SciELO - Scientific Electronic Library Online

 
vol.50 número1Evaluating the environmental and social net-worth of controlling alien plant invasions in the Inkomati catchment, South AfricaOccurrence of PAHs in water samples of the Diep River, South Africa índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Articulo

Indicadores

Links relacionados

  • En proceso de indezaciónCitado por Google
  • En proceso de indezaciónSimilares en Google

Compartir


Water SA

versión On-line ISSN 1816-7950
versión impresa ISSN 0378-4738

Resumen

GUL, Enes; KILIC, Zeyneb; IKINCIOGULLARI, Erding  y  CIHAN AYDIN, M. Investigation of the effect of variable-sized energy dissipating blocks on sluice gate performance. Water SA [online]. 2024, vol.50, n.1, pp.92-105. ISSN 1816-7950.  http://dx.doi.org/10.17159/wsa/2024.v50.i1.4064.

The present research used a combination of experimental and numerical methods to investigate energy dissipation blocks of different heights placed downstream of a sluice gate in an open channel flow. Numerical model simulations were performed using a 3D computational fluid dynamics (CFD) technique, using the Reynolds-averaged Navier-Stokes (RANS) equations with the volume of fluid (VOF) and k-ε turbulence models. The accuracy of the numerical model and the grid sensitivity was assessed according to a recommended procedure in the literature. Different hydraulic and geometry conditions were investigated to understand the energy dissipation behaviour of the blocks. The hydrodynamic effects of different block spacings, heights and configurations were analysed by means of CFD simulations. The results show that the variable size blocks have a high energy dissipation efficiency in sluice gate flows, particularly at high Froude numbers. The energy dissipation efficiency of the blocks downstream of a sluice gate can reach up to 55% for high discharges (Q = 35 L/s). Interestingly, the energy dissipation performance of small gate openings exceeds that of large gate openings, reaching a peak efficiency of 40% for the same discharge. In addition, the block spacing has a minimal effect on the energy dissipation, while smaller block spacing results in a smoother water surface profile.

Palabras clave : sluice gate flow; energy dissipation; free surface flow; computational fluid.

        · texto en Inglés     · Inglés ( pdf )

 

Creative Commons License Todo el contenido de esta revista, excepto dónde está identificado, está bajo una Licencia Creative Commons