SciELO - Scientific Electronic Library Online

 
vol.77 issue10 author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Article

Indicators

Related links

  • On index processCited by Google
  • On index processSimilars in Google

Share


South African Dental Journal

On-line version ISSN 0375-1562
Print version ISSN 0011-8516

S. Afr. dent. j. vol.77 n.10 Johannesburg Nov. 2022

http://dx.doi.org/10.17159/2519-0105/2022/v77no10a1 

RESEARCH

 

In-vitro comparison of bonding time and strength of adhesive pre-coated and standard metal orthodontic brackets

 

 

R EssopI; E GhabrialII; PJ BeckerIII

IBCom, BChD, Registrar, Department of Orthodontics, Unversity of Pretoria. ORCID: 0000-0001-5374-9355
IIBChD, MchD(Orthod),PhD, H Dent Dipl, PG Dipl Dent (P. Manag) Specialist/ Senior Lecturer, Department of Orthodontics, Unversity of Pretoria . ORCID: 0000-0002-7213-9760
IIIMSc(Pret) PhD(Unisa), Research Office, Faculty of Health Sciences, University of Pretoria ORCID: 0000-0002-9384-6472

Correspondence

 

 


ABSTRACT

OBJECTIVE: To compare the shear bond strength and bond time of 3M Unitek's APC (Adehesive Pre-Coated) Flash-Free system applied to metal brackets.
Materials and Methods: An in vitro study was performed on 40 extracted sound human premolar teeth randomly divided into two groups (20 per group) bonded either with Adhesive Pre-Coated Flash-Free metal brackets or metal brackets coated manually with Transbond XT
light-cure adhesive.
Bonding time was measured using a stopwatch. Thermoycling was performed on the samples (500 cycles) to simulate the oral environment between baths of 5°C and 55°C distilled water. Debonding shear bond strength measurements were performed in an Instron universal testing machine.
RESULTS: The APC Flash-Free group bonded in significantly (p<0.001) less time (mean 34.06s/tooth) than the manually coated group (mean 55.14s/tooth). Shear bond strength of the manually coated group was significantly (p<0.001) higher (mean 13.32 MPa) than the APC Flash-Free group (mean 10.95 MPa).
CONCLUSION: The APC Flash-Free free system is efficient and allows for reduced chair time during the bonding appointment while attaining a mean shear bond strength of 10.95MPa, which is higher than the minimum shear bond strength of between 4MPa and 7MPa1.


 

 

INTRODUCTION

Since the inception of the acid etch technique described by Buonocore2 adhesive dentistry has evolved with a multitude of adhesive products, including orthodontic adhesives.3-5 When a bracket is bonded to a tooth, it is either bonded by manually coating brackets with adhesive or with brackets pre-coated with adhesive.6, 7 One of the problems with manually coated brackets is the need to remove the excess adhesive flash from around the bracket prior to curing.8, 9

The second problem with manually coated brackets is that clinically, a common site of enamel demineralization is at the enamel-adhesive interface of the tooth surrounding an orthodontic bracket.8-11 When the excess adhesive flash is not removed adequately, the rough adhesive surface remaining provides a site for rapid attachment and growth of oral microorganisms.12-14 Patients undergoing orthodontic treatment, thus face a high risk of developing enamel demineralization (white spot lesions) and caries at the bracket-enamel interface.14

The APC Flash-Free Adhesive Coated Appliance system was developed by 3M Unitek (Monrovia, Calif) in 2013 in an attempt to eliminate flash removal.9, 15 The technology was first applied to ceramic brackets in 2013, and in 2016 introduced to metal brackets.9,15 The bracket base comprises a nonwoven polypropylene mesh infused with a low viscosity resin.9,15 When applying pressure to the compressible mat, the resin is expressed in sufficient quantity to spread out and conform to the tooth surface, making uniform and consistent contact with no flash to clean-up.15,16 The low viscosity resin is achieved by reducing the filler content of the adhesive,17 however, Faltermeier et al.18 have shown that a reduction in filler particles results in reduced bond strengths.

In addition, Foersch et al.9 have demonstrated that the APC Flash-Free system did in fact express some flash at the bracket margins when examined microscopically. The flash ranged between 0.08 - 0.16mm, but due to the low viscosity of the resin, was shown to have a smooth surface. This was found to be a positive feature as the minute volume of flash confirms the presence of a marginal seal while the smooth surface is less susceptible to plaque accumulation.9

Research performed by 3M Unitek reported a reduced bonding time, adequate bond strength, and no adhesive flash clean-up when the APC system was applied to ceramic brackets.15 In 2016 3M Unitek applied the APC Flash-Free technology to metal brackets. However, after a thorough literature search, no studies could be located which evaluated the properties of the APC FlashFree technology when applied to metal brackets.

