Table of contents
African Journal of Laboratory Medicine, Volume: 10, Issue: 1, Published: 2021African Journal of Laboratory Medicine, Volume: 10, Issue: 1, Published: 2021
| Documents |
|---|
|
Lessons from the Field Setting up a molecular diagnostic laboratory for SARS-CoV-2 testing: Experience of a single centre in a resource-constrained setting Osaigbovo, Iriagbonse I. Igbarumah, Isaac O. Muoebonam, Ekene B. Obaseki, Darlington E. Abstract in English: BACKGROUND: Molecular detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is at the forefront of the global response to the coronavirus disease 2019 (COVID-19) pandemic. However, molecular diagnostic capabilities are poorly developed in many African countries. Efforts by the Nigeria Centre for Disease Control and other public health agencies to scale up facilities for molecular testing across the continent are well documented, but there are few accounts from the laboratories at the frontlineINTERVENTION: As part of an institutional response to the COVID-19 pandemic, the University of Benin Teaching Hospital, Benin City, Nigeria, signed a memorandum of understanding with a World Bank-supported institution to obtain a non-proprietary testing platform, renovated an existing molecular virology laboratory and validated the test process to make SARS-CoV-2 testing readily available for decision-making by frontline health workers. These efforts resulted in the University of Benin Teaching Hospital's inclusion in the Nigeria Centre for Disease Control COVID-19 molecular laboratory network. The laboratory achieved a turnover of 12 123 tests within 7 months of operation. Challenges faced and dealt with include incompatible equipment, limited skilled manpower, unstable (unreliable) electric power supply, disrupted procurement and supply chain, and significant overhead costsLESSONS LEARNT: Molecular diagnostic capability is essential in laboratory preparedness for pandemic response and can be achieved by establishing collaborative networks in low-resource settingsRECOMMENDATIONS: Molecular diagnostic capabilities attained during the COVID-19 pandemic should be maintained by governmental support of the local biotechnology sector, collaboration with partners and stakeholders and the expansion of diagnostics to include other diseases of public health importance |
|
Original Research Comparison of 24-hour versus random urine samples for determination and quantification of Bence Jones protein in a South African population Reddy, Ashandree Rapiti, Nadine Gounden, Verena Abstract in English: BACKGROUND: The International Myeloma Working Group and College of American Pathologists recommend a 24-h urine collection to determine the Bence Jones protein (BJP) excretion level for monitoring treatment response in patients with multiple myeloma (MM). There are several issues related to sample collection and the method is prone to inaccuracyOBJECTIVE: This study compared measured 24-h to random urine collections for the quantitation of BJP in a South African populationMETHODS: Sixty-six patients with MM submitted random urine samples with their routine 24-h urine collection from April 2016 - March 2018. Measured 24-h urine BJP was compared to two estimated 24-h BJP excretions calculated as follows: Estimation 1 (E1): Estimated 24-h BJP (mg/24 h) = Urine BJP/Creatinine ratio (mg/mmol) × 10. Estimation 2 (E2): Estimated 24-h BJP (mg/24 h) = Urine BJP/Creatinine ratio (mg/mmol) × 15 mg/kg for women or × 20 mg/kg for menRESULTS: Correlation of estimation equations E1 and E2 to the measured 24-h urine BJP was 0.893. Patients showed no difference in classification of treatment response using either the E1 or E2 estimation equations when compared to the measured 24-h urine BJP resultsCONCLUSION: This study demonstrates that the estimated 24-h BJP shows a high degree of correlation with the measured 24-h BJP and can likely be used to monitor treatment response in South African patients with MM |
|
Original Research Operational analysis of the national sickle cell screening programme in the Republic of Uganda Hernandez, Arielle G. Kiyaga, Charles Howard, Thad A. Ssewanyana, Isaac Ndeezi, Grace Aceng, Jane R. Ware, Russell E. Abstract in English: BACKGROUND: Sickle cell anaemia is a common global life-threatening haematological disorder. Most affected births occur in sub-Saharan Africa where children usually go undiagnosed and die early in life. Uganda's national sickle cell screening programme was developed in response to a 2014 sickle cell surveillance study that documented a high disease prevalenceOBJECTIVE: This study describes the temporal and financial aspects of Uganda's 2014-2019 sickle cell screening programmeMETHODS: National sickle cell screening data from Uganda's Central Public Health Laboratories were used to calculate turn-around times (TATs) from sample collection to delivery, testing, and result reporting for blood samples collected from February 2014 to March 2019. The parameters affecting specific TATs were assessed. The exact programme expenditures were analysed to determine cost per test and per positive sickle cell disease case detectedRESULTS: A total of 278 651 samples were analysed. The median TAT from sample collection to laboratory receipt was 8 days (interquartile range [IQR]: 6-12), receipt to testing was 3 days (IQR: 1-7), and testing to result reporting was 6 days (IQR: 3-12). Altogether, the sample continuum averaged 16 days (IQR: 11-24). Lower level healthcare facilities were associated with longer sample delivery TATs. Calendar months (January and December) and larger sample volumes impacted testing and result reporting TATs. The cost per test was $4.46 (United States dollars [USD]) and $483.74 USD per positive case detectedCONCLUSION: Uganda's sickle cell screening programme is efficient and cost-effective. Universal newborn screening is the best strategy for detecting sickle cell anaemia in Uganda |
|
