Tabla de contenido
African Journal of Laboratory Medicine, Volumen: 6, Numero: 1, Publicado: 2017African Journal of Laboratory Medicine, Volumen: 6, Numero: 1, Publicado: 2017
| Documents |
|---|
|
Lessons from the Field Development and implementation of the Caribbean Laboratory Quality Management Systems Stepwise Improvement Process (LQMS-SIP) Towards Accreditation Alemnji, George Edghill, Lisa Guevara, Giselle Wallace-Sankarsingh, Sacha Albalak, Rachel Cognat, Sebastien Nkengasong, John Gabastou, Jean-Marc Resumen en Inglés: BACKGROUND: Implementing quality management systems and accrediting laboratories in the Caribbean has been a challenge. OBJECTIVES: We report the development of a stepwise process for quality systems improvement in the Caribbean Region. METHODS: The Caribbean Laboratory Stakeholders met under a joint Pan American Health Organization/US Centers for Disease Control and Prevention initiative and developed a user-friendly framework called 'Laboratory Quality Management System - Stepwise Improvement Process (LQMS-SIP) Towards Accreditation' to support countries in strengthening laboratory services through a stepwise approach toward fulfilling the ISO 15189: 2012 requirements. RESULTS: This approach consists of a three-tiered framework. Tier 1 represents the minimum requirements corresponding to the mandatory criteria for obtaining a licence from the Ministry of Health of the participating country. The next two tiers are quality improvement milestones that are achieved through the implementation of specific quality management system requirements. Laboratories that meet the requirements of the three tiers will be encouraged to apply for accreditation. The Caribbean Regional Organisation for Standards and Quality hosts the LQMS-SIP Secretariat and will work with countries, including the Ministry of Health and stakeholders, including laboratory staff, to coordinate and implement LQMS-SIP activities. The Caribbean Public Health Agency will coordinate and advocate for the LQMS-SIP implementation. CONCLUSION: This article presents the Caribbean LQMS-SIP framework and describes how it will be implemented among various countries in the region to achieve quality improvement. |
|
Original Research Task-shifting point-of-care CD4+ testing to lay health workers in HIV care and treatment services in Namibia Kaindjee-Tjituka, Francina Sawadogo, Souleymane Mutandi, Graham Maher, Andrew D. Salomo, Natanael Mbapaha, Claudia Neo, Marytha Beukes, Anita Gweshe, Justice Muadinohamba, Alexinah Lowrance, David W. Resumen en Inglés: INTRODUCTION: Access to CD4+ testing remains a common barrier to early initiation of antiretroviral therapy among persons living with HIV/AIDS in low- and middle-income countries. The feasibility of task-shifting of point-of-care (POC) CD4+ testing to lay health workers in Namibia has not been evaluated METHODS: From July to August 2011, Pima CD4+ analysers were used to improve access to CD4+ testing at 10 selected public health facilities in Namibia. POC Pima CD4+ testing was performed by nurses or lay health workers. Venous blood samples were collected from 10% of patients and sent to centralised laboratories for CD4+ testing with standard methods. Outcomes for POC Pima CD4+ testing and patient receipt of results were compared between nurses and lay health workers and between the POC method and standard laboratory CD4+ testing methods RESULTS: Overall, 1429 patients received a Pima CD4+ test; 500 (35.0%) tests were performed by nurses and 929 (65.0%) were performed by lay health workers. When Pima CD4+ testing was performed by a nurse or a lay health worker, 93.2% and 95.2% of results were valid (p = 0.1); 95.6% and 98.1% of results were received by the patient (p = 0.007); 96.2% and 94.0% of results were received by the patient on the same day (p = 0.08). Overall, 97.2% of Pima CD4+ results were received by patients, compared to 55.4% of standard laboratory CD4+ results (p < 0.001 CONCLUSIONS: POC CD4+ testing was feasible and effective when task-shifted to lay health workers. Rollout of POC CD4+ testing via task-shifting can improve access to CD4+ testing and retention in care between HIV diagnosis and antiretroviral therapy initiation in low- and middle-income countries |
|
