Open-access In-depth investigation of turn-around time of full blood count tests requested from a clinical haematology outpatient department in Cape Town, South Africa

Abstract

BACKGROUND: The performance of laboratories can be objectively assessed using the overall turn-around time (TAT). However, TAT is defined differently by the laboratory and clinicians; therefore, it is important to determine the contribution of all the different components making up the laboratory test cycleOBJECTIVE: We carried out a retrospective analysis of the TAT of full blood count tests requested from the haematology outpatient department at Tygerberg Academic Hospital in Cape Town, South Africa, with an aim to assess laboratory performance and to identify critical steps influencing TATMETHODS: A retrospective audit was carried out, focused on the full blood count tests from the haematology outpatient department within a period of 3 months between 01 February and 30 April 2018. Data was extracted from the National Health Laboratory Service laboratory information system. The time intervals of all the phases of the test cycle were determined and total TAT and within-laboratory (intra-lab) TAT were calculatedRESULTS: A total of 1176 tests were analysed. The total TAT median was 275 (interquartile range [IQR] 200.0-1537.7) min with the most prolonged phase being from authorisation to review by clinicians (median 114 min; IQR: 37.0-1338.5 min). The median intra-lab TAT was 55 (IQR 40-81) min and 90% of the samples were processed in the laboratory within 134 min of registrationCONCLUSION: Our findings showed that the intra-lab TAT was within the set internal benchmark of 3 h. Operational phases that were independent of the laboratory processes contributed the most to total TAT

audit; turn-around time; full blood count; haematology clinic


Introduction

The increase in the number of patients accessing the public health system and the disproportionate patient to healthcare provider ratio in developing countries necessitates more efficient and cost-effective approaches to healthcare provision.1,2345,678

The TAT is crucial in clinical practice and is used as a measure of the performance of laboratories.55,6,9,109

Clinicians tend to view TAT as the time between requisition of a test and when they view a result.1112,135512

To assess the hypothesis that our laboratory performance was within set local benchmarks and comparable with the widely accepted international benchmark of completion of 90% of the sample processing within 60 min, we performed a retrospective analysis to evaluate the respective contribution of the various phases of the test cycle to the total TAT at Tygerberg Academic Hospital (TBH) in Cape Town, South Africa.14

Methods

Ethical considerations

This retrospective study was approved by the Stellenbosch University Research Ethics Committee (S18/10/232) and performed according to the Declaration of Helsinki. A waiver of consent was obtained, and patient confidentiality was maintained. Moreover, patient-level data was not accessed.

Study design and setting

A retrospective audit was conducted over a 3-month period between 01 February and 30 April 2018 at the haematological pathology laboratory of the tertiary referral TBH in Cape Town, South Africa. The laboratory and its reception operate on a 24-h service and have three shifts: regular shift (08:00 to 16:30), evening shift (16:30 to 20:00) and night shift (20:00 to 08:00).

The laboratory provides diagnostic pathology services to regional hospitals and clinics in the Western Cape, South Africa. At TBH laboratory reception, samples go through the processes of sorting, registration and labelling before being transported to the haematology laboratory for analysis where samples are loaded into a Siemens ADVIA 2120i haematology analyser (Siemens Healthcare Diagnostics, Erlangen, Germany). This analyser has the capacity of performing 120 full blood counts (FBCs) and differentials per hour. From the haematology analyser the preliminary results are entered into the laboratory information system (LIS) at which point the results are available to clinicians as provisional results. The laboratory fast-tracks all urgent samples and aims to release the results within 3 h. Samples from the haematology clinic are treated as urgent and are colour coded and given preference over other routine samples. The LIS (InterSystems TrakCare® Lab Enterprise, Cambridge, Massachusetts, United States) tracks the processing of samples at various time points (preanalytical, analytical, and post-analytical).

The haematology clinic is housed in a separate building from the main building that houses the haematology laboratory. At this clinic, tests are requested through paper forms which are then placed alongside the samples into transporting bags and transported to the laboratory reception by porters or, rarely, by doctors or nurses. The clinic operates Monday to Friday from 07:00 to 16:00. Clinicians start seeing patients at 08:00 and most of the patient consultations are usually complete by 14:00, after which time the clinicians leave for the ward. Patients who arrive late are seen by one clinician until 16:00 when the clinic closes.