Original Research Could ante-mortem computed tomography be useful in forensic pathology of traumatic intracranial haemorrhage? Hlahla, Mmachuene I. Selatole, Moshibudi J. Abstract in English: BACKGROUND: Imaging techniques have proven valuable in forensic pathology practice, with computed tomography being preferred for forensic use. In the era of virtual autopsy and a low- to middle-income, resource-constrained country, a question arises as to whether ante-mortem computed tomography (ACT) could be cost-effective by reducing the number of invasive autopsies performedOBJECTIVE: The objective of this study was to assess the usefulness of ACT in forensic pathology by examining discrepancy rates between ACT scans and autopsy findings in cases of deceased individuals with traumatic intracranial haemorrhages and assess factors associated with discrepanciesMETHODS: Eighty-five cases of ACT and autopsy reports from 01 January 2014 to 31 December 2016 from the Polokwane Forensic Pathology Laboratory, South Africa, were analysed retrospectively. Using Cohen's kappa statistics, measures of agreement and resultant discrepancy rates were determined. Also, the discrepancy patterns for each identified factor was also analysedRESULTS: The discrepancy rate between ACT and autopsy detection of haemorrhage was 24.71% while diagnostic categorisation of haemorrhage was 55.3%. Classification discrepancy was most observed in subarachnoid haemorrhages and least observed in extradural haemorrhages. A markedly reduced level of consciousness, hospital stay beyond two weeks and three or fewer years of doctors' experience contributed to classification discrepanciesCONCLUSION: Ante-mortem computed tomography should be used only as an adjunct to autopsy findings. However, the low discrepancy rate seen for extradural haemorrhages implies that ACT may be useful in the forensic diagnosis of extradural haemorrhages |
|
Original Research Pre-evaluation assessment of serological-based COVID-19 point-of-care lateral flow assays in Kenya Kimotho, James H. Gosar, Abdiaziz A. Inyangala, Ronald Wairimu, Paulyne Siyoi, Fred Matoke-Muhia, Damaris Wanjala, Cecilia Zablon, Jeremiah Orina, Moses Muita, Lucy Thiga, Jacqueline Nyabuti, Lameck Wainaina, Eunice Mwangi, Joseph Mumbi, Alice Omari, Samuel Wanjiru, Ann Nzou, Samson M. Ochwoto, Missiani Abstract in English: BACKGROUND: Timely testing is a key determinant of management outcomes of coronavirus disease 2019 (COVID-19). Real-time reverse transcription polymerase chain reaction tests are currently the mainstay for COVID-19 testing. However, serological point-of-care tests (PoCTs) can be useful in identifying asymptomatic and recovered cases, as well as herd immunityOBJECTIVE: The aim of this study was to assess COVID-19 PoCTs in Kenya to support the emergency use authorisation of these testsMETHODS: Between March 2020 and May 2020, 18 firms, of which 13 were from China, submitted their PoCTs to the national regulatory authority, the Pharmacy and Poison Board, who in turn forwarded them to the Kenya Medical Research Institute for pre-evaluation assessment. The tests were run with real-time reverse transcription polymerase chain reaction COVID-19-positive samples. Pre-COVID-19 plasma samples that were collected in June 2019 were used as negative samples. The shelf lives of the PoCTs ranged from 6 to 24 monthsRESULTS: Only nine (50%) tests had sensitivities ≥ 40% (range: 40% - 60%) and the ability of these tests to detect IgM ranged from 0% to 50%. Many (7/18; 38.9%) of the kits had very weak IgM and IgG band intensities (range: 2-3CONCLUSION: Serological-based PoCTs available in Kenya can only detect COVID-19 in up to 60% of the infected population |
|
Original Research Molecular characterisation of NPM1 and FLT3-ITD mutations in a central South African adult de novo acute myeloid leukaemia cohort Kloppers, Jean F. Kock, André de Cronjé, Johané van Marle, Anne-Cecilia Abstract in English: BACKGROUND: Recognition of molecular abnormalities in acute myeloid leukaemia (AML) has improved our understanding of its biology. NPM1 and FLT3-ITD mutations are recurrent in AML and clinically significant. NPM1 mutations are associated with a favourable prognosis, while FLT3-ITD mutations are an independent poor prognostic factor in AMLOBJECTIVE: This study described the prevalence and molecular characteristics of the NPM1 and FLT3-ITD mutations in a newly diagnosed AML patient cohort in central South AfricaMETHODS: The study included 40 de novo AML patients. An NPM1 and FLT3-ITD multiplex polymerase chain reaction assay was optimised to screen patients for the respective mutations and were confirmed using Sanger sequencing. The prevalence of the NPM1 and FLT3-ITD mutations were determined, and mutation-specific characteristics were described in relation to patients' demographic information and AML classificationsRESULTS: The patients' median age was 38.5 years, with 77.5% (n = 31) of patients being self-proclaimed Black Africans. AML with recurrent genetic abnormalities was most prevalent (57.5%; n = 23), of which acute promyelocytic leukaemia (APL) was most common (40.0%; n = 16). None of the patients had the NPM1 mutation. FLT3-ITD was present in 37.5% (6/16) of APL patients and in one (20.0%) of five AML patients with a t(8;21) translocation. Most patients had an FLT3-ITD allele ratio of ≥ 50% and ITD lengths of > 39 bpCONCLUSION: FLT3-ITD mutations were mainly found in APL cases at a similar prevalence as reported in the literature. High FLT3-ITD allele ratios and long ITD lengths predominated. No NPM1 mutations were detected |
|
