Open-access An audit of the iron status of patients at Chris Hani Baragwanath Academic Hospital, in Johannesburg, South Africa

Abstract

BACKGROUND: Iron deficiency is a common disorder, especially in developing countries. Accurately assessing iron status remains challenging, particularly for patients with chronic diseases such as HIV and chronic kidney disease, prevalent in South Africa. OBJECTIVE: This study aimed to determine how ferritin cut-offs affect iron status classification in adult patients treated at a tertiary hospital in South Africa. Additionally, it assessed the frequency of these conditions and the impact of age and gender on iron status METHODS: This retrospective study analysed iron profiles in adult patients from 01 October 2020 to 31 March 2021. Iron status was categorised into five groups: iron deficiency anaemia (IDA), anaemia of chronic disease, IDA with anaemia of chronic disease, iron deficiency without anaemia, and iron replete based on haemoglobin, transferrin saturation, and ferritin levels. The impact of using two different ferritin cut-off values (15 µg/L and 30 µg/L) was investigated. RESULTS: The study included 3221 complete iron profiles. There was a predominance of female patients (2.2:1 ratio). Anaemia of chronic disease was the most prevalent iron disorder (39%), regardless of ferritin cut-off. Using a higher ferritin cut-off of 30 µg/L significantly increased the detection rates of both IDA and iron deficiency without anaemia (p < 0.001). CONCLUSION: This study suggests that a higher ferritin threshold (30 µg/L) might improve diagnosis of iron disorders in settings with high inflammatory diseases. Further studies are needed to refine thresholds. Local guidelines should be adjusted to consider higher ferritin cut-offs, and longitudinal studies are recommended to evaluate long-term outcomes. WHAT THIS STUDY ADDS: This study confirms the use of higher ferritin cut-offs for enhanced detection of iron deficiency states. The findings also emphasise the ongoing need for establishing simple, standardised, and accurate methods for iron status classification.

Iron; iron status; ferritin; ferritin diagnostic threshold; iron deficiency; iron deficiency anaemia; anaemia of chronic disease


Introduction

Iron deficiency is the most common nutritional disorder worldwide, and more prevalent in developing countries.1,2,34,546

Accurate determination of iron status is often difficult and complex. The gold standard for diagnosis of iron deficiency is a bone marrow biopsy demonstrating the absence of stainable iron.2,78

Although haemoglobin concentration, MCV and ferritin are readily available in South Africa, zinc protoporphyrin and soluble transferrin receptor are not commonly measured. Specifically, in our setting at Chris Hani Baragwanath Academic Hospital, the markers available to assess iron status are haemoglobin concentration, MCV, serum iron, transferrin with transferrin saturation (TSAT), and serum ferritin. The diagnosis of the various pathological processes rests on the integrated interpretation of these tests.2,7,9,10

Interpretation of these biochemical parameters with a subsequent diagnosis is not always simple, as the effect of inflammation is a confounding factor that needs to be considered. Chronic inflammation is associated with production of cytokines, which blunts the erythropoietin response. This results in a disruption of normal iron homeostasis and causes increased uptake of iron, with subsequent retention thereof in the reticuloendothelial system. The outcome is iron-restricted erythropoiesis, followed by the development of anaemia of chronic disease (ACD) with an elevated ferritin, low haemoglobin, and decreased TSAT.2,3,1112,13,14,15

In the South African setting, a national health and demographic survey found that as much as a third of South African women of reproductive age are anaemic based on point-of-care haemoglobin measurement, although iron status was not assessed.6161744

A 2016 study in Cape Town, South Africa, found ACD to be the predominant cause of anaemia in patients with HIV and tuberculosis, seen in over 95% of their study population, also utilising the higher ferritin cut-off of < 30 µg/L.1819,20

Evidently, the cut-off used for ferritin for the diagnosis of iron deficiency is not harmonised, with most studies suggesting using < 30 µg/L, and others, < 15 µg/L.2,108

Given the aforementioned context, there is a need to investigate the diagnostic utility of these available biochemical parameters for iron status evaluation in the South African milieu. Thus, the aims of this retrospective study were to analyse and categorise the iron profiles in a South African adult population treated at a tertiary hospital setting, and to evaluate how various ferritin thresholds influence the identification of iron deficiency.

