<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>1681-150X</journal-id>
<journal-title><![CDATA[SA Orthopaedic Journal]]></journal-title>
<abbrev-journal-title><![CDATA[SA orthop. j.]]></abbrev-journal-title>
<issn>1681-150X</issn>
<publisher>
<publisher-name><![CDATA[CHAR Publications]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S1681-150X2012000200009</article-id>
<title-group>
<article-title xml:lang="en"><![CDATA[No loosening of an uncemented acetabular component at a minimum of 15 years]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Martin]]></surname>
<given-names><![CDATA[Nicolas]]></given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Nortje]]></surname>
<given-names><![CDATA[Marc]]></given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Orth]]></surname>
<given-names><![CDATA[FC]]></given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Dower]]></surname>
<given-names><![CDATA[Brendan]]></given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Learmonth]]></surname>
<given-names><![CDATA[Ian]]></given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Grobler]]></surname>
<given-names><![CDATA[Garth]]></given-names>
</name>
</contrib>
</contrib-group>
<aff id="A">
<institution><![CDATA[,  ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>04</month>
<year>2012</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>04</month>
<year>2012</year>
</pub-date>
<volume>11</volume>
<numero>2</numero>
<fpage>49</fpage>
<lpage>51</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.za/scielo.php?script=sci_arttext&amp;pid=S1681-150X2012000200009&amp;lng=en&amp;nrm=iso&amp;tlng=en"></self-uri><self-uri xlink:href="http://www.scielo.org.za/scielo.php?script=sci_abstract&amp;pid=S1681-150X2012000200009&amp;lng=en&amp;nrm=iso&amp;tlng=en"></self-uri><self-uri xlink:href="http://www.scielo.org.za/scielo.php?script=sci_pdf&amp;pid=S1681-150X2012000200009&amp;lng=en&amp;nrm=iso&amp;tlng=en"></self-uri><abstract abstract-type="short" xml:lang="en"><p><![CDATA[One hundred consecutive total hip replacements using a cementless Duraloc 300 cup were reviewed at a minimum of 15 years. All acetabular metal components were found to be stable with no evidence of loosening.]]></p></abstract>
<kwd-group>
<kwd lng="en"><![CDATA[Hip]]></kwd>
<kwd lng="en"><![CDATA[arthroplasty]]></kwd>
<kwd lng="en"><![CDATA[acetabular]]></kwd>
<kwd lng="en"><![CDATA[loose]]></kwd>
<kwd lng="en"><![CDATA[fixation]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[ <p align="right"><font face="Verdana, Arial, Helvetica, sans-serif" size="2"><b>CLINICAL    ARTICLE</b></font></p>     <p>&nbsp;</p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="4"><b><a name="top"></a>No    loosening of an uncemented acetabular component at a minimum of 15 years</b></font></p>     <p>&nbsp;</p>     <p>&nbsp;</p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"><b>Nicolas Martin    MBChB, FCS(Orth); Marc Nortje MBChB, FC Orth, MMed; Brendan Dower MBChB, FCS(Orth);    Ian Learmonth MBChB, FRCS(Orth); Garth Grobler MBChB, FCS(Orth), MMed</b></font></p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"><a href="#back">Reprint    requests</a></font></p>     <p>&nbsp;</p>     <p>&nbsp;</p> <hr size="1" noshade>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"><b>ABSTRACT</b></font></p>     ]]></body>
<body><![CDATA[<p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">One hundred consecutive    total hip replacements using a cementless Duraloc 300 cup were reviewed at a    minimum of 15 years. All acetabular metal components were found to be stable    with no evidence of loosening.</font></p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"><b>Key words:</b>    Hip, arthroplasty, acetabular, loose, fixation</font></p> <hr size="1" noshade>     <p>&nbsp;</p>     <p>&nbsp;</p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="3"><b>Introduction</b></font></p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">In our previous    10-year review of these patients we found a zero rate of loosening and a mean    polyethylene wear rate of 0.12mm per year.<sup>1</sup></font></p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">The purpose of    this paper is to retrospectively review the ongoing radiological results of    this cohort of consecutive total hip replacements.</font></p>     <p>&nbsp;</p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="3"><b>Patients and    methods</b></font></p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">Between August    1991 and July 1993, we performed 100 consecutive total hip replacements in 93    patients (48 men and 45 women). Two experienced hip surgeons performed 93 operations    and seven were undertaken by registrars under supervision. The surgery was performed    via a modified anterior approach as previously described.<sup>1 </sup>The Duraloc    300, tri-spiked, Porocoat acetabular implants were used with a polyethylene    liner containing a 10&deg; long wall, that was gamma irradiated in air.</font></p>     ]]></body>