Original Research Molecular red cell genotyping of rare blood donors in South Africa to enhance rare donor-patient blood matching Govender, Lavendri Prakashchandra, Rosaley D. Pillay, Pavitra Jentsch, Ute Abstract in English: BACKGROUND: Molecular red cell genotyping is devoid of serology limitations such as the scarcity of rare antisera and the possibility of inconclusive results due to biological interferences. Blood incompatibility can result in immune transfusion reactions such as haemolytic transfusion reactions or haemolytic disease of the foetus and newbornOBJECTIVE: The study aimed to use molecular red cell genotyping to identify rare blood group donors among South African blood donorsMETHODS: Red cell genotyping data were extracted retrospectively from the BIDS XT genotyping software in the Immunohaematology Reference Laboratory from January 2015 to August 2016. The ID CORE XT genotyping assay was used to identify the single nucleotide polymorphisms of 10 blood groups system alleles in 150 donors. Associations between the resultant genotypes and predicted phenotypes, ABO group, RhD type, race group and gender were studiedRESULTS: Significant red cell genetic variability was noted among the numerous South African donor genotypes identified in this study. Genotyping further confirmed the presence of at least one of the 16 rare genotypes in 50 donors. Group O Black donors were associated with two rare blood types, while several other rare blood types were found only in White donors, supporting an association between ABO/Rh subtype, race group and rare blood typesCONCLUSION: Targeted screening of donors for antigen-negative rare blood units for patients should be done to reduce the risk of haemolytic transfusion reactions and haemolytic disease of the foetus and newborn |
|
Original Research An oral history of medical laboratory development in francophone West African countries Koster, Winny Ndione, Albert G. Adama, Mourfou Guindo, Ibrehima Sow, Iyane Diallo, Souleymane Sakandé, Jean Ondoa, Pascale Abstract in English: BACKGROUND: Underdeveloped and underused medical laboratories in sub-Saharan Africa negatively affect the diagnosis and appropriate treatment of ailmentsOBJECTIVE: We identified political, disease-related and socio-economic factors that have shaped the laboratory sector in Senegal, Mali and Burkina Faso to inform laboratory-strengthening programmesMETHODS: We searched peer-reviewed and grey literature from February 2015 to December 2018 on laboratory and health systems development from colonial times to the present and conducted in-depth interviews with 73 key informants involved in (inter)national health or laboratory policy, organisation, practice or training. This article depended on the key informants' accounts due to the paucity of literature on laboratory development in francophone West African countries. Literature and interview findings were triangulated and are presented chronologicallyRESULTS: Until around 1990 there were a few disease-specific research laboratories; only the larger hospitals and district health facilities housed a rudimentary laboratory. The 1990s brought the advent of donor-dictated, vertical, endemic and epidemic disease programmes and laboratories. Despite decentralising from the national level to the regional and district levels, these vertical laboratory programmes biased national health resource allocation deleteriously neglecting the development of the horizontal, general-health laboratory. After the year 2000, the general-health laboratory system received more attention when, influenced by the World Health Organization, national networks and (sub-)directorates of laboratories were installedCONCLUSION: To advance national general healthcare, as opposed to disease-specific healthcare, national laboratory directors and experts in general laboratory development should be consulted when national policies are made with potential laboratory donors |
|
Brief Report Epstein-Barr virus, human papillomavirus and herpes simplex virus 2 co-presence severely dysregulates miRNA expression Okoye, Jude O. Ngokere, Anthony A. Onyenekwe, Charles C. Omotuyi, Olaposi Dada, Deborah I. Abstract in English: This cross-sectional study evaluated the expression of miR-let-7b, miR-21, miR-125b, miR-143, miR-145, miR-155, miR-182, miR-200c, p53 gene, Ki67, SCCA1 and CD4+ T-cell counts among 319 women, to Epstein-Barr virus, human papillomavirus and herpes simplex virus 2 mono-infections and co-infections, using enzyme-linked immunosorbent assay and reverse transcriptase-polymerase chain reaction methods. This study suggests that malignancies associated with viral co-infection could be diagnosed early by monitoring cluster of differentiation 4+ T-cell counts and serum expression of miR-145 and miR-182. |
|
Original Research Knowledge, attitude and practices of COVID-19 among medical laboratory professionals in Zambia Chawe, Adon Mfune, Ruth L. Syapiila, Paul M. Zimba, Sharon D. Vlahakis, Pipina A. Mwale, Samson Mwape, Kapambwe Kalolekesha, Memory Chirambo- Chileshe, Misheck Mutale, Joseph Mudenda, Tobela Manda, Grace Daka, Victor Abstract in English: BACKGROUND: Coronavirus disease 2019 (COVID-19) is a novel disease that has spread to nearly every country worldwide. Medical laboratory professionals are key in the fight against COVID-19 as they provide confirmatory diagnosis for subsequent management and mitigation of the disease. OBJECTIVE: This study investigated the knowledge, attitude and practices of COVID-19 and their predictors among medical laboratory personnel in Zambia. METHODS: We conducted a cross-sectional study among medical laboratory professionals in Zambia from 10 to 29 June 2020. Data were collected using Google Forms and exported to Statistical Package for Social Sciences version 23 for statistical analysis. Independent predictors of COVID-19 knowledge and practices were determined. Adjusted odds ratios (AOR) and their 95% confidence intervals (CI) are reported. RESULTS: A total of 208 medical laboratory professionals, 58.2% male, participated in the study. The majority of respondents had good knowledge (84.1%) and practice (75.0%) regarding COVID-19. Predictors of good knowledge included having a bachelor's degree (AOR: 5.0, CI: 1.13-22.19) and having prior COVID-19 related training (AOR: 8.83, CI: 2.03-38.44). Predictors of good practice included having a master's or Doctor of Philosophy (PhD) qualification (AOR: 5.23, CI: 1.15-23.87) and having prior COVID-19 related training (AOR: 14.01, CI: 6.47-30.36. CONCLUSION: Our findings revealed that medical laboratory professionals in Zambia have good knowledge regarding COVID-19. There is need for continuous professional development to ensure that medical laboratory professionals are well informed and aware of best practices to aid in curbing the pandemic. |