Methods

Ethical considerations

Ethical approval to conduct the study was obtained from the Human Research Ethics Committee of the University of the Witwatersrand (reference no.: M210512). Patients' informed consent was not required due to the retrospective nature of the study. Patient data were de-identified to maintain patient privacy and anonymity. Data were securely stored on a password-protected Excel spreadsheet (Office 2016, Microsoft, Redmond, Washington, United States), accessible only to the investigators of the study. The research was conducted adhering to the ethical principles of the Declaration of Helsinki (2013).

Study design and setting

This study employed a retrospective cross-sectional design analysing laboratory data from patients attending Chris Hani Baragwanath Academic Hospital in Soweto, South Africa. Pathology services are provided primarily by the National Health Laboratory Services, which serves 80% of the population in the public sector health system.

Data collection

Data for the period from 01 October 2020 to 31 March 2021 were obtained from the National Health Laboratory Services Corporate Data Warehouse after mining from the Laboratory Information System (TrackCare Lab, InterSystems Corporation, Cambridge, Massachusetts, United States). The study included results from adult patients (> 18 years) attending Chris Hani Baragwanath Academic Hospital who had the following parameters: sex, haemoglobin, MCV, iron, transferrin, TSAT, and ferritin. Patient results with missing data for age, sex, haemoglobin, ferritin, or TSAT were excluded.

Laboratory analysis

The iron profile analyses (serum iron, transferrin and ferritin) were conducted on the Roche cobas® 8000 automated chemistry analyser (Roche Diagnostics, Mannheim, Germany). Iron was measured using the FerroZine colourimetric method without deproteinisation. Iron reacts with FerroZine to form a coloured complex which is measured photometrically. Transferrin and ferritin were measured using immunoturbidimetric methods utilising anti-human transferrin and anti-human ferritin antibodies, respectively. Transferrin saturation was calculated according to the formula: % saturation = (iron / [transferrin x 25.6]) × 100%.

The haematological parameters (haemoglobin, MCV) were measured using the Sysmex XN10/XN20 series automated haematology analyser (Sysmex Corporation, Kobe, Japan). Haemoglobin was measured spectrophotometrically using a non-cyanide sodium lauryl sulphate. Mean cell volume was calculated as follows: haematocrit % × 10 ÷ red blood cell count. The National Health Laboratory Services laboratory at Chris Hani Baragwanath Academic Hospital maintains accreditation status with the relevant governing bodies and participates in external quality assurance schemes for ongoing independent quality assessment.

Data processing

Data included in the study were classified into IDA, ACD, iron deficiency with ACD (iron deficiency + ACD), iron deficiency without anaemia (IDWA), and iron replete using pre-defined criteria and two different cut-offs for ferritin (Table 1). Haemoglobin and ferritin levels were used as hard criteria for classification, while TSAT was used primarily as an adjunct. Results that did not fall into these categories using the criteria were classified as indeterminate.

Table 1

Statistical analysis

Statistical analyses were performed using SPSS software 29.0.0.0 (IBM Corp. Armonk, New York, United States). All the data were non-parametric when the normality was evaluated using the Shapiro-Wilk test. Categorical data were presented using frequencies and percentages. Non-parametric data were presented as median (interquartile range). The Chi-squared test was used to compare categorical variables, while the Mann-Whitney U test was used to compare the medians of two groups of continuous data. For continuous data with three or more groups, the Kruskal-Wallis test with Bonferroni correction was employed to assess the differences in medians among the groups. A p-value of < 0.05 was considered statistically significant.

Results

Demographics

Following the removal of duplicate episodes (n = 2249), results showing an age below 18 years (n = 248), results with missing demographic data (n = 48), and incomplete profiles (n = 3891), 3221 episodes from a total of 9657 episodes were included in the analysis (Table 2). There was a predominance of women with a ratio of 2.2:1. Women were also younger overall, with a median age of 42 years, compared to 50 years for men. This difference was statistically significant in the IDA (p < 0.001) and iron deficiency + ACD (p < 0.001) groups, but not for the ACD (p = 0.430), IDWA (p = 0.260), iron replete (p = 0.212) and indeterminate (p = 0.345) groups (Figure 1). The majority of requests originated from the inpatient population (62%), primarily from the medical (82%) and surgical departments (17%) for male patients, and from the medical (68%) and maternity (23%) departments for female patients (Online Supplementary Figure 1).