Original Research Trends in leprosy case detection in Rwanda, 1995-2011: analysis of 17 years of laboratory data Uwimana, Innocent Bizimungu, Nestor Ingabire, Fabrice Mukamukwiye, Elyse Sharangabo, Odette Ngabonziza, Semuto C. Kamanzi, Elaine Resumen en Inglés: BACKGROUND: Leprosy, or Hansen's disease, is a chronic, infectious disease caused by Mycobacterium leprae. It remains one of the leading causes of deformity and physical disability. OBJECTIVE: We analysed laboratory records to assess trends in prevalence rates and case detection rates (CDRs) in Rwanda. METHODS: A retrospective review of detected leprosy cases from the records of the Rwanda National Reference Laboratory over a 17-year period (1995-2011) was conducted. Skin biopsy samples were analysed microscopically using Ziehl-Neelsen staining technique to identify M. leprae. RESULTS: Cumulatively, 266 suspected cases were reported between 1995 and 2011. Of the suspected cases, 77 (28.9%) were laboratory confirmed as having leprosy. Among detected cases, 59 (76.6%) were men and 18 (23.4%) women. :female ratio was 3:1. There were 77 registered leprosy cases over the 17-year period of the study, and the prevalence rate was 0.005 per 10 000 population. A gradual decrease in the prevalence rate was observed from 0.015 per 10 000 population in 2003 to 0.003 per 10 000 population in 2010. From 1995 to 2011, the CDR did not exceed one per 10 000 population. CONCLUSION: This laboratory review demonstrates a declining trend in prevalence rates and CDR during the period of the study. Early case detection and a sustainable leprosy control programme remain the cornerstones of reducing the physical and socio-economic burden of leprosy in Rwanda. |
|
Brief Report Failure of BACTEC™ MGIT 960™ to detect Mycobacterium tuberculosis complex within a 42-day incubation period Mahomed, Sharana Dlamini-Mvelase, Nomonde R. Dlamini, Moses Mlisana, Koleka Resumen en Inglés: For the optimal recovery of Mycobacterium tuberculosis from the BACTEC™ Mycobacterium Growth Indicator Tube 960™ system, an incubation period of 42-56 days is recommended by the manufacturer. Due to logistical reasons, it is common practice to follow an incubation period of 42 days. We undertook a retrospective study to document positive Mycobacterium Growth Indicator Tube cultures beyond the 42-day incubation period. In total, 98/110 (89%) were positive for M. tuberculosis complex. This alerted us to M. tuberculosis growth detection failure at 42 days. |
|
Lessons from the Field Implementing SLMTA in the Kenya national blood transfusion service: lessons learned Wakaria, Eric N. Rombo, Charles O. Oduor, Margaret Kambale, Serah M. Tilock, Kimberly Kimani, Daniel Makokha, Ernest Mwamba, Peter M. Mwangi, Jane Resumen en Inglés: BACKGROUND: The Kenya National Blood Transfusion Service (KNBTS) is mandated to provide safe and sufficient blood and blood components for the country. In 2013, the KNBTS National Testing Laboratory and the six regional blood transfusion centres were enrolled in the Strengthening Laboratory Management Toward Accreditation (SLMTA) programme. The process was supported by Global Communities with funding from the United States Centers for Disease Control and Prevention. METHODS: The SLMTA implementation at KNBTS followed the standard three-workshop series, on-site mentorships and audits. Baseline, midterm and exit audits were conducted at the seven facilities, using a standard checklist to measure progress. Given that SLMTA was designed for clinical and public health laboratories, key stakeholders, guided by Global Communities, tailored SLMTA materials to address blood transfusion services, and oriented trainers, auditors and mentors on the same. RESULTS: The seven facilities moved from an average of zero stars at baseline to an average of three stars at the exit audit. The average baseline audit score was 38% (97 points), midterm 71% (183 points) and exit audit 79% (205 points). The Occurrence Management and Process Improvement quality system essential had the largest improvement (at 67 percentage points), from baseline to exit, whereas Facilities and Safety had the smallest improvement (at 31 percentage points). CONCLUSION: SLMTA can be an effective tool for preparing a blood transfusion service for accreditation. Key success factors included customising SLMTA to blood transfusion activities; sensitising trainers, mentors and auditors on operations of blood transfusion service; creating SLMTA champions in key departments; and integrating other blood transfusion-specific accreditation standards into SLMTA. |
