lactamase resistance genes reported in published literature from NigeriaMETHODS: Systematic review and meta-analysis was carried out on eligible Nigerian articles retrieved from electronic literature searches of PubMed®, African Journals Online, and Google Scholar published between January 1990 and December 2019. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses method was adopted to facilitate clarity and transparency in reporting review findingsRESULTS: Fifty-seven articles were included. All beta-lactamases reported were detected from Gram-negative bacteria, particularly from Enterobacteriaceae. Thirty-six different beta-lactamase genes were reported in Nigeria. These genes belong to the narrow-spectrum, AmpC, extended-spectrum and carbapenemase beta-lactamase resistance genes. The pooled proportion estimate of extended-spectrum beta-lactamase genes in Nigeria was 31% (95% confidence interval [CI]: 26% - 36%, p < 0.0001), while the estimate of the blaCTX-M-15 gene in Nigeria was 46% (95% CI: 36% - 57%, p < 0.0001). The proportion estimate of AmpC genes was 32% (95% CI: 11% - 52%, p < 0.001), while the estimate for carbapenemases was 8% (95% CI: 5% - 12%, p < 0.001CONCLUSION: This study provides information on beta-lactamase distribution in Nigeria. This is necessary for a better understanding of molecular epidemiology of clinically important beta-lactamases, especially the extended-spectrum beta-lactamases and carbapenemases in Nigeria |
|
Brief Report Retrospective analysis of Vitek®2 performance compared to manual broth micro-dilution for colistin susceptibility testing of Acinetobacter baumanniicomplex isolates in South Africa Fadana, Vuyolwethu Thomas, Teena von Knorring, Nina Resumen en Inglés: The manual broth micro-dilution (mBMD) is the recommended reference method for colistin minimum inhibitory concentration determination; however, it is not as readily available in South Africa as the Vitek®2. This retrospective study compared the performance of Vitek®2 against mBMD in determining the colistin minimum inhibitory concentration of 337 extensively drug-resistant Acinetobacter baumannii complex isolates. Vitek®2 yielded a categorical agreement of 89%, an essential agreement of 56%, a major error rate of 8% and a very major error rate of 55%. The Vitek®2 is not an alternative to mBMD for colistin susceptibility testing. |
|
Original Research Prevalence of hepatitis B virus core antibodies among blood donors in Nigeria: Implications for blood safety Fasola, Foluke A. Fowotade, Adeola A. Faneye, Adedayo O. Adeleke, Adeyeni Resumen en Inglés: BACKGROUND: Anti-hepatitis B core antibody (anti-HBc) testing improves transfusion safety by detecting past and current hepatitis B virus (HBV) infection while detecting hepatitis B surface antigen (HBsAg) in serology-negative HBV infection. However, occult HBV infection (OBI) (serum or liver HBV DNA-positive but HBsAg-negative) remains unaddressed among replacement blood donors - family members or friends who donate to replace blood transfused to a relative. OBJECTIVE: This study assessed risk factors for a positive anti-HBc test among donors with OBI and determined the anti-HBc-positive status of replacement donors. METHODS: The study was conducted at the University College Hospital Blood Bank, Ibadan, Nigeria, using blood samples collected from blood donors between April 2019 and May 2019. Donors were screened for HBsAg by rapid diagnostic test (RDT) and enzyme-linked immunosorbent assay (ELISA) and anti-HBc by ELISA, while HBV DNA was detected using a semi-nested polymerase chain reaction. RESULTS: Of the 274 participants, 15 (5.5%) were HBsAg-positive by RDT and 36 (13.1%) by ELISA, while 133 (48.5%) were anti-HBc positive. Out of 232 HBsAg-negative donors, 107 (46.1%) were anti-HBc positive. Of the 107 HBsAg-negative but anti-HBc-positive samples, only one (0.93%) was HBV DNA-positive. The HBV DNA-positive donor was HBsAg-negative by both RDT and ELISA tests. CONCLUSION: This study establishes a potential risk for HBV transmission from isolated anti-HBc-positive donors to blood recipients. HBc immunoglobulin (antibody) M testing to identify blood units requiring further screening with polymerase chain reaction to detect OBI can prevent HBV transmission through blood transfusion. |
|
Original Research High-risk human papillomavirus-associated vulvar neoplasia among women living with human immunodeficiency virus in Zambia Maate, Fred Julius, Peter Siyumbwa, Stepfanie Pinder, Leeya Kaile, Trevor Mwanahamuntu, Mulindi Parham, Groesbeck Resumen en Inglés: BACKGROUND: Globally, women living with HIV have a higher risk of vulvar neoplasia than HIV-negative women. Vulvar neoplasia among women living with HIV has not previously been characterised in Zambia OBJECTIVE: This study determined the clinical and pathologic features of vulvar neoplasia among women living with HIV at the University Teaching Hospital, Lusaka, Zambia METHODS: We conducted a cross-sectional study of vulvar lesions among 53 women living with HIV who presented with vulvar lesions between July 2017 and February 2018. The study assessed clinical and histological characteristics and prevalence of high-risk human papillomavirus (HRHPV RESULTS: Twenty-one patients