Data collection

We retrieved and extracted data from the LIS to determine the TAT reflecting all the operational phases. Reports with two or more missing entries of the date or time points on the LIS were excluded. Full blood counts done as part of bone marrow examination requests were also excluded as they are not reported separately but as part of the full bone marrow report. Four main phases of the test cycles were identified and evaluated. The first phase is between collection of samples (phlebotomy) and registration of the same in the laboratory. This is followed by the phase between registration of samples, processing by the haematology analyser, and loading of preliminary results into the LIS. The third phase is when preliminary results are reviewed by laboratory staff and then authorised, and the final phase is from authorisation of results to when clinicians view these results. In this study, the total TAT was defined as the time taken from specimen collection to the review of the results by the requesting clinician, while the intra-laboratory TAT was defined as the time taken from specimen registration to authorisation of results after review of preliminary results by the laboratory staff. Total TAT was therefore calculated, for each sample, by adding the time taken in the four phases which are: collection to registration, registration to acquisition into LIS, acquisition into LIS to authorisation and, finally, authorisation to review by clinicians. Intra-lab TAT was calculated by adding the time taken in the two phases which are: registration to acquisition into LIS and acquisition into LIS to authorisation of results. We also carried out a sub-analysis of samples collected in the month of April. The operation phase from the collection of samples to registration was divided into two phases: transportation time (collection to receipt in the laboratory) and sorting time (from receipt in the laboratory to registration of samples). The relative contribution of these two phases were determined and compared to that of a similar study.12

Statistical analysis

Data items which included sample collection, registration, acquisition to LIS, authorisation and review by clinicians were extracted from the LIS onto Microsoft® Office Excel (Redmond, Washington, United States) 2016 (version 16.0). Assessment of normality was done using the Kolmogorov-Smirnov test at p < 0.05 significance level.151612p < 0.05 were considered statistically significant. Using the percentage contribution of each phase for all 1176 samples, median percentages were calculated. The same was done for the intra-lab TAT for each of the 1176 samples. All data analyses were performed using Statistica Software version 8 (TIBCO Software Inc., Palo Alto, California, United States).

Results

A total of 1505 FBCs were requested between 01 February and 30 April 2018 from the haematology clinic, TBH, Cape Town. We performed an analysis on a subset of the retrieved FBC reports over the study period. A total of 329 (22%) patient reports were excluded either due to missing data (2 or more missing data points) or being reports for FBCs requested as part of a bone marrow biopsy (Figure 1). In all, this retrospective study included a total of 1176 FBC reports. Delays in registration of samples after receipt by the laboratory would not be reflected on the intra-laboratory TAT but on the total TAT. Therefore, a sub-analysis of the phase between collection and registration was performed for the month of April 2018. This comprised 412 samples for the phase between collection of samples to receipt in the laboratory and 420 samples for the phase from receipt to registration. Seventy percent of the 1176 samples were collected by 9:00 and 90% by 11.00. Considering the closing time of the clinic, the clinicians had a window of 7 h and 5 h to receive results and make clinical decisions for 70% and 90% of patients.

Intra-laboratory turn-around time and total turn-around time

The majority of the FBC samples (93.3%) had an intra-lab TAT of less than 3 h and most of them (80.1%) were processed within 90 min (Table 1). The median intra-lab TAT was 55 (IQR 40-81) min and had a median percentage of 17.1% of the total TAT (Table 2). Ninety percent of the results were ready for viewing by clinicians within 134 min of registration. The median total TAT was 275 (IQR 200.0-1537.7) min. The phases within the preanalytical and post-analytical phases contribute the most to the total TAT, with collection time to registration and time to review results by clinicians representing a median of 32.5% (IQR 7.8-48.7) and 44.3% (IQR 18.1-87.0). The total TAT was significantly delayed compared to the calculated expected TAT (p < 0.05).

Table 1

Table 2

Preanalytical phase

The preanalytical phase, defined in this study as the time from collection of samples to registration, had a median of 96 min (Table 2). Ninety percent of the samples completed this phase within 218 min. A sub-analysis of this phase during the month of April revealed a median of 60 (IQR 45-85) min for the period between collection of the sample to receipt in the laboratory (transportation) and a median of 39 (IQR 23.35-58.00) min from receipt to registration (sorting) (Table 3). Most of the samples (90%) spent less than 95 min in the sorting area. Our laboratory performed significantly worse when we compared the time spent in the sorting area for each sample in April with the median of 15 min at New York Presbyterian Hospital, another tertiary hospital described in literature, using the chi-square test.12

Analytical phases

We categorised the analytical phase into two independent intervals (interval 2 and interval 3) (Table 1). Our analysis showed that most samples (73.3%) spent less than 60 min in interval 2 while 85.2% of samples were authorised within 30 min in interval 3. Notably, a few samples, 26.6 % and 6.3%, took more than 1 h in interval 2 and interval 3. The authorisation of reports is also impacted by the battery of laboratory tests requested and this may explain the minority of samples authorised after an hour.