Table 2

Frequencies of iron disorders based on ferritin cut-off

Irrespective of the ferritin cut-off used for iron status classification, ACD was the most prevalent iron disorder (overall = 39%) in this study. In contrast, the frequency of patients with IDA, iron deficiency + ACD, IDWA and iron replete varied depending on the ferritin cut-off employed for the classification (Table 2). The use of the higher ferritin cut-off of 30 µg/L results in a statistically significant increase in the frequency of IDA (p < 0.001) and IDWA (p < 0.001). Utilising this higher ferritin cut-off in combination with a TSAT of <16% improved the differentiation of IDWA from the indeterminate group, reducing the frequency of the latter from 11% to 5% (Online Supplementary Figure 2). The lower ferritin cut-off also precludes the identification of IDWA in the male group. The iron deficient states, IDA, IDWA, and iron deficiency + ACD were more frequent in female patients. Less than 15% of the study group could not be classified into any iron status category as per the criteria in Table 1 and were therefore classified as indeterminate.

Distributions of parameters across different iron status groups

The pattern of distribution of parameters in the IDA group remained consistent across the two different ferritin cut-offs employed (Table 3). Lower levels of iron, TSAT and MCV were found in the IDA and iron deficiency + ACD groups compared to other groups. The highest ferritin levels were present in the ACD (median = 554 µg/L [258-1156]) and indeterminate (median = 170 µg/L [58-361]) groups. The iron replete and indeterminate groups were statistically similar in the distribution of parameters, except for transferrin and ferritin (Table 3).

Table 3

Discussion

Employing a multi-marker approach for the assessment of iron status, we classified 3221 iron profiles using haemoglobin, serum ferritin with two different cut-offs, and TSAT. Consistent with another study conducted in 2020 in patients attending a hospital in Italy,2111,2223

An examination of the impact of applying the two distinct ferritin cut-offs on the distribution of patients between iron status categories revealed a noticeable shift in all groups except for ACD. When using a higher cut-off of 30 µg/L, patients initially categorised as iron deficiency + ACD, iron replete, or indeterminate were re-classified as iron deficiency and IDWA, with a 1.7-fold increase for iron deficiency, and a 5.6-fold increase for IDWA. The cut-off of 30 µg/L has been shown to have significantly higher sensitivity (98%) when compared to a serum ferritin of 15 µg/L, which is highly specific but lacks sensitivity for recognising iron deficiency, as shown in studies conducted in 1998 in America and 1993 in Sweden.24,2526

It is important to identify and treat iron deficiency, even in the absence of anaemia (normal haemoglobin levels), in order to minimise any potential adverse consequences, such as reduced cognitive function, poor performance, and poorer outcomes across a range of medical conditions that may occur in IDWA.27,28,293031312828323334

Mixed aetiology anaemia, iron deficiency + ACD, is characterised by the co-occurrence of true iron deficiency in patients with ACD. The underlying mechanism is thought to be chronic blood loss associated with a disorder with persistent inflammatory activity.3536,371435373237,38

In our study, the observed parameters in patients with IDA form a classic picture of microcytic anaemia, hypoferraemia, low ferritin levels, decreased TSAT percentages, and elevated transferrin levels. Interestingly, regardless of the cut-off, median IDA ferritin levels remained less than 15 µg/L. Mean cell volume was not used in this study as a diagnostic criterion for classification, but its analysis showed that subjects with iron deficiency (IDA, iron deficiency + ACD, and IDWA) tended to have lower median values than subjects with ACD, iron replete, and indeterminate categories. Notably, the median MCV for only the IDA group (72.8 fL, interquartile range: 67.1-79.1) fell below the reference range in our study. Studies show that up to 40% of IDA patients may have a normal MCV, thus its usefulness as a stand-alone diagnostic tool for iron deficiency is very limited.39