|
Scientific Letter Post-mortem diagnosis of COVID-19 Mungmungpuntipantip, Rujittika Wiwanitkit, Viroj |
|
Lessons from the Field From benchmarking to best practices: Lessons from the laboratory quality improvement programme at the military teaching hospital in Cotonou, Benin Zohoun, Alban Agbodandé, Tatiana B. Kpadé, Angélique Goga, Raliatou O. Gainsi, René Balè, Paul Sambo, Bibata M. Charlebois, Remi Crane, Rachel Merkel, Michele Anani, Ludovic Milgotina, Ekaterina Abstract in English: BACKGROUND: In 2015, the Army Teaching Hospital-University Teaching Hospital (HIA-CHU [Hôpital D'instruction des Armées de Cotonou Centre Hospitalier et Universitaire]) laboratory in Benin launched a quality improvement programme in alignment with the World Health Organization Regional Office for Africa's Stepwise Laboratory Improvement Process Towards Accreditation (SLIPTA). Among the sub-Saharan African laboratories that have used SLIPTA, few have been francophone countries, and fewer have belonged to a military health system. The purpose of this article was to outline the strategy, implementation, outcomes and military-specific challenges of the HIA-CHU laboratory quality improvement programme from 2015 to 2018. INTERVENTION: The strategy for the quality improvement programme included: external baseline SLIPTA evaluation, creation of work plan based on SLIPTA results, execution of improvement projects guided by work plan, assurance of accountability via regular meetings, training of personnel to improve personnel competencies, development of external stakeholder relationships for sustainability and external follow-up post-SLIPTA evaluation. LESSONS LEARNT: Over a period of 3 years, the HIA-CHU laboratory improved its SLIPTA score by 29% through a quality improvement process guided by work plan implementation, quality management system documentation, introduction of new proficiency testing and internal quality control programmes, and enhancement of personnel competencies in technical and quality management through training. RECOMMENDATIONS: The programme has yielded achievements, but consistent improvement efforts are necessary to address programme challenges and ensure continual increases in SLIPTA scores. Despite successes, military-specific challenges such as the high mobility of personnel have hindered programme progress. The authors recommend that further implementation research data be shared from programmes using SLIPTA in under-represented settings such as military health systems. |
|
Opinion Paper Maintaining routine HIV and tuberculosis testing services in sub-Saharan African countries in the context of COVID-19: Lessons learnt and opportunities for improvement Odhiambo, Collins O. Mataka, Anafi Loembe, Marguerite Massinga Ondoa, Pascale |
|
Original Research Involvement of CD95 and ligand in CD4+ T-cell and CD8+ T-cell depletion and hepatic cytolysis in patients with chronic viral hepatitis B Agueguia, Franklin S. Azebaze Talla, Paul Assoumou, Marie C. Okomo Jacobs, Graeme B. Mbakam, Cedric H. Guiedem, Elise Mesembe, Martha Tongo Lyonga, Emilia Ikomey, George Mondinde Abstract in English: BACKGROUND: Chronic viral hepatitis B (HBV) is characterised by progressive hepatocyte destruction and T-cell depletion. The mechanisms of the CD95-CD95 ligand (CD95L) signalling pathway during this chronic disease and the cirrhotic process remains unclear. OBJECTIVE: We evaluated the involvement of the CD95-CD95L receptor-ligand system in T-cell depletion and hepatic cytolysis in patients with chronic HBV. METHODS: This was a cross-sectional study conducted from September to December 2018 at the Yaoundé General Hospital, Cameroon. Four mL of whole blood was collected and analysed. The CD95 and CD95L levels, as well as the CD4+ T-cell and CD8+ T-cell counts, were performed by enzyme-linked immunosorbent assay and flow cytometry. RESULTS: Of the 130 HBV-positive patients, 36 (27.7%) were cirrhotic and 94 (72.3%) were non-cirrhotic. The cirrhotic patients had significantly elevated CD95 (p < 0.001) and CD95L (p = 0.001) plasma levels, compared with non-cirrhotic patients. The CD4/CD8 ratios were lower in cirrhotic patients, compared to non-cirrhotic patients (p < 0.001). There were statistically significant correlations between CD95 level and CD4+ T-cell counts, between CD95 level and CD8+ T-cell counts, between CD95 level and the CD4/CD8 ratio, between CD95 level and fibrosis score, and between CD95L level and fibrosis score. CONCLUSION: CD95 and CD95L could be involved in T-cell depletion and hepatic cytolysis during the pathogenesis of chronic HBV and could potentially be used as biomarkers for immunological and hepatic monitoring in patients with chronic HBV. |
|
Original Research Multicentre study of the burden of multidrug-resistant bacteria in the aetiology of infected diabetic foot ulcers Adeyemo, Adeyemi T. Kolawole, Babatope Rotimi, Vincent O. Aboderin, Aaron O. Abstract in English: BACKGROUND: Infected diabetic foot ulcer (IDFU) is a public health issue and the leading cause of non-traumatic limb amputation. Very few published data on IDFU exist in most West African countriesOBJECTIVE: The study investigated the aetiology and antibacterial drug resistance burden of IDFU in tertiary hospitals in Osun state, Nigeria, between July 2016 and April 2017METHODS: Isolates were cultured from tissue biopsies or aspirates collected from patients with IDFU. Bacterial identification, antibiotic susceptibility testing and phenotypic detection of extended-spectrum beta-lactamase and carbapenemase production were done by established protocols. Specific resistance genes were detected by polymerase chain reactionRESULTS: There were 218 microorganisms isolated from 93 IDFUs, comprising 129 (59.2%) Gram-negative bacilli (GNB), 59 (27.1%) Gram-positive cocci and 29 (13.3%) anaerobic bacteria. The top five facultative anaerobic bacteria isolated were: Staphylococcus aureus (34; 15.6%), Escherichia coli (23; 10.6%), Pseudomonas aeruginosa (20; 9.2%), Klebsiella pneumoniae (19; 8.7%) and Citrobacter spp. (19; 8.7%). The most common anaerobes were Bacteroides spp. (7; 3.2%) and Peptostreptococcus anaerobius (6; 2.8%). Seventy-four IDFUs (80%) were infected by multidrug-resistant bacteria, predominantly methicillin-resistant S. aureus and GNB producing extended-spectrum β-lactamases, mainly of the CTX-M variety. Only 4 (3.1%) GNB produced carbapenemases encoded predominantly by blaVIM. Factors associated with presence of multidrug-resistant bacteria were peripheral neuropathy (adjusted odds ratio [AOR] = 4.05, p = 0.04) and duration of foot infection of more than 1 month (AOR = 7.63, p = 0.02CONCLUSION: Multidrug-resistant facultative anaerobic bacteria are overrepresented as agents of IDFU. A relatively low proportion of the aetiological agents were anaerobic bacteria |