|
Original Research National laboratory policies and plans in sub-Saharan African countries: gaps and opportunities Ondoa, Pascale van der Broek, Ankie Jansen, Christel de Bruijn, Hilde Schultsz, Constance Resumen en Inglés: BACKGROUND: The 2008 Maputo Declaration calls for the development of dedicated national laboratory policies and strategic plans supporting the enhancement of laboratory services in response to the long-lasting relegation of medical laboratory systems in sub-Saharan Africa OBJECTIVES: This study describes the extent to which laboratories are addressed in the national health policies and plans created directly following the 2008 momentum for laboratory strengthening METHOD: National health policies and plans from 39 sub-Saharan African countries, valid throughout and beyond 31 December 2010 were collected in March 2012 and analysed during 2013 RESULTS: Laboratories were addressed by all countries. Human resources were the most addressed topic (38/39) and finances and budget were the least addressed (< 5/39). Countries lagging behind in national laboratory strategic planning at the end of 2013 (17/39) were more likely to be francophone countries located in West-Central Africa (13/17) and have historically low HIV prevalence. The most common gaps anticipated to compromise the implementation of the policies and plans were the disconnect between policies and plans, under-developed finance sections and monitoring and evaluating frameworks, absence of points of reference to define gaps and shortages, and inappropriate governance structure CONCLUSION: The availability of laboratory policy and plan implementation can be improved by strictly applying a more standardised methodology for policy development, using harmonised norms to set targets for improvement and intensifying the establishment of directorates of laboratory services directly under the authority of Ministries of Health. Horizontal programmes such as the Global Health Security Agenda could provide the necessary impulse to take the least advanced countries on board |
|
Original Research Development of a real-time PCR assay and comparison to CHROMagarTM STEC to screen for Shiga toxin-producing Escherichia coli in stool, Cape Town, South Africa Kalule, John B. Keddy, Karen H. Smith, Anthony Nicol, Mark P. Robberts, Lourens Resumen en Inglés: INTRODUCTION: Shiga toxin-producing Escherichia coli (STEC) is an emerging infectious pathogen which could lead to haemolytic uremic syndrome. Even though previous studies have compared the performance of CHROMagarTMSTEC to real-time polymerase chain reaction (PCR) in Europe, no study has been done to assess its performance on African isolates OBJECTIVES: This project aimed to validate and test an in-house-developed duplex real-time PCR and use it as a reference standard to determine the performance of CHROMagarTMSTEC on African isolates from diarrhoeic stool samples METHODS: This study evaluated STEC diagnostic technology on African isolates. An in-house-developed duplex real-time PCR assay for detection of stx1 and stx2 was validated and tested on diarrhoeic stool samples and then used as a reference standard to assess the performance of CHROMagarTMSTEC. Real-time PCR was used to screen for stx in tryptic soy broth and the suspected STEC isolates, while conventional PCR was used to detect the other virulence genes possessed by the isolates RESULTS: The real-time PCR limit of detection was 5.3 target copies/μL of broth. The mean melting temperature on melt-curve analysis for detection of stx1 was 58.2 °C and for stx2 was 65.3 °C. Of 226 specimens screened, real-time PCR detected stx in 14 specimens (6.2%, 95% confidence interval = 3.43% - 10.18%). The sensitivity, specificity, negative predictive value and positive predictive value of the CHROMagarTMSTEC were 33.3%, 77.4%, 95.3% and 11.3% CONCLUSIONS: The in-house developed real-time PCR assay is a sensitive and specific option for laboratory detection of STEC as compared to CHROMagarTMSTEC in this setting |
|