Lastly, there was a subset of profiles in our study that could not be categorised into any of the pre-defined groups according to our specified criteria and were deemed indeterminate. This unclassifiable group was predominantly characterised by profiles with normal haemoglobin, elevated serum ferritin, and borderline low TSAT levels, and is suggestive of underlying inflammation potentially affecting these parameters. It is noteworthy that a sizeable number of the profiles would be re-classified as IDWA had the TSAT been used in cases of elevated ferritin levels, decreasing the frequency of this group from 13% to 5% (ferritin < 15 µg/L) and 11% to 5% (ferritin < 30 µg/L).

Limitations

As a retrospective study, this analysis of laboratory data is inherently limited by the lack of information on clinical diagnoses and potentially incomplete data, which may impact the interpretability of the findings. The lack of a comparison to the gold standard diagnostic test, a bone marrow biopsy, made it impossible to verify the accuracy of the IDA classification using ferritin. The lack of inflammatory marker data in this study restricts our ability to incorporate them directly into the analysis of inflammatory conditions groups and the impact on ferritin levels. Specifically, this data cohort was obtained during the coronavirus 2019 pandemic, which could have affected results due to the effect of inflammation on ferritin and transferrin concentration. While a range of ferritin cut-off values have been proposed for the diagnosis of ACD, we opted to utilise a cut-off of 100 µg/L. This specific value aligns with the established threshold for initiating iron replacement therapy in patients with confirmed IDA.1133

Conclusion

In the absence of an acceptable non-invasive gold standard marker for iron deficiency, a ferritin cut-off of 30 µg/L might be a suitable threshold for iron deficiency assessment. While this approach is likely to result in a small increase in false-positive diagnoses, more true iron deficiency cases will be identified compared to a lower ferritin cut-off of 15 µg/L. Furthermore, considering the potential underdiagnosis of IDWA based on existing literature, we recommend screening for iron deficiency using ferritin in patients with normal haemoglobin who present with suggestive clinical symptoms. Our findings highlight the difficulties in accurately assessing iron status using traditional laboratory tests. Non-standardised ferritin cut-offs, suboptimal test performance in inflammatory settings, and considerable overlap in marker profiles between iron deficiency and other conditions contribute to these challenges. Further investigation into the diagnostic accuracy, as well as the feasibility of employing novel markers in our setting, is warranted.

Competing interests

The authors declare that they have no financial or personal relationships that may have inappropriately influenced them in writing this article.

Authors' contributions

The conceptualisation of the study and methodology was developed by J.S.G., D.V.M., S.B.K., and S.K. J.S.G. was involved in data collection, and S.B.K. conducted the data analysis. J.S.G., D.V.M., S.B.K., and S.K. reviewed the findings and contributed to the final article. J.S.G. and S.B.K. created the first draft, and D.V.M. and S.K. edited it.

Sources of support

This research did not receive any specific grant from funding agencies in the public, commercial, or not-for-profit sectors.

Data availability

All data generated from this study are available upon reasonable request from the corresponding author, J.S.G.

Disclaimer

The views and opinions expressed in this article are those of the authors and are the product of professional research. It does not necessarily reflect the official policy or position of any affiliated institution, funder, agency, or that of the publisher. The authors are responsible for this article's results, findings, and content.

Acknowledgements

We express our gratitude to the National Health Laboratory Service Corporate Data Warehouse for their assistance in data mining and for granting us permission to utilise their data for our investigation.