|
Editorial Call for emergency action to limit global temperature increases, restore biodiversity, and protect health Atwoli, Lukoye Baqui, Abdullah H. Benfield, Thomas Bosurgi, Raffaella Godlee, Fiona Hancocks, Stephen Horton, Richard Laybourn-Langton, Laurie Monteiro, Carlos Augusto Norman, Ian Patrick, Kirsten Praities, Nigel Rikkert, Marcel G.M. Olde Rubin, Eric J. Sahni, Peush Smith, Richard Talley, Nicholas J. Turale, Sue Vázquez, Damián |
|
Opinion Paper Impact of COVID-19 on blood donation and supply in Africa David, Kenneth B. Simfukwe, Knovicks Musa, Mohamed B. Munharo, Steven Lucero-Prisno III, Don E. |
|
Original Research In-depth investigation of turn-around time of full blood count tests requested from a clinical haematology outpatient department in Cape Town, South Africa Mutema, Leonard Chapanduka, Zivanai Musaigwa, Fungai Mashigo, Nomusa Abstract in English: BACKGROUND: The performance of laboratories can be objectively assessed using the overall turn-around time (TAT). However, TAT is defined differently by the laboratory and clinicians; therefore, it is important to determine the contribution of all the different components making up the laboratory test cycleOBJECTIVE: We carried out a retrospective analysis of the TAT of full blood count tests requested from the haematology outpatient department at Tygerberg Academic Hospital in Cape Town, South Africa, with an aim to assess laboratory performance and to identify critical steps influencing TATMETHODS: A retrospective audit was carried out, focused on the full blood count tests from the haematology outpatient department within a period of 3 months between 01 February and 30 April 2018. Data was extracted from the National Health Laboratory Service laboratory information system. The time intervals of all the phases of the test cycle were determined and total TAT and within-laboratory (intra-lab) TAT were calculatedRESULTS: A total of 1176 tests were analysed. The total TAT median was 275 (interquartile range [IQR] 200.0-1537.7) min with the most prolonged phase being from authorisation to review by clinicians (median 114 min; IQR: 37.0-1338.5 min). The median intra-lab TAT was 55 (IQR 40-81) min and 90% of the samples were processed in the laboratory within 134 min of registrationCONCLUSION: Our findings showed that the intra-lab TAT was within the set internal benchmark of 3 h. Operational phases that were independent of the laboratory processes contributed the most to total TAT |
|
Original Research Higher proportion of non-classical and intermediate monocytes in newly diagnosed multiple myeloma patients in Egypt: A possible prognostic marker Zahran, Asmaa M. Nafady-Hego, Hanaa Moeen, Sawsan M. Eltyb, Hanan A. Wahman, Mohammed M. Nafady, Asmaa Abstract in English: BACKGROUND: Interaction between multiple myeloma (MM) cells and proximal monocytes is expected during plasma cell proliferation. However, the role of monocyte subsets in the disease progression is unknownOBJECTIVE: This study evaluated circulating monocyte populations in MM patients and their correlation with disease severityMETHODS: Peripheral monocytes from 20 patients with MM attending Assiut University Hospital in Assiut, Egypt, between October 2018 and August 2019 were processed using a flow cytometry procedure and stratified using the intensity of expression of CD14 and CD16 into classical (CD16−CD14++), intermediate (CD16+CD14++), and non-classical (CD16++CD14+) subsets. The data were compared with data from 20 healthy control participants with comparable age and sexRESULTS: In patients with MM, the percentage of classical monocytes was significantly lower (mean ± standard error: 77.24 ± 0.66 vs 83.75 ± 0.5), while those of non-classical (12.44 ± 0.5 vs 8.9 ± 0.34) and intermediate (10.3 ± 0.24 vs 7.4 ± 0.29) monocytes were significantly higher when compared with those of controls (all p < 0.0001). Proportions of non-classical and intermediate monocytes correlated positively with serum levels of plasma cells, M-protein, calcium, creatinine and lactate dehydrogenase, and correlated negatively with the serum albumin level. Proportions of classical monocytes correlated positively with albumin level and negatively correlated with serum levels of M-protein, plasma cells, calcium, creatinine, and lactate dehydrogenaseCONCLUSION: Circulating monocyte subpopulations are skewed towards non-classical and intermediate monocytes in MM patients, and the intensity of this skewness increases with disease severity |
|