were diagnosed with vulvar squamous cell carcinoma (VSCC), 20 with usual vulvar intraepithelial neoplasm (uVIN), and the rest with either benign lesions or non-neoplastic lesions (NNL). Participants' mean age was 40 years. Patients with VSCC were significantly older than those with NNL (mean (s.d.): 43 (21) vs 33 (10), p = 0.004). The prevalence of HRHPV was 88.9% in VSCC patients and 100.0% in high-grade squamous intraepithelial lesion patients. HPV16 was the most common (52.6%) genotype. The clinical features of neoplasia were similar to those of NNL CONCLUSION: VSCC was significantly more common among women aged ≥ 40 years. HRHPV in VSCC and high-grade squamous intraepithelial lesions was high. Women with vulvar lesions, especially those aged > 40 years, should be evaluated for vulvar cancer. Young girls should be vaccinated to prevent vulvar cancer |
|
Original Research Red cell distribution width as a surrogate marker of haemoglobinopathies in western Kenya Mutua, Benard M. Sowayi, George Okoth, Patrick Resumen en Inglés: BACKGROUND: Haemoglobinopathies are inherited haemoglobin disorders that result in anaemia characterised by erythrocyte anisopoikilocytosis. Red cell distribution width (RDW) measures anisopoikiloytosis and is readily reported by haematology analysers as a complete blood count parameter. The utility of RDW as a diagnostic marker of haemoglobinopathies in Kenya remains undetermined and undocumented. OBJECTIVE: This study aimed to determine the diagnostic efficacy of RDW in discriminating haemoglobinopathy and haemoglobinopathy-free cases in Kenya. METHODS: The case-control study used randomly selected haematology analyser outputs for haemoglobinopathy-free (241, 49.4%) and haemoglobinopathy cases (247, 50.1%) aged 1 month to 66 years old tested in the Aga Khan Hospital, Kisumu, and its satellite centres in western Kenya from 01 January 2015 to 31 December 2020. Results were verified using high performance liquid chromatography. The receiver operating characteristic (ROC) curve was used to evaluate the diagnostic power of RDW as a biomarker for sickle cell disease (SCD) and sickle cell trait phenotypes and β-thalassaemia. RESULTS: The RDW showed diagnostic significance in SCD phenotypes at 21.1 ROC curve coordinate with 67.7% sensitivity, 90.0% specificity, 0.789 accuracy, 70.5% positive predictive validity, 88.8% negative predictive validity, 6.77 positive likelihood ratio, 0.36 negative likelihood ratio and 18.94 (11.4-31.4) odds ratio. CONCLUSION: An RDW of 21.1% is potentially a predictor of SCD haemoglobin phenotypes and should be included in the haematology screening algorithm as a critical value, above which suspected cases qualify to be investigated for SCD. |
|
Case Study Extranodal presentation of a lymphoma with precursor B-cell phenotype and translocation t(8;14) in South Africa Hodkinson, Katherine E. Perner, Yvonne Glencross, Deborah K. Wiggill, Tracey Botha, Adam Poole, Janet Resumen en Inglés: INTRODUCTION: A rare entity of a B-cell malignancy with precursor B-cell phenotype and concomitant translocation t(8;14) or variant MYC translocation exists. These cases show clinical, pathological and molecular overlap between precursor B-lymphoblastic leukaemia or lymphoma and Burkitt leukaemia or lymphoma (BLLCASE PRESENTATION: We report a case from February 2019 at the Charlotte Maxeke Johannesburg Academic Hospital, South Africa, of a 9-month-old infant with a predominantly extracranial soft tissue mass showing extradural extension. There was no involvement of the peripheral blood or bone marrow. Fine needle aspiration and Tru-Cut biopsy of the soft tissue scalp mass showed the tumour to be of precursor B-cell phenotype. Contrastingly, an immunophenotypic assessment revealed a high S-phase fraction and raised concern for BLL. This prompted testing for the translocation t(8;14) by fluorescence in-situ hybridisation analysis, which confirmed this aberrationMANAGEMENT AND OUTCOME: Based on the published experience of other centres, the patient was initiated on a BLL protocol. Despite an excellent clinical response, the patient succumbed to neutropenic sepsis six months after diagnosis.CONCLUSION: Leukaemia or lymphoma with translocation t(8;14) or variant MYC translocation and precursor B-cell phenotype is a rare entity with a varied clinical presentation. This poses a challenge for diagnosis and classification and a clinical dilemma for the choice of treatment |
|
Original Research Impact of pre-COVID-19 epidemic preparedness on the trajectory of the pandemic in African countries Maruta, Talkmore Moyo, Sikhulile Resumen en Inglés: BACKGROUND: The novel coronavirus disease 2019 (COVID-19), declared a pandemic by the World Health Organization (WHO) in March 2020, has taught us about the importance of epidemic preparedness. OBJECTIVE: We analysed the pre-COVID-19 preparedness of sub-Saharan African countries and how this may have influenced the trajectory of COVID-19 cases. METHODS: The WHO Joint External Evaluation (JEE) tool and the Global Health Security (GHS) Index were used to determine the epidemic preparedness of countries in the WHO African Region. The relationship between pre-COVID-19 preparedness and the reported number of cases per million