References

  • 1.Thomas C, Thomas L. Biochemical markers and hematologic indices in the diagnosis of functional iron deficiency. Clin Chem. 2002;48(7):1066-1076. https://doi.org/10.1093/clinchem/48.7.1066
    » https://doi.org/10.1093/clinchem/48.7.1066
  • 2.Brugnara C. Iron deficiency and erythropoiesis: New diagnostic approaches. Clin Chem. 2003;49(10):1573-1578. https://doi.org/10.1373/49.10.1573
    » https://doi.org/10.1373/49.10.1573
  • 3.Camaschella C. Iron-deficiency anemia. N Engl J Med. 2015;372(19):1832-1843. https://doi.org/10.1056/NEJMra1401038
    » https://doi.org/10.1056/NEJMra1401038
  • 4.Phatlhane DV, Zemlin AE, Matsha TE, et al. The iron status of a healthy South African adult population. Clin Chim Acta. 2016;460:240-245. https://doi.org/10.1016/j.cca.2016.06.019
    » https://doi.org/10.1016/j.cca.2016.06.019
  • 5.Peyrin-Biroulet L, Williet N, Cacoub P. Guidelines on the diagnosis and treatment of iron deficiency across indications: A systematic review. Am J Clin Nutr. 2015;102(6):1585-1594. https://doi.org/10.3945/ajcn.114.103366
    » https://doi.org/10.3945/ajcn.114.103366
  • 6.Stoltzfus RJ. Iron deficiency: Global prevalence and consequences. Food Nutr Bull. 2003;24(4 Suppl.):S99-S103. https://doi.org/10.1177/15648265030244S206
    » https://doi.org/10.1177/15648265030244S206
  • 7.Dignass A, Farrag K, Stein J. Limitations of serum ferritin in diagnosing iron deficiency in inflammatory conditions. Int J Chronic Dis. 2018;2018:1-11. https://doi.org/10.1155/2018/9394060
    » https://doi.org/10.1155/2018/9394060
  • 8.World Health Organization. WHO guideline on use of ferritin concentrations to assess iron status in individuals and populations [homepage on the Internet]. Geneva: World Health Organization; 2020 [cited 2023 Aug 02]. Available from: https://www.who.int/publications/i/item/9789240000124
    » https://www.who.int/publications/i/item/9789240000124
  • 9.Beutler E, Waalen J. The definition of anemia: What is the lower limit of normal of the blood hemoglobin concentration? Blood. 2006;107(5):1747-1750. https://doi.org/10.1182/blood-2005-07-3046
    » https://doi.org/10.1182/blood-2005-07-3046
  • 10.World Health Organization. Serum ferritin concentrations for the assessment of iron status in individuals and populations: Technical brief [homepage on the Internet]. Geneva: World Health Organization; 2020 [cited 2023 Aug 23]. Available from: https://www.who.int/publications/i/item/9789240008526
    » https://www.who.int/publications/i/item/9789240008526
  • 11.Weiss G, Goodnough LT. Anemia of chronic disease. N Engl J Med. 2005;352:1011-1023. https://doi.org/10.1056/NEJMra041809
    » https://doi.org/10.1056/NEJMra041809
  • 12.Cappellini MD, Comin-Colet J, De Francisco A, et al. Iron deficiency across chronic inflammatory conditions: International expert opinion on definition, diagnosis, and management. Am J Hematol. 2017;92(10):1068-1078. https://doi.org/10.1002/ajh.24820
    » https://doi.org/10.1002/ajh.24820
  • 13.Ganz T. Systemic iron homeostasis. Physiol Rev. 2013;93:1721-1741. https://doi.org/10.1152/physrev.00008.2013
    » https://doi.org/10.1152/physrev.00008.2013
  • 14.Weiss G, Ganz T, Goodnough LT. Anemia of inflammation. Blood. 2019;133(1):40-50. https://doi.org/10.1182/blood-2018-06-856500
    » https://doi.org/10.1182/blood-2018-06-856500
  • 15.Archer NM, Brugnara C. Diagnosis of iron-deficient states. Crit Rev Clin Lab Sci. 2015;52(5):256-272. https://doi.org/10.3109/10408363.2015.1038744
    » https://doi.org/10.3109/10408363.2015.1038744