Original Research Effects of TNF-α and IL-10-819 T>C single nucleotide polymorphisms on urogenital schistosomiasis in preschool children in Zimbabwe Marume, Amos Chimponda, Theresa Vengesai, Arthur Mushayi, Caroline Mann, Jaclyn Mduluza, Takafira Abstract in English: BACKGROUND: Knowledge gaps exist between host genetic factors and susceptibility to schistosomiasisOBJECTIVE: This study determined cytokine levels and single nucleotide polymorphisms of tumour necrosis factor (TNF)-α (rs1800629) and interleukin (IL)-10 (rs1800871) and their possible impact on susceptibility to schistosomiasis in preschool-age children in the Madziva area of Shamva district, Mashonaland Central province, ZimbabweMETHODS: Urogenital schistosomiasis was diagnosed using the urine filtration method, while a sandwich enzyme-linked immunosorbent assay was used for cytokine level determination. The survey was done in August 2015 and reinfection levels post treatment were assessed at 3, 6 and 12 months. Amplification refractory mutation system polymerase chain reaction with visualisation on 2% agarose gel electrophoresis was used for genotypingRESULTS: Schistosomiasis prevalence was found to be 10.5% (59/563). Reinfections were detected in only six children at 3 months and only one was reinfected at 12 months. There were no significant differences in TNF-α-308 G/A allele or genotype frequencies between the Schistosoma haematobium infected participants (p = 0.360) and uninfected participants (p = 0.279). However, no children with the IL-10-819 TT genotype had schistosomiasis. The TNF-α GG genotype corresponded with significantly lower TNF-α levels when compared with the GA or AA genotypes (p < 0.001), and TNF-α levels were significantly lower in infected children compared to uninfected children (p < 0.001CONCLUSION: Higher TNF-α levels and lower IL-10 levels are potentially protective against schistosomiasis infection. The IL-10-819 TT genotype is potentially protective against infection through its association with lower IL-10 levels |
|
Lessons from the Field The deployment of mobile diagnostic laboratories for Ebola virus disease diagnostics in Sierra Leone and Guinea Presser, Lance D. Coffin, Jeanette Koivogui, Lamine Campbell, Allan Campbell, Julian Barrie, Fatmata Ngobeh, Jone Souma, Zein Sorie, Samuel Harding, Doris Camara, Alimou Tohonamou, Pepe Traore, Basala Hamill, Frank A. Bogan, Joe Altmann, Sharon Ross, Casey Mansheim, Jay Hegerty, Robert Poynter, Scott Shearrer, Scott Asbun, Carmen Karlstrand, Brendan Davis, Phil Alam, Jane Roberts, David Stamper, Paul D. Ndjomou, Jean Wauquier, Nadia Koroma, Mohamed Munu, Alhaji McClintock, Jason Mar, Mar Burns, True Krcha, Stephen Abstract in English: BACKGROUND: Ebola virus emerged in West Africa in December 2013. The ease of mobility, porous borders, and lack of public health infrastructure led to the largest Ebola virus disease (EVD) outbreak to dateINTERVENTION: The 2013 EVD outbreak signalled the need for laboratory diagnostic capabilities in areas without strong public health systems. As part of the United States' Department of Defense response, MRIGlobal was contracted to design, fabricate, equip, deploy, and operate two mobile diagnostic laboratories (MDLs). The first laboratory analysed blood samples from patients in an adjacent Ebola Treatment Centre (ETC) and buccal swabs from the deceased in the community in Moyamba, Sierra Leone. The second laboratory was deployed to support an ETC in Conakry, Guinea. The Department of Defense provided real-time quantitative reverse transcription polymerase chain reaction assays that were deployed and validated on-siteLESSONS LEARNT: Prompt and accurate molecular diagnostics reduced sample turn-around times from over 24 h to under 4 h. Experienced laboratory staff tested up to 110 samples per day and on-site engineering proved necessary for MDL setup and operation. As the Ebola response slowed, the sustainment of the MDLs' operations was prioritised, including staff training and the transition of the MDLs to local governments. Training programmes for local staff were prepared in Sierra Leone and GuineaRECOMMENDATIONS: The MRIGlobal MDL team significantly contributed to establishing increased laboratory capacity during the EVD outbreak in West Africa. Using the MDLs for molecular diagnosis is highly recommended until more sustainable solutions can be provided |
|
Brief Report Cross-validation of a high-performance liquid chromatography nevirapine plasma assay in a resource-limited setting in Zimbabwe Makita-Chingombe, Faithful Podany, Anthony T. Mykris, Timothy Muzambi, Farai Browne, Richard W. Ocque, Andrew J. DiFrancesco, Robin Winchester, Lee C. Fletcher, Courtney V. Mudzviti, Tinashe Maponga, Charles C. Morse, Gene D. Abstract in English: An international HIV pharmacology specialty laboratory (PSL) was established at the University of Zimbabwe to increase bioanalytical and investigator capacities. Quantitation of plasma nevirapine in samples from the AIDS Clinical Trials Group protocol 5279 was compared between the University of Nebraska Medical Center PSL and the University of Zimbabwe PSL. Both PSLs employed internally developed methods utilising reverse-phase high-performance liquid chromatography with ultraviolet detection. Eighty-seven percent of the cross-validation results exhibited ± 20% difference. |
|
Lessons from the Field Adaptation of an electronic dashboard to monitor HIV viral load testing in Côte d'Ivoire Kirk, Mary Assoa, Paul H. Iiams-Hauser, Casey Kouabenan, Yves-Rolland Antilla, Jennifer Steele-Lane, Caleb Rossum, Greg Komena, Pascal Ngatchou, Patricia Sadate Abiola, Nadine Kouakou, Alain Pongathie, Adama Koffi, Jean B. Adje, Christiane Perrone, Lucy A. Abstract in English: BACKGROUND: The Ministère de le Santé et de l'Hygiène Publique in Côte d'Ivoire and the international community have invested in health information systems in Côte d'Ivoire since 2009, including electronic laboratory information systems. These systems have been implemented in more than 80 laboratories to date and capture all test results produced from these laboratories, including HIV viral load (VL) testing. In 2018 the national HIV programme in Côte d'Ivoire requested international support to develop real-time tools such as dashboards to aggregate and display test-specific data such as HIV VL testing to support the country's programmatic response to HIVINTERVENTION: The VL dashboard was adapted in 2018 using source software code obtained from the Kenyan Ministry of Health and modified for the Ivorian context. The dashboard enables users to assess relevant clinical data from all Ivoirians living with HIV who undergo VL testing through dashboard data visualisations, including the number of VL tests, kinds of samples tested, and VL levels stratified by demographics and geographic locationLESSONS LEARNT: The VL dashboard enables rapid analysis of VL testing data from across the country and enables the national HIV programme, donors and partners to respond rapidly to issues pertaining to access, turn-around times and othersRECOMMENDATIONS: Adapting existing open-source software is an effective and efficient way to implement transformative tools such as dashboards. The VL dashboard will likely be an essential tool for Côte d'Ivoire to meet the United Nations Programme on HIV/AIDS 90-90-90 targets |