people was evaluated over the first 120 days of the first reported case in each country, between February 2020 and September 2020. RESULTS: The overall performance of the 42 countries was 40% in the 19 JEE core capacities and 32% in the six GHS Index indicators. At Day 1, the mean number of cases per million population was significantly higher among countries rated as 'prepared' in the JEE legislation, policy and finance (p = 0.03), ports of entry (p = 0.001), and international health regulation coordination, communication and advocacy (p = 0.03) categories. At Day 90, countries rated as 'prepared' in the national laboratory systems (p = 0.05) and real-time surveillance (p = 0.04) JEE categories had statistically significantly fewer cases per million population. CONCLUSION: This analysis highlights the importance of building capacity for pandemic preparedness in Africa. The WHO African Region was not adequately prepared for the COVID-19 pandemic as measured by the WHO JEE tool and the GHS Index. |
|
Lessons from the Field Strengthening laboratory networks in the Central Africa region: A milestone for epidemic preparedness and response Njukeng, Patrick A. Njumkeng, Charles Ntongowa, Callistus Abdulaziz, Mohammed Resumen en Inglés: BACKGROUND: Health systems in the Central Africa region are among the weakest and least funded in the world. The lack of laboratory networks and adequately trained personnel with clearly defined responsibilities has hampered the implementation of laboratory quality improvement programmes. Global Health Systems Solutions (GHSS) obtained a grant from the Africa Centres for Disease Control and Prevention to develop laboratory networks for disease surveillance and strengthen the quality of laboratory testing in the Central Africa region. INTERVENTION: One year after the grant was awarded on 01 October 2018, GHSS has launched a Regional Integrated Surveillance and Laboratory Network (RISLNET) for Central Africa and developed National Laboratory Strategic Plans and Policies for member states, eight frameworks and guideline documents, as well as a website for RISLNET Central Africa. GHSS has also launched an Extension for Community Health Outcomes platform to supervise laboratories enrolled for accreditation, installed a Basic Laboratory Information System (BLIS) in four laboratories in four member states, and trained 247 laboratory personnel and laboratory experts on BLIS, quality assurance, external quality assurance, Strengthening Laboratory Management Towards Accreditation (SLMTA), quality management systems, and equipment maintenance and calibration. LESSONS LEARNT: Participating laboratories now serve as reference laboratories for COVID-19 testing in various countries. Point-of-care testing, using the GeneXpert platform, has been the central strategy for the scale-up of COVID-19 testing in the Central Africa region. RECOMMENDATIONS: Expanding SLMTA to other laboratories within Central Africa will significantly improve the quality management of laboratories for a better healthcare system. |
|
Original Research Diagnostic challenges with accurate identification of Listeria monocytogenes isolates from food and environmental samples in South Africa Thomas, Teena S.M. Thomas, Juno le Roux, Karren Duze, Sanelisiwe T. Mkhwanazi, Faith Duse, Adriano Resumen en Inglés: BACKGROUND: The 2017-2018 listeriosis outbreak in South Africa warranted testing for Listeria monocytogenes in food products and processing environments. Diagnostic tests are needed to accurately differentiate L. monocytogenes from other Listeria species. OBJECTIVE: The study assessed the performance of the commonly used tests in our setting to accurately identify L. monocytogenes. METHODS: The study was conducted in a public health laboratory in South Africa. Cultured isolates from food and environmental samples were tested both prospectively and retrospectively between August 2018 and December 2018. Isolates were phenotypically identified using tests for detecting β-haemolysis, Christie-Atkins-Munch-Peterson, alanine arylamidase (AlaA), mannosidase, and xylose fermentation. Listeria monocytogenes isolates were identified using automated systems, Microscan Walkaway Plus 96, Vitek® MS, Vitek® 2 and Surefast Listeria monocytogenes PLUS PCR. All results were compared to whole-genome sequencing results. RESULTS: β-haemolysis and Christie-Atkins-Munch-Peterson tests gave delayed positivity or were negative for L. monocytogenes and falsely positive for one strain of Listeria innocua. The AlaA enzyme and Colorex Listeria agar lacked specificity for L. monocytogenes identification. Based on a few phenotypic test results, an aberrant L. monocytogenes strain and Listeria seeligeri strain were reported. All automated platforms overcalled L. monocytogenes in place of other Listeria species. CONCLUSION: No test was ideal in differentiating Listeria species. This is an issue in resource-limited settings where these tests are currently used. Newer technologies based on enzyme-linked immunosorbent assay and other molecular techniques specific to L. monocytogenes detection need to be investigated. |
|