The objective of this study was to determine (1) the shear bond strength (SBS) between APC Flash-Free adhesive coated and manually coated metal Victory Series (3M Unitek, Monrovia, Calif) brackets and (2) to determine whether there is a significant difference in the bond time between the two systems.

 

MATERIALS AND METHODS

Ethics Approval

The study protocol was approved by the Faculty of Health Sciences Research Ethics Committee, University of Pretoria, South Africa. Ethics Reference No.: 499/2017.

Sample

Forty extracted human premolar teeth were collected from the Maxillofacial and Oral Surgery clinic. The sample size was guided by previously published in-vitro studies evaluating bonding time and bracket bond strength on extracted human teeth.6,19-22 Any deposits on the teeth were removed with a brush or a dental scaler and rinsed under running water. The inclusion criteria for the extracted teeth were sound enamel surfaces with no carious lesions, fluorosis or cracks, no demineralisation of the enamel, and no restorations present. The teeth were randomly divided into two groups (20 per group) and stored in a 0.1% Thymol solution to inhibit any microbial growth.23 All teeth were bonded within 48 hours of being extracted.

Brackets

Adhesive precoated brackets were introduced by 3M Unitek in 1991.24 The brackets were precoated with a modified version of Transbond XT that has been developed to have reduce viscosity.24 These earlier APC systems lessened the number of bonding steps; however, flash removal was still necessary.25 In 2013 3M Unitek released the APC Flash-Free system which the company had developed after recognising the shortcomings of excess adhesive flash removal.15 For the purpose of standardisation, maxillary premolar metal twin brackets (Victory Series,3M Unitek, Monrovia, Calif) were used in this study. Twenty uncoated metal (Victory Series) brackets in conjunction Transbond XT (3M Unitek, Monrovia, Calif) were used in the control group (Group 1, Transbond XT) and twenty APC Flash-Free pre-coated metal (Victory Series) brackets were used in the experimental group (Group 2, APC Flash-Free).

 

METHODOLOGY

Bonding procedure: The bonding surfaces of each tooth were polished with non-fluoridated pumice and water for 15 seconds. The surfaces were then rinsed, air dried and etched with 37% phosphoric acid (Ultraetch, Ultradent, St Louis, MO, USA) for 30 seconds. After rinsing and drying, Transbond XT primer (3M Unitek, Monrovia, Calif) was applied and thinned out using a burst of air. The bonding procedure was performed by the principal investigator as follows:

Group 1: Transbond XT was applied to the bracket base directly. The bracket was then placed on the tooth with Arm constant pressure. The excess flash was then removed, and the bracket was corrected to the ideal occluso-gingival and mesio-distal position on the tooth.

Group 2: The APC Flash-Free coated brackets were removed from their individually packaged containers and placed onto the tooth with Arm constant pressure. The bracket was then corrected to the ideal occluso-gingival and mesio-distal position on the tooth.

An LED light curing unit (Woodpecker, Model: LED.B, Woodpecker Medical Instrument Co, Guilin) was used to cure the adhesive. The light was applied for ten seconds (five seconds from the mesial and 5 seconds from the distal of the bracket) at an intensity of between 1070 mw/ cm2 and 1120 mw/cm2.

Measurement of bond time: The bonding procedure was timed to the nearest hundredth of a second by an independent observer using a stopwatch. Timing began when the operator secured the bracket onto the bracket holding forceps and was stopped when the operator deemed the bracket to be in the correct occluso-gingival and mesio-distal position.

Thermocycling: Thermocycling tests were developed after it was noted that oral temperature changes resulted in stresses at the restorative-substrate interface.26 It is a method of simulating oral temperature changes in-vitro by immersing specimens in circulating baths set at predetermined temperatures for predetermined time durations.27 Previous studies have demonstrated that after thermocycling, a significant decrease in shear bond strength was observed.28, 29 Bonded teeth were placed in a net which was attached to the motorised arm of a thermocycling system (Model MX07R-20-A11B, Polyscience Temperature Control Solutions, Niles, Il). The teeth were cycled 500 times between baths of 5°C and 55°C.30 Distilled water was used in the baths, and the exposure time in each bath was 20 seconds with a transfer time of 5 seconds between baths.30

Debonding procedure: The bonded teeth were secured into copper rings which were then mounted onto the clamp of an Instron universal testing machine (Model 3366, Instron Corp, Norwood, MA, USA). The mounted teeth were adjusted until the occlusal portion of the bracket was parallel to the shearing blade of the testing machine. The shearing blade of the Instron machine applied an occluso-gingival load to the bracket at a speed of 1mm per minute and SBS was recorded in Mega Pascals (MPa).