Post-analytical phase

We further evaluated the time taken by clinicians to review the authorised reports (interval 4). We observed a significant number of reports (48.9%) that were accessed after 2 h, while only 22.7% of the reports were viewed within 30 min (Table 1). Notably, 38.6% of reports were viewed after 4 h. The median time for this phase was 114 (IQR 37.0-1338.5) min and the time to view 90% of the reports was 10.78 days (Table 2).

Discussion

The constant increase in medical care cost and the growing demand for improved quality of care has necessitated the monitoring of determinants of the quality of healthcare services.17,181917

Samples from the haematology outpatient department at TBH are regarded as urgent because for most patients, FBCs are required to make decisions on chemotherapy, transfusion and other interventions before leaving the clinic. The results of this study were therefore compared to findings of studies on TAT of emergency departments. Our findings were similar to those previously reported.5,20

In addition to the lack of consensus on the definition of TAT, there is also no specific benchmark for TAT parameters.2116222223245,7,23,24121212

Total TAT was significantly prolonged compared to the expected TAT, with phases outside the laboratory causing the most delay. The time taken to view results by clinicians was the longest with a median time of 114 (IQR 37.0-1338.5) min. This could be due to the limited period during which clinicians can view results. Once this window has elapsed the results can only be viewed on the patient's next appointment which can vary from a day to several months later. This is a limitation of total TAT in assessing laboratory performance, which explains in part why laboratories resort to the use of intra-lab TAT.1225,26

As it is noted that a pragmatic approach is to set TAT goals locally, informed by both the published literature and by local expectations,5272,28

Limitations

This study was limited by the absence of an interventional process, and we therefore recommend a follow-up audit after implementing some of the proposed solutions. The results from this study cannot be extrapolated to all hospitals and departments but only to those with a similar setting, as they are solely based on the experience of the haematology clinic at TBH. The collection times were based on what was reported by the nurses at the clinic; therefore, the accuracy of the recorded time following each phlebotomy cannot be ascertained. This is not the case for other time points retrieved from the LIS as they are computer generated in real time. In addition, the laboratory receipt time for samples was not available for the entire study period. As noted earlier, 22% of the data had 2 or more missing data points which were critical in the calculation of intra-lab TAT and total TAT. This has the potential of introducing bias, which is likely if the proportion of missing data is greater than 10%.2930

Conclusion

This study demonstrated that TBH laboratory was compliant with its intra-lab TAT benchmark and that the 90% completion time target was achieved for samples from the haematology outpatient clinic. The phases outside the control of the laboratory were primarily responsible for prolonged total TATs. The monitoring of TAT is a powerful tool for assessing a laboratory service's performance and contributes to patient care. However, as demonstrated in this study, monitoring and process improvement requires measurement of TATs for individual phases of the test cycle.

Competing interests

The authors declare that they have no financial or personal relationships that may have inappropriately influenced them in writing this article.

Authors' contributions

N.M. and Z.C. supervised the study by providing leadership and oversight. L.M. conceptualised the study, conducted the research and wrote the initial manuscript. F.M. and L.M. conducted data analysis. All authors contributed to final manuscript development.

Sources of support

The authors received no financial support for the research, authorship or publication of this article.

Data availability

The data that support the findings of this study are available from the corresponding author, L.M., upon reasonable request.

Disclaimer

The views and opinions expressed in this article are those of the authors and do not necessarily reflect the official policy or position of any affiliated agency of the authors.

Acknowledgements

The authors would like to thank Ms Fazlin Kolia, the laboratory manager, for providing us with permission to use LIS data and standard operation procedures. We also would like to extend our gratitude to Mr Wessel Kleinhans for his critical role in data mining from the LIS. Lastly, we would like to thank Prof. Bongani Nkambule for assistance in analysis of the data.