|
Lessons from the Field Strategic site selection for placement of HIV early infant diagnosis point-of-care technology within a national diagnostic network in Lesotho Mataka, Anafi Tumbare, Esther A.J. Motsoane, Tsietso Holtzman, David Leqheka, Monkoe Phatsoane, Kolisang Sacks, Emma Isavwa, Anthony Tiam, Appolinaire Abstract in English: BACKGROUND: New technologies for rapid point-of-care (POC) diagnostic tests hold great potential for improving the health outcomes of HIV-exposed infants. POC testing for HIV early infant diagnosis (EID) was introduced in Lesotho in late 2016. Here we highlight critical requirements for selecting routine POC EID sites to ensure a sustainable and optimised EID diagnostic networkINTERVENTION: Lesotho introduced POC EID in a phased approach that included assessments of national databases to identify sites with high test volumes, the creation of local networks of sites to potentially increase access to POC EID, and a standardised capacity assessment to determine site readiness. Potential site networks comprising 'hub' testing sites and 'spoke' specimen referring sites were createdLESSONS LEARNT: After determining optimal placement, a total of 29 testing facilities were selected for placement of POC EID to potentially increase access to 189 facilities through the use of a hub-and-spoke model. Site capacity assessments identified vital human resources and infrastructure capacity gaps that needed to be addressed before introducing POC EID and informed appropriate POC platform selectionRECOMMENDATIONS: POC placement involves more than just purchasing the testing platforms. Considering the relatively small proportion of sites that can be eligible for placement of a POC platform, utilising a hub-and-spoke model can maximise the number of health facilities served by a POC platform while reducing the necessary capacity building and infrastructure investments to fewer sites |
|
Original Research Performance of International AIDS Vaccine Initiative African clinical research laboratories in standardised ELISpot and peripheral blood mononuclear cell processing in support of HIV vaccine clinical trials Langat, Robert K. Farah, Bashir Indangasi, Jackton Ogola, Simon Omosa-Manyonyi, Gloria Anzala, Omu Bizimana, Jean Tekirya, Emmanuel Ngetsa, Caroline Silwamba, Moses Muyanja, Enoch Chetty, Paramesh Jangano, Maureen Hills, Nancy Gilmour, Jill Dally, Len Cox, Josephine H. Hayes, Peter Abstract in English: BACKGROUND: Standardisation of procedures for performing cellular functional assays across laboratories participating in multicentre clinical trials is key for generating comparable and reliable data. OBJECTIVE: This article describes the performance of accredited laboratories in Africa and Europe on testing done in support of clinical trials. METHODS: For enzyme-linked immunospot assay (ELISpot) proficiency, characterised peripheral blood mononuclear cells (PBMCs) obtained from 48 HIV-negative blood donors in Johannesburg, South Africa, were sent to participating laboratories between February 2010 and February 2014. The PBMCs were tested for responses against cytomegalovirus, Epstein Barr and influenza peptide pools in a total of 1751 assays. In a separate study, a total of 1297 PBMC samples isolated from healthy HIV-negative participants in clinical trials of two prophylactic HIV vaccine candidates in Kenya, Uganda, Rwanda and Zambia were analysed for cell viability, cell yield and cell recovery from frozen PBMCs. RESULTS: Most (99%) of the 1751 ELISpot proficiency assays had data within acceptable ranges with low responses to mock stimuli. No significant statistical difference were observed in ELISpot responses at the five laboratories actively conducting immunological analyses. Of the 1297 clinical trial PBMCs processed, 94% had cell viability above 90% and 96% had cell yield above 0.7 million per mL of blood in freshly isolated cells. All parameters were within the predefined acceptance criteria. CONCLUSION: We demonstrate that multiple laboratories can generate reliable, accurate and comparable data by using standardised procedures, having regular training, having regular equipment maintenance and using centrally sourced reagents |
|
Original Research The growth patterns of the medical technology profession in South Africa Ellapen, Malcolm T. Ellapen, Terry J. Paul, Yvonne Abstract in English: BACKGROUND: Constant appraisal of healthcare workforce trends is vital; this measure determines the adequacy of the workforce in meeting its society's healthcare demands. This includes determining the number of the incoming workforce (students, interns) and the active or practising workforce relevant registriesOBJECTIVE: This study aimed to examine patterns of workforce growth in the medical technology profession (students, interns and practitioners) from 2008 to 2018 in South AfricaMETHODS: Student, intern and practitioner medical technology registries, from the 2012/2013, 2016/2017 and 2017/2018 Health Professions Council of South Africa (HPCSA) annual reports, were analysed. The number of National Health Laboratory Service and private laboratory posts were secured from the National Health Laboratory Service plan performance report. A comparison between the total number of South African medical technology (private and public) posts occupied versus the HPCSA practitioner 2016 register was completed, to determine the saturation statusRESULTS: Annual student, intern, and practitioner registries indicated a mean growth of 6.8%, 28.9%, and 0.7% from 2008 to 2018. The transition of interns to practitioners is progressively dwindling (2015-2018). The practitioner register showed a 1.2% decline in registration from 2013 until 2018. In 2016, only 55.9% of the HPCSA registered medical technologists were employed (p < 0.001CONCLUSION: There are more medical technologists than available public and private sector posts. The progressively growing student register compared to the dwindling practitioner register indicates attrition in the profession. An investigation identifying the reasons why graduates neglect to register as practising medical technologists should be undertaken |
|
Case Study Emphysematous pyelonephritis in an infant from Sokoto, north-western Nigeria Jiya, Fatima B. Ibitoye, Paul K. Jiya, Nma M. Amodu-Sanni, Maryam Mohammed, Yahaya Aquib, Dada M. Coker, Lukman K. Abstract in English: INTRODUCTION: Emphysematous pyelonephritis is a life-threatening necrotising bacterial infection of the kidneys. It is rare among children and can be fatal if not promptly identified and treatedCASE PRESENTATION: A 7-month-old male infant presented to the Emergency Paediatric Unit of Usmanu Danfodiyo University Teaching Hospital, Sokoto, Nigeria, on 12 November 2019 with a 5-day history of fever and vomiting, and a 3-day history of a progressively enlarging, left-side abdominal mass. There was associated excessive crying on micturition, refusal to feed and weight loss. He looked ill and was in respiratory distress, irritable, febrile (38.8 °C), moderately dehydrated and pale. His weight and length were 5.5 kg and 64 cm. He had a tender, firm and ballotable abdominal mass on the left flank measuring 8 cm × 10 cm. His pulse rate was 140 beats/min, blood pressure 60/40 millimetres of mercury and respiratory rate was 65 cycles/min. He had widespread coarse crepitations and normal heart sounds on chest auscultationMANAGEMENT AND OUTCOME: An initial diagnosis of sepsis was made. Other considerations were nephroblastoma and neuroblastoma. Ceftriaxone and blood transfusion were commenced with subsequent administration of intravenous fluids. Further radiologic investigations revealed emphysematous pyelonephritis. The patient had percutaneous drainage and extended spectrum β-lactamase-producing Escherichia coli (sensitive to meropenem) which was isolated from the aspirate culture after 48 h of incubation. Meropenem could not be commenced because of non-availability and high cost. The patient subsequently deteriorated and died from septic shock.CONCLUSION: Emphysematous pyelonephritis has a fulminant course when not diagnosed promptly and treated adequately |
|
Original Research Improving laboratory quality and capacity through leadership and management training: Lessons from Zambia 2016-2018 Gopolang, Felicity Zulu-Mwamba, Fales Nsama, Davy Kruuner, Annika Nsofwa, Dailes Kasvosve, Ishmael Gomo, Royce Motlhabane, Tiny Chohan, Bhavna Soge, Olusegun Osterhage, Daniel Campbell, Nancy Noble, Michael Downer, Ann Flandin, Jean-Frederic Nartker, Anya Koehn, Catherine Nonde, Linda K. Shibemba, Aaron Ndongmo, Clement B. Steinau, Martin Perrone, Lucy A. Abstract in English: BACKGROUND: Competent leadership and management are imperative for delivering quality laboratory services; however, few laboratory managers receive job-specific training in organisational management and leadershipOBJECTIVE: To develop and evaluate participants' competencies in organisational leadership and management as measured through learner and laboratory quality improvement assessmentsMETHODS: This professional development programme employed a mentored, blended learning approach, utilising in-person didactic and online training, with the practical application of a capstone project in the laboratories. Programme impact was evaluated through a series of pre- and post-laboartory assessments using the Stepwise Laboratory Improvement Process Towards Accreditation checklist, as well as learner-competency assessments through online quizzes and discussionsRESULTS: From 2016 to 2018, 31 managers and quality officers from 16 individual laboratories graduated from the programme having completed capstone projects addressing areas in the entire laboratory testing process. Laboratories increased their compliance with the International Organization for Standardization 15189 standard and all but two laboratories significantly increased their accreditation scores. Two laboratories gained three stars, two laboratories gained two stars, and five laboratories gained one star. Five laboratories subsequently achieved International Organization for Standardization 15189 accreditation in 2019CONCLUSION: This programme taught leadership theory to laboratory managers and allowed them to implement leadership and management practices in the laboratory setting. Programmes such as this complement existing laboratory quality management training programmes such as Strengthening Laboratory Management Toward Accreditation |
|
Brief Report Performance of TaqMan probes for the detection of sexually transmitted infections in South African women Mitchev, Nireshni Singh, Ravesh Garrett, Nigel Ramsuran, Veron Niehaus, Abraham J. Mlisana, Koleka P. Abstract in English: Neisseria gonorrhoeae, Chlamydia trachomatis, Trichomonas vaginalis and Mycoplasma genitalium are the four main aetiologies of sexually transmitted infections responsible for vaginal discharge syndrome (VDS). Commercially available multiplex polymerase chain reaction (PCR) assays are expensive and generally not customisable. We evaluated a highly customisable singleplex PCR approach by testing it in parallel with the Anyplex™ II STI-7 detection assay in a cohort of South African women that presented with VDS between May 2016 and January 2017. Our multiple singleplex PCR strategy proved to be a simple, accurate, rapid, affordable and scalable option for diagnosing VDS. |
|
Scientific Letter Biobanking of COVID-19 specimens during the pandemic: The need for enhanced biosafety Ilesanmi, Olayinka S. Afolabi, Aanuoluwapo A. |
Read our Open Access Statement