Statistical Analysis

Based on previous studies6, 9,16 31 the expected shear bond strength of the manually coated brackets was 10.4 MPa with a standard deviation of 1.39. A 15% increase or decrease in shear bond strength of the preloaded appliance would therefore be regarded as clinically significant. Based on this, a sample of 20 teeth per group would have a 90% power to detect a 15% change when testing at the 0.05 level of significance.

Descriptive statistics, including the mean, standard deviation, minimum, and maximum values, were calculated for each group tested. The two-sample t-test was used to test for differences between groups and any statistical interaction between the different adhesives used. The Shapiro-Wilks test was used to test the normality of the distribution of Shear Bond Strength and Bond Time. All statistical calculations were performed at the 95% confidence interval.

 

RESULTS

Bond Time

The mean bond time of brackets in Group 1 (Transbond XT) was 55.14s (min: 49.12, max: 59.46, SD: 3.14). Brackets in Group 2 (Flash-Free) were bonded in a mean time of 34.06s (Table 1). According to the two-sample t-test, the time-saving effect of Group 2 (FlashFree) (21.01s per bracket) was found to be statistically significant (p<0.001).

 

 

Shear Bond Strength

The mean SBS of the brackets in Group 1 (Transbond XT) was 13.32 MPa (min: 9.23, max: 15.67, SD: 1.72). The mean SBS of the brackets in Group 2 (Flash-Free) was 10.95 MPa (min: 6.19 MPa, max: 16.7 MPa, SD: 2.29) (Table 2). According to the two-sample t-test, Group 1 (Transbond XT) brackets bonded with a significantly higher shear bond strength than brackets in Group 2 (Flash-Free) (p<0.001).

 

 

DISCUSSION

The objective of this study was to evaluate the shear bond strength (SBS) and bond time of a flash free pre-coated bracket adhesive system (APC Flash-Free, 3M Unitek, Monrovia, California).

This in vitro study demonstrated a statistically significant decrease in bonding time when using the pre-coated APC Flash-Free system [Figure 1]. This was expected since two steps (adhesive application and excess adhesive flash removal) are eliminated from the bonding procedure. The flash-free system took, on average, 21 seconds less to bond per tooth. This agrees with the results of Lee and Kanavakis6 , Foersch et al.,9 and Grunheid and Larson.17 The percentage reduction in bond time per tooth reported by Foersch et al.9 was 58%, Lee and Kanavakis6 74%, and Grunheid and Larson17 - 37%. In this study the percentage reduction in bond time per tooth using the flash-free system was 62%. This equates 8.75 minutes when bonding 25 teeth. However, in a systematic review and meta-analysis, Alakttash et al.32 reported that there was no clinical significance regarding bonding time between pre-coated and manually coated brackets.32

 

 

In this study, the ideal bracket position was marked on each tooth. This step was performed to eliminate the time taken to position each bracket at the correct height and mesio-distal position. Due to variations in tooth morphology, positioning the bracket ideally without prior marking could result in unreliable recorded bond times. It should be considered that the brackets of the flash-free system are sealed individually in a light resistant package and the handling of this packaging during the bonding procedure could possibly affect the overall bond time. In this study the time taken to open the package was not considered when measuring bond time.

Thermocycling is a method of simulating changes in oral temperature which occurs during routine function. This is achieved using circulating baths set at predetermined temperatures. Previous studies have demonstrated that after thermocycling, a significant decrease in shear bond strength was observed.28, 29 In addition, none of the earlier investigators evaluating the APC Flash Free adhesive systems SBS had performed thermocycling on their samples.6, 9, 16

In this study the mean shear bond strength of Group 2 (Flash-Free) (10.95 MPa) was significantly lower than that of Group 1 (Transbond XT) (13.32 MPa) (p<0.001) [Figure 2]. These results conflict with the results of Lee and Kanavakis6, where greater shear bond strengths were achieved with the flash free system compared to manually coated brackets. However, Lee and Kanavakis6 compared ceramic flash free brackets to conventionally bonded metal brackets in their study, and the sample was not subjected to thermocycling.