References

  • 1.Veld M, Van De Voorde K. How to take care of nurses in your organization: Two types of exchange relationships compared. J Adv Nurs. 2013;70(4):855-865. https://doi.org/10.1111/jan.12247
    » https://doi.org/10.1111/jan.12247
  • 2.Van Rensburg H. South Africa's protracted struggle for equal distribution and equitable access - Still not there. 2014;12(26):1-16. https://doi.org/10.1186/1478-4491-12-26
    » https://doi.org/10.1186/1478-4491-12-26
  • 3.Mishra V. Measuring technical efficiency in healthcare service: A case study. Pacific Bus Rev Int. 2019;11(6):36-43.
  • 4.Valenstein P. Laboratory turnaround time. Am J Clin Pathol. 1996;105(6):676-688. https://doi.org/10.1093/ajcp/105.6.676
    » https://doi.org/10.1093/ajcp/105.6.676
  • 5.Hawkins RC. Laboratory turnaround time. Clin Biochem Rev. 2007;28(4):179-194.
  • 6.Jalili M, Shalileh K, Mojtahed M, Moradi-Lakesh M. Identifying causes of laboratory turnaround time delay in the emergency department. Arch Iran Med. 2012;15(12):759-763.
  • 7.Kaushik N, Khangulov VS, O'Hara M, Arnaout R. Reduction in laboratory turnaround time decreases emergency room length of stay. Open Access Emerg Med. 2018;10:37-45. https://doi.org/10.2147/OAEM.S155988
    » https://doi.org/10.2147/OAEM.S155988
  • 8.Imoh LC, Mutale M, Parker CT, Erasmus RT, Zemlin AE. Laboratory-based clinical audit as a tool for continual improvement: An example from CSF chemistry turnaround time audit in a South-African teaching hospital. Biochem Medica. 2016;26(2):194-201. https://doi.org/10.11613/BM.2016.021
    » https://doi.org/10.11613/BM.2016.021
  • 9.Schimke I. Quality and timeliness in medical laboratory testing. Anal Bioanal Chem. 2009;393(5):1499-1504. https://doi.org/10.1007/s00216-008-2349-5
    » https://doi.org/10.1007/s00216-008-2349-5
  • 10.Groenewald AJ, Potgieter HD. Physician satisfaction and emergency (stat) laboratory turnaround time during various developmental stages. Med Technol SA. 2014;28(1):20-25.
  • 11.Weinstein S. Quality in pathology laboratory practice. J Qual Clin Pr. 1995;15(2):121-126.
  • 12.Stotler BA, Kratz A. Determination of turnaround time in the clinical laboratory. Am J Clin Pathol. 2012;138(5):724-729. https://doi.org/10.1309/AJCPYHBT9OQRM8DX
    » https://doi.org/10.1309/AJCPYHBT9OQRM8DX
  • 13.Chung HJ, Lee W, Chun S, Park H-I, Min WK. Analysis of turnaround time by subdividing three phases for outpatient chemistry specimens. Ann Clin Lab Sci. 2009;39(2):144-149.
  • 14.Howanitz PJ. Errors in laboratory medicine: Practical lessons to improve patient safety. Arch Pathol Lab Med. 2005;129(10):1252-1261.
  • 15.Mishra P, Pandey C, Singh U, Gupta A, Sahu C, Keshri A. Descriptive statistics and normality tests for statistical data. Ann Card Anaesth. 2019;22(1):67-72. https://doi.org/10.4103/aca.ACA_157_18
    » https://doi.org/10.4103/aca.ACA_157_18
  • 16.Howanitz JH, Howanitz PJ. Timeliness as a quality attribute and strategy. Am J Clin Pathol. 2001;116(3):311-315. https://doi.org/10.1309/H0DY-6VTW-NB36-U3L6
    » https://doi.org/10.1309/H0DY-6VTW-NB36-U3L6
  • 17.Howanitz P, Cembrowski G, Steindel SJ, Long T. Physician goals and laboratory test turnaround times. A college of American pathologists Q-probes study of 2763 clinicians and 722 institutions. Arch Pathol Lab Med. 1993;117(1):22-28.
  • 18.Breil B, Fritz F, Thiemann V, Dugas M. Mapping turnaround times (TAT) to a generic timeline: A systematic review of TAT definitions in clinical domains. BMC Med Inform Decis Mak. 2011;11(34):1-12. https://doi.org/10.1186/1472-6947-11-34
    » https://doi.org/10.1186/1472-6947-11-34