Original Research Cost of running a full-service receiving office at a centralised testing laboratory in South Africa Cassim, Naseem Ramdin, Neeshan Moodly, Sadhaseevan Glencross, Deborah K. Resumen en Inglés: BACKGROUND: The National Health Laboratory Service operates a platform of 226 laboratories across South Africa, ranging from highly sophisticated central academic hospitals to distant rural hospitals. The core function of the National Health Laboratory Service is to provide cost-effective and efficient health laboratory services in the public healthcare sector. OBJECTIVE: This study aimed to assess the comprehensive cost of running a full-service receiving office (RO) at the Charlotte Maxeke Johannesburg Academic Hospital (CMJAH) laboratory. METHODS: Top-down costing was conducted, with the cost per registration as the main outcome of interest. The annual equivalent costs (AEC) for the following categories were determined: registration materials, collection materials, staffing, laboratory equipment, building and electricity, and other operating costs. Data for the period from 01 April 2019 to 31 March 2020 were included in the analyses. RESULTS: The AEC was $1 657 483.00 United States dollars (USD) and the cost per registration was $0.766 USD. Staff contributed 59.9% of the total cost per registration, while collection materials contributed 21.4%. The RO core staff (data clerks) contributed 50.8% of the total staffing costs, while messengers and drivers contributed 31.2%. The introduction of order entry at the CMJAH and other primary healthcare facilities reduced the total AEC by 20%. A single order entry application would serve both the CMJAH and primary healthcare facilities - hence we would prefer to not refer to order entries. CONCLUSION: Providing a comprehensive RO service costs approximately $1.00 USD per registration. The implementation of order entry at the CMJAH would reduce AECs substantially and improve efficiency. |
|
Original Research Appropriate use of plasma glucose tests for diagnosis of diabetes mellitus in Ibadan, Nigeria Kuti, Modupe A. Bamidele, Olabisi T. Udeh, Chioma T. Eseile, Bola J. Ogundeji, Olajumoke A. Resumen en Inglés: BACKGROUND: Diabetes mellitus is a growing epidemic in Africa. Its diagnosis relies exclusively on laboratory evidence, which differs based on clinical circumstances. OBJECTIVE: The study described the appropriateness of plasma glucose test requests per the American Diabetes Association criteria. METHODS: We reviewed the plasma glucose test requests received by the chemical pathology laboratory of the University College Hospital, Ibadan, Nigeria between June 2018 and November 2018. The American Diabetes Association diabetes diagnostic criteria were used to define the appropriateness of test requests and determine the potential for ill-informed clinical decisions. RESULTS: Four hundred and twenty-three requisition forms were included, with the majority from the medical wards/clinics (72.3%); the most frequent reason for a plasma glucose test was systemic hypertension (28.6%). Fasting plasma glucose was most requested (254; 60.0%). One hundred and sixteen (27.4%) requests were potentially inappropriate, with the 2-h postprandial plasma glucose (2hPPG) test requests (83; 71.6%) being the most inappropriate. The difference in the proportion of inappropriate requests was not statistically significantly between medical or surgical wards/clinics (Odds ratio 1.131, 95% confidence interval 0.709-1.803, p = 0.605). Inappropriate requests in six cases may have triggered inappropriate action. CONCLUSION: A third of the glucose tests requested for querying diabetes mellitus may have been inappropriate. Results of such testing may trigger inappropriate clinical action. To improve the quality of care and for economic reasons, laboratories should have programmes to improve the appropriate use of their services. |
|
Reviewer Acknowledgement Acknowledgement to reviewers |
|
Original Research Prevalence of alpha and beta haemolysin among blood group O donors in Bamenda, Cameroon Fondoh, Victor N. Ndzenjempuh, Nobert Stella, Tamunjoh Fondoh, Richard M. Awasom, Charles N. Enow-Tanjong, Rebecca Egbengu, Egbe P. Leke, Robert Rose, Njini F.N. Nsame, Denis Resumen en Inglés: BACKGROUND: The occurrence of high titres of alpha (anti-A) and beta (anti-B) haemolysin immunoglobulin G antibodies in blood causes haemolysis during blood transfusion from a group O donor, commonly and inappropriately known as the 'universal blood donor', to a group A, B or AB recipient. Surprisingly, haemolysin testing is not routinely done during blood transfusion services in Bamenda, Cameroon OBJECTIVE: This study aimed to determine the prevalence of haemolysin among blood group 'O' donors at the Regional Hospital Bamenda Blood Bank, Bamenda, Cameroon METHODS: This was a cross-sectional descriptive study carried out between June and September 2020 at the Regional Hospital Bamenda Blood Bank, Bamenda, Cameroon. Blood group O donors who were free from transfusion-transmissible infections were selected systematically and serially and their serum tested for the presence of haemolysin. Haemolysin titres were determined, and titres ≥ 8 were considered significant. The associations between haemolysin prevalence and age group, gender and Rhesus D blood group were determined using the chi-square test RESULTS: The prevalence of haemolysin among the 480 study participants was 52.1% and significant haemolysin titres were detected in 18.5%. There was no association between haemolysin and gender, age group or the Rhesus D blood group CONCLUSION: The prevalence of significant titres of haemolysin among participants in this study was high. There is the need to test for haemolysin in blood group O donors to prevent the potential risk to blood group A, B, and AB recipients and to provide safer blood for transfusion |