 

 

In addition, the bond strength achieved by Lee and Kanavakis6 using the flash-free coated ceramic bracket was less than the bond strengths reported by Reddy et al.33 and Uysal et al.34 who investigated manually coated ceramic brackets. Lee and Kanavakis6 reported a mean shear bond strength of 13.37 MPa for their flashfree sample which was comparable to the mean shear bond strength achieved on conventionally bonded metal brackets (13.32 MPa) in the present study. This was unexpected since previous studies have demonstrated that ceramic brackets bond with greater shear bond strengths than metal brackets.33, 34 This could possibly be explained by the debonding method used by Lee and Kanavakis6 in which a tensile shearing force was applied to the bracket whereas in the present study a compressive shearing force was used.

According to Reynolds, the minimum shear bond strength required for clinical success should be in the range of 6 to 8 MPa.1 Despite the lower bond strength of the flash free adhesive bracket system compared to conventionally bonded brackets in the present study and in the research by Lee and Kanavakis6, the APC Flash Free bracket system bonded with sufficient strength for clinical use when integrated on either metal or ceramic brackets. In addition, Alakttash et al.32 reported no difference of pre-coated brackets over manually coated bracket systems regarding the clinical failure rate of brackets.

 

CONCLUSION

This study demonstrated that the APC Flash-Free system applied to metal brackets produced shear bond strengths adequate for clinical use.

The APC Flash-Free system is a convenient bonding method which could potentially save significant chair time.

Conflict of interest

None declared.

 

REFERENCES

1. Reynolds IR. A Review of Direct Orthodontic Bonding. Br J Orthod. 1975;2(3):171-8.         [ Links ]

2. Buonocore MG. A simple method of increasing the adhesion of acrylic Alling materials to enamel surfaces. J Dent Res. 1955;34(6):849-53.         [ Links ]

3. Anusavice KJ, Phillips RW, Shen C, Rawls HR. Phillips' science of dental materials. St. Louis, Mo.: Saunders; 2013.         [ Links ]

4. Green JIJ. The origins and evolution of fixed orthodontic appliances. J Dent Nurs. 2014;10:524-8.         [ Links ]

5. Ewoldsen N, Demke RS. A review of orthodontic cements and adhesives. Am J Orthod Dentofacial Orthop. 2001;120(1):45-8.         [ Links ]

6. Lee M, Kanavakis G. Comparison of shear bond strength and bonding time of a novel flash-free bonding system. Angle Orthod. 2016;86(2):265-70.         [ Links ]

7. Grünheid T, Sudit GN, Larson BE. Debonding and adhesive remnant cleanup: an in vitro comparison of bond quality, adhesive remnant cleanup, and orthodontic acceptance of a flash-free product. Eur J Orthod. 2015;37(5):497-502.         [ Links ]

8. Kim J, Kanavakis G, Finkelman MD, Lee M. Microleakage under ceramic flash-free orthodontic brackets after thermal cycling. Angle Orthod. 2016;86(6):905-8.         [ Links ]

9. Foersch M, Schuster C, Rahimi RK, Wehrbein H, Jacobs C. A new flash-free orthodontic adhesive system: A first clinical and stereomicroscopic study. Angle Orthod. 2016;86(2):260-4.         [ Links ]

10. Gwinnett AJ, Ceen RF. Plaque distribution on bonded brackets: a scanning microscope study. Am J Orthod Dentofacial Orthop. 1979;75(6):667-77.         [ Links ]

11. Ho CS, Ming Y, Foong KW, Rosa V, Thuyen T, Seneviratne CJ. Streptococcus mutans forms xylitol-resistant biofilm on excess adhesive flash in novel ex-vivo orthodontic bracket model. Am J Orthod Dentofacial Orthop. 2017;151(4):669-77.         [ Links ]

12. Mei L, Busscher HJ, van der Mei HC, Ren Y. Influence of surface roughness on streptococcal adhesion forces to composite resins. Dent Mater J. 2011;27(8):770-8.         [ Links ]

13. Årtun J, Brobakken BO. Prevalence of carious white spots after orthodontic treatment with multibonded appliances. Eur J Orthod. 1986;8(4):229-34.         [ Links ]

14. Rosenbloom RG, Tinanoff N. Salivary Streptococcus mutans levels in patients before, during, and after orthodontic treatment. Am J Orthod Dentofacial Orthop. 1991;100(1):35-7.         [ Links ]

15. Cinader DK, Aung M, Ugai R, Conley A. APC Flash-free adhesive: a technical overview. Orthodontic Perspectives. 2013;20(1):7-9.         [ Links ]

16. Grunheid T, Sudit GN, Larson BE. Debonding and adhesive remnant cleanup: an in vitro comparison of bond quality, adhesive remnant cleanup, and orthodontic acceptance of a flash-free product. Eur J Orthod. 2015;37(5):497-502.         [ Links ]