  • 19.Bloch DM. Computer-generated management tools for the clinical pathology laboratory - II. Computer-generated graphic work flow. J Med Syst. 1982;6(3):305-310. https://doi.org/10.1007/BF00992807
    » https://doi.org/10.1007/BF00992807
  • 20.Mahdaviazad H, Javidialesaadi F, Hosseinzadeh M, Masoompour SM. Turnaround times for hematology and chemistry tests in the emergency department: Experience of a teaching hospital in Iran. Shiraz E Med J. 2016;17(4-5):e37101. https://doi.org/10.17795/semj37101
    » https://doi.org/10.17795/semj37101
  • 21.Dey B, Bharti J, Chakraborty M. Laboratory turnaround time. Int J Heal Sci Res. 2013;3(5):82-84.
  • 22.Steindel SJ, Howanitz PJ. Physician satisfaction and emergency department laboratory test turnaround time. Arch Pathol Lab Med. 2001;125(7):863-871.
  • 23.Bolodeoku J, Ogbeiwi O, Kuti MA, Adebisi SA. Laboratory tests turnaround time in outpatient and emergency patients in Nigeria: Results of a physician survey on point of care testing. Int J Med Res Heal Sci. 2017;6(5):76-81.
  • 24.Fei Y, Zeng R, Wang W, He F, Zhong K, Wang Z. National survey on intra-laboratory turnaround time for some most common routine and stat laboratory analyses in 479 laboratories in China. Biochem Medica. 2015;25(2):213-221. https://doi.org/10.11613/BM.2015.021
    » https://doi.org/10.11613/BM.2015.021
  • 25.Fernandes C, Worster A, Eva K, Hill S, McCallum C. Pneumatic tube delivery system for blood samples reduces turnaround times without affecting sample quality. J Emerg Nurs. 2006;32(2):139-143. https://doi.org/10.1016/j.jen.2005.11.013
    » https://doi.org/10.1016/j.jen.2005.11.013
  • 26.Guss D, Chan T, Killeen J. The impact of a pneumatic tube and computerized physician order management on laboratory turnaround time. Ann Emerg Med. 2008;51(2):181-185. https://doi.org/10.1016/j.annemergmed.2007.03.010
    » https://doi.org/10.1016/j.annemergmed.2007.03.010
  • 27.Cassim N, Coetzee LM, Tepper ME, Perelson L, Glencross DK. Timely delivery of laboratory efficiency information, part I: Developing an interactive turnaround time dashboard at a high-volume laboratory. Afr J Lab Med. 2020;9(2):a948. https://doi.org/10.4102/ajlm.v9i2.948
    » https://doi.org/10.4102/ajlm.v9i2.948
  • 28.Malakoane B, Heunis JC, Chikobvu P, Kigozi NG, Kruger WH. Public health system challenges in the Free State, South Africa: A situation appraisal to inform health system strengthening. BMC Health Serv Res. 2020;20(1):1-14. https://doi.org/10.1186/s12913-019-4862-y
    » https://doi.org/10.1186/s12913-019-4862-y
  • 29.Bennett DA. How can I deal with missing data in my study? Aust N Z J Public Health. 2001;25(5):464-469. https://doi.org/10.1111/j.1467-842X.2001.tb00294.x
    » https://doi.org/10.1111/j.1467-842X.2001.tb00294.x
  • 30.Shortreed SM, Forbes AB. Missing data in the exposure of interest and marginal structural models: A simulation study based on the Framingham Heart study. Stat Med. 2010;29(4):431-443.

Correspondence:
Leonard Mutema

Received: 27 June 2020
Accepted: 06 Jan. 2021
Published: 29 Apr. 2021

Correspondence

lpmutemah88@gmail.com

Publication Dates

  • Publication in this collection
    13 Dec 2021
  • Date of issue

History

  • Received
    27 June 2020
  • Accepted
    06 Jan 2021
location_on
African Society for Laboratory Medicine (Ethiopia) AOSIS Publishing, Postnet Suite #110, Private Bag X19, Durbanville, Western Cape, ZA, 7551, Tel: +27 21 975 2602, Tel: 086 1000 381 - E-mail: publishing@aosis.co.za
rss_feed Acompañe los números de esta revista en su lector de RSS
Ir para arriba