<body><![CDATA[<p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">Of the original    100 hips, 35 patients died (37 hips) at an average of seven years post surgery.    None of these patients had undergone a re-operation and all had a satisfactory    fixation of the acetabular cup as seen on radiographs taken on average 1.7 years    before death. Six patients (seven hips) were lost to follow-up leaving 56 hips    available for analysis after a minimum duration of follow-up of 15 years.</font></p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">The patients' radiographs    (post-operative, 10 year, 15 year) were analysed with respect to loosening,<sup>2,3</sup>    liner wear,<sup>4,5</sup> granuloma evolution<sup>6</sup> as well as bone graft    incorporation post liner revision. Migration or position of the liner was assessed    according to the method of Massin <i>et al.<sup>3</sup></i></font></p>     <p>&nbsp;</p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="3"><b>Results</b></font></p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">At 15-year follow-up    none of the acetabular implants showed any evidence of loosening. We defined    loosening as cup migration or lucent lines of more than 1 mm diameter present    in all three zones (as per Hodgkinson <i>et</i> al.<sup>2</sup>).</font></p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">The average wear    at 15-year follow-up was 0.08 mm/y. This was less than the 0.12 mm/y at 10-year    follow-up. Fourteen hips had granulomas at 15-year follow-up. Eleven of these    granulomas were situated in zone 2, which may be related to the fact that a    hole eliminator had not been used in these cups.</font></p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">Eleven patients    required revision surgery. Two had well-fixed cups removed at the time of stem    revision at another institution, one had the long wall repositioned for early    dislocation, five had liner revision and underwent impaction bone grafting to    granulomas, three had liner exchange for excessive wear without granuloma present.</font></p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">Four of these revisions    took place in the last 5 years. Three were liner revisions only (two for excessive    wear, one during granuloma bone-grafting), while one had the liner changed during    revision of a loose stem post periprosthetic fracture.</font></p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">In the five hips    that were revised for granuloma around the cup, all showed good graft incorporation    and remodelling. There were no complications related to the revision surgery.</font></p>     <p>&nbsp;</p>     ]]></body>
<body><![CDATA[<p><font face="Verdana, Arial, Helvetica, sans-serif" size="3"><b>Statistics</b></font></p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">Kaplan-Meier survivorship    analysis was performed with radiological loosening and liner revision as an    end point. The survival at 15 years for loosening was 100%. The survival for    liner revision was 84.93% (95% confidence interval of 76.02-93.83%)</font></p>     <p>&nbsp;</p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="3"><b>Discussion</b></font></p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">The zero radiological    loosening rate of the Duraloc 300 cups at 15 years would indicate that spiked    Porocoated cups provides sufficient bone in-growth for long-term stability even    in cases with granuloma formation.</font></p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">The wear rate of    0.08 mm/year is less than the one found at 10-year follow-up. We assume that    this decrease is due to a combination of decreased activity levels in the ageing    study cohort as well as less statistical impact of the initial running-in wear    over the extended time period.<sup>7</sup></font></p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">The predominance    of zone 2 granuloma indicates that wear particles gained entry to the bony acetabulum    via the apex hole for the cup introducer. Use of a hole eliminator would be    prudent <i>(<a href="#f1">Figures 1-4</a>).</i></font></p>     <p><a name="f1"></a></p>     <p>&nbsp;</p>     <p align="center"><img src="/img/revistas/saoj/v11n2/09f01.jpg"></p>     ]]></body>
<body><![CDATA[<p>&nbsp;</p>     <p>&nbsp;</p>     <p align="center"><img src="/img/revistas/saoj/v11n2/09f02.jpg"></p>     <p>&nbsp;</p>     <p>&nbsp;</p>     <p align="center"><img src="/img/revistas/saoj/v11n2/09f03.jpg"></p>     <p>&nbsp;</p>     <p>&nbsp;</p>     <p align="center"><img src="/img/revistas/saoj/v11n2/09f04.jpg"></p>     <p>&nbsp;</p>     ]]></body>
<body><![CDATA[<p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">The cases that    required liner revision and bone grafting were easy to perform and in all cases    graft material showed evidence of incorporation.</font></p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">At 15 years all    surviving patients had well-fixed, functioning acetabular components.</font></p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">Improvements in    bearing surfaces may improve wear rates and granuloma formation in the future    but fixation rates cannot be improved. If we solve the problem of wear, could    joint replacement surgery offer a permanent solution?</font></p>     <p>&nbsp;</p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="3"><b>References</b></font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">1.&nbsp;Grobler    GP, Learmonth ID, Bernstein BP, Dower BJ. Ten-year results of a press fit, porous-coated    acetabular component. <i>J Bone and Joint Surg (Br)</i> 2005;87-B:786-89.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=453333&pid=S1681-150X201200020000900001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">2.&nbsp;Hodgkinson    JP, Shelley P, Wroblewski BM. The correlation between the roentgenographic appearance    and operative findings at the bone-cement junction of the socket in Charnley    low friction arthroplasties. <i>Clin. Orthop.</i> 1988; 228:105-109.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=453334&pid=S1681-150X201200020000900002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">3.&nbsp;Massin    P, Schmidt L, Engh CA. Evaluation of cementless acetabular component migration.    An experimental study. <i>Journal of Arthroplasty.</i> 1989;4:245-51.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=453335&pid=S1681-150X201200020000900003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">4.&nbsp;Hui A,    McCalden R, Martell J, MacDonald S, Bourne R, Rorabeck L. Validation of two    and three dimensional radiographic techniques for measuring polyethylene wear    after total hip arthroplasty. <i>Journal of Bone and Joint Surgery &#91;Am&#93;.</i>    2003;85-A:3;505-11.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=453336&pid=S1681-150X201200020000900004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">5.&nbsp;Martell    J, Berdia S. Determination of polyethylene wear in total hip replacements with    use of digital radiographs. <i>Journal of Bone and Joint Surgery &#91;Am&#93;.</i>    1997;79:1635-41.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=453337&pid=S1681-150X201200020000900005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">6.&nbsp;De Lee    JG, Charnley J. Radiological demarcation of cemented sockets in total hip replacements.    <i>Clinical Orthopaedics.</i> 1976;121:20-32.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=453338&pid=S1681-150X201200020000900006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">7.&nbsp;Garvin    KL, Hartman CW, Mangla J, Murdoch N, Martell JM. Wear analysis in THA utilizing    oxidized Zirconium and crosslinked polyethylene. <i>Clin Orthop Relat Res</i>    2009:467;141-14.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=453339&pid=S1681-150X201200020000900007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><p>&nbsp;</p>     <p>&nbsp;</p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"><b><a name="back"></a><a href="#top"><img src="/img/revistas/saoj/v11n2/seta.jpg" border="0"></a>    Reprint requests:    <br>   </b> Dr M Nortje    <br>   Department of Orthopaedic Surgery    <br>   University of Cape Town H 49 OMB    <br>   Groote Schuur Hospital Observatory,    <br>   7700 Cape Town South Africa    ]]></body>
<body><![CDATA[<br>   Tel: +27 21 4045108    <br>   Email: <a href="mailto:mbnortje@yahoo.com">mbnortje@yahoo.com</a></font></p>      ]]></body>
<REFERENCES></REFERENCES<back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Grobler]]></surname>
<given-names><![CDATA[GP]]></given-names>
</name>
<name>
<surname><![CDATA[Learmonth]]></surname>
<given-names><![CDATA[ID]]></given-names>
</name>
<name>
<surname><![CDATA[Bernstein]]></surname>
<given-names><![CDATA[BP]]></given-names>
</name>
<name>
<surname><![CDATA[Dower]]></surname>
<given-names><![CDATA[BJ.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Ten-year results of a press fit, porous-coated acetabular component.]]></article-title>
<source><![CDATA[J Bone and Joint Surg (Br)]]></source>
<year>2005</year>
<volume>87</volume>
<page-range>786-89.</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hodgkinson]]></surname>
<given-names><![CDATA[JP]]></given-names>
</name>
<name>
<surname><![CDATA[Shelley]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Wroblewski]]></surname>
<given-names><![CDATA[BM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The correlation between the roentgenographic appearance and operative findings at the bone-cement junction of the socket in Charnley low friction arthroplasties.]]></article-title>
<source><![CDATA[Clin. Orthop.]]></source>
<year>1988</year>
<volume>228</volume>
<page-range>105-109.</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Massin]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Schmidt]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Engh]]></surname>
<given-names><![CDATA[CA.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Evaluation of cementless acetabular component migration.]]></article-title>
<source><![CDATA[Journal of Arthroplasty.]]></source>
<year>1989</year>
<volume>4</volume>
<page-range>245-51</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hui]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[McCalden]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Martell]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[MacDonald]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Bourne]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Rorabeck]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Validation of two and three dimensional radiographic techniques for measuring polyethylene wear after total hip arthroplasty.]]></article-title>
<source><![CDATA[Journal of Bone and Joint Surgery]]></source>
<year>2003</year>
<volume>85</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>505-11</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Martell]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Berdia]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Determination of polyethylene wear in total hip replacements with use of digital radiographs.]]></article-title>
<source><![CDATA[Journal of Bone and Joint Surgery]]></source>
<year>1997</year>
<volume>79</volume>
<page-range>1635-41</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[De Lee]]></surname>
<given-names><![CDATA[JG]]></given-names>
</name>
<name>
<surname><![CDATA[Charnley]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Radiological demarcation of cemented sockets in total hip replacements.]]></article-title>
<source><![CDATA[Clinical Orthopaedics.]]></source>
<year>1976</year>
<volume>121</volume>
<page-range>20-32</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Garvin]]></surname>
<given-names><![CDATA[KL]]></given-names>
</name>
<name>
<surname><![CDATA[Hartman]]></surname>
<given-names><![CDATA[CW]]></given-names>
</name>
<name>
<surname><![CDATA[Mangla]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Murdoch]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Martell]]></surname>
<given-names><![CDATA[JM.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Wear analysis in THA utilizing oxidized Zirconium and crosslinked polyethylene.]]></article-title>
<source><![CDATA[Clin Orthop Relat Res]]></source>
<year>2009</year>
<volume>467</volume>
<page-range>141-14</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