  • 16.Turawa E, Awotiwon O, Dhansay MA, et al. Prevalence of anaemia, iron deficiency, and iron deficiency anaemia in women of reproductive age and children under 5 years of age in South Africa (1997-2021): A systematic review. Int J Environ Res Public Health. 2021;18(23):12799. https://doi.org/10.3390/ijerph182312799
    » https://doi.org/10.3390/ijerph182312799
  • 17.Symington EA, Baumgartner J, Malan L, et al. Maternal iron-deficiency is associated with premature birth and higher birth weight despite routine antenatal iron supplementation in an urban South African setting: The NuPED prospective study. PLoS One. 2019;14(9):e0221299. https://doi.org/10.1371/journal.pone.0221299
    » https://doi.org/10.1371/journal.pone.0221299
  • 18.Kerkhoff AD, Meintjes G, Opie J, et al. Anaemia in patients with HIV-associated TB: Relative contributions of anaemia of chronic disease and iron deficiency. Int J Tuberc Lung Dis. 2016;20(2):193-201. https://doi.org/10.5588/ijtld.15.0558
    » https://doi.org/10.5588/ijtld.15.0558
  • 19.De Santis GC, Brunetta DM, Vilar FC, et al. Hematological abnormalities in HIV-infected patients. Int J Infect Dis. 2011;15(12):e808-e811. https://doi.org/10.1016/j.ijid.2011.08.001
    » https://doi.org/10.1016/j.ijid.2011.08.001
  • 20.Braga F, Infusino I, Dolci A, Panteghini M. Soluble transferrin receptor in complicated anemia. Clin Chim Acta. 2014;431:143-147. https://doi.org/10.1016/j.cca.2014.02.005
    » https://doi.org/10.1016/j.cca.2014.02.005
  • 21.Randi ML, Bertozzi I, Santarossa C, et al. Prevalence and causes of anemia in hospitalized patients: Impact on diseases outcome. J Clin Med. 2020;9(4):950. https://doi.org/10.3390/jcm9040950
    » https://doi.org/10.3390/jcm9040950
  • 22.Madu AJ, Ughasoro MD. Anaemia of chronic disease: An in-depth review. Med Princ Pract. 2017;26(1):1-9. https://doi.org/10.1159/000452104
    » https://doi.org/10.1159/000452104
  • 23.Peng YY, Uprichard J. Ferritin and iron studies in anaemia and chronic disease. Ann Clin Biochem. 2017;54(1):43-48. https://doi.org/10.1177/0004563216675185
    » https://doi.org/10.1177/0004563216675185
  • 24.Mast AE, Blinder MA, Gronowski AM, Chumley C, Scott MG. Clinical utility of the soluble transferrin receptor and comparison with serum ferritin in several populations. Clin Chem. 1998;44(1):45-51. https://doi.org/10.1093/clinchem/44.1.45
    » https://doi.org/10.1093/clinchem/44.1.45
  • 25.Hallberg L, Bengtsson C, Lapidus L, Lindstedt G, Lundberg P-A, Hultén L. Screening for iron deficiency: An analysis based on bone-marrow examinations and serum ferritin determinations in a population sample of women. Br J Haematol. 1993;85(4):787-798. https://doi.org/10.1111/j.1365-2141.1993.tb03225.x
    » https://doi.org/10.1111/j.1365-2141.1993.tb03225.x
  • 26.Daru J, Colman K, Stanworth SJ, et al. Serum ferritin as an indicator of iron status: What do we need to know? Am J Clin Nutr. 2017;106:1634-1643. https://doi.org/10.3945/ajcn.117.155960
    » https://doi.org/10.3945/ajcn.117.155960
  • 27.Rattehalli D, Pickard L, Tselepis C, Sharma N, Iqbal TH. Iron deficiency without anaemia: Do not wait for the haemoglobin to drop? Health Policy Technol. 2013;2(1):45-58. https://doi.org/10.1016/j.hlpt.2012.12.005
    » https://doi.org/10.1016/j.hlpt.2012.12.005
  • 28.Al-Naseem A, Sallam A, Choudhury S, Thachil J. Iron deficiency without anaemia: A diagnosis that matters. Clin Med (Lond). 2021;21(2):107-113. https://doi.org/10.7861/clinmed.2020-0582
    » https://doi.org/10.7861/clinmed.2020-0582
  • 29.Soppi ET. Iron deficiency without anemia - A clinical challenge. Clin Case Rep. 2018;6(6):1082-1086. https://doi.org/10.1002/ccr3.1529
    » https://doi.org/10.1002/ccr3.1529
