SciELO - Scientific Electronic Library Online

 
vol.12 número1Evaluation of the Ogawa-Kudoh method for tuberculosis isolation in two health units in MozambiqueDetecting tuberculosis in pregnant and postpartum women in Eswatini índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Artigo

Indicadores

Links relacionados

  • Em processo de indexaçãoCitado por Google
  • Em processo de indexaçãoSimilares em Google

Compartilhar


African Journal of Laboratory Medicine

versão On-line ISSN 2225-2010
versão impressa ISSN 2225-2002

Resumo

FERNANDO, Caroline A. et al. Alternative methods for calculating percentage haemolysis of red cell concentrates in peripheral blood banks in Sri Lanka. Afr. J. Lab. Med. [online]. 2023, vol.12, n.1, pp.1-7. ISSN 2225-2010.  http://dx.doi.org/10.4102/ajlm.v12i1.1987.

BACKGROUND: Haemolysis - one of the major limiting factors of red cell concentrate quality - must be measured as a quality-monitoring requirement. According to international quality standards, percentage haemolysis must be monitored in 1.0% of red cell concentrates produced monthly and maintained under 0.8%. OBJECTIVE: This study assessed three alternative methods for determining plasma haemoglobin concentration in peripheral blood banks that lack a plasma or low haemoglobin photometer - the gold-standard method - in Sri Lanka METHODS: A standard haemolysate was prepared using an unexpired whole blood pack of normal haemoglobin concentration. A concentration series from 0.1 g/dL to 1.0 g/dL was prepared by diluting portions of standard haemolysate with saline. The alternative methods, namely visual haemoglobin colour scale, spectrophotometric calibration graph, and standard haemolysate capillary tube comparison, were designed using this concentration series and were used to test red cell concentrates received at the Quality Control Department of the National Blood Center, Sri Lanka, from February 2021 to May 2021. RESULTS: A strong correlation was observed between the haemoglobin photometer method and the alternative methods (R = ~0.9). Based on the linear regression model, the standard haemolysate capillary tube comparison method was the best of the three alternative methods (R2 = 0.974). CONCLUSION: All three alternative methods are recommended for use in peripheral blood banks. The standard haemolysate capillary tube comparison method was the best model.

Palavras-chave : blood banks; capillary tube comparison; haemoglobin colour scale; percentage haemolysis; red cell concentrate.

        · texto em Inglês     · Inglês ( pdf )

 

Creative Commons License Todo o conteúdo deste periódico, exceto onde está identificado, está licenciado sob uma Licença Creative Commons