Case studies Cylindrocarpon lichenicola keratomycosis in Nigeria: the challenge of limited access to effective antimicrobials Irek, Emmanuel O. Obadare, Temitope O. Udonwa, Patrick A. Laoye, Olajumoke Abiri, Oyekola V. Adeoye, Adenike O. Aboderin, Aaron O. Resumen en Inglés: INTRODUCTION: We report a rare cause of keratitis, due to Cylindrocarpon lichenicola, in a farmer with keratomycosis. Despite the acknowledged virulence of this fungus, a suitable antifungal for its management was not accessible CASE PRESENTATION: A 67-year-old farmer presented with a two-week history of pain, mucopurulent discharge, redness and a corneal ulcer with a visual acuity of hand movement in the right eye. With a working diagnosis of infective keratitis, corneal scrapings were taken under a slit lamp biomicroscope for microbiological testing. Direct lactophenol cotton blue mounts revealed septate fungal hyphae, while fungal culture on Sabouraud dextrose agar at room temperature grew woolly mould phenotypically consistent with C. lichenicola MANAGEMENT AND OUTCOME: The patient was started on hourly topical natamycin (5%), ciprofloxacin (0.3%), two-hourly instillation of tobramycin (0.3%) and atropine (1%) twice daily for three months following the isolation of the fungus. The eye healed with a corneal scar and no improvements in visual acuity. DISCUSSION: This infection was difficult to manage due to the inaccessibility of a suitable antifungal, namely, voriconazole in our setting. Hence, there is a need for prompt identification and early institution of suitable antifungals in any patient with suspected keratomycosis |
|
Original Research Point-of-care diagnosis and risk factors of infantile, rotavirus-associated diarrhoea in Calabar, Nigeria Nnukwu, Samuel E. Utsalo, Simon J. Oyero, Olufunmilayo G. Ntemgwa, Michel Ayukekbong, James A. Resumen en Inglés: BACKGROUND: Rotaviruses are the primary cause of acute gastroenteritis in young children worldwide and a significant proportion of these infections occur in Africa OBJECTIVES: In the present study, we determined the prevalence and risk factors of rotavirus infection among children younger than age 5 years with or without diarrhoea in Calabar, Nigeria, using a rapid point-of-care test METHODS: Two hundred infants younger than age 5 years presenting with acute gastroenteritis and a control group of 200 infants without diarrhoea were tested for rotavirus. Each stool sample was homogenised in an extraction buffer and the supernatant added into the sample well of the Rida Quick rotavirus test cassette and allowed to run for 5 minutes at room temperature. When both the control band and test band were visible on the test cassette a positive result was recorded, whereas when only the control band was visible a negative results was recorded RESULTS: Rotavirus was detected in 25 (12.5%) of children with diarrhoea and in no children without diarrhoea. Our results demonstrated that children who were exclusively breast-fed by their mothers were not infected with rotavirus and that 92% of the infants infected with rotavirus experienced vomiting CONCLUSION: These data demonstrate that asymptomatic rotavirus infection is rare and that rotavirus is commonly detected in stool samples of children suffering from diarrhoea with concomitant vomiting. Use of point-of-care rotavirus tests will enhance early diagnosis of rotavirus-associated diarrhoea and reduce irrational use of antibiotics |
|
Original Research Use of matrix-assisted laser desorption/ionisation-time of flight mass spectrometry analyser in a diagnostic microbiology laboratory in a developing country Bulane, Atang Hoosen, Anwar Resumen en Inglés: BACKGROUND: Rapid and accurate identification of pathogens is of utmost importance for management of patients. Current identification relies on conventional phenotypic methods which are time consuming. Matrix-assisted laser desorption/ionisation-time of flight mass spectrometry (MALDI-TOF MS) is based on proteomic profiling and allows for rapid identification of pathogens OBJECTIVE: We compared MALDI-TOF MS against two commercial systems, MicroScan Walkaway and VITEK 2 MS METHODS: Over a three-month period from July 2013 to September 2013, a total of 227 bacteria and yeasts were collected from an academic microbiology laboratory (N = 121; 87 Gram-negatives, seven Gram-positives, 27 yeasts) and other laboratories (N = 106; 35 Gram-negatives, 34 Gram-positives, 37 yeasts). Sixty-five positive blood cultures were initially processed with Bruker Sepsityper kit for direct identification RESULTS: From the 65 blood culture