|
Opinion Papers Challenges and complexities in evaluating severe acute respiratory syndrome coronavirus 2 molecular diagnostics during the COVID-19 pandemic Scott, Lesley E. Noble, Lara D. Singh-Moodley, Ashika Kahamba, Trish Hardie, Diana R. Preiser, Wolfgang Stevens, Wendy S. |
|
Original Research Aetiology of pancytopenia: Experience of a South African tertiary academic centre Nell, Erica-Mari Chapanduka, Zivanai C. Resumen en Inglés: BACKGROUND: Pancytopenia is a manifestation of numerous disease entities. The causes of pancytopenia differ with geographic region, socio-economic factors and HIV prevalence. Awareness of the common causes of pancytopenia may aid timely diagnosis OBJECTIVE: This study aimed to determine the aetiology of pancytopenia in a South African population METHODS: A retrospective observational study of adult patients presenting with pancytopenia at Tygerberg Academic Hospital, South Africa, from January 2016 to December 2017 was performed. Data on pancytopenia cases were obtained from the laboratory information system and utilised to determine the causes of pancytopenia RESULTS: A total of 673 cases of pancytopenia were identified. The most common causes of pancytopenia were chemoradiation therapy (25%), sepsis (18%), haematological malignancy (9%), advanced HIV (7%), and megaloblastic anaemia (6%). The diagnostic yield of bone marrow examinations (BME) was 57% (n = 52/91). The aetiology of pancytopenia differed according to age, with malignancy being a more common cause of pancytopenia among the elderly CONCLUSION: Several easily recognisable and treatable conditions can manifest as pancytopenia. Prompt management of such conditions, notably sepsis and megaloblastic anaemia, can result in the resolution of the cytopenias and negate the need for a BME. However, haematological malignancy and unexplained pancytopenia strongly rely on a BME to establish a diagnosis. Pancytopenia investigations, when guided by appropriate clinic-laboratory findings, can promptly identify the underlying aetiology, while also identifying cases where an expedited BME is required. This is valuable in resource-conscious medicine |
|
Editorial COP27 Climate Change Conference: Urgent action needed for Africa and the world Atwoli, Lukoye Erhabor, Gregory E. Gbakima, Aiah A. Haileamlak, Abraham Ntumba, Jean-Marie Kayembe Kigera, James Laybourn-Langton, Laurie Mash, Robert Muhia, Joy Mulaudzi, Fhumulani M. Ofori-Adjei, David Okonofua, Friday Rashidian, Arash El-Adawy, Maha Sidibé, Siaka Snouber, Abdelmadjid Tumwine, James Mohammad, Sahar Yassien Yonga, Paul Zakhama, Lilia Zielinski, Chris |
|
Original Research Efficacy of diversely isolated lytic phages against multi-drug resistant Enterobacter cloacae isolates in Kenya Mutai, Ivy J. Juma, Angela A. Inyimili, Martin I. Nyachieo, Atunga Nyamache, Anthony K. Resumen en Inglés: BACKGROUND: Enterobacter cloacae causes nosocomial infections in 15% of patients in low- and middle-income countries with emergence of carbapenem resistance. The utilisation of bacteriophages for therapeutic purposes is crucial for eradicating these resistant bacterial strains. OBJECTIVE: This study evaluated the efficacy of lytic phages on bacterial isolates of E. cloacae and determined their stability in various physicochemical conditions. METHODS: Twenty-nine lytic phages were isolated from the waste water of six informal settlements in Nairobi County, Kenya, from July 2019 to December 2020 and cross-reacted with 30 anonymised clinical isolates of E. cloacae. Six phages were then selected for physicochemical property studies. Phages were described as potent upon lysing any bacterial strain in the panel. RESULTS: Selected phages were stable at 4 °C - 50 °C with a 5.1% decrease in titre in four of six phages and a 1.8% increase in titre in two of six phages at 50 °C. The phages were efficient following two weeks incubation at 4 °C with optimal activity at human body temperature (37 °C) and an optimal pH of 7.5. Phages were active at 0.002 M and 0.015 M concentrations of Ca2+ ions. The efficiency of all phages decreased with increased exposure to ultraviolet light. All phages (n = 29) showed cross-reactivity against anonymised clinical isolates of E. cloacae strains (n = 30). The most potent phage lysed 67.0% of bacterial strains; the least potent phage lysed 27.0%. CONCLUSION: This study reveals the existence of therapeutic phages in Kenya that are potent enough for treatment of multi-drug resistant E. cloacae. |
|