17. Grünheid T, Larson BE. Comparative assessment of bonding time and 1-year bracket survival using flash-free and conventional adhesives for orthodontic bracket bonding: A split-mouth randomized controlled clinical trial. Am J Orthod Dentofacial Orthop. 2018;154(5):621-8.         [ Links ]

18. Faltermeier A, Rosentritt M, Faltermeier R, Reicheneder C, Müßig D. Influence of filler level on the bond strength of orthodontic adhesives. Angle Orthod. 2007;77(3):494-8.         [ Links ]

19. Bishara SE, Gordan VV, VonWald L, Jakobsen JR. Shear bond strength of composite, glass ionomer, and acidic primer adhesive systems. Am J Orthod Dentofacial Orthop. 1999;115(1):24-8.         [ Links ]

20. Bishara SE, VonWald L, Laffoon JF, Warren JJ. Effect of a self-etch primer/adhesive on the shear bond strength of orthodontic brackets. Am J Orthod Dentofacial Orthop. 2001;119(6):621-4.         [ Links ]

21. Bishara SE, Olsen ME, Jakobsen JR. Evaluation of a new light-cured orthodontic bonding adhesive. Am J Orthod Dentofacial Orthop. 1998;114(1):80-7.         [ Links ]

22. Toledano M, Osorio R, Osorio E, Romeo A, de la Higuera B, Garcia-Godoy F. Bond strength of orthodontic brackets using different light and self-curing cements. Angle Orthod. 2003;73(1):56-63.         [ Links ]

23. Aydin B, Pamir T, Baltaci A, Orman MN, Turk T. Effect of storage solutions on microhardness of crown enamel and dentin. Eur J Dent. 2015;9(2):262-6.         [ Links ]

24. Hirani S, Sherriff M. Bonding characteristics of a self-etching primer and precoated brackets: an in vitro study. Eur J Orthod. 2006;28(4):400-4.         [ Links ]

25. Oliver B, Dama M. A retrospective six-months clinical trial of adhesive precoated brackets and bonding system. J Can Dent Assoc. 1997;63(2):101-3, 7.         [ Links ]

26. Nelsen RJ, Paffenbarger GC, Wolcott RB. Fluid exchange at the margins of dental restorations. JADA. 1952;44(3):288-95.         [ Links ]

27. Gale MS, Darvell BW. Thermal cycling procedures for laboratory testing of dental restorations. J Dent 1999;27(2):89-99.         [ Links ]

28. Summers A, Kao E, Gilmore J, Gunel E, Ngan P. Comparison of bond strength between a conventional resin adhesive and a resin-modified glass ionomer adhesive: an in vitro and in vivo study. Am J Orthod Dentofacial Orthop. 2004;126(2):200-6.         [ Links ]

29. Rix D, Foley TF, Mamandras A. Comparison of bond strength of three adhesives: composite resin, hybrid GIC, and glass-filled GIC. Am J Orthod Dentofacial Orthop. 2001;119(1):36-42.         [ Links ]

30. Bishara SE, Ostby AW, Laffoon JF, Warren J. Shear bond strength comparison of two adhesive systems following thermocycling: a new self-etch primer and a resin-modified glass ionomer. Angle Orthod. 2007;77(2):337-41.         [ Links ]

31. Bishara SE, Oonsombat C, Soliman MM, Warren JJ, Laffoon JF, Ajlouni R. Comparison of bonding time and shear bond strength between a conventional and a new integrated bonding system. Angle Orthod. 2005;75(2):237-42.         [ Links ]

32. Alakttash AM, Fawzi M, Bearn D. Adhesive precoated bracket systems and operator coated bracket systems: Is there any difference? A systematic review and meta-analysis. Angle Orthod. 2019;89(3):495-504.         [ Links ]

33. Reddy YG, Sharma R, Singh A, Agrawal V, Chaturvedi S. The Shear Bond Strengths of Metal and Ceramic Brackets: An in-Vitro Comparative Study. JCDR. 2013;7(7):1495-7.         [ Links ]

34. Uysal T, Ustdal A, Kurt G. Evaluation of shear bond strength of metallic and ceramic brackets bonded to enamel prepared with self-etching primer. Eur J Orthod. 2009;32(2):214-8.         [ Links ]

 

 

Correspondence:
Dr Rashid Essop
Registrar, Department of Orthodontic, University of Pretoria
Email: essoprashid@gmail.com
Tel: 0833388882

 

 

Author contributions:
1 . Dr Rashid Essop: 80%
2 . Dr Emad Ghabrial: 10%
3 . Prof Piet J Becker: 10%

Creative Commons License All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License