bottles, four grew more than one bacterial pathogen and MALDI-TOF MS identified only one isolate. The blood cultures yielded 21 Gram-negatives, 43 Gram-positives and one Candida. There were 21 Escherirchia coli isolates which were reported by the MALDI-TOF MS as E. coli/Shigella. Of the total 292 isolates, discrepant results were found for one bacterial and three yeast isolates. Discrepant results were resolved by testing with the API system with MALDI-TOF MS showing 100% correlation CONCLUSION: The MALDI-TOF MS proved to be very useful for rapid and reliable identification of bacteria and yeasts directly from blood cultures and after culture of other specimens. The difference in time to identification was significant for all isolates. However, for positive blood cultures with minimal sample preparation time there was a massive difference in turn-around time with great appreciation by clinicians |
|
Corrections Corrigendum: Assuring the quality of diagnostic testing: the future is now Nkengasong, John Boeras, Debrah I. Abimiku, Alash'le Peeling, Rosanna W. |
|
Original Research Performance evaluation of tuberculosis smear microscopists working at rechecking laboratories in Ethiopia Asrat, Habtamu Kebede, Abebaw Abebe, Abnet Meaza, Abyot Hailu, Getinet Desale, Adinew Gashu, Andargachew Kassa, Wondwossen Mekonnen, Tesfaye Abose, Ebisea Girmachew, Feven Yenealem1, Dereje Mulugeta, Achamyeleh Ayana, Gonfa Desta, Kassu Resumen en Inglés: BACKGROUND: Tuberculosis is an infectious disease caused by the bacillus Mycobacterium tuberculosis. According to the Ethiopian Federal Ministry of Health's 2013-2014 report, the tuberculosis case detection rate was 53.7%, which was below the target of 81% set for that year. OBJECTIVE: This study assessed the performance of tuberculosis smear microscopists at external quality assessment rechecking laboratories in Ethiopia. METHODS: A cross-sectional study was conducted at 81 laboratories from April to July 2015. Panel slides were prepared and validated at the National Tuberculosis Reference Laboratory. The validated panel slides were used to evaluate the performance of microscopists at these laboratories compared with readers from the reference laboratory. RESULTS: A total of 389 external quality assessment rechecking laboratory microscopists participated in the study, of which 268 (68.9%) worked at hospitals, 241 (62%) had more than five years of work experience, 201 (51.7%) held Bachelors degrees, and 319 (82%) reported tuberculosis smear microscopy training. Overall, 324 (83.3%) participants scored ≥ 80%. Sensitivity for detecting tuberculosis bacilli was 84.5% and specificity was 93.1%. The overall percent agreement between participants and reference readers was 87.1 (kappa=0.72). All 10 slides were correctly read (i.e., scored 100%) by 80 (20.6%) participants, 156 (40.1%) scored 90% - 95%, 88 (22.6%) scored 80% - 85% and 65 (16.7%) scored below 80%. There were 806 (20.7%) total errors, with 143 (3.7%) major and 663 (17%) minor errors. CONCLUSION: The overall performance of participants in reading the slides showed good agreement with the reference readers. Most errors were minor, and the ability to detect tuberculosis bacilli can be improved through building the capacity of professionals. |
|
Original Research Laboratory test result interpretation for primary care doctors in South Africa Vanker, Naadira Faull, Norman H. B. Resumen en Inglés: BACKGROUND: Challenges and uncertainties with test result interpretation can lead to diagnostic errors. Primary care doctors are at a higher risk than specialists of making these errors, due to the range in complexity and severity of conditions that they encounter. OBJECTIVES: This study aimed to investigate the challenges that primary care doctors face with test result interpretation, and to identify potential countermeasures to address these METHODS: A survey was sent out to 7800 primary care doctors in South Africa. Questionnaire themes included doctors' uncertainty with interpreting test results, mechanisms used to overcome this uncertainty, challenges with appropriate result interpretation, and perceived solutions for interpreting results. RESULTS: Of the 552 responses received, the prevalence of challenges with result interpretation was estimated in an average of 17% of diagnostic encounters. The most commonly-reported challenges were not