  • 30.Simic S, Karczewski M, Klapdor S, et al. Effectiveness of low-dose iron treatment in non-anaemic iron-deficient women: A prospective open-label single-arm trial. Swiss Med Wkly. 2023;153(5):40079. https://doi.org/10.57187/smw.2023.40079
    » https://doi.org/10.57187/smw.2023.40079
  • 31.Abuaisha M, Itani H, El Masri R, Antoun J. Prevalence of iron deficiency (ID) without anemia in the general population presenting to primary care clinics: A cross-sectional study. Postgrad Med. 2020;132(3):282-287. https://doi.org/10.1080/00325481.2020.1715701
    » https://doi.org/10.1080/00325481.2020.1715701
  • 32.Rohr M, Brandenburg V, Brunner-La Rocca HP. How to diagnose iron deficiency in chronic disease: A review of current methods and potential marker for the outcome. Eur J Med Res. 2023;28(1):15. https://doi.org/10.1186/s40001-022-00922-6
    » https://doi.org/10.1186/s40001-022-00922-6
  • 33.Fletcher A, Forbes A, Svenson N, Wayne Thomas D. Guideline for the laboratory diagnosis of iron deficiency in adults (excluding pregnancy) and children. Br J Haematol. 2022;196(3):523-529. https://doi.org/10.1111/bjh.17900
    » https://doi.org/10.1111/bjh.17900
  • 34.Omuse G, Chege A, Kawalya DE, Kagotho E, Maina D. Ferritin and its association with anaemia in a healthy adult population in Kenya. PLoS One. 2022;17(10):e0275098. https://doi.org/10.1371/journal.pone.0275098
    » https://doi.org/10.1371/journal.pone.0275098
  • 35.Svenson N, Bailey J, Durairaj S, Dempsey-Hibbert N. A simplified diagnostic pathway for the differential diagnosis of iron deficiency anaemia and anaemia of chronic disease. Int J Lab Hematol. 2021;43(6):1644-1652. https://doi.org/10.1111/ijlh.13666
    » https://doi.org/10.1111/ijlh.13666
  • 36.Goodnough LT, Nemeth E, Ganz T. Detection, evaluation, and management of iron-restricted erythropoiesis. Blood. 2010;116(23):4754-4761. https://doi.org/10.1182/blood-2010-05-286260
    » https://doi.org/10.1182/blood-2010-05-286260
  • 37.Skikne BS, Punnonen K, Caldron PH, et al. Improved differential diagnosis of anemia of chronic disease and iron deficiency anemia: A prospective multicenter evaluation of soluble transferrin receptor and the sTfR/log ferritin index. Am J Hematol. 2011;86(11):923-927. https://doi.org/10.1002/ajh.22108
    » https://doi.org/10.1002/ajh.22108
  • 38.Lyle AN, Budd JR, Kennerley VM, et al. Assessment of WHO 07/202 reference material and human serum pools for commutability and for the potential to reduce variability among soluble transferrin receptor assays. Clin Chem Lab Med. 2023;61(10):1719-1729. https://doi.org/10.1515/cclm-2022-1198
    » https://doi.org/10.1515/cclm-2022-1198
  • 39.Bermejo F, García-López S. A guide to diagnosis of iron deficiency and iron deficiency anemia in digestive diseases. World J Gastroenterol. 2009;15(37):4638-4643. https://doi.org/10.3748/wjg.15.4638
    » https://doi.org/10.3748/wjg.15.4638

Correspondence:
Jurette Grove

Received: 24 May 2024
Accepted: 12 Aug. 2024
Published: 18 Oct. 2024

Note: Additional supporting information may be found in the online version of this article as Online Supplementary Document 1.

Correspondence

jurettegrove@gmail.com

Publication Dates

  • Publication in this collection
    15 Jan 2025
  • Date of issue

History

  • Received
    24 May 2024
  • Accepted
    12 Aug 2024
location_on
African Society for Laboratory Medicine (Ethiopia) AOSIS Publishing, Postnet Suite #110, Private Bag X19, Durbanville, Western Cape, ZA, 7551, Tel: +27 21 975 2602, Tel: 086 1000 381 - E-mail: publishing@aosis.co.za
rss_feed Stay informed of issues for this journal through your RSS reader
Go to top