Original Research Bacteriological profile and antibiogram of blood culture isolates from bloodstream infections in a rural tertiary hospital in Nigeria Oyekale, Oluwalana T. Ojo, Bola O. Olajide, Adewale T. Oyekale, Oluwatoyin I. Resumen en Inglés: BACKGROUND: Bloodstream infections (BSIs) are a cause of significant morbidity and mortality requiring urgent antibiotic treatment. However, there is widespread antibiotic-resistance from the bacterial causes, necessitating regular surveillance for drug-resistant bacteria and their antibiograms. OBJECTIVE: This study isolated and identified various bacterial causes of BSIs, determined their antibiotic susceptibility patterns, and determined the best empirical treatment for cases of BSI in the setting METHODS: A cross-sectional study was carried out at the Federal Teaching Hospital, Ido-Ekiti, Nigeria between June 2020 and February 2021 on 177 blood culture samples from cases of BSI. Identification of isolated bacteria and antibiotic susceptibility testing of the isolates were carried out following the standard protocol. RESULTS: Culture positivity in this study was 19.2%. No significant difference was seen in culture positivity between male and female participants (p = 0.97). Gram-negative enteric bacteria were predominantly isolated (67.6%), including Escherichia coli (29.4%) and Klebsiella aerogenes (20.6%). Staphylococcus aureus was the most common Gram-positive bacterium isolated (23.5%). Three (37.5%) S. aureus isolates were methicillin-resistant. All isolates were sensitive to meropenem, and 97.1% were sensitive to imipenem; other sensitivity patterns were: ceftazidime (85.3%), ciprofloxacin (79.4%), ofloxacin (79.4%), and gentamicin (76.5%). There was low sensitivity to ampicillin (32.4%) and cotrimoxazole (38.2%). All Gram-positive isolates, including methicillin-resistant S. aureus, were sensitive to vancomycin CONCLUSION: Regular surveillance of isolate sensitivity patterns, formulation of hospital antibiotic policies based on existing data and compliance with treatment guidelines will promote rational antibiotic use and reduce resistance among bacteria. |
|
Scientific Letter Appropriate disposal of waste in the laboratory: Neglected but not forgotten Opperman, Christoffel J. Singh, Sarishna Barton, Francois |
|
Original Research Global Antimicrobial Resistance and Use Surveillance System on the African continent: Early implementation 2017-2019 Tornimbene, Barbara Eremin, Sergey Abednego, Reuben Abualas, Elamin O. Boutiba, Ilhem Egwuenu, Abiodun Fuller, Walter Gahimbare, Laetitia Githii, Susan Kasambara, Watipaso Lukwesa- Musyani, Chileshe Miamina, Fidy A. Zinyowera, Sekesai Mtapuri- Najjuka, Grace Perovic, Olga Zayed, Bassem Ahmed, Yahaya A. Ismail, Maha T. Silva, Carmem L. Pessoa da Resumen en Inglés: BACKGROUND: Antimicrobial resistance (AMR) is becoming a critical public health issue globally. The World Health Organization launched the Global Antimicrobial Resistance and Use Surveillance System (GLASS) to support the strengthening of the AMR evidence base OBJECTIVE: The article describes the evolution of national AMR surveillance systems and AMR data reporting of countries in the African continent between 2017 and 2019, and the constraints, perceived impact and value of the participation in GLASS METHODS: Data on implementation of national surveillance systems and AMR rates were submitted to GLASS between 2017 and 2019 and summarised though descriptive statistics. The information on constraints and perceived impact and value in GLASS participation was collected though a set of questionnaires RESULTS: Between 2017 and 2019, Egypt, Ethiopia, Madagascar, Malawi, Mali, Mozambique, Nigeria, South Africa, Sudan, Tunisia, Uganda and Zambia submitted data to GLASS. The main constraints listed are linked to scarce laboratory capacity and capability, limited staffing, budget issues, and data management. Moreover, while the data are not yet nationally representative, high resistance rates were reported to commonly-used antibiotics, as the emerging resistance to last treatment options CONCLUSION: Despite the limitations, more and more countries in the African continent are working towards reaching a status that will enable them to report AMR data in a complete and systematic manner. Future improvements involve the expansion of routine surveillance capacity for several countries and the implementation of surveys that allow to effectively define the magnitude of AMR in the continent |
|
Original Research Hepatitis B virus infection and HBeAg positivity among pregnant women in South West Uganda Mugabiirwe, Naome Kalyetsi, Rogers Ayella, Richard Obote, James Ssedyabane, Frank Resumen en Inglés: BACKGROUND: Hepatitis B virus is a public health burden in Uganda, yet little is known about its epidemiology in pregnancy. OBJECTIVE: This study aimed at determining the prevalence and associated risk factors of hepatitis B virus infection among pregnant women attending antenatal care at the Kyazanga Health Centre IV in Lwengo District, Uganda. METHODS: This cross-sectional study was conducted from April 2021 to June 2021 and analysed qualitative data that were collected using a structured in-person questionnaire. Aseptically collected blood specimens were screened for hepatitis B virus infection using an immunochromatographic rapid diagnostic test kit. Participants who were positive for the hepatitis B surface antigen (HBsAg) were further screened for hepatitis B envelope antigen (HBeAg) using commercial rapid diagnostic test kits. RESULTS: Out of 384 pregnant women studied, eight tested positive for HBsAg. This gave a prevalence of 2.1% (95% confidence interval: 1.0% - 4.1%); 5/8 (62.5%) were positive for HBeAg. None of the variables studied were significantly associated with HBsAg positivity among pregnant women. CONCLUSION: Hepatitis B viral infection is still a public health challenge in pregnant women with possible risk for vertical transmission to their babies in the study area. We recommend routine screening for hepatitis B virus in pregnancy in addition to strengthening current strategies aimed at controlling and preventing hepatitis B infection spread and transmission. |
|
Original Research Occurrence and antimicrobial susceptibility patterns of Salmonella species from poultry farms in Ibadan, Nigeria Orum, Terese G. Ishola, Olayinka O. Adebowale, Oluwawemimo O. Resumen en Inglés: BACKGROUND: Salmonella species are among the major foodborne pathogens causing diseases of economic and public health implications in poultry and humans globally. OBJECTIVE: This study aimed to determine the occurrence and antimicrobial susceptibility patterns of Salmonella isolates from chickens in poultry farms in Ibadan, Southwest Nigeria. METHODS: Cloacal swab samples (n = 360) were obtained from chickens randomly selected from 10 poultry farms in five local government areas of Ibadan, Oyo State, from 04 April 2018 to 20 November 2018. Bacterial identification and antimicrobial susceptibility testing were performed using established protocols. Data were analysed using descriptive statistics and Pearson's chi-squared test at P ≤ 0.05 significance level. RESULTS: The overall prevalence of Salmonella was 21.4%. There were statistically significant associations between Salmonella prevalence and the farm location (p = 0.003), age of chickens (p < 0.001), and health status of chickens (p < 0.001). All Salmonella isolates (n = 77; 100.0%) were resistant to cefuroxime. The isolates were also highly resistant to cotrimoxazole (n = 74; 96.1%), chloramphenicol (n = 73; 94.8%), meropenem (n = 72; 93.5%), gentamicin (n = 69; 89.6%), and tetracycline (n = 64; 83.1%). CONCLUSION: The presence of drug-resistant Salmonella in commercial layer chickens in Ibadan is a potential threat to consumer health as it increases the risk of carcass contamination and pathogen propagation, and limits the options to control and treat infections in humans and animals. Well-integrated national surveillance systems for monitoring Salmonella and antimicrobial resistance in poultry are critical. |
|
Original Research Effect of sputum quality and role of Xpert® MTB/RIF assay for detection of smear-negative pulmonary tuberculosis in same-day diagnosis strategy in Addis Ababa, Ethiopia Sinshaw, Waganeh Kebede, Abebaw Bitew, Adane Tadesse, Mengistu Mehamed, Zemedu Alemu, Ayinalem Yenew, Bazezew Amare, Misikir Dagne, Biniyam Diriba, Getu Tesfaye, Ephrem Gamtesa, Dinka F. Abebaw, Yeshiwork Mollalign, Helina Seid, Getachew Getahun, Muluwork Resumen en Inglés: BACKGROUND: There is limited information on the performance of the Xpert® MTB/RIF test for diagnosis of smear-negative pulmonary tuberculosis (SNPT) and rifampicin resistance (RR) in the same-day diagnosis approach. The effects of sputum quality and other factors affecting the Xpert performance are also under-investigated OBJECTIVE: This study aimed to determine the performance of the Xpert® MTB/RIF test for detection of SNPT and RR in the same-day diagnosis strategy and the effect of sputum quality and other factors on its performance METHODS: A cross-sectional study was conducted from August 2017 to January 2018 across 16 health facilities in Addis Ababa, Ethiopia. Two spot sputum samples were collected from 418 presumptive SNPT patients, tested with Xpert® MTB/RIF, then compared to tuberculosis culture. Additionally, culture isolates were tested for RR by BACTEC MGIT™ 960 drug susceptibility testing (DST) and MTBDRplus version 2 RESULTS: The Xpert® MTB/RIF test detected 24 (5.7%) SNPT cases, with a sensitivity of 92.3% (75.9% - 97.9%) and specificity of 99.2% (97.8% - 99.7%) compared with tuberculosis culture. Xpert® MTB/RIF also detected three (11.58%) RR strains with 100.0% concordance with BACTEC MGIT™ 960 DST and MTBDRplus results. Three blood-stained SNPT samples were positive by Xpert (30.0%), which was 6.9 times higher compared to salivary sputum (odds ratio: 6.9, 95% confidence interval: 1.36-34.96, p = 0.020 CONCLUSION: The performance of the Xpert® MTB/RIF to detect SNPT and RR in same-day diagnosis is high. However, SNPT positivity varies among sputum qualities, and good sample collection is necessary for better test performance |
|
Original Research Establishment of haemoglobin A2 reference intervals in Pretoria, South Africa: A retrospective secondary data analysis Nieuwenhuizen, Cailin Netshidzivhani, Tshiphiri Potgieter, Johan Resumen en Inglés: BACKGROUND: Haemoglobinopathies are one of the most common inherited diseases worldwide. Quantification of haemoglobin A2 is necessary for the diagnosis of the beta thalassaemia trait. In this context, it is important to have a reliable reference interval for haemoglobin A2 and a local reference range for South Africa has not been established OBJECTIVE: This study aimed to establish reference intervals for haemoglobin A2 using stored patient laboratory data METHODS: This descriptive study used retrospective data to evaluate haemoglobin A2 levels determined using high-performance liquid chromatography at the National Health Laboratory Service haematology laboratory in Pretoria, South Africa. All tests performed from 01 October 2012 to 31 December 2020 were screened for inclusion; of these, 144 patients' data met the selection criteria. The reference interval was calculated using descriptive statistics (mean and standard deviation) with a 95% confidence interval RESULTS: Analysed data from enrolled patients showed a normal distribution. The mean age of the patients was 40 years (range: 3-84 years). The reference interval for haemoglobin A2 calculated from this data was 2.3% - 3.6%. The minimum haemoglobin A2 was 2.3% and the maximum was 3.9% with a mean of 2.95% and a standard deviation of 0.357% CONCLUSION: A normal reference interval has been established for the population served by the laboratory that will assist with accurate diagnosis of the beta thalassaemia trait. This reference interval may also be useful to other laboratories that employ the same technology, especially smaller laboratories where obtaining a sufficiently large number of normal controls may be challenging |
|
Original Research Comparison of commercial assays and two-step approach to detect Clostridioides difficile in South Africa Singh, Sarishna Newton-Foot, Mae Nel, Pieter Pienaar, Colette Resumen en Inglés: BACKGROUND: Clostridioides difficile is the number one cause of hospital-acquired diarrhoea. Accurate diagnosis of C. difficile is of utmost importance as it guides patient management and infection control practices. Studies evaluating the performance of commercially available nucleic acid amplification tests (NAATs) versus algorithms are lacking in resource-limited settings. OBJECTIVE: This study assessed the performance of three commercially available tests and a two-step approach for the diagnosis of C. difficile infection using toxigenic culture (TC) as the gold standard. METHODS: Two hundred and twenty-three non-duplicate loose stool samples were submitted to the National Health Laboratory Service Microbiology Laboratory at Tygerberg Hospital, Cape Town, South Africa, from October 2017 to October 2018. The samples were tested in parallel using the C. DIFF QUIK CHEK COMPLETE enzyme immunoassay (EIA) and two NAATs (Xpert C. difficile and BD MAX Cdiff), and the results were compared to TC. The performance of a two-step approach consisting of the C. DIFF QUIK CHEK COMPLETE followed by the Xpert C. difficile was also determined. RESULTS: Of 223 faecal specimens tested, 37 (16.6%) were TC-positive. The sensitivity and specificity of the C. DIFF QUIK CHEK COMPLETE were 54.1% and 98.9%; Xpert C. difficile, 86.4% and 96.8%; BD MAX Cdiff, 89.2% and 96.8%; and two-step approach, 89.2% and 96.2%. CONCLUSION: The C. DIFF QUIK CHEK COMPLETE, in a two-step approach with the Xpert C. difficile, performed similarly to the NAATs on their own and offer advantages in terms of cost and workflow in low-resource settings. |
|
Original Research GeneXpert rollout in three high-burden tuberculosis countries in Africa: A review of pulmonary tuberculosis diagnosis and outcomes from 2001 to 2019 Williams, Victor Calnan, Marianne Edem, Bassey Onwuchekwa, Chukwuemeka Okoro, Chika Candari, Christine Cruz, Rhodora Otwombe, Kennedy Resumen en Inglés: BACKGROUND: The rollout of GeneXpert aimed at increasing early diagnosis of tuberculosis to improve treatment outcomes and global tuberculosis targets. OBJECTIVE: This study evaluated trends in tuberculosis diagnosis and outcomes pre- and post-introduction of GeneXpert in three African countries - the Democratic Republic of the Congo (DRC), Nigeria and South Africa. METHODS: Data from 2001 to 2019 were extracted from the World Health Organization's data repository. Descriptive analysis, paired t-tests and interrupted time series models were used. RESULTS: Estimated tuberculosis incidence decreased from 327/100 000 to 324/100 000 in the DRC, and from 1220/100 000 to 988/100 000 in South Africa. Incidence remained at 219/100 000 in Nigeria. The tuberculosis case notification rate did not change significantly. Increases in the new case treatment success rates were statistically significant (DRC: p = 0.0201; Nigeria: p = 0.0001; South Africa: p = 0.0017); decreases in mortality were also statistically significant (DRC: p = 0.0264; Nigeria: p = 0.0001; South Africa: p < 0.0001). Time series models showed insignificant increases in new tuberculosis cases in DRC (n = 1856, p = 0.085) and Nigeria (n = 785, p = 0.555) from 2011 to 2019; and a statistically significant decrease in South Africa (n = 15 269, p = 0.006). CONCLUSION: Improvements in tuberculosis treatment outcomes were achieved, but little progress has been made in new case notification due to varied implementation and scale-up of GeneXpert across the three countries. Implementation barriers need to be addressed to achieve the required tuberculosis targets. |
Lea la Declaración de Acceso abierto