receiving test results in a timely manner (51% of respondents) and previous results not being easily available (37%). When faced with diagnostic uncertainty, 84% of respondents would either follow-up and reassess the patient or discuss the case with a specialist, and 67% would contact a laboratory professional. The most useful test utilisation enablers were found to be: interpretive comments (78% of respondents), published guidelines (74%), and a dedicated laboratory phone line (72%). CONCLUSION: Primary care doctors acknowledge uncertainty with test result interpretation. Potential countermeasures include the addition of patient-specific interpretive comments, the availability of guidelines or algorithms, and a dedicated laboratory phone line. The benefit of enhanced test result interpretation would reduce diagnostic error rates. |
|
Lessons from the Field Implementation of broad screening with Ebola rapid diagnostic tests in Forécariah, Guinea Louis, Frantz Jean Huang, Jennifer Y. Nebie, Yacouba K. Koivogui, Lamine Jayaraman, Gayatri Abiola, Nadine Vansteelandt, Amanda Worrel, Mary C. Shang, Judith Murphy, Louise B. Fitter, David L. Marston, Barbara J. Martel, Lise Resumen en Inglés: BACKGROUND: Laboratory-enhanced surveillance is critical for rapidly detecting the potential re-emergence of Ebola virus disease. Rapid diagnostic tests (RDT) for Ebola antigens could expand diagnostic capacity for Ebola virus disease. OBJECTIVES: The Guinean National Coordination for Ebola Response conducted a pilot implementation to determine the feasibility of broad screening of patients and corpses with the OraQuick® Ebola RDT. METHODS: The implementation team developed protocols and trained healthcare workers to screen patients and corpses in Forécariah prefecture, Guinea, from 15 October to 30 November 2015. Data collected included number of consultations, number of fevers reported or measured, number of tests performed for patients or corpses and results of confirmatory RT-PCR testing. Data on malaria RDT results were collected for comparison. Feedback from Ebola RDT users was collected informally during supervision visits and forums. RESULTS: There were 3738 consultations at the 15 selected healthcare facilities; 74.6% of consultations were for febrile illness. Among 2787 eligible febrile patients, 2633 were tested for malaria and 1628 OraQuick® Ebola RDTs were performed. A total of 322 OraQuick® Ebola RDTs were conducted on corpses. All Ebola tests on eligible patients were negative. CONCLUSIONS: Access to Ebola testing was expanded by the implementation of RDTs in an emergency situation. Feedback from Ebola RDT users and lessons learned will contribute to improving quality for RDT expansion. |
|
Original Research Creation and pilot testing of cases for case-based learning: A pedagogical approach for pathology cancer diagnosis Sayed, Shahin Lester, Susan C. Wilson, Michael Berney, Daniel Masia, Ricard Moloo, Zahir Stall, Jennifer Eslan, Alexia Ayers, Stephanie Mutuku, Angela Guarner, Jeannette Resumen en Inglés: BACKGROUND: Case-based learning (CBL) is an established pedagogical active learning method used in various disciplines and defined based on the field of study and type of case. The utility of CBL for teaching specific aspects of cancer diagnosis to practising pathologists has not been previously studied in sub-Saharan Africa OBJECTIVES: We aimed to pilot test standardised cancer cases on a group of practising pathologists in sub-Saharan Africa to evaluate case content, clarity of questions and delivery of content METHODS: Expert faculty created cases for the four most commonly diagnosed cancers. The format included mini-cases and bullet cases which were all open-ended. The questions dealt with interpretation of clinical information, gross specimen examination, morphologic characteristics of tumours, ancillary testing, reporting and appropriate communication to clinicians RESULTS: Cases on breast, cervical, prostate and colorectal cancers were tested on seven practising pathologists. Each case took an average of 45-90 min to complete Questions that were particularly challenging to testers were on: • Specimens they should have been but for some reason were not exposed to in routine practice. • Ancillary testing and appropriate tumour staging New knowledge gained included tumour grading and assessment of radial margins. Revisions to cases were made based on testers' feedback, which included rewording of questions to reduce ambiguity and adding of tables to clarify concepts. CONCLUSION: Cases were created for CBL in Kenya, but these are applicable elsewhere in Africa and beyond to teach cancer diagnosis. The pilot testing of cases prepared faculty for the actual CBL course and feedback provided by the testers assisted in improving the questions and impact on day-to-day practice |
|
Editorial Honing in on disease etiology Okeke, Iruka N. |
|
Editorial Africa CDC: Establishing Integrated Surveillance and Laboratory Networks for Rapid Disease Detection and Response, Control, Prevention, and Clinical Care in Africa Amukele, Timothy |
|
Original Research Programmatic implications of implementing the relational algebraic capacitated location (RACL) algorithm outcomes on the allocation of laboratory sites, test volumes, platform distribution and space requirements Cassim, Naseem Smith, Honora Coetzee, Lindi M. Glencross, Deborah K. Resumen en Inglés: INTRODUCTION: CD4 testing in South Africa is based on an integrated tiered service delivery model that matches testing demand with capacity. The National Health Laboratory Service has predominantly implemented laboratory-based CD4 testing. Coverage gaps, over-/under-capacitation and optimal placement of point-of-care (POC) testing sites need investigation. OBJECTIVES: We assessed the impact of relational algebraic capacitated location (RACL) algorithm outcomes on the allocation of laboratory and POC testing sites. METHODS: The RACL algorithm was developed to allocate laboratories and POC sites to ensure coverage using a set coverage approach for a defined travel time (T). The algorithm was repeated for three scenarios (A: T = 4; B: T = 3; C: T = 2 hours). Drive times for a representative sample of health facility clusters were used to approximate T. Outcomes included allocation of testing sites, Euclidian distances and test volumes. Additional analysis included platform distribution and space requirement assessment. Scenarios were reported as fusion table maps. RESULTS: Scenario A would offer a fully-centralised approach with 15 CD4 laboratories without any POC testing. A significant increase in volumes would result in a four-fold increase at busier laboratories. CD4 laboratories would increase to 41 in scenario B and 61 in scenario C. POC testing would be offered at two sites in scenario B and 20 sites in scenario C. CONCLUSION: The RACL algorithm provides an objective methodology to address coverage gaps through the allocation of CD4 laboratories and POC sites for a given T. The algorithm outcomes need to be assessed in the context of local conditions. |
|
Original Research Mother-to-child transmission of HIV and its predictors among HIV-exposed infants at Bamenda Regional Hospital, Cameroon Fondoh, Victor N. Mom, Njong A. Resumen en Inglés: BACKGROUND: Mother-to-child transmission (MTCT) of HIV, has been a major global public health burden. Despite the use of antiretroviral prophylaxis by HIV-positive pregnant women and their infants, safe obstetric practice and safe infant feeding habits in the prevention of MTCT of HIV, the prevalence of HIV among HIV-exposed infants is still high in Cameroon OBJECTIVE: Our objectives were to determine the prevalence, assess the predictors and determine the effect of combination antiretroviral therapy (cART) on MTCT of HIV at the regional hospital in Bamenda, Cameroon METHODS: This was a retrospective study. Secondary data from 877 HIV-exposed infants aged ≤ 72 weeks were extracted from the records between January 2008 and December 2014. The predictors and effect of cART on MTCT of HIV were analysed using a multivariable logistic regression model and risk analysis, respectively RESULTS: Out of 877 HIV-exposed infants, 62 were positive for HIV, giving a prevalence of 7.1%. Maternal antiretroviral intervention and infant age group were statistically significant predictors of MTCT of HIV. HIV-positive mothers who were on cART were 2.49 times less likely to transmit HIV than those who were not on cART CONCLUSION: In order to reduce the prevalence of HIV among HIV-exposed infants, maternal antiretroviral intervention should be targeted and the use of cART by HIV-positive pregnant women should be encouraged |
Lea la Declaración de